FW-RA-LED Remote Multiplex Annunciator Panels

Similar documents
RR-PM1200 OPERATING AND PROGRAMMING GUIDE

RAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE

Using Your GEM-P400 Security System H

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

MR-2316-AT/Z Remote Annunciator

Using Your XP-600. Security System NAPCO NAPCO 2006 OI301B 4/06 1

Using Your GEM-P800 Security System

RA-1000 Series. Remote Multiplex Annunciator Panels. Installation and Wiring Manual

INSTALLATION INSTRUCTIONS

ADVANCED ADAPTIVE TM PIR/MICROWAVE TECHNOLOGY SENSOR

MGD-32 and AGD-048. Remote Multiplex Graphic Driver Annunciators and Adder Boards. Wiring and Installation Manual

RAX-LCD-LITE. Remote Annunciator. Installation and Operation Manual

CD6102 / CD6102 OC / CD6102-2

LMA LINE MONITOR ALERT USER S MANUAL

Using your NAPCO FREEDOM. F-TPG Garage Touchpad Home Security System NAPCO 2005 PATENTED OI309 10/05 1

* These Remote Mics must be SPRM-GP

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

CZ-6A Six Zone Interface Module

External Wireless Sounder

INSTALLATION INSTRUCTIONS and OPERATING GUIDE

OPERATING GUIDE for your GEM-RP3DGTL KEYPAD

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

installation & operation manual

Long Range Radio Alarm Transmitter

FW-KP WIRELESS KEYPAD

RAM-2644LCD. LCD Remote Annunciator. Installation Manual. Advanced Life Safety Solutions

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

Remote Relay Module (RRM)

KP600F/L LED/LCD KEYPADS. Owner's Manual. Use with AV6500 & SP850 Control panels

RAM-3500-LCD. Remote Annunciator. Installation and Operation Manual

Installation Instructions

PAD100-6DB & PAD100-4DB PAD100-PD

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

GETZ MANUFACTURING PART # CYLINDER DRYER

Section PERIMETER SECURITY SYSTEMS

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

OPERATION & INSTALLATION MANUAL

Long Range Radio Alarm Transmitter

INSTRUCTION MANUAL PC255O

External Wireless Sounder

Horizontal Bottle Cooler Installation and Operation Manual

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

INSTRUCTION MANUAL PC255O

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

EVD-1 Installation, Operation, and Instruction Manual

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

Protocol Station Remote Alarm

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Ice Cream Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Blade Series Heat Exchanger Operation and Installation

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Deluxe Discharge Alarm

Phone (516) Fax (516) web site

Installation and Operation Instructions 1000 Series Siren & Controller

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

SEALING FIBER SEALING COMPOUND

Duct Mount. Installation Instructions

Installation & Operation Manual

EVA-SCM-SCI Sounder Control Module

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Remote Sensor Module: EB-RSM-01

Single Station Remote Alarm

Installation and Operations Manual

Advantium 16 System Monitor

Spa Control System OWNER S MANUAL

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Instruction Manual EVA-S6 Base

OPERATING GUIDE for your GEM-DXRP3 KEYPAD NAPCO 2006 OI324 11/06

Multiplex Eight Input Remote Modules

8VHU*XLGH K4254V3 6/01

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

SC-6 Six Supervised Control Module

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

ion Genesis Pump Controller

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

4500 THERMOSTAT INSTALLATION INSTRUCTIONS

Propane Fume Detection System

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Macurco HD-11 Hydrogen Gas Detector

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

3820, 3820i, 4820, 4820i

DIGITAL FRONTIER Voice Alarm System DFA5300 User Manual Version 1 rev2

Installation & Operation Manual

Air Pump Up to 800 gallons

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

Model 4001 Series Single Channel Controller

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INSTALLATION MANUAL PC56O. Version 1.OA

OPERATION AND INSTALLATION MANUAL

Transcription:

FW-RA-LED Remote Multiplex Annunciator Panels WIRING and INSTALLATION INSTRUCTION LNOTICE All information, documentation, and specifications contained in this manual are subject to change without prior notice by the manufacturer. 1999 by NAPCO Security Systems, Inc. Printed July 22, 1999 LT-648NAP

