TYCO VALVES & CONTROL Dual Painting System

Similar documents
Control Panel User Guide

PROTECTING AGAINST ARC FLASH HAZARDS

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

Tri-Stack Smart System

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

NFPA 70E Edition Update

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Pump-Down Controller MODEL 4052

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

Service Manual Models: 1.0, 1.3, and 1.5

TC-150 CONVEYORIZED OVEN. OPERATION AND MAINTAINANCE MANUAL Ovens with Omron PLC and Touchscreen

MicroPulse Dryer Northpoint Parkway Acworth, GA

O PE R AT I ON HO851G REVOLVING TRAY OVEN. MODEL HO851G GAS ML Pan ML Pan ML Pan ML Pan

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Heller Industries A688951: Rev-D Jan-2007 Oven System Setup Wizard: Software version

Technical

Corn Flame Energy Corn Stove Model 3000

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

General The Dryer Programmer for Windows Computers

The Baked Food Company

Operating Display SCREENS

Inc Series Digital Gas Detector/Controller. Operation Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Covidien Articulating Absorba Tack Foil Pouch Leak Tester Owner s Manual IPE SN Rev 1

Oven Control System Operation - Ver 2.8

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Safety & Installation Instructions

Monitor Alarms and Events

Installation Instructions Model SSD-C-REM

Version Inc Series Digital Gas Detector/Controller. Operation Manual

Section 9 System Operation

Ammonia Leak Detector Manual

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Scroll Medical Air Compressor with Premium NFPA Control Panel

GLOBAL FINISHING SOLUTIONS

Programmable Thermostat

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

Supra-I.Q. Version 3.0.SP Diagnostic Cleaning System Installation and Operation Manual

Annunciation, Remote Monitoring, Control Industrial Control Panels

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

Fire Command Keypad. XR5 User s Guide

YCIV Hz & Hz

DRI-AIR INDUSTRIES, INC. HA750B B HOT AIR DRYER OPERATING MANUAL

DryLINK TRAINING Phoenix DryMAX XL and DryLINK

Safety & Installation Instructions

5.0 ALARMS & TROUBLESHOOTING

Section 8 System Operation

Control Panel User Guide (TO BE RETAINED BY THE USER)

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

INSTALLATION & OPERATION MANUAL

Pioneer-R16 Gas Monitor Operator s Manual

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

GeneSys Air-Cooled Screw Compressor Chiller

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

Operational Overview and Controls Guide

PowerCommand FT-10 Network LONWORKS System Annunciator

2012 Toolbar & NH3 Operators Manual

Pump-Up Controller MODEL 4062

1 and 2 Fan Vision Series Portable Dryers

SECTION ENCLOSED CONTROLLERS

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

ESSEX ENGINEERING CORPORATION

Soft Start Series MP700 Solid State, Reduced Voltage

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

C44A/C44AW DISHWASHER

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

INSTALLATION INSTRUCTIONS

Laptop / PC Programming Manual

SECTION AUTOMATIC TRANSFER SWITCHES

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

2000 Series. Program Entry Guide. Control Panels

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

Safety & Installation Instructions

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Important safety information

BB TM 508/509 ANTI TWO-BLOCK ALARM SYSTEM HYDRAULIC CRANE INSTALLATION. Greer Company Crane Systems. Greer Company

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Technical

Transcription:

TYCO VALVES & CONTROL Dual Painting System Thierica Equipment #12095-010 OPERATION/SEQUENCE OF EVENTS

INDEX START-UP... 3 LOAD / UNLOAD STATION OPERATIONS... 4 SHUT-DOWN... 5 PAGE DESCRIPTIONS... 6-25 MAIN SCREEN... 6 BOOTH(s)... 8 OVEN(s)... 11 CONVEYOR... 16 AMU... 18 VOC... 19 FAULT SCREEN... 21 START- UP SCREEN... 22 UTILITY... 25 TROUBLESHOOTING... 26-30 Page 2

