SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

Similar documents
GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Model 4001 Series Single Channel Controller

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Two-Channel Gas Controller

Model D12. Digital Gas Transmitter

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

MBCE-110/230UV Flame Sensor Module

Oxygen (O2) Single-Point Gas Detection System

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Water Detection Controllers

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Power Supply Display Module PSDM. Installation and Operation Manual

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Analog Room Pressure Monitor RPC Series

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Carbon Monoxide Transmitter

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Instruction Manual Model A

Combustible Gas Detection and Control System

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Duct and Rough Service Carbon Monoxide Sensor

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

APPLICATION DATA SHEET

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

ANNUNCIATOR FIXED MODULE

MBCE-110/230FR Flame Sensor Module

Beacon 110 Gas Monitor Operator s Manual

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

MBCE-110/230FR Flame Sensor Module

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

GAS PLUS ALARM SYSTEM

LifeAlarm Fire Alarm Controls

Beacon 800 Gas Monitor Operator s Manual

Commercial and Light Industrial Fire Alarm Control Panel

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 410A Gas Monitor Operator s Manual

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

RAM3 Remote Alarm Module

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

SEC 2000 Millenium Infrared Gas Detector

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Technical Manual. Touchpoint 4 4 Channel Gas Detector Controller

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

INTRODUCTION / TABLE OF CONTENTS

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Installation Guide for models:

Installation Instructions for W2H Series Signals

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Sensepoint XCL Fixed Gas Detector

RKA-LEL Sample Draw Combustible Gas Detector

AL600ULX Series. Power Supply/Charger. Installation Guide

INSTRUCTION & SERVICE MANUAL

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Remote NAC Power Supply D7038

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Series. Access Power Controllers. Installation Guide

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Installation Guide for models:

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Industrial Automation Enclosure

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

INTRODUCTION / TABLE OF CONTENTS

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

MODELS 304GC, 304GCX, 314GC, and 314GCX

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Interface and EOL Modules 8

MANUAL RESET ALARM RELEASE

Transcription:

Series A14 GasSens - General Arrangement Diagrams SINGLE CHANNEL SYSTEM BATTERY BACK-UP (00-0057) (OPTIONAL) 4-20 ma OUTPUT (3) SPDT, 10A ALARM RELAYS (1) SPDT, 10A TROUBLE RELAY 2 COND, 20 AWG, 100' MAX. POWER 85-255 VAC or VDC 2 COND, 20 AWG, 1000' MAX. 2 COND, 16 AWG, 500' MAX. (COMBUSTIBLE GAS ONLY) SENSOR/TRANSMITTER GAS SPECIFIC TWO CHANNEL SYSTEM BATTERY BACK-UP (00-0057) (OPTIONAL) 4-20 ma OUTPUT (TYPICAL EACH CHANNEL) (3) SPDT, 10A ALARM RELAYS (TYPICAL EACH CHANNEL) (1) SPDT, 10A TROUBLE RELAY (TYPICAL EACH CHANNEL) 2 COND, 20 AWG, 100' MAX. POWER 85-255 VAC or VDC 2 COND, 20 AWG, 1000' MAX. 2 COND, 16 AWG, 500' MAX. (COMBUSTIBLE GAS ONLY) (TYPICAL EACH CHANNEL) SENSOR/TRANSMITTER (GAS SPECIFIC) SENSOR/TRANSMITTER (GAS SPECIFIC) Page 1 of 14

Series A14 GasSens - General Arrangement Diagrams FOUR CHANNEL SYSTEM (4) SENSOR/TRANSMITTERS 4-20 ma OUTPUT (TYPICAL EACH CHANNEL) (3) SPDT, 10A ALARM RELAYS (TYPICAL EACH CHANNEL) (1) SPDT, 10A TROUBLE RELAY (TYPICAL EACH CHANNEL) 2 COND, 20 AWG, 1000' MAX. 2 COND, 16 AWG, 500' MAX. (COMBUSTIBLE GAS ONLY) (TYPICAL EACH CHANNEL) TO BATTERY BACK-UP (2 COND, 20 AWG, 100' MAX.) POWER 85-255 VAC or VDC 1) Detection systems of 5-8 channels consist of a duplicate 4 channel enclosure with up to 4 additional receivers. The general arrange ment is duplicated for the second enclosure. The two enclosures are connected together to maintain Nema-4X rating. Page 2 of 14

