Room thermostat with Auto Timer, Option External Input

Similar documents
Room thermostat with Auto Timer, Option External Input

Room thermostat with Auto Timer, Option External Input

Room thermostat with independent DHW control

Wireless room thermostat with LCD

Room thermostats with LCD RDD100..

Room thermostat with Auto Timer, independent DHW

Room thermostat with Auto Timer, Option External Input

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Semi flush-mount room thermostats

Flush-mounted room thermostats

Room thermostats with LCD for wall mounting

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Wall-mounted room thermostat with LCD

Flush-mounted room thermostat

Digital Room Thermostat for Heating Applications with 7-Day Time Program

Semi flush-mount room thermostat

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Use. For 2-pipe fan coils

Room thermostat with 24-hour time switch and large LCD

Preliminary Release. Room Temperature

Room Temperature Controllers

Semi flush-mount communicating room thermostats

Self-learning Room Temperature Controller

Application guide RDG160 Remote control

Room Temperature Controller

Self-learning Room Temperature Controller

Room Temperature Controller with LCD

RAB21 RAB21.1. For two-pipe fan coils

Touch Screen Flush-mount Room Thermostats with KNX Communications

Room Temperature Controller

Flush-mounted room temperature controllers for VAV / CAV applications, with LCD RDU340

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Smart Thermostat RDS110

Self-learning Room Temperature Controller

PRELIMINARY EDITION

REA22 Room Temperature Controller

Self-learning Room Temperature Controller

Electronic timeswitch

Room thermostats with LCD for wall mounting RDG100 RDG100T RDG110, RDG110U RDG160T, RDG160TU RDG100T/H

RAA30 RAA30.16/GR RAA30.26/GR. Room Thermostat. Adjustable room thermostat for heating only or cooling only systems

RVL481. Heating Controller. including d.h.w. heating

RVL480. Heating Controller

Self-learning Room Temperature Controller

QAW70. Room Unit. Building Technologies. for use with heating controllers

Room Temperature Sensor

Room Temperature Controller

ROOM THERMOSTATS KNX BASIC DOCUMENTATION

District Heating Controller

RVL479. Heating Controller. for use with a partner unit

Room thermostats with KNX communications RDG100KN, RDG160KN

Room thermostats with display, for fan coil units RDG100, RDG100T, RDG110, RDG140, RDG160

Room thermostat with display, for VAV RDG400

Room thermostats with LCD for wall mounting RDG100, RDG100T, RDG110, RDG140, RDG160, RDG100T/H

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

сайт: эл. почта: Use RAB11 RAB11.. For 2-pipe fan coils

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

Immersion Temperature Controller

Frost Protection Thermostat

Control solutions Biofloor

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Instruction FH-CWP Thermostat

Semi-flush mount communicating room thermostats RDF301, RDF , RDF600KN

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Saving energy while ensuring an enhanced room climate

Heating and D.h.w. Controller RVL482 Basic Documentation

Room thermostat with KNX communications RDG100KN

сайт: эл. почта: Use RAB21 RAB21.. For two-pipe fan coils

Room thermostat with KNX communications RDG400KN

District heating controller

Boiler Sequence Controller

Indoor Air Quality Controller

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

District heating controller

No. Icon Name Function

Frost Units for air temperature monitoring

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

GreenCon On/Off Room Thermostat

Model: Touch-RF. 1 Wireless Series

for relative humidity and temperature with calibration certificates

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Room thermostats with KNX communications RDG100KN, RDG160KN, RDG165KN

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

GreenCon On/Off Room Thermostat

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

RVL470. Heating Controller. Use. Functions. Series B

Room Temperature Sensors

Thermostats. Digital Programmable. GEAppliances.com

Room Unit. Building Technologies SYNERGYR

Transcription:

s 1 422 Room thermostat with Auto imer, Option External Input for heating systems RDE100.. Room temperature control 2-position control with On/Off output for heating Comfort, Economy, Auto timer and Protection mode Auto time switch Adjustable commissioning and control parameters Mains-powered AC 230 V (RDE100) or battery-powered DC 3 V (RDE100.1) Multifunction input (RDE100.1 only) for external floor sensor, keycard contact, etc. Use he RDE100.. is used to control the room temperature in heating systems. ypical applications: Apartments Commercial spaces Schools For the control of the following pieces of equipment: hermal valves or zone valves Gas or oil boilers Fans Pumps Floor Heating CB1N1422en_03 2015-01-14 Building echnologies