START-UP 1. Clear working area from any obstructions. Turn on main air to the system. Turn on the Electrical Disconnect located on the Main Thierica Electrical Cabinet. Reset all Emergency Stops. (Thierica Electrical Cabinet, Paint Booths, Load Stations, Unload Stations) Press Control Power On located on the Main Enclosure. The button s green light should turn on. Reset any alarms. 2. Run the Auto Start-up Routine: From the touch screens, press From this screen, press. (Bottom center of the screen). (Top left of the screen) Under, all of the lights should be green and there should not be any red in this window. Under or, press. The system should automatically start the blowers, oven heater. The button will change to green. 3. Run the Auto Cycle: during this routine. To stop the START-UP ROUTINE CONTROL, press From the touch screens, press. (Bottom center of the screen) Under or, press. The respective line will be placed in Automatic. The button will change to green the system is in Automatic. To place the system in Manual, press. Note: any alarm will place the system in Manual. 4. The Paint System is now ready for production. when Page 3

LOAD STATION OPERATIONS The sequence of operations for the Load Station is as follows. After the operator has loaded the part, the Line Ready pushbutton may be pushed. Note: Each of the Line Ready pushbuttons (Load Station and Paint Booth) will need to be pushed before the conveyor will index. After the Index Count Down has finished, the conveyor will index. There is a dome light on the Main Panel. The color definitions are as follows. Red - Steady There is a fault with the system. Check the alarm pages at the touch screen. Green - Steady The system is in Automatic mode. Amber - Steady The system is in Manual mode. Page 4

SHUT-DOWN After the last part has been removed from the system, run the Auto shut-down routine: From the touch screen, press From this screen, press. (Bottom center of the screen).. (Top left of the screen) Under, press. The system should automatically stop the blowers, oven heater. The button will change to green during this routine. The oven exhaust and recirculation blowers will stop after the oven temperatures, and are below 150 deg F. To stop the SHUT-DOWN ROUTINE CONTROL, press. Page 5

PAGE DESCRIPTIONS MAIN SCREEN 1. The is displayed when the system is first turned on. This screen displays the layout of the system and shows the status of the dome lights. 2. The Local Message Display (at the top of the screen) will show the current condition that is preventing a required action. This display will pop-up on every screen. 3. Each area of the machine is accessed from this screen: BLUE & SILVER LINE PAINT BOOTH BLUE LINE PAINT BOOTH DUAL USE PRE-HEAT / SILVER CURE OVEN BLUE LINE PRIME OVEN BLUE LINE TOP COAT OVEN BLUE LINE CONVEYOR SILVER LINE CONVEYOR AIR MAKE-UP UNIT Page 6

VOC FAULT CONTROL (Engineering Use Only) 4. The red stop sign icons indicate an E-Stop has been pushed and needs to be reset (twist to release). 5. The yellow triangle icon indicates that the control power is off at the main panel. 6. The flashing yellow & orange icons over the screen pushbuttons indicate a fault condition in this area. (See FAULT SCREEN below) 7. The buttons located on the bottom toolbar are the same on every screen. The control for these buttons are as follows: Change to the MAIN SCREEN. Monitor system. Start System Start Up & Shut Down routines. Change to the FAULT SCREEN(s). View current & past alarms. Change to the START-UP SCREEN. Change to the UTILITY SCREEN. Perform a dome light test. Log into user accounts. View date and time clock. Silence the current alarm horn. Press this button to reset any system faults. The button will flash if there is an active system fault. If the fault is still active, it will not reset. Page 7

BOOTH >> BLOWERS 1. The are accessed from this screen. Note: this access is common to all Booth screens. 2. The and starts with the blowers control. 3. The start/stop control is by the buttons. 4. The flashing yellow & orange icons over the screen pushbuttons indicate a fault condition in this area. (See FAULT SCREEN below) Page 8

BOOTH >> GUNS 1. Under, three items are shown: The total VOC for the current hour. The total VOC for the current day. The total VOC for the current week. 2. The buttons are only visible when an Engineer is logged in. Note: each total can be individually reset and has a confirmation button. Page 9