Series A14 GasSens - System Wiring STANDARD SYSTEM Analytical Technology, Inc. Page 3 of 14

Series A14 GasSens - Terminal Designations A14 RECEIVER TERMINAL DESIGNATIONS TB1 TB1 TB2 PPM TROUBLE WARN ALARM NOTE:Relay contact designation is shown for relays in normal mode of operation for relays A1, A2, and A3. If fail-safe relay operation is selected, NO and NC designations are reversed for that relay. The TROUBLE relay is set to fail-safe operation at the factory, and the designation shown above is for the trouble relay in fail-safe mode. 1: (+12)... Module Power Positive (12 VDC) 2: (C)... Module Power Common 3: ( )... Earth Ground (REQUIRED) 4: (H+)... Audible Horn positive 5: (H-)... Audible Horn negative 6: (RR)... Remote Reset 7: (RR)... Remote Reset 8: (MA+)... 4-20 ma Output Positive 9: (MA-)... 4-20 ma Output Negative 10: ( )... Earth Ground 11: (TR)... Transmitter Input 12: (TR)... Transmitter Input TB2 1: (A1 NO)... Alarm 1 Normally Open Contact 2: (A1 C)... Alarm 1 Common 3: (A1 NC)... Alarm 1 Normally Closed Contact 4: (A2 NO)... Alarm 2 Normally Open Contact 5: (A2 C)... Alarm 2 Common 6: (A2 NC)... Alarm 2 Normally Closed Contact 7: (A3 NO)... Alarm 3 Normally Open Contact 8: (A3 C)... Alarm 3 Common 9: (A3 NC)... Alarm 3 Normally Closed Contact 10: (TROUBLE NC)... Trouble Normally Closed Contact 11: (TROUBLE C)... Trouble Common 12: (TROUBLE NO)... Trouble Normally Open Contact A17 POWER SUPPLY TERMINAL DESIGNATIONS TB1 (12V Battery Only) 1: (B+)...External Battery Positive 2: (B-)...External Battery Negative 3: ( )...Earth Ground TB2 1: (+12)...Receiver Module Positive 2: (C)...Receiver Module Common 3: ( )...Earth Ground TB3 Analytical Technology, Inc. 1: (+12)...Receiver Module Positive 2: (C)...Receiver Module Common 3: ( )...Earth Ground TB4 1: (H)...AC Power Hot (85-255 VAC) 2: (N)...AC Power Neutral 3: ( )...Power Ground (Earth Ground) TB5 CAUTION: AC power input must be properly earth grounded for safe operation. 220 VAC power without a neutral line may not be used with this power supply. 1: (NC)...Power Failure Normally Closed Contact 2: (C)...Power Failure Common 3: (NO)...Power Failure Normally Open Contact Page 4 of 14

Series A14 GasSens - Electrical Connections 65W P/S (28-0004) WIRING CONNECTION DIAGRAM Typical Wiring for Large 3 Module, Large 6 Module, 9 Module & 12 Module Enclosures ATI-0544 Page 5 of 14

Series A14 GasSens - Receiver Enclosures - Dimensional RECEIVER/POWER SUPPLY MODULES #80-0005 SINGLE MODULE ENCLOSURE 3.54" 90mm 1.77" 45mm 2.40" 61mm 7.09" 180mm 6.496" 165mm 1.69" 43mm 2.28" 58mm 2.76" 70mm.20" 5mm 3.74" 95mm 4.33" 110mm 4.33" 110mm #80-0006 TWO MODULE ENCLOSURE NOTES 1) Enclosure Ratings: Nema-4X / IP 65 2) Enclosure Material: 7.087" 180mm 6.496" 165mm Polystyrene base and cover, hinged transparent door with push-release latch. 3) Knockouts: 6.575" 167mm 7.165" 182mm 4.33" 110mm Pg 13,5 (.825" dia.) Pg 16 (.90" dia.) Pg 21 (1.15" dia.) Pg 29 (1.50" dia.) #80-0009 BATTERY BACKUP ENCLOSURE Page 6 of 14

Series A14 GasSens - System Enclosure Dimensions #80-0007 THREE MODULE ENCLOSURE (STANDARD) #80-0033 THREE MODULE ENCLOSURE (DEEP) Page 7 of 14

Series A14 GasSens - System Enclosure Dimensions #80-0008 SIX MODULE ENCLOSURE (STANDARD) #80-0027 SIX MODULE ENCLOSURE (DEEP) Page 8 of 14