Functions Room temperature control via built-in sensor or external input Selection of operating mode with operating mode touchkey Setting auto time switch (individual day, 7 day or 5-2 day) Display of current room temperature or setpoint in C or F ouchkey lock (manually) Setpoint lock Periodic pump run Reloading factory settings for commissioning and control parameters One multifunctional input (RDE100.1 only) freely selectable for: Floor Heating temperature limitation function Operating mode switchover contact (keycard, window contact, etc.) emperature control he RDE100.. acquires the room temperature with its built-in sensor and maintains the setpoint by delivering control commands. he switching differential is 1 K. ON OFF Q14 W SD 1422D01 [ C] Room temperature SD Switching differential W Room temperature setpoint Q14 Output signal for heating Floor heating limitation function (RDE100.1 only) he factory setting for this function is Off (disabled) and must be set to "On" if floor heating is used. he external floor temperature sensor is connected to input X1, and acquires the floor temperature. If the floor temperature exceeds the parameterized temperature limit xx ºC (P14 = 1, P15 = 1, P16 = xx ºC), the heating valve is fully closed until the floor temperature returns to a level below the parameterized limit. ypical application is rooms (dry floor). If the application does not require floor heating temperature limitation but instead uses the external sensor as a source for both room temperature display and control, the parameters will have to be set as follows: P14 = 1, P15 = 0. A typical application is the bathroom (wet floor) where a constant floor temperature is required. It is not recommended to have only an internal built-in room sensor for floor heating since there is a potential risk of overheating. Operating mode switchover function his function allows keycard application, please refer to the section Operating notes, Economy mode. 2 / 12

Periodic pump run function Can only be used when circulating pump or valve is controlled! his function protects the pump or valve against seizing during longer off periods. Periodic pump run is activated for 3 minutes every 24 hours at 12:00. Parameter P12 = 0 (Default) P12 = 1 Pump status Pump run off Pump run on on 3 min. 24 h off 12:00 12:00 1422Z04 ype summary Product No. Stock No. Features RDE100 S55770-278 Mains-powered AC 230 V RDE100.1 S55770-279 Battery-powered DC 3 V Ordering When ordering, please indicate product No. / stock No. and description. Example: Product No. Stock No. Description RDE100 S55770-278 Room thermostat Valve actuators/external sensor must be ordered separately. 3 / 12

Equipment combinations Description Product No. Data Sheet Electromotoric actuator SFA21.. 4863 Electrothermal actuator (for radiator valves) Electrothermal actuator (for small valves 2.5 mm) SA23.. 4884 SP23.. 4884 Damper actuator GDB.. 4634 Damper actuator GSD.. 4603 Damper actuator GQD.. 4604 Rotary damper actuator GXD.. 4622 Cable temperature sensor QAH11.1 1840 Room temperature sensor QAA32.. 1747 Mechanical design he room thermostat consists 2 parts: Plastic housing which accommodates the electronics, the operating elements and the room temperature sensor Mounting plate with screw terminals he housing engages in the mounting plate and is secured with a screw. Operation and settings 1) Operating mode touchkey 2) Set 3) Ok 4) ouchkey for decreasing a value 5) ouchkey for increasing a value 4 / 12

Display 22 21 20 19 18 1 2 3 5 6 17 16 15 7 14 8 9 4 10 11 12 13 # Symbol Description # Symbol Description 1 2 Indicating that batteries need to be replaced (only with battery-powered version RDE100.1) Protection mode (protection mode symbol can be enabled via parameter settings) 12 Display of time 13 Morning: 12-hour format Afternoon: 12-hour format 3 Auto timer mode 14 Confirmation 4 View and set auto time switch 15 F Room temperature in degrees Fahrenheit 5 Comfort mode 16 ouchkey lock activated 6 Economy mode 17 C Room temperature in degrees Celsius 7 Escape 18 Display of room temperature, setpoint, etc. 8 External input enabled (RDE100.1 only) 19 Heating On 9 Permanent setpoint setting 20 Weekday 1 = Monday 7 = Sunday 10 Day and time setting 21 imer bar 11 Holiday mode setting 22 Current room temperature 5 / 12

