MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

Similar documents
IPAC. Invicta Precision Air Control Floor Standing Range

CHILLED WATER DATA ROOM UNITS

8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW. Typical applications

Flexible & Innovative. Cooling Solutions

gforce Units Data Aire and Data Temp Series

Outstanding Performance; Application Flexibility

Appendix 13. Categories of Cooling and Heating systems

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

RHC GAS FIRED HEATING COILS

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

Printed 2000, replaces all previous editions PAK.5231 PAK.5232 COOLING UNITS FOR CLIMATE CONTROL, COMMERCIAL REFRIGERATION AND INDUSTRIAL APPLICATIONS

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

60 Hz. Catalogue_2016 REFRIGERATION UNITS. - Commercial Range -

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Air Cooled Scroll Chiller

IPAC Air Handling Units

PRODUCTS. Configurable Packaged Air Handling Equipment VRC SERIES

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Chilled Water Precision Air Conditioner for Critical Application

SysTemp NEW. Close Control Engineering Data Manual

Design, Construct, and Operate to Control Indoor Humidity

Close Control Air Cooled Twin Circuit Range

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

Mission Critical Air Conditioning Systems

IDU22C, 22C1, 37C, 37C1, 55C, 75C

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

2013 Product Range Precision Air Conditioners (CRAC)

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

next evo cw next evo cw rcgroupairconditioning

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

KOMPAKT. Air Handling Units

COTES ALL-ROUND THE C35 RANGE

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Refrigerated Air Dryers

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Patent Pending CO 2 OLrac. Blade Server Cooling

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

ABBE LEVEL 4 DIPLOMA IN AIR CONDITIONING ENERGY ASSESSMENT ABBE LEVEL 4 DIPLOMA IN AIR CONDITIONING ENERGY ASSESSMENT (QCF)

Dry desiccant dehumidification systems. Product guide

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons

Refrigerated Air Dryers

Denco has been producing and installing. equipment specifically designed for the precise. control of air temperature, humidity and quality

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Computer Room Air-Conditioning 60 Hz. Technical Data

InRow Direct Expansion

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

Heat pump and energy recovery systems

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

BENSON.... Variante3 Fired Unit Heaters...

COTES ALL-ROUND THE C35 RANGE

F Series - Refrigeration dryers

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

Refrigerated Air Dryer

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

pyxis pyxisa NEW rcgroupairconditioning

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Flexible and efficient: Close Climate Control for IT equipment

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Rotary Screw Compressors BSD/CSD/CSDX T SFC Series

30RB /30RQ

Series PS6, Vertical Floor-Mount Units

New standard in compressed air treatment, providing Energy Savings up to 99%

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

Refrigerated Air Dryer

DOMEKT. Residential ventilation units

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

within a Quality Management System ISO9001 and Environmental Management System ISO Sales Offices CERTIFICATION

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

Condensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units...

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

PYXIS U PYXIS U. rcgroupairconditioning

Air-Handling System Cooling Options

MECHANICAL SERVICES 101. Ian White

Refrigerated Air Dryer

RIGID DC LIQUID CHILLER

pyxis u pyxis ua NEW rcgroupairconditioning

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Precision Air-Conditioning Units 60 Hz. Technical Data

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Industrial cooling solutions

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

DRYMODULE HEAT EXCHANGER

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

DC Inverter Chillers & DC Fan Coil Units

Refrigerated Air Dryers

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Transcription:

MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS

T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a compact footprint, but without compromising the critical application of data centre cooling. This downflow range of air conditioning units are available in X air cooled, water cooled or chilled water media with optional glycol cooling. ll configurations have energy reduction features as well as heating or humidification options. The RU Range has been designed around a modular frame and panel design providing maximum unit strength as well as all round access where applicable. However, all maintenance and service has been designed for front access only where site restrictions dictate. The units are designed to take return air at a high level which is then filtered and conditioned before being discharged via the base fan section located in the ventilated raised floor. Multiple high efficiency direct drive fans provide even, efficient air supply and inherent redundancy. lternatively, the units can be fitted with speed controllable E fans. ll X units are supplied with twin compressor -stage cooling, whilst chilled water units provide stepless 0 to 100% cooling. Where applicable glycol economy cooling coils can be coupled to dry coolers or economy cooling chillers to maximise efficiency and minimise running costs. Where required, the units can be supplied with electrode boiler humidifiers providing high efficiency stepless output of sterile steam, and electric heaters are available in case of reheat requirement. Features Multiple key components share system loads: Vertical HU frame and panel construction: Modular split fan / coil sections: Underfloor multiple backward curved fans: enefits Increased efficiency and reduced system impact in the unlikely event of a key component failure. ll round access and high unit strength and rigidity. Ease of installation. Efficient air distribution. Model RU8 shown. Hydrophilic coils: Modular component assembly: Fully programmable controller: ustomised control systems: Long life and efficient moisture removal. esigned for easy and quick component maintenance/ replacement. ustomised programming and network capabilities. Ease of integration for existing site upgrades.

UNIT FETURES 1 3 1. Fan Section.. Electrical Section. 3. ompressor Section. RU

TEHNIL SPEIFITION Model RU8 RU10 RU1 X SYSTEM Total ooling kw 7 97 10 Gross Sensible ooling kw 1 85 9 Net Sensible ooling kw 5 75 85 HILLE WTER SYSTEM Total ooling kw 81. 98. 1. Gross Sensible ooling kw 73. 9.8 11. Net Sensible ooling kw 70.9 89.1 108.7 IR MOVEMENT ir Volume m³/s (m³/h).5 (170) 7.0 (500) 7.0 (500) esign External Pressure rop Pa 0 0 0 Number of Fans 3 3 Nominal Power onsumption (per Fan) kw.5.5.5 REFRIGERTION Number of ompressors Refrigerant R07c R07c R07c HETING Stages apacity (per Stage) kw 7.5 7.5 7.5 HUMIIFITION Humidifier Electrode oiler Electrode oiler Electrode oiler Humidification apacity Kg/hr 15 15 15 RU INOOR UNIT imensions (Including Fan ase) Width Height epth mm 1700 3090 1090 0 3090 1090 0 3090 1090 Filtration EU EU EU Unit Weight** Kg 78 91 93 Fan ase Weight Kg 3 335 335 INO X ONENSER OUTOOR UNIT ondensers INO - INO - INO 3- imensions Width Height epth mm 07 1100 105.5 07 1100 105.5 3507 1100 105.5 Weight Kg 170 10 0 POWER SPEIFITION FOR LL SYSTEMS Power Supply V/PH/Hz 00/3/50 00/3/50 00/3/50 POWER ONSUMPTION IR OOLE ooling Only Unit (Fans & ompressors) a/phase 5.5 7.5 88.5 Temperature Unit (Fans, ompressors & Heaters)* a/phase 5.5 7.5 88.5 Full Unit a/phase 75.5 89 110 POWER ONSUMPTION WTER OOLE ooling Only Unit (Fans & ompressors) a/phase 51 8 Temperature Unit (Fans, ompressors & Heaters)* a/phase 51 8 Full Unit a/phase 75.5 89 103 POWER ONSUMPTION HILLE WTER ooling Only Unit (Fans & ompressors) a/phase 1 17 17 Temperature Unit (Fans, ompressors & Heaters)* a/phase 3 39 39 Full Unit a/phase 55 0 0 Notes X Unit cooling duties are based on º / 5% Relative Humidity / 35º mbient. hilled Water (W) Unit cooling duties are based on º / 5% Relative Humidity and º Flow / 11º Return. *No humidity control. **X ir ooled Unit.

