Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

Similar documents
READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

SUPER T WALL FANS. Installation and Wiring Instructions

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Installation and Wiring Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Centrif Duo & Centrif Duo Plus

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Lo-Carbon SELV Tempra

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Silhouette Installation and Wiring Instructions

Lo-Carbon Quadra SELV

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon T-series Window & Roof Models

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

HR200WK Through the wall Heat Recovery Ventilator

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

100 FLUEBOOST

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

FLUEBOOST. flueboost 350 gas fire model

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Sentinel Kinetic MVHR RANGE

XB-EFA-8L-BK & XB-EFA-8R-BK

Lo-Carbon PoziDry Pro

AXUS - SC Short Cased Axial Flow Fans Installation and Maintenance

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Warnings, Safety Information and Guidance

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Purge Ventilation Unit. Product Manual. ventilation systems TP625


AP-EH500-L/RQA9837. Installation Guide

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)

ACN SMOKE INSTALLATION AND MAINTENANCE

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

HIT Centrifugal In-Line Fan

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

WHHR Midi & Midi Lite

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Whole Room Dryer WRD, WRD/110

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

INSTALLATION INSTRUCTIONS USER GUIDE

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!

HOTLINE:

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

English CNA-CNB. Centrifugal fans Installation and maintenance

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Sentinel. Kinetic Advance MVHR. Installation & Commissioning. Stock Ref. N Advance S Advance SX

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

EDD61 & EDD91 Extractors

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Condensing Units CUS 15-60

DBF 4XL Dryer Booster Fans

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

MJC Cartridge Filter Unit Operation & Maintenance

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Flomate Mains Boost Pump Installation & Maintenance Instructions

HEAVY DUTY BRASS SHOWER PUMPS

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

90cm Chimney Extractor

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Transcription:

Long Case Axial Fan Installation and Wiring Instructions 220-240V/1/50Hz & 380-415V/3/50Hz RAD INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLAS SAV THS INSTRUCTIONS

Installation and Wiring Instructions for the Case Axial Fan. IMPORTANT: RAD THS INSTRUCTIONS BFOR COMMNCING TH INSTALLATION DO NOT install this product in areas where the following may be present or occur: xcessive oil or a grease laden atmosphere. Corrosive or flammable gases, liquids or vapors. Ambient temperatures less than 5 C or higher than 54 C. Relative humidity above 95% Possible obstructions which would hinder the access or removal of the fan. Sudden ductwork bends or transformations close to the fan. SAFTY AND GUIDANC NOTS Air moving equipment may present mechanical, electrical or noise hazards. To minimise the risks associated with these potential hazards, it is essential that installation, operation and maintenance instructions are followed and carried out by a suitably qualified person. A. All wiring to be in accordance with the current I... Regulations, or the appropriate standards of your country. B. The Fan should be provided with a local 2/3 pole isolator switch having a contact separation of at least 3mm. C. nsure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products.. It is recommended that the connection to the terminal box is made with flexible cable/conduit. F. The fan should not be sited within 600mm horizontally of/or 2250mm vertically of a bath/shower tray, in accordance with the I... Regulations for bathrooms. G. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuel-burning appliance. H. If the fan is used to supply air into a room, the installer must ensure that the fan intake is located a minimum of 600mm from any flue outlet. I. This fan is designed as an inline ducted fan to be positioned between lengths of ducting. Short duct runs terminating within 1.5m must incorporate suitable guards. J. Certain applications may require the installation of sound attenuation material, together with either an Auto Transformer or to achieve the sound levels required. DSCRIPTION. The Long Case Axial range of fans incorporates factory adjustable pitch impellers, which provide a comprehensive range of duties offering high performance and pressure characteristics. Available in twelve sizes ranging from 315mm to 1250mm ø and performances from 0.24m 3 /s to 38m 3 /s with a pressure development up to 1250Pa. The casing is constructed from rolled steel plate and protected with a galvanised finish. A. INSTALLATION. 1. nsure the impeller rotates and is free from obstruction, prior to installation. 2. The fan is suitable for mounting at any angle. 3. nsure that there is adequate clearance for accessing the fan. 4. Securely mount the fan using the holes in the end flanges and use the appropriate drop rods, bolts, antivibration mountings etc. 5. nsure the Airflow Arrow is aligned with the direction of the airflow required. 6. The use of flexible connections and anti-vibration mountings is recommended to minimise noise and vibration. 7. nsure that the flexible connections are taut and the fan and ductwork are aligned. 8. Flexible connections MUST be used in conjunction with anti-vibration mountings. 9. Anti-vibration mountings must be installed in compression. 2