Mounting and installation notes Do not mount the thermostat in niches or bookshelves, not behind curtains, not above or near heat sources, and not exposed to direct solar radiation. Mount about 1.5 m above the floor. Mounting Mount the thermostat in a clean and dry location without direct air flow from a heating/cooling equipment, and not exposed to drip or splash water Wiring See Mounting Instructions M1429 enclosed with the thermostat. Ensure that wiring, fusing and earthing comply with local regulations Correctly size the cables to the thermostat and the valve actuators Use only valve actuators rated for AC 24 230 V he AC 230 V mains supply line must have a circuit breaker with a rated current of no more than 10 A Disconnect from power supply before removing the unit from its mounting plate External Inputs X1, may carry mains potential. Sensor cables or window contact must carefully install before powering up the thermostat 6 / 12

Commissioning notes Commissioning Sensor calibration Setpoint lock ouchpad scanning rate Change of batteries (only with batterypowered version RDE100.1) After power is applied, the thermostat carries out a reset during which all LCD segments flash, indicating that the reset was made correctly. After the reset, the thermostat is ready for commissioning by qualified HVAC personnel. he control parameters of the thermostat can be set to ensure optimum performance of the entire system. Please refer to Operating Instructions CB1B1422, section "Do you want to change parameters?". If the temperature on the display does not agree with the room temperature effectively measured, the temperature sensor can be recalibrated. For that purpose, adjust parameter P04. We recommend reviewing the setpoint lock (for public areas) in parameters P06 and P08 and changing them as needed. Since the thermostat uses touch technology and to minimize battery power consumption, a parameter P21 (adjustable from 0.25 to 1.5 seconds) is implemented for the user to adjust. his function is only valid for the batterypowered version and the default value is 1 second. his means that when, for a certain time, the user does not touch the touchpad, the unit operates in power saving mode and the touchpad is running at a scanning rate of 1 second. (From the calculation assuming 4 operations per day on the thermostat, the estimated 1-second scanning rate results in a battery life of 1 year. If the user increases the scanning rate, the batteries life is extended.) If the battery symbol appears, the batteries are almost exhausted and should be replaced. Use alkaline batteries type AAA. Operating notes he RDE100.. provides Comfort, Economy, Auto timer and Protection mode. he difference between Comfort and Economy mode is only the room temperature setpoint. he changeover between Comfort, Economy and Protection mode is made either automatically by the auto time switch or by pressing touchkey mode. Comfort mode Economy mode When Comfort mode is activated, symbol appears on the display. he setpoint (20 ºC) can be readjusted by pressing touchkeys + and. When Economy mode is activated, symbol appears on the display. he setpoint (16 ºC) can be readjusted by pressing touchkeys + and. In RDE100.1, a window contact feature is that a user can connect a window contact to the input X1,. Depending on whether the window contact is configured to Normally Open or Normally Close (Parameter P14 = 2, Parameter P17 = 0 or 1), a change in this status will automatically switch the thermostat from any modes to Economy mode. his feature is good for public area. he factory setting for this function is Off (disabled). 7 / 12

Protection mode ime switch If the temperature falls below 5 ºC, the unit automatically activates the heating output. he symbol appears only, if the icon is enabled via parameter settings. When Auto timer mode is enabled, the changeover between the operating modes (Comfort and Economy mode) will take place automatically. here are three options for time switch setting: individual day, 7 day or 5-2 day. You can select Comfort or Economy mode in every 15 minutes interval of the day. he 0:00 to 24:00 hour time bar will allow you to set the mode throughout the selected day(s). Default value Day/s Comfort mode Economy mode Mo (1) Fr (5) 6:00 8:00 hr 17:00 22:00 hr 22:00 6:00 hr 8:00 17:00 hr Sa (6) Su (7) 7:00 22:00 hr 22:00 7:00 hr Please refer to Operating Instructions CB1B1422, section "Do you want to enter your own time switch?" Holiday mode When holiday mode is activated, symbol appears on the display. he setpoint (12 ºC) and the number of days a user is away can be readjusted by pressing touchkeys + and. Maintenance notes he thermostats are maintenance-free. Disposal he devices are considered electronics devices for disposal in term of European Directive 2012/19/EU and may not be disposed of as domestic waste. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Dispose of empty batteries at designated collection points. echnical data Power supply Operating voltage RDE100 at L - N Frequency Power consumption AC 230 V +10/-15% 50 Hz 4 VA RDE100.1 DC 3 V (2 x 1.5 V alkaline batteries AAA) For battery life (RDE100.1), see below (alkaline batteries type AAA). Battery life calculation is based on the touchpad scanning rate during idle time (assuming a user presses 4 touchkeys per day): Scanning rate 0.25 s Scanning rate 0.50 s Scanning rate 1.00 s Scanning rate 1.50 s 194 days battery life 274 days battery life 346 days battery life 379 days battery life 8 / 12