BOOTH >> SENSORS 1. This screen shows the state of additional sensors in the booth, grey for off and green for on. The Line Ready pushbutton. The Emergency Stop pushbutton. The Gun At Flush limit switch. Page 10

OVEN >> BLOWERS 1. The are accessed from this screen. Note: this access is common to all Oven screens. 2. The, and starts with the blowers control. 3. The start/stop control is by the buttons. 4. The flashing yellow & orange icons over the screen pushbuttons indicate a fault condition in this area. (See FAULT SCREEN below) Page 11

OVEN >> HEAT CONTROL 1. The window contains the following: The will show the current oven temperature in degrees F. The window will be: Grey when the temperature is below the set point range. Green when it is within the range. Red when it is above range. The oven heat is started and stopped with the buttons. The will set the oven temperature in degrees F. The is set by: for manual control. This mode will set the output as a fixed percentage (see 1.4.c below). for automatic control. This mode will adjust the output as needed to hold the temperature set point (see 1.3 above). will show the current output to the heaters and allow the manual output to be set. The range is 0-100 percent. 2. The are used to: set the high limit of the system in degrees F. The range is 0-300 deg. F. Page 12

set the range in degrees F. This is a plus or minus tolerance to be added to and subtracted from the set point (see 1.3 above). The range is 0-50 deg. F. Page 13

OVEN >> TREND CHART 1. The window contains the following: to show the oven set point and a matching pen. to show the current oven temperature in degrees F. and a matching pen. The range is 0-300 degrees F. The time span is 10 hours (one hour between squares). Page 14

OVEN >> SENSORS 1. This screen shows the following: to indicate the temperature in the heater box, in degrees F. to indicate the temperature in the oven, in degrees F. Page 15

CONVEYOR >> DRIVE CONTROL 1. The are accessed from this screen. 2. The and starts with the drive control. 3. The start/stop control is by the buttons. This will start and stop an index of each conveyor. 4. The flashing yellow & orange icons over the screen pushbuttons indicate a fault condition in this area. (See FAULT SCREEN below) 5. Under there are buttons. These will jog the respective conveyor forward and backwards. There is a 5 second limit on each jog motion. 6. When the conveyor is in motion, there will be a flashing to indicate motion. Page 16

CONVEYOR >> SENSORS 1. This his screen shows the state of additional sensors in the booth, grey for off and green for on: The Conveyor Jam Limit Switch. The Conveyor Pulse Generator Prox. Switch. The Conveyor Tooling Photo Eye. The Conveyor (Chain) Take Up Limit Switch. The Line Ready pushbutton. 2. The oven door switch is also shown on this page. Page 17

AMU (Air Make-Up Unit) 1. The window contains the following for both AMU 1 and AMU 2: The start/stop of the units is with the buttons. will show the Outside Air Temp. in Deg. F. will show the Inside Air Temp. in Deg. F Page 18

VOC >> GUN SET-UP 1. NOTE: Access to this page is limited to ENG or above. 2. The are accessed from this screen 3. The, and windows contain the following for each gun in each booth: will show the percentage of VOC used in component A. The range can be entered from 0 to 100 % will show the percentage of VOC used in component B. The range can be entered from 0 to 100 % will show the Specific Gravity of the VOC used in component A. The range can be entered from 0 to 2. will show the Specific Gravity of the VOC used in component B. The range can be entered from 0 to 2. Page 19

VOC >> BOOTH LIMITS 1. NOTE: Access to this page is limited to ENG or above. 2. The and windows contain the following for each booth: will show the percentage of allowed VOC usage (each hour) in this booth to sound an alarm. The range can be entered from 0 to 100% 100% is six pounds of VOC. will show the percentage of allowed VOC usage (each hour) in this booth to sound an alarm AND shut off the gun. The range can be entered from 0 to 100% 100% is six pounds of VOC. will show the percentage of allowed VOC usage (each week) in this booth to sound an alarm. The range can be entered from 0 to 100% 100% is five hundred pounds of VOC. will show the percentage of allowed VOC usage (each week) in this booth to sound an alarm AND shut off the gun. The range can be entered from 0 to 100% 100% is five hundred pounds of VOC. Page 20