INTRODUCTION: NAPCO s FW-RA-LED Annunciator is an 8 Circuit Annunciator for use with NAPCO s FW-C2Z, FW-C4Z, FW-C4EZ Fire Alarm Control Panels, that mounts into a standard 4-gang electrical boxes, which may not be expanded. Control access is by a keyswitch. Each Circuit Indicator is a bi-colour LED that is automatically configured to match the Fire Alarm Control Panel configuration. INSTALLATION INSTRUCTION: NOTES: Note that the FW-RA-LED is supplied with NP-386NAP Labels. This Annunciator displays Initiating Circuit Status only (no individual Circuit Troubles). Indicating and Relay Circuits are not remotely displayed. See the Fire Alarm Control Panel Manual for more details. The FW-RA-LED has a keyswitch to enable the four slide-switch controls. The key should be appropriately secured. 2

CONTROLS & DISPLAYS: For precise definitions of Control & Display operation, refer to the manual for the Fire Alarm Control Panel that the Annunciator is being connected to. Controls System Reset, Signal Silence, Buzzer Silence, Lamp Test. Displays AC On, Common Trouble, Signal Silence, 8 Circuit Status LED s. WIRING INSTRUCTION: The RS-485 Wiring to the FW-RA-LED Module is recommended to be Twisted Shielded Pair as shown in the diagram. The wire gauge may be; 22 AWG up to 2000 ft. 20 AWG up to 4000 ft. 18 AWG up to 8000 ft. The RS-485 wiring from the Fire Alarm Control Panel to the Annunciator(s) must be point-to-point from the FA Panel to the first Annunciator, then the next Annunciator, and so on. No star-wiring or T- tapping is allowed. Each RAM-208 Annunciator Module has a 120 ohm End-of-Line Resistor on its RS-485 Output terminals. This is removed on all except the last wired Module. The 24 VDC field wiring needs to be of an appropriate gauge for the number of annunciators and the total wiring run length. See the Specifications section Current Drain for Battery Calculations, and calculate the Maximum current for all Annunciators summed together... NOTE: Accidentally connecting any of the 24 VDC wires to the RS-485 wiring could result in damage to the Annunciator and/or to the Fire Alarm Control Panel that it is connected to!!! Maximum for MAXIMUM WIRING RUN TO LAST ANNUNCIATOR MAX. LOOP all Annunciators 18AWG 16AWG 14AWG 12AWG RESISTANCE Amperes ft m ft m ft m ft m Ohms 0.30 470 143 750 229 1200 366 1900 579 6 0.60 235 71 375 114 600 183 850 259 3 0.90 156 47 250 76 400 122 570 174 2 1.20 118 36 185 56 300 91 425 129 1.5 1.50 94 29 150 46 240 73 343 105 1.2 1.70 78 24 125 38 200 61 285 87 1.0 3

DIP SWITCH SETTINGS: Each Annunciator needs to be assigned a unique, sequential Address. This is done with DIP Switches, which also allow disabling of some buttons. SW1-1 = Address A0 \ SW1-2 = Address A1 > Address A3 is always off. SW1-3 = Address A2 / SW1-4 = When off, the System Reset and Signal Silence slide-switches are always disabled, regardless of the operation of the keyswitch. The Annunciator Address (see the Manual for the Fire Alarm Control Panel being used), is set as... Annunciator Address DIP Switch Positions 1 2 3 4 5 6 7 SW1-1 (A0) on off on off on off on SW1-2 (A1) off on on off off on on SW1-3 (A2) off off off on on on on SW1-4 (A3) off off off off off off off Annunciators on a common RS-485 connection must be numbered sequentially; i.e.: 1,2,3,4, and not randomly such as 5,3,7!! Note that not all Annunciator Addresses are valid for all Fire Alarm Control Panels. Refer to the Fire Alarm Control Panel Manual for further information. SPECIFICATIONS & FEATURES Enclosure: A standard 4-gang Electrical Box is used. Electrical Specs.: 19 to 31 VDC (filtered or full-wave-rectified) Slide-Switch Controls, LED indicators, and Keyswitch to enable Controls. Local Buzzer, Indicators (AC-On, Common Trouble, Signal Silence), and Controls (System Reset, Lamp Test, Buzzer Silence, Signal Silence). Annunciation of up to 8 Points. Not Expandable. Standby: 35 ma Max., All LED s On : 90 ma Max. Current Drain for Battery Calculations: The maximum normal current drain will be during Lamp Test when all lamps are illuminated on one chassis at a time. Thus the currents are... Normal Standby = 35 ma Maximum = 90 ma The Normal Standby Current is used for Battery Size Calculations (see the Fire Alarm Control Panel manual) and includes the current drain for the Trouble Buzzer, Trouble LED, and one Alarm LED. The Maximum Current is used to calculate the wire size (see the Wiring Instruction). 4