Fig.1. TYPICAL INSTALLATION (Horizontal). AXIAL FAN FLXIBL CONNCTION FLXIBL CONNCTION MOUNTING FT WIRING ANTI-VIBRATION MOUNTINGS WARNING: TH FAN AND ANCILLARY CONTROL QUIPMNT MUST B ISOLATD FROM TH POWR SUPPLY DURING TH INSTALLATION / OR MAINTNANC. TH QUIPMNT MUST B ARTHD 1. Select and follow the appropriate wiring diagram (Figs. 2-11). 2. Check all connections have been made correctly and ensure that all terminal connections and cable clamps are securely fastened. 3. The cable entry must be made using a suitable grommet or cable gland. 4. Switch the mains power supply on and check the fan is operating correctly. Fig. 2. Single Phase Fan Connected to a 240V D.O.L. Starter. Fig. 3. Single Phase Fan Connected to a 240V D.O.L. Starter an Auto Transformer. 1 Phase Supply (220-240V 50 Hz). L ~ N 1 Phase Supply (220-240V 50 Hz). L ~ N LC31/1/8-32 LC35/1/8-32 LC40/1/8-28 240 Volt D.O.L. Starter A suitable sized overload relay must be fitted to provide motor protection. N.B. Links between terminals 1 to, 3 to 6, 5 to 95 and 24 to 96 must be fitted. LC31A4/1/8-32 LC35A4/1/8-32 LC40A4/1/8-32 LC45A4/1/8-32 LC50A4/1/8-28 LC56A4/1/8-26 LC63A4/1/8-22 L 1 2 3 5 95 4 6 96 N U1 U2 FAN TRMINAL 23 24 240 Volt D.O.L. Starter A suitable sized overload relay must be fitted to provide motor protection. N.B. Links between terminals 1 to, 3 to 6, 5 to 95 and 24 to 96 must be fitted. 1 Phase Auto Transformer. 103 14 103 103 14 105 103 14 107 103 14 113 1 3 2 4 L2 N1 5 6 Fuse L L1 95 23 96 24 N N N LC31A4/1/8-32 LC35A4/1/8-32 LC40A4/1/8-32 LC45A4/1/8-32 LC50A4/1/8-28 LC56A4/1/8-26 LC63A4/1/8-22 L U1 U2 FAN TRMINAL 3