FAULT SCREEN 1. The are accessed from this screen. 2. There are two screens that make up the fault screen section. The first screen (shown above) is the screen. This screen is for viewing current faults with the system. The second screen is the screen (not shown). This screen is for viewing past faults on the system. Press the buttons in the upper left hand corner to switch between the screens. Fault messages are displayed with the most recent at the top of the list. See the fault code section for help in troubleshooting the fault messages. 3. Use the arrow keys on the right to scroll or page up and down the list. 4. See the TROUBLESHOOTING section, below. Page 21

START-UP SCREEN 1. The are accessed from this screen. 2. Under each area may be enabled or disabled as needed: will display a pop-up window to show the system power status. will display a pop-up window to show Booth 1 status and allow it to be enabled or disabled. Each of the other area pop-up windows will function in a similar manner. 3. The BLUE LINE ACTIVE or the SILVER LINE ACTIVE text will show when each line is active. Only one line may be active at a time (see Start-Up below). 4. Under the system can be placed in: automatic or manual. If all areas are ready (see above): Booth 1 Line Ready pushbutton must be pushed, unless disabled. Booth 2 Line Ready pushbutton must be pushed, unless disabled. The Load/Unload Line Ready pushbutton must be pushed. The Index Count Down must be at zero., unless disabled Page 22

5. Under each Line Ready pushbutton may be enabled or disabled as needed: will enable or disable (override) the Line Ready pushbutton in Booth 1. will enable or disable (override) the Line Ready pushbutton in Booth 2. will enable or disable (override) the Line Ready pushbutton at the Load/Unload Station. will show the time in minutes until the conveyor may index. Page 23

START-UP SCREEN >> START-UP 1. Under each area may be enabled or disabled as needed for automatic start-up: will display a pop-up window to show the system power status. will display a pop-up window to show Booth 1 status and allow it to be enabled or disabled. Each of the other area pop-up windows will function in a similar manner. NOTE: The silver line will only use Booth 1 and Oven 1. 2. Under the system can: start/stop the automatic start-up. If all areas are ready (see above) Page 24

UTILITY SCREEN 1. Under window, the dome light can be tested. During the test, each color of the dome light(s) will be on for two seconds. 2. Under window, the screen security will be allow. This is for future use. 3. Under window, the current date & time are displayed. Page 25

TROUBLESHOOTING WARNING: Access to the THIERICA electrical enclosure while energized must only be by a qualified person. This enclosure contains high voltages and a potential for electrical arc flash hazard. A qualified person according to NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces, Article 1-5.4.1: shall be trained and knowledgeable of the construction and operation of equipment or a specific work method, and be trained to recognize and avoid the electrical hazards that might be present with respect to that equipment or work method. Such persons shall also be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools and test equipment. One can be considered qualified with respect to certain equipment and methods, however, still be unqualified for others. Such persons permitted to work within limited approach of exposed energized conductors and circuit parts shall, at a minimum, be additionally trained in all of the following: (a) The skills and techniques necessary to distinguish exposed energized parts from other parts of electric equipment (b) The skills and techniques necessary to determine the nominal voltage of exposed energized parts (c) The approach distances specified in Table 2-1.3.4 of Part II and the corresponding voltages to which the qualified person will be exposed (d) The decision-making process necessary to determine the degree and extent of the hazard and the personal protective equipment and job planning necessary to perform the task safely Page 26