WARRANTY NAPCO SECURITY SYSTEMS, INC. (NAPCO) by the security professional, shipping costs prepaid and warrants its products to be free from manufacturing insured to NAPCO. After repair or replacement, defects in materials and workmanship for 12 months NAPCO assumes the cost of returning products under following the date of manufacture. NAPCO will, within warranty. NAPCO shall have no obligation under this said period, at its option, repair or replace any product warranty, or otherwise, if the product has been repaired failing to operate correctly without charge to the original by others, improperly used, abused, altered, damaged, purchaser or user. subjected to accident, nuisance, flood, fire or acts of God, or on which any serial numbers have been altered, This warranty shall not apply to any equipment, or any defaced or removed. NAPCO will not be responsible for part thereof, which has been repaired by others, any dismantling, reassembly or reinstallation charges. improperly installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any This warranty contains the entire warranty. It is the serial numbers have been altered, defaced or removed. sole warranty and any prior agreements or Seller will not be responsible for any dismantling or representations, whether oral or written, are either reinstallation charges. merged herein or are expressly cancelled. NAPCO neither assumes, nor authorizes any other person THERE ARE NO WARRANTIES, EXPRESS OR purporting to act on its behalf to modify, to change, or IMPLIED, WHICH EXTEND BEYOND THE to assume for it, any other warranty or liability DESCRIPTION ON THE FACE HEREOF. THERE IS concerning its products. NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A WARRANTY OF FITNESS In no event shall NAPCO be liable for an amount in FOR A PARTICULAR PURPOSE. ADDITIONALLY, excess of NAPCO s original selling price of the product, THIS WARRANTY IS IN LIEU OF ALL OTHER for any loss or damage, whether direct, indirect, OBLIGATIONS OR LIABILITIES ON THE PART OF incidental, consequential, or otherwise arising out of NAPCO. any failure of the product. Seller s warranty, was herein above set forth, shall not be enlarged, diminished or Any action for breach of warranty, including but not affected by and no obligation or liability shall arise or limited to any implied warranty of merchantability, must grow out of Seller s rendering of technical advice or be brought within the six months following the end of service in connection with Buyer s order of the goods the warranty period. furnished hereunder. IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT. In case of defect, contact the security professional who installed and maintains your security system. In order to exercise the warranty, the product must be returned NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY. Warning: Despite frequent testing, and due to, but not limited to, any or all of the following; criminal tampering, electrical or communications disruption, it is possible for the system to fail to perform as expected. NAPCO does not represent that the product/system may not be compromised or circumvented; or that the product or system will prevent any personal injury or property loss 5

by burglary, robbery, fire or otherwise; nor that the NAPCO is not an insurer of either the property or safety product or system will in all cases provide adequate of the user s family of employees, and limits its liability warning or protection. A properly installed and for any loss or damage including incidental or maintained alarm may only reduce risk of burglary, consequential damages to NAPCO s original selling robbery, fire or otherwise but it is not insurance or a price of the product regardless of the cause of such guarantee that these events will not occur. loss or damage. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY Some states do not allow limitations on how long an DAMAGE, OR OTHER LOSS BASED ON A CLAIM implied warranty lasts or do not allow the exclusions or THE PRODUCT FAILED TO GIVE WARNING. limitation of incidental or consequential damages, or Therefore, the installer should in turn advise the differentiate in their treatment of limitations of liability for consumer to take any and all precautions for his or her ordinary or gross negligence, so the above limitations safety including, but not limited to, fleeing the premises or exclusions may not apply to you. This warranty and calling police or fire department, in order to mitigate gives you specific legal rights and you may also have the other rights which vary from state to state. possibilities of harm and/or damage. Head Office: FIREWOLF Advanced Fire Products NAPCO Security Systems, Inc. 333 Bayview Avenue AMITYVILLE, N.Y. U.S.A. 11701 Phone: (516) 842-9400 IN NORTH AMERICA Phone: 1-800-645-9445 FAX Toll Free: (516) 789-9292 Web Page: http://www.napcosecurity.com e-mail: techinfo@napcosecurity.com 6