ECONX FIT OFF INSTRUCTIONS

Similar documents
HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE


QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Property of Monitronics Inc

Sentry 4 Zone Alarm Panel User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Installation & Programming Guide

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

RINS App User Guide. Connect to your home or business from anywhere in the world.

TRX MAINS CONNECTION DIAGRAM

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

LS800S Intruder Alarm System. Engineering Manual

CHEAT SHEET: SPECTRA V2.1

User s Information Guide R2A

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

AXI LED USER MANUAL (REV. 1.0)

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Power Wave Zone Alarm Panel V8.5. Installation Manual


User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

DCS2000 DEMENTIA CARE SYSTEM USER GUIDE. For Software Version 1.2 1

A Beginners Guide to Inner Range Systems

TABLE OF CONTENTS TABLE OF CONTENTS 1

CC408. Quick Reference Guide Solution 880

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

abode Web app Functionality

D3D Wi-Fi GSM Smart Alarm System -User Manual

EC-P Zone Intruder Alarm System

4-PGM Expansion Module

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide


IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

User Manual. Alarm system: PhoneWatch TC

INSTALLATION MANUAL PC15OO

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

DSC PowerSeries NEO Quick Start Guide

HILLS RELIANCE 4 ALARM SYSTEM 4 zone panel

User's MANUAL A$ Rev 1.4

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

NextGen Home Security. Quick Reference Guide

End To End Optical Beam Smoke Detector. Additional Information

2200 and 2200L ALARM CONTROL SYSTEMS

POWERBRICKALARM TCP/UDP IP Alarm Panel Installation and Operation Manual

CC488. Quick Reference Guide Solution Ultima 880

Security Alarm System Owner's Guide 8 sector CDS Dialler 8-24 sector Control Dialler 8-24 sector Control Securitel Version 1.0 lcopm.

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

USER MANUAL CEF AP28 CONTROL PANEL

INSTALLATION MANUAL DV8OOO. Software Version 1.0

Data Sheet. Abacus intruder alarm systems

VAP304 PRO INSTALLATION & OPERATION MANUAL

Control/Communicator Installation Manual

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

LUX Hardwired - Installation Notes

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

POWERBRICKALARM. User Manual. For Customers PB300. Version 1.36b

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

VISTA 48DLCT HONEYWELL SECURITY

Comfort Applications Manual

8-zone Expansion Module

Model 17A00 Expansion Enclosure

SCORPION Z16040C, Z8040C and Z5120C

IDS816 User Manual H Issued January 2009

Security System. User s Guide for the Text Command Center

Flair 500 Series Annunciators

User Guide. Contents. About this guide. i-on Style Security System

Sync. Smart Home Alarm

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

RE6100 Series Helix Security and Automation Platform

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

L900 series USER MANUAL

NEW GENERATION WIRELESS ALARM SYSTEMS

New generation wireless alarm systems

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

NetworX NX-8V2. LED Keypad User Manual

Watchguard WGAP864 User Manual

>WIRELESS> ALARM SYSTEM CR200

NESS D8 CONTROL PANEL AND DIALLER

General Purpose IO Technical Manual

Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected,

HARDWIRED CONTROL PANELS

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

SERENITY. Crow s Passion for Smart Residential Security.

Property of Monitronics Inc

ALARM MATE NEWSLETTER SEPTEMBER 2013

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

Installation Manual Premier 412/816/832. Issue 10

System Introduction. 1.1 Specifications

ELT-KLED EliteSuite LED Keypad Installation Manual

10-Zone Spectra LED Keypads

Digiplex LED Keypads User s Manual

LCD and 16-Zone LED Keypads. User s Manual

Transcription:

ECONX FIT OFF INSTRUCTIONS 0 1. Labelling 2. Fit Off Alarm Sensors 3. Fit Off Smoke Sensors 4. Fit of Siren and Sounder 5. Partitioning, Night Arm and Panic Buttons 6. Fit Off Temperature Sensors 7. Fit off Light Switch s 8. Fit Off Dedicated Circuits 9. Heat Pumps 10.Garage Doors Gates Front Doors 11. Electric Blinds/ Windows 12. Support

FIT OFF - LABELLING 1 To ensure commissioning is straight forward we recommend completing the form included in the instructions and following your project scope. Alarm circuits must be identified so Entry and Exit delays can be applied. Temperature sensors must be clearly identified to ensure the correct probe will be controlling the required circuit. Relay Controls Relay 1 Hot water cylinder Relay 2 Instant Water Heater or In Floor Heating Relay 3 Under tile Heating Ensuite Relay 4 Under Tile Heating Bathrooms Relay 5 Heated Towel Rails Relay 6 Outdoor Entry Lights Relay 7 Indoor Night Relay 8 Relay 9 Security and Safety 1 Smoke or Sensor Smoke - Hallway 2 Smoke or Sensor Smoke - Hallway 3 Smoke or Sensor Smoke - Living 4 Smoke or Sensor PIR- Entry 5 Smoke or Sensor PIR Garage 6 Smoke or Sensor PIR Laundry Door 7 Smoke or Sensor PIR Hallway 1 8 Smoke or Sensor PIR Hallway 2 9 Smoke or Sensor PIR Master Bedroom 10 Smoke or Sensor 11 Smoke or Sensor 12 Smoke or Sensor Panic Button Key Switch Temperature Input 1 Bathroom Temperature Input 2 Ensuite Access Control/ Misc. 0 Garage Door Control/ Misc. 1 Automatic Gate Control/ Misc. 2 Blinds Up Control/ Misc. 3 Blinds Down Control/ Misc. 4 Control/ Misc. 5 Control/ Misc. 6 Control/ Misc. 7 Control/ Misc. 8 Heating and Cooling IR Output 0 Heat Pump Living IR Output 1 Heat Pump Hallway IR Output 2 IR Output 3 IR Output 4

FIT OFF PIR SENSOR 2 We recommend one sensor per zone. If additional inputs are required we suggest doubling up the smoke detector zones. Alarm sensors require a positive, negative and an input into the Econx. Common practice is the 4 wire method. Econx provides the option of 24hr monitored tamper with separate wiring of the tamper input. End of Line Resistors (EOL) must be a minimum of 1K. Econx recommends 2K - 10K. Econx will learn whatever is installed, different resistors throughout a single installation is acceptable.