FAULT CAUSE REMEDY [000] Control Power Off Fault [001] Main Enclosure E-Stop Fault [002] Blue Load Station E-Stop Fault [003] Silver Load Station E-Stop Fault -The control power to the system has been turned off -Emergency Stop was pressed -Emergency Stop was pressed -Emergency Stop was pressed [004] Silver Booth E-Stop Fault -Emergency Stop was pressed -Reset all Emergency Stops -Press CONTROL POWER ON -Verify system power is on -Check Safety E-stop wiring -Reset the emergency stop -Verify emergency stop wiring -Reset the emergency stop -Verify emergency stop wiring -Reset the emergency stop -Verify emergency stop wiring -Reset the emergency stop -Verify emergency stop wiring [005] Blue Booth E-Stop Fault [012] Fire Protection Fault [014] AMU 1 Heartbeat Fault [015] AMU 2 Heartbeat Fault [100] Dual Oven Exhaust Start/Current Fault [101] Dual Oven Recirc Start/Current Fault [110] Dual Oven Htr. Box Over Temp. Fault [111] Dual Oven Chamber Over Temp. Fault [112] Dual Oven Htr. Box Hi Limit Fault [113] Dual Oven Chamber Hi Limit Fault [114] Dual Oven Not At SP Fault [115] Dual Oven Burner Off Fault [200] Blue Line Primer Oven Exhaust Start/Current Fault [201] Blue Line Primer Oven Recirc Start/Current Fault -Robot Controller Emergency Stop was pressed -Robot Teach Pendant Emergency Stop was pressed -The fire protection system has issued an alarm -Communication to the AMU has failed -Communication to the AMU has failed -The Motor Starter or Current Switch did not respond in the time allowed -The Motor Starter or Current Switch did not respond in the time allowed -The temperature in The Heater Box is above the set point limit -The temperature in The Oven is above the set point limit -The temperature in the Heater Box is above the high limit -The temperature in The Oven is above The high limit -The oven did not reach set point in the time allowed -The burner did not give an "ON" signal in the time allowed -The Motor Starter or Current Switch did not respond in the time allowed -The Motor Starter or Current Switch did not respond in the time allowed -Reset the emergency stop -Press "Fault Reset" -Check the fire protection system -Press "Fault Reset" -Check the wiring to the AMU -Power cycle the 702-RTA unit -Check the wiring to the AMU -Power cycle the 702-RTA unit -Check the Motor Starter setting -Check the motor belt for proper tension -Check the Motor Starter setting -Check the motor belt for proper tension -Check the thermocouple wiring -Check the thermocouple wiring -Check the thermocouple wiring -Check the thermocouple wiring -Adjust the oven set point -Place the Oven Output Control in automatic -Check the burner controller -Check the Motor Starter setting -Check the motor belt for proper tension -Check the Motor Starter setting -Check the motor belt for proper tension Page 27

[210] Blue Line Primer Oven Htr. Box Over Temp. Fault [211] Blue Line Primer Oven Chamber Over Temp. Fault [212] Blue Line Primer Oven Htr. Box Hi Limit Fault [213] Blue Line Primer Oven Chamber Hi Limit Fault [214] Blue Line Primer Oven Not At SP Fault [215] Blue Line Primer Oven Burner Off Fault [300] Blue Line Top Coat Oven Exhaust Start/Current Fault [301] Blue Line Top Coat Oven Recirc Start/Current Fault [310] Blue Line Top Coat Oven Htr. Box Over Temp. Fault [311] Blue Line Top Coat Oven Chamber Over Temp. Fault [312] Blue Line Top Coat Oven Htr. Box Hi Limit Fault [313] Blue Line Top Coat Oven Chamber Hi Limit Fault [314] Blue Line Top Coat Oven Not At SP Fault [315] Blue Line Top Coat Burner Off Fault [320] Blue Line Top Coat Oven Door Open Fault [400] Blue/Silver Line Booth Exhaust Start/Current Fault [410] Booth 1 VOC 6 Lbs Warning [411] Booth 1 VOC 6 Lbs Fault [412] Booth 1 VOC 500 Lbs Warning -The temperature in The Heater Box is above the set point limit -The temperature in The Oven is above the set point limit -The temperature in the Heater Box is above the high limit -The temperature in The Oven is above The high limit -The oven did not reach set point in the time allowed -The burner did not give an "ON" signal in the time allowed -The Motor Starter or Current Switch did not respond in the time allowed -The Motor Starter or Current Switch did not respond in the time allowed -The temperature in The Heater Box is above the set point limit -The temperature in The Oven is above the set point limit -The temperature in the Heater Box is above the high limit -The temperature in The Oven is above The high limit -The oven did not reach set point in the time allowed -The burner did not give an "ON" signal in the time allowed -The oven doors were open when the conveyor was in motion -The Motor Starter or Current Switch did not respond in the time allowed -The VOC warning limit for this hour has been reached -The VOC fault limit for this hour has been reached -The VOC warning limit for this week has been reached Page 28 -Check the thermocouple wiring -Check the thermocouple wiring -Check the thermocouple wiring -Check the thermocouple wiring -Adjust the oven set point -Place the Oven Output Control in automatic -Check the burner controller -Check the Motor Starter setting -Check the motor belt for proper tension -Check the Motor Starter setting -Check the motor belt for proper tension -Check the thermocouple wiring -Check the thermocouple wiring -Check the thermocouple wiring -Check the thermocouple wiring -Adjust the oven set point -Place the Oven Output Control in automatic -Check the burner controller -Close the oven doors -Press "Fault Reset" -Check the Motor Starter setting -Check the motor belt for proper tension -Wait for the next hour to -Adjust the Booth Limits (See Page 20) -Press "Fault Reset" -Wait for the next hour to -Adjust the Booth Limits (See Page 20) -Press "Fault Reset" -Wait for the next hour to -Adjust the Booth Limits (See Page 20) -Press "Fault Reset"