Fig. 4. Three Phase Fan Connected to a 415V D.O.L. Starter. Fig. 5. Three Phase Fan Connected to a Star / Delta Starter. STAR / DLTA Starter with current overload protection and a 415 volt coil. 3 Phase Supply (380-415V 50Hz). L1 L2 L3 3 Phase Supply (380-415V 50Hz). L1 L2 L3 415 Volt D.O.L. Starter A suitable sized overload relay must be fitted to provide motor protection. N.B. Links between terminals 5 to 95 and 24 to 96 must be fitted. 1 2 3 4 5 6 95 96 23 24 23 24 95 96 STAR / DLTA STARTR 2 4 6 1 2 3 4 5 6 L1 L2 L3 LC31/3/8-32º LC35/3/8-32º LC40/3/8-28º LC45/3/8-24º LC50/3/8-16º LC31A4/3/8-32º LC35A4/3/8-32º LC40A4/3/8-32º LC45A4/3/8-32º LC50A4/3/8-28º LC56A4/3/8-26º LC63A4/3/8-30º LC71A4/3/8-18º U1 W2 V1 W1 U2 V2 FAN TRMINAL LC50/3/18-26º LC56/3/8-24º LC63/3/8-16º LC71A4/3/20-30º LC80A4/3/8-28º LC90A4/3/8-26º LC100A4/3/8-28º LC125A4/3/8-24º W2 U1 U2 V1 V2 W1 FAN TRMINAL Fig. 6. Three Phase Fan Connected to a 415V D.O.L. Starter and an Auto Transformer. 3 Phase Supply (380-415V 50Hz). N L1 L2 L3 415 Volt D.O.L. Starter A suitable sized overload relay must be fitted to provide motor protection. 1 3 5 N.B. Links between terminals 1 to, 5 to 95 must be fitted and the link between terminals 24 to 96 must be FITTD. 95 23 2 4 6 96 24 3 Phase Auto Transformer. 103-14-301 103-14-304 103-14-307 TK TK W1 V1 U1 N L3 L2 L1 LC31A4/3/8-32º LC35A4/3/8-32º LC40A4/3/8-32º LC45A4/3/8-32º LC50A4/3/8-28º LC56A4/3/8-26º LC63A4/3/8-30º LC71A4/3/8-18º U1 V1 W1 W2 U2 V2 FAN TRMINAL NOT: If an Auto Transformer is being used to control the Fan speed, the reset facility MUST be disabled. Contact Vent-Axia s Technical Support Line for details. 4

Fig. 7. Three Phase Fan Fig. 8. Three Phase Fan Single Phase in Three Phase (240V) Out Single Phase in Three Phase (240V) Out LC Fan connected to an Speed LC Fan connected to an Speed Controller Kit (103 20 101). Controller Kit (103 20 102 or 103 20 103). 1 Phase Supply (220-240V). L~N 1 Phase Supply (220-240V). L~N 455552 455553 or 455554 LC31/3/8-32º LC35/3/8-32º LC40/3/8-16º Metal nclosure & LC31A4/3/8-32º LC35A4/3/8-32º LC40A4/3/8-32º LC45A4/3/8-32º LC50A4/3/8-28º LC56A4/3/8-20º Connector U1 V1 W1 W2 U2 FAN TRMINAL V2 Shielded Cable ILVC 1 (103-20-601) Ferrite Coil (Loop the fan supply cable around the ferrite coil 3 times). Shielding. (WRAP WITH INSULATION TAP). Shielding. (WRAP WITH INSULATION TAP DO NOT CONNCT TO TH ARTH TRMINAL). 3 PHAS SUPPLY (230-240 Volts) LC40/3/18-28º Metal nclosure & LC56A4/3/22-26º LC63A4/3/8-22º LC71A4/3/8-18º Connector U1 V1 W1 W2 U2 FAN TRMINAL Fig. 9. Three Phase Fan. Three Phase In Three Phase Out. LC Fan connected to an Kit (103 20 301, 103 20 302, 103 20 303 or 103 20 305). V2 ILVC 1 (103-20-601) Ferrite Coil (Loop the fan supply cable around the ferrite coil 3 times). Shielded Cable Shielding. (WRAP WITH INSULATION TAP). Shielding. (WRAP WITH INSULATION TAP DO NOT CONNCT TO TH ARTH TRMINAL). 3 PHAS SUPPLY (230-240 Volts) Metal nclosure & 455556, 455557, 455558 or 103 20 303 ILVC 2 (103-20-602) Filter 103-20-505 103-20-512 LC31A 2/3/8-32º LC35A 2/3/8-32º LC40A 2/3/8-28º LC45A 2/3/8-24º LC50A 2/3/8-16º LC31A 4/3/8-32º LC35A 4/3/8-32º LC40A 4/3/8-32º LC45A 4/3/8-32º LC50A 4/3/8-28º LC56A 4/3/8-26º LC63A 4/3/8-30º LC71A 4/3/8-18º 5