FIT OFF SMOKE 3 We recommend one sensor per zone. These require a positive, negative and a input into the Econx. Common practice is the 4 wire method. End of Line Resistors (EOL) must be a minimum of 1K. Econx recommends 2K - 10K. Econx will learn whatever is installed, different resistors throughout a single installation is acceptable. Econx prefers the resistors are installed in parallel with the N/O contact. This provides the ability to fault find should you have damaged wires or a faulty smoke detector.

FIT OFF OUTDOOR & INDOOR SIREN 4 Please Note the siren and strobe are wired separately. The Strobe will flash when disarming and arming as a visual indicator. The tamper is 24hr monitored and no other configuration is required

FIT OFF PARTITIONING, NIGHT ARM & PANIC 5 Partitioning/ Night Arming and disarming is typically operated by the clients smart phone App. Manual push buttons can be installed if preferred. Key Switch input This can be used to Arm and Disarm the system. This is a momentary action. Should this feature be used no personalised logging is possible.

TEMPERATURE SENSOR CONNECTION 6 Econx is pre-configured to operate with 1. DEVI floor, indoor and outdoor temperature sensors. 2. Hot wire 10K and 100K under tile heating probes Any of the Smoke 1 3, PIR 1 9 plus AIN 1 & 2 can be configured as a Temperature inputs. One room sensor can be used to control multiple outputs E.G One Living Room sensor could control a) In-slab Heating b) Heat Transfer c) Electric Blinds d) Electric Windows

FIT OFF LIGHT SWITCHES 7 Econx recommends Auto/ Manual/ Off Mechs are installed for all lighting loads connected to Econx, This provides manual operation and the ability to isolate when required. N/O wiring into Econx is recommended. This ensures lights will be off if the Econx system is isolated. Outdoor Motion sensors can be installed in Parallel with Econx Econx will NOT be effected by parallel switching. Light switches, where auto/man/off is NOT available in the selected range you can either 1. Wire Econx relay in parallel with light switch this may cause confusion with client 2. Install auto/man/off mech in garage by Econx panel or in a discrete and practical location 3. Install a LV press mech and wire into a Econx Misc. input. This provides app and manual control

FIT OFF DEDICATED CIRCUITS The following is recommended to ensure operation before commissioning and protection from nonessential heating loads be left On. 8 Econx recommends N/C connection is used for the following a) Hot water b) Heated Towel Rails c) Pool Pumps d) Water Features Econx recommends N/O connection is used for the following a) Under tile Heating b) In-Slab Heating c) Heat Transfer Econx recommends Auto/ Manual/ Off Mechs are installed for all lighting loads connected to Econx, This provides manual operation and the ability to isolate when required. This is a recommendation only, Econx provides configuration for either N/O or N/C

FIT OFF HEAT PUMPS Heat Pump control is via infra red, Each Econx can control up to 5 zones from one system. The Econx software includes most major brands IR codes, new models and other brands can be added at any time. 9 Functionality includes a) On/Off b) Heating and Cooling c) Set Temperatures d) Automation of Operation Testing Should your system not operate straight away and the codes on the remote do not match any in the system we will require the remote to load codes onto Econx. We encourage to test before shipping the remote to us. To Test Hold Down Buttons 1 and 4 in the middle of the Econx panel, you will see 5 LED s flash On then Off. Go to indoor unit and look at IR emitter using the cameras on the phone, you should see it flash on then off. Please call with questions 0800 12 33 12

FIT OFF GARAGE DOORS, GATES & FRONT DOORS 10 These 9 miscellaneous inputs and outputs can be configured to operate Garage Doors, Automatic Gates, Mortice or Mag Locks, Electric blinds, Irrigation and. The inputs and outputs are linked within the Econx software. PLEASE NOTE Inputs and outputs must correspond Example 1 Garage Door Motor = Relay 0 Garage Door Reed Switch = Input 0 Example 2 Auto Gate Motor = Relay 1 Auto Gate Reed Switch = Input 1

FIT OFF ELECTRIC BLINDS AND WINDOWS These 9 miscellaneous inputs and outputs can be configured to operate electric blinds and windows. 11 Functionality includes full opening and closing via the browser, smart phone app and schedules. Manual push buttons are installed for part opening and closing. Should more than 3 4 zones be required we recommend the installation of the manufactures controls along with a group controller, Econx will provide automation and room/zone control. PLEASE NOTE Inputs and outputs must correspond Example 1 Blind motor up Zone 1 = Relay 5 Manual button up = Input 5 Blind motor down Zone 1 = Relay 6 Manual button down = Input 6

SUPPORT 12 More wiring Information a) Wiring diagrams are supplied with your Econx system and are available at www.econx.co.nz/technical-information b) Step by Step Fit Off and Configuration Guides are available at www.econx.co.nz/technical-information Support Contact Anthony Tucker sales@econx.co.nz PH 0272 666 329