[413] Booth 1 VOC 500 Lbs Fault [500] Blue Line Booth Exhaust Start/Current Fault [510] Booth 2 VOC 6 Lbs Warning [511] Booth 2 VOC 6 Lbs Fault [512] Booth 2 VOC 500 Lbs Warning [513] Booth 2 VOC 500 Lbs Fault [600] Silver Line Conveyor Drive Fault [602] Silver Line Conveyor Jam Fault [603] Silver Line Conveyor Take Up Fault [604] Silver Line Conveyor Index Spacing Fault [700] Blue Line Conveyor Drive Fault -The VOC fault limit for this week has been reached -The Motor Starter or Current Switch did not respond in the time allowed -The VOC warning limit for this hour has been reached -The VOC fault limit for this hour has been reached -The VOC warning limit for this week has been reached -The VOC fault limit for this week has been reached -The AC Drive's ready signal is not on -The Conveyor Pulse Generator Prox. did not give a signal in the time allowed -The Chain Take-Up limit switch is activated -The distance between racks were not the same -The AC Drive's ready signal is not on -Wait for the next hour to -Adjust the Booth Limits (See Page 20) -Press "Fault Reset" -Check the Motor Starter setting -Check the motor belt for proper tension -Wait for the next hour to -Adjust the Booth Limits (See Page 20) -Press "Fault Reset" -Wait for the next hour to -Adjust the Booth Limits (See Page 20) -Press "Fault Reset" -Wait for the next hour to -Adjust the Booth Limits (See Page 20) -Press "Fault Reset" -Wait for the next hour to -Adjust the Booth Limits (See Page 20) -Press "Fault Reset" -Press "Fault Reset" -Verify power on the drive -Verify motor disconnect is on -Disconnect power from the drive for 30 seconds then turn back on -Refer to the drive manual for additional troubleshooting -Check for a jammed part -Check for a loose belt on the drive motor -Check the adjustment of the prox -Check the wiring on the switch -Check the position of the spring slide at the chain take up -Check the number of links between the racks near the Tooling PE -Press "Fault Reset" -Verify power on the drive -Verify motor disconnect is on -Disconnect power from the drive for 30 seconds then turn back on -Refer to the drive manual for additional troubleshooting Page 29

[702] Blue Line Conveyor Jam Fault [703] Blue Line Conveyor Take Up Fault [704] Blue Line Conveyor Index Spacing Fault -The Conveyor Pulse Generator Prox. did not give a signal in the time allowed -The Chain Take-Up limit switch is activated -The distance between racks were not the same -Check for a jammed part -Check for a loose belt on the drive motor -Check the adjustment of the prox -Check the wiring on the switch -Check the position of the spring slide at the chain take up -Check the number of links between the racks near the Tooling PE Page 30