DELTA reflex motion detector IP55

Similar documents
Unpack, connect, done - no further work required

1. Basic safety information 3 2. Proper use 3

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

User Manual 120/240/300 Outdoor Motion Detector

Product and Applications Description

18/2 General. 18/4 Dimensional Drawings N. 18/7 Switches and Pushbuttons. 18/14 Socket Outlets. 18/16 Dimmers. 18/31 Motion Detectors

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

Dimming expertise LED UNIVERSAL ROTARY DIMMER

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

Short form catalogue Domestic equipment Movement detectors

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

1. Basic safety information 3 2. Proper use 3

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

2. Safety. 4. Function

Movement controller comfort, Flush-mounted (Up) xx, xx

Devices for Special Applications

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

Detailed operating instructions

Gira Sensotec / Gira Sensotec LED Motion detector, orientation light and contactless switch in one

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

DALI MSensor 02 Multi-sensor for DALI system

PRODUCT CATALOGUE LIGHT CONTROL Grässlin products for the intelligent control of light

A watchdog that never sleeps.

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

UP 258E11 OPTISENS OFFICE

DALI MSensor 02 Multi-sensor for DALI system

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

Busch-Watchdog presence. Overview and applications of presence detectors.

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

SMARTER BUILDING. Busch-Presence detectors Energy saving the easy way

Detailed operating instructions

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

ad notam LED INTELLIGENT DIMMER INSTALLATION GUIDE Art.No. ET_548

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

360º Surface Mount Ceiling PIR Light Controller

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

ST Wiring diagram. Product description. Standard temperature controller. Order number

LED HIGH BAY LINEAR ECO SERIES

Connections, displays and operating elements C D E G H. Installing the control unit

OpenStage M3 Family Reliable, seamless connectivity in any environment

Increased safety and reducing energy consumption with the motion control RPI 01

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Tebis application software

LUX Hardwired - Installation Notes

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

ANSWER YOUR DOOR ANYWHERE. WITH DOORBIRD YOU NEVER MISS A VISITOR.

The Power To Supply... All Your Electrical Products

Lighting & Controls Motion & Presence Detectors

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

LIGHT SYSTEMS CATALOG

BOS 23K. Photoelectric Sensors BOS 23K

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

KNX PHASE I 43 PHASE II 45 PHASE III 46 PHASE IV

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

Operating Instructions. Digital Radar Motion Detector With Infrared Remote Control MWD BF. Hörmann KG Verkaufsgesellschaft

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

SITRANS T temperature transmitters A broad product family for every application. sitrans

Operating instructions

360 Surface Mount Ceiling PIR Light Controller

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Passive infrared ceiling sensor

60W Multi PIR Bulkhead

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Tri-level Control Sensor

1. Basic safety information 3 2. Proper use 3

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

2 equally Round sliding door systems with always 2 automatically half round-sliding doors

GAMMA. Applications in Office Buildings. Answers for infrastructure. Economically efficient and prepared for the future with GAMMA instabus

REA22 Room Temperature Controller

LED Lighting. Solutions

Presence, Motion, Control New Products 2014

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

IR FLAME DETECTOR RIV-601/F

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

Ionisation single-tube smoke detector for duct mounting

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

Built-in HF Sensor for High Bay

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

Swing Door Operator DORMA CD 400

OPERATING INSTRUCTIONS

G4S SMARTalarm User Guide

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

compact office 24V compact office 24V Lux

360 Ceiling PIR Light Controller

SITRANS F M MAG 3100 P:

IP65 High Bay Dual Sense Sensor

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Alarm System SECURE AS 302

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Technical data lumina MS4

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Transcription:

DELTA Switches and Outlets DELTA refle motion detector IP55 Quick and easy installation via plug-in terminals Advantages Simple mounting via plug-in terminals Automatic test mode when the rated voltage is applied for the first time Standard set values two minutes ON period and 7 lu brightness Fast set-up via two buttons Fleible implementation: wall, ceiling, or corner installation Attractive price/performance ratio Attractive design Available in colors titanium white or anthracite Supplemental functions via remote control for model 290 IR Electrical Installation from A to Z The new DELTA refle motion detector IP55 is characterized by its attractive design. It can be installed quickly and easily thanks to the plug-in terminals in the mounting base. The motion detector is adjusted automatically or via the two buttons on the device. This makes start-up quite simple. The DELTA refle motion detector IP55 is available for two different detection areas: 120 and 290. The 290 version is also available with remote control. www.siemens.com/delta

Installation with Plug-in Terminals Convenient wiring is possible thanks to installation with plug-in terminals. Installation steps: 1. Installing and wiring the connection bo The first step is to install and wire the connection bo. Afterwards, wiring can be eecuted in a simple manner. 2. Mounting the motion detector The second step is to simply plug the motion detector onto the connection bo. The three connecting pins establish the connection between the motion detector and the connecting wires. 3. Attaching the motion detector The third step is to screw the motion detector onto the connection bo. This ensures protection class IP55. Attaching with a screw makes undesired removal or theft of the motion detector more difficult. One, two, three... that s it! Three steps to install and the motion detector is ready for service. Configuration with two buttons Easy and convenient configuration and start-up of the motion detector via two buttons located behind the lens.