Series A14 GasSens - System Enclosure Dimensions #80-0024 NINE MODULE ENCLOSURE #80-0026 TWELVE MODULE ENCLOSURE Page 9 of 14

Series A14 GasSens - Receiver Enclosure - Installation SURFACE MOUNT INSTALLATION (4) #6/#8 PHMS, S.S. or (4) #6 WOOD SCREWS (4) #6/#8 HEX NUTS, S.S. NOTES 1) Screws are inserted into blind recess in corners of enclosure. Cover must be removed for access to screw recesses. 2) Mounting template supplied for mounting hole locations. 3) All mounting hardware is supplied by customer. 4) Receiver and Transmitter enclosures are mounted in the same fashion. 5) For outdoor installations, a sun shade is recommended. REMOVING KNOCKOUTS 1) To remove knockouts, place a thin bladed screwdriver into the circular slot or the desired knockout size and tap firmly with a hammer. MOUNTING/REMOVING RECEIVER MODULES 1) Mounting of receiver modules is done by clipping them to a standard 35 x 7.5 mm DIN rail. A spring loaded clip holds the module to the rail and is used for mounting and removal. From the front, the clip is seen as a black loop at the top rear of the module. To remove from a rail, place a small screwdriver into the opening in the black loop and pull outward until the module releases from the rail. Reverse the procedure to mount the module. Analytical Technology, Inc. Page 10 of 14

Series A14 GasSens - Transmitter Enclosures - Dimensional A11 SENSOR / TRANSMITTER NOTES 3.70" 94mm 3.11" 79mm 1) Enclosure Ratings: Nema-4X / IP 66 2) Enclosure Material: Polystyrene base and cover, Standard Gray 3.70" 94mm 1.10" 28mm 3) Knockouts: Pg 11 (.75" dia.) Pg 16 (.90" dia.) 2.24" 57mm 3.11" 79mm A11 SENSOR / TRANSMITTER WITH AUTO-TEST GENERATOR 3.70" 94mm 3.11" 79mm 3.70" 94mm 2.72" 69mm 2.24" 57mm 3.11" 79mm A11 SENSOR / TRANSMITTER - EXPLOSION-PROOF NOTES 3/4" NPT 4.73" 120mm 6.07" 154mm 3.75" 95mm 2.88" 73mm 1) Enclosure Ratings: CLASS I, GROUPS B,C,D CLASS II, GROUPS E,F,G CLASS III 2) Assembly is normally mounted directly to suitable explosion-proof conduit. 3) To maintain the integrity of the transmitter, explosion-proof conduit and cable entry seals are required by local electrical codes. 3/4" NPT.75" 19mm Page 11 of 14

Series A14 GasSens - General Diagrams A11 TRANSMITTER w/ A10 SENSOR CALIBRATION ADAPTER ATI-0464 A11 TRANSMITTER w/ A10 SENSOR FLOWCELL ASSEMBLY ATI-0463 Page 12 of 14

Series A14 GasSens - General Diagrams X-PROOF TRANSMITTER w/ C10 SENSOR CALIBRATION ADAPTER ATI-0466 X-PROOF TRANSMITTER w/ C10 SENSOR FLOWCELL ASSEMBLY ATI-0465 Page 13 of 14

Series A14 GasSens - Transmitter Installations CABLE GLAND INSTALLATION NOTES FROM RECEIVER A11 SENSOR/TRANSMITTER 1) Mount Transmitter to wall with screws inserted in blind mounting holes, (accessible with cover removed. 2) Cable gland supplied uses Pg 11 knockout. Use extreme care in removing knockout. Score inside of concentric knockout with razor knife. 3) Sun shade is recommended for outdoor applications. CABLE GLAND SUPPLIED BY ATI CONDUIT MOUNT INSTALLATION 1) Transmitter may be supported by conduit or screwed to wall through blind mounting holes. 2) Sun shade is recommended for outdoor applications. A11 SENSOR/TRANSMITTER ½" CONDUIT ½" CONDUIT ADAPTOR SUPPLIED CONDUIT ENTRY MUST BE SEALED WATER-TIGHT REMOVING KNOCKOUTS 1) To remove knockouts, place a thin bladed screwdriver into the circular slot or the desired knockout size and tap firmly with a hammer. 2) Remove Transmitter PCB prior to removing knockouts, to prevent damage to the PCB. Page 14 of 14