Fig. 10. Three Phase Fan. Three Phase In Three Phase Out. LC Fan connected to an Kit (103 20 350 or 103 20 310). Metal nclosure & 455559 or 455560 ILVC 2 (103-20-602) Filter 103-20-512 103-20-524 LC50/3/18-26º LC56/3/8-24º LC63/3/8-16º LC71A4/3/20-30º LC80A4/3/8-28º LC90A4/3/8-18º LC100A4/3/8-12º 6

Fig. 11. Three Phase Fan. Three Phase In Three Phase Out. LC Fan connected to an Kit (103 20 315). Metal nclosure & 103 20 315 ILVC 2 (103-20-602) Filter 103 20 524 LC90A4/3/20-26º LC100A4/3/14-16º ROUTIN INSPCTION AND MAINTNANC ISOLAT FROM TH POWR SUPPLY AND NSUR THAT TH FAN CANNOT B ACCIDNTALLY SWITCHD BACK ON. 1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits on the impeller or motor. If the fan is handling dust laden air, it is recommend that a filter is installed. 2. All Case Axial fans have sealed for life bearings and do not require lubrication. 3. Check the condition and security of all fixing bolts, rods, anti-vibration mountings, and flexible connections. 7

VNT-AXIA SALS CNTRS NGLAND & WALS NATIONAL CALL CNTR SCOTLAND Newton Road, Crawley West Sussex Telephone: 0141 429 1166 RH10 9JA Fax: 01293 565169 Telephone: 01293 530202 RPUBLIC OF IRLAND Fax: 01293 565169 Vent-Axia Ventilation Ltd. 921 Western Road Industrial state NORTHRN IRLAND Naas Road, Dublin 12. Telephone: 02890 402220 Telephone: (01) 450 4133 Fax: 01293 565169 Fax: (01) 450 4570 Did you find these instructions easy to use? We value your comments, contact us via : mail: info@vent-axia.com The Vent-Axia Guarantee Applicable only to products installed and used in the United Kingdom. For details of the Guarantee outside of the United Kingdom contact your local supplier. Vent-Axia guarantees this product for two years from the date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s discretion the product will be replaced without charge, provided that the product: 1). Has been installed and used in accordance with the instruction given with each unit. 2). Has not been connected to an unsuitable electricity supply (The correct electricity supply voltage shown on the product-rating label attached to the unit). 3). Has not been misused, neglected or damaged. 4). Has not been modified or repaired by any person not authorised to do so by Vent-Axia. IF CLAIMING UNDR TH TRMS OF TH GUARANT Please return the complete product, carriage paid to your original supplier by post or in person. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing proof of the date and source of purchase. As part of the policy of continuous product improvement Vent-Axia reserve the right to alter specifications without notice Head Office: Fleming Way, Crawley, West Sussex RH10 9YX Tel: 01293 526062 Fax: 01293 551188 Internet site at: www.vent-axia.com 454062 C 0403 8

DCLARATION OF CONFORMITY Vent-Axia Ltd. Newton Road Crawley, West Sussex, RH10 9JA C DCLARATION OF CONFORMITY. Here with we declare that the air movement equipment designated below, on the basis of its design and construction in the form brought onto the market by us in accordance with the relevant safety and health requirements of the C Directive on Machinery. If alterations are made to the machinery without prior consultations with us, this declaration becomes invalid. DSIGNATION OF QUIPMNT: VNTILATION FAN. SRIS TYP: LONG CAS AXIAL FAN. Applied Authorisation Standards (1) N 292-1, N 292-2, N294 in particular: N 50081-2, N 60204-1. Applied National Standards and BS 848 Part 1, Technical Specifications (2) BS 848 Part 2, in particular: BS 848 Part 3. Basis of self attestation Working to Quality Assurance: BS N ISO 9001 Signatory: R.D.A Spearman. Product Director. Place / Date Crawley April 2003 Notes: 1. For the complete list of applied standards and technical specifications see Vent- Axia Ltd. Documentation. 2. Where no relevant harmonised standards exist. 425965 A 0403 9