ONTROLLER The RU is fitted with a fully programmable unitary controller complete with display/user interface. The controller monitors the temperature and relative humidity of the return air and activates cooling humidification or dehumidification to provide precise and efficient conditioning of the supply air. dditionally, the controller monitors the in-built safety devices of the unit which constantly ensure the healthy state of key components. In the unlikely event of a component malfunction the item is automatically isolated to enable the plant to continue running, and an alarm signal will be generated. Where required, multiple units can be networked together to provide group or run/standy control. Units can be monitored locally or remotely, and if required, an enhanced web enabled controller can be supplied, providing password restricted access from a suitable Internet access point. ontrol Features Fully programmable. ata logging. Standalone or group control. MS interface. Remote monitoring. Energy saving control strategies. Monitored Information and larm Points Temperature. Relative humidity. irflow. Filter condition. Refrigerant monitoring. Water detection. Humidifier status. Heater status. Fire shutdown. VF relay alarms. Smoke detection.

SYSTEM SELETION ir ooled The air cooled X system circulates refrigerant to absorb heat from the conditioned space at the indoor unit, which is then rejected at the external air cooled condenser. Twin evaporator coil / compressor circuits with multiple supply fans, provide redundancy with four stages of cooling and are coupled to two individual low noise level air cooled condensers, complete with fan speed controls. Optional humidification control can be provided by an electrode boiler humidifier, and optional heaters provide reheat where required during dehumidification mode. Water ooled The water cooled X system circulates refrigerant to absorb heat from the conditioned space at the indoor unit, which is then rejected via an external dry cooler or similar. Twin evaporator coil / compressor circuits with multiple supply fans, provide redundancy with four stages of cooling and are coupled with an individual plate heat exchanger for water cooled heat rejection, complete with three port head pressure control valves. Optional humidification control is provided by an electrode boiler humidifier and optional heaters provide reheat where required during dehumidification mode. Water ooled with Glycol Economy ooling The water cooled X system circulates refrigerant to absorb heat from the conditioned space at the indoor unit, which is then rejected via an external dry cooler or similar. Twin evaporator coil / compressor circuits with multiple supply fans provide redundancy with four stages of cooling and are coupled with an individual plate heat exchanger for water cooled heat rejection, complete with three port head pressure control valves. n additional glycol cooling coil provides low energy cooling when ambient conditions dictate. Optional humidification control is provided by an electrode boiler humidifier and optional heaters provide reheat where required during dehumidification mode. hilled Water The chilled water system circulates water to absorb heat from the conditioned space at the indoor unit which is then rejected at the external chiller. Twin cooling coil with multiple supply fans provide fully modulating 0 to 100% cooling complete with two or three port control valves. Optional humidification control is provided by an electrode boiler humidifier and optional heaters provide reheat where required by the dehumidification mode.

SYSTEM ONFIGURTIONS ir ooled 1 5 3 7 Key 1 3 5 7 Internal RU unit Internal fan base section Refrigerant hot gas discharge line Refrigerant liquid line ontroller External air cooled condenser Fan speed controller Water ooled 1 5 7 3 Key 1 Internal RU unit 3 5 7 Internal fan base section ry cooler return water ry cooler flow water ontroller External dry cooler Water cooled condenser control valve* * The valves depicted are purely shown schematically and are physically located within the unit.

SYSTEM ONFIGURTIONS Water ooled Glycol Economy ooling 1 5 8 7 3 Key 1 3 5 Internal RU unit Internal fan base section ry cooler return water ry cooler flow water ontroller 7 8 External dry cooler Water cool / Glycol cool selection valve* Water cooled condenser control valve* hilled Water 1 7 5 3 Key 1 Internal RU unit 3 5 7 Internal fan base section hilled water flow pipework hilled water return pipework hilled water controll valve* ontroller hiller * The valves depicted are purely shown schematically and are physically located within the unit.

UNIT IMENSIONS RU8 RU10 310mm 310mm Standard floor level Standard floor level Minimum floor level 780mm 50mm Minimum floor level 780mm 50mm 1700mm 0mm RU1 310mm Standard floor level Minimum floor level 780mm 50mm 0mm Note: ll RU units are 1090mm deep.