Remote Control With the remote control, which is included with the motion detector 290 IR, the following functions are possible. Holiday function/ Presence simulation Light 4 h ON The holiday function is a fied ON/OFF profile which simulates the presence of the inhabitants. The ON/OFF profile is activated for appro. 4 hours with the beginning of dusk. Shuts the motion detection off and switches the light for 4 hours permanently ON. OFF function Light is permanently OFF, motion detection is deactivated. Test function Activation of the test function for 10 minutes (brightness-independent, 1 second ON and 2 seconds OFF). Standard mode By pressing this button, the operating modes of the blue buttons are quit and the formerly set operating mode is activated once again. Save brightness-/ dusk-settings With this function, the already set brightness factor is replaced with the currently detected brightness factor. Brightnessindependent day mode The motion detector is also activated during day time independent from brightness. Set overrun time (start and stop time recording) With this button, the individual overrun time, ranging between 5 seconds to 30 minutes, can be programmed. Overrun time 10 min. Impulse function This function can be chosen when the motion detector is used with individual settings (standard operating mode) or in brightness-independent mode (day mode). The currently set delay time will be replaced. Impulse mode for 1 second ON, 9 seconds OFF. Options for use e.g. for staircase time switches, doorbells. Programming button For the programming of the yellow-button functions it is always necessary to press the programming button. Reset button The reset function can be used while in any operating mode (also in OFF function) and switches the motion detector back to factory settings (7 Lu / ON period 2 min.).

Technical Data DELTA refle motion detectors IP55 Variants DELTA refle motion detector 120 DELTA refle motion detector 290 DELTA refle motion detector 290 IR MLFB titanium white (similar to RAL 9010) 5TC7 210 5TC7 212 5TC7 214 anthracite 5TC7 211 5TC7 213 5TC7 215 Incl. remote control Technical data Protection class IP55 IP55 IP55 Detection area 120 290 290 Connected load 1000 W 5AX 2500 W 10AX 2500 W 10AX Load Bulbs 1000 W 2500 W 2500 W HV halogen bulbs 1000 W 2500 W 2500 W Fluorescent tubes 8 58 W 20 58 W 20 58 W Energy-saving bulbs ma. 4 ma. 8 ma. 8 Terminals for rigid conductors 1 mm² 4 mm², ma. 2 2.5 mm² fleible conductors 1 mm² 2.5 mm², ma. 1 2.5 mm² Range at 22 C 10 m 16 m 16 m Mounting height 2 4 m 2 4 m 2 4 m Wall or ceiling mounting Surface mount model with plug-in terminals, detector is simply plugged onto the connection bo after convenient wiring Mounting with special base Features Rear field detection Control via opener button Light ON (delay time), Continuous ON (4 h), Light OFF (back to normal mode) here only light ON (delay time) possible Pulse mode (1 s ON, 9 s OFF) Ambient light suppression (glare protection 60 s) Switching error suppression Range stabilization Presence simulation/vacation function After twilight 4 h permanently programmed ON/OFF profile in 24 h rhythm Wall and ceiling mounting Remote control Generous wiring area Numerous cable entries Convenient installation by plugging the detector onto the mounting base Convenient detector adjustment via 2 button operation Automatic set-up adjustment the first time voltage is applied Convenient two-button operation: Saves desired brightness value Saves desired delay time between 5 s and 30 min Changes to brightness-independent mode and pulse mode Reset values 7 lu and 2 min ON period Test mode to check the monitoring range

Installation There are three different ways to install the motion detector: Wall installation Ceiling installation Inside corner installation and outside corner installation Adjusting and reducing the detection area The detection area can be changed by turning the lens to the left or right + / 30. The detection range can be changed by adjusting the swivel arm. The motion detector has a cover blind that can be used to limit the detection area. It is necessary to cut out the cover blind accordingly to do this. Adjust the detection area by cutting out the cover blind

DELTA Switches and Outlets Product Order No. PU (unit) DELTA refle motion detector IP55 120 titanium white 5TC7 210 1 120 anthracite 5TC7 211 1 290 titanium white 5TC7 212 1 290 anthracite 5TC7 213 1 290 IR titanium white 5TC7 214 1 290 IR anthracite 5TC7 215 1 DELTA refle special base, for IP55 motion detector titanium white 5TC7 900 1 anthracite 5TC7 901 1 DELTA refle remote control, for IP55 motion detector 5TC7 902 1 The desired features are only binding if they have been epressly agreed when a contract is concluded. All product designations can be trademarks or products of Siemens AG or other supplier companies, the use of which by third parties for their own purposes can violate the rights of the owners. This product information contains only general descriptions or features that may not always apply in the specific application case in the form described, or that can change due to further development of the products. See catalog ET D1 for accessories and technical details. Siemens AG Automation and Drives Electrical Installation Technology P.O. Bo 10 09 53 93009 REGENSBURG GERMANY www.siemens.com/delta Siemens AG 2006 E20001-A5760-P440-X-7600 Update: http://www.siemens.com/delta Information subject to change without notice