INO X IR OOLE ONENSER 07mm Twin Fan Unit 3507mm Triple Fan Unit 1100mm 1100mm Horizontal Mount (Vertical ir Flow) Elevation 1000mm 50mm 105.5mm Vertical Mount (Horizontal ir Flow) Elevation 1000mm

GROUP PROUTS & SERVIES Server abinets & Rear oor Heat Exchangers (RHx) Powerful cooling capacity, up to 30kW heat removed at source and rejected to water, not the room. ondense free operation using dew point controlled water from the U. hot swap fans variable speed. 80% front door venting. 1,000kg weight loading and full range of accessories. Easily installed via leak free quick release ¾" couplings and hose sets. 00mm wide 0kW cooling. 800mm wide 30kW cooling. U (ooling istribution Unit) Provides cooling water for up to rear door heat exchangers. ooling capacities of 100, 10 or 150kW with full run/standby capability (N+1). Internal manifold with leak free quick release couplings for easy installation and connection to the rear door heat exchangers via ¾" hose sets. hilled water connections (mm / 1½") via top or bottom. ew point temperature control of cooling water, internal W filtration. uto fill and bleed of coolant. Full alarm monitoring and connectivity. U Module The 0kW U Module is a u rack mountable, self contained cooling module capable of providing closely controlled cooling water above dew point to one or two rear door heat exchangers. Leak free, quick release couplings enable rapid install and connection to the rear door heat exchanger via ¾" hose sets. Features include dew point temperature control for condense free operation, uto fill and bleed of coolant, full alarm monitoring and connectivity. Modular U System dedicated cabinet to house up to U Modules to enable initial install to be completed allowing the perfect upgrade path. The cabinet houses power distribution and chilled water connectivity to the U Modules via manifold and couplings. Individual U Modules can then be simply plugged in as the data centre expands or heat loads increase. larms, room temperature and humidity data are managed through the central power distribution system giving one connection point for power and alarms. RU (R) Unit RU ata Room air conditioning units are designed for high density load areas where a large cooling duty is required, from a compact footprint, but without compromising the critical application of data centre cooling. 80/100/10kW cooling capacities. vailable in chilled water, X, X with water cooled condenser and glycol free cooling configurations. full range of options and ancillaries are available including inbuilt humidifier for room humidity control. IP (R) Unit IP floor standing air conditioning units are available in chilled water or X, cooling only configuration. 15-80kW cooling capacities available in various configurations including up flow or down flow air path, chilled water or X cooling. full range of options and ancillaries are available including inbuilt humidifier for room humidity control. hillers Energy efficient chillers up to a capacity of 00kW with the full run/standby (N+1) capability can be offered. These can also be fitted with free cooling capability and qualify for E (Enhanced apital llowance) under the arbon Trust Scheme. Grilles & iffusers Our extensive range of grilles and diffusers are available in a wide range of shapes and sizes and include floor grilles for server/data centres. Service & Maintenance ll types of HV heating, ventilating and air conditioning equipment are supported by our national network of mobile engineers or residential engineers for optimum operating efficiency. M&E Services Project design, installation and commissioning. Refurbishment. F and HF recovery and substitution. Humidification Specialist manufacturers of humidifiers and steam generation products. ir Handling Eaton-Williams design and manufacture air handling plant for commercial and industrial applications. pplications include hospitals, supermarket chains, leisure stadiums, pharmaceutical buildings and office complexes with uniquely designed solutions to suit each project.

PROUT RNGES omputer Room & ata entre ooling ir-cooled & Water-cooled Liquid hillers Packaged Roof-Top Units Full Range of ir Handling Units Fan oil Units Packaged Telecommunications Units Fresh ir Units ondensing Units ir ooled ondensers Low Temperature assettes ellar & Storage Low Temperature ooling Units Packaged In-Wall Units Stand-alone Humidifiers OEM Process ooling ontrol Units ustom esigned Packages onstant & Variable ir Volume Units marketing@dafnia.com www.dafnia.com U HI UI JFZ MUST OH 3 UE +971 5557351 +971 335995 +971 883101 OMN +98 75005 QTR +97 15053 3