Control inputs External sensor (RDE100.1 only) Control outputs Function data Environmental conditions Norms and standards Control input Q11-Nx (Com) Rating RDE100 Rating RDE100.1 External sensor X1 - (Reference) Or Digital On/Off X1 - (Reference) Control output Q12-Nx (NC contact) Rating RDE100 Rating RDE100.1 Control output Q14-Nx (NO contact) Rating RDE100 Rating RDE100.1 (AC 24 230 V) Max. 5(2) A Min. 8 ma (AC 24...230 V) Max. 5(2) A Min. 8 ma NC3K/QAH11.1/QAA32 On/Off switch (AC 24...230 V) Max. 5(2) A Min. 8 ma (AC 24...230 V) Max. 5(2) A Min. 8 ma (AC 24...230 V) Max. 5(2) A Min. 8 ma (AC 24...230 V) Max. 5(2) A Min. 8 ma External protection for incoming cable Circuit breaker Max. 10 A Circuit breaker tripping characteristic ype B, C or D to EN 60898 and EN 60947 Switching differential SD 1 K Comfort mode 20 C (5...35 C) Economy mode 16 C (5...35 C) Holiday mode 12 C (5...35 C) (Standalone) Built-in room temperature sensor Setpoint setting range Accuracy at 25 C emperature calibration range Resolution of settings and displays Setpoints emperature value displays Operation Climatic conditions emperature Humidity ransport Climatic conditions emperature Humidity Mechanical conditions Storage Climatic conditions emperature Humidity 5 35 C (Comfort/Economy mode) < ±0.5 K ±3.0 K 0.5 C 0.5 C As per IEC 60721-3-3 Class 3K5 0 50 C <95% r.h. As per IEC 60721-3-2 Class 2K3-25 60 C <95% r.h. Class 2M2 As per IEC 60721-3-1 Class 1K3-25 60 C <95% r.h. EU Conformity (CE) CE11420xx *) C-ick conformity to EMC emission standard AS/NZS 4251.1:1999 Safety class II as per EN 60730-1, EN 60730-2-9 Pollution class II as per EN 60730-1 Degree of protection of housing IP30 as per EN 60529 9 / 12

Environmental compatibility General he product environmental declaration CE1E1420xx contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Connection terminals for Solid wires or prepared stranded wires 2 x 1.5 mm 2 or 1 x 2.5 mm 2 (Min. 0.5 mm 2 ) Weight 0.166 kg Color of housing front RAL9003 *) he documents can be downloaded from http://siemens.com/bt/download. Connection diagrams L Lx 10A Lx S1 B1 X1 Q12 Q11 Q14 N1 3V Q12 Q11 Q14 X1 N1 N Y1 Nx 5(2) A Max. 1422A01 Nx Y1 5(2) A Max. 1422A02 RDE100 N1 Room thermostat Y1 Valve actuator L Live, AC 230 V N Neutral conductor, AC 230 V RDE100.1 Lx Live, AC 24... 230 V Q11, Q12 NC contact (for NO valves) Q11, Q14 NO contact (for NC valves) Nx Neutral conductor, AC 24...230 V X1 External input signal Measuring neutral for external input B1 emperature sensor (Floor temperature limit) S1 Switch (keycard, window contact) 10 / 12

Appication examples N1 F1 F2 N1 F2 F1 Y2 M1 1422S01 Y2 M1 1422S02 Room thermostat with direct control of a gas-fired wall-hung boiler Room thermostat with direct control of a gas-fired floor-standing boiler N1 N1 Y1 Y1 F M1 M1 1422S03 1422S04 Room thermostat with direct control of a heating circuit pump (precontrol by manual mixing valve) F1 hermal reset limit thermostat F2 Safety limit thermostat M1 Circulating pump Room thermostat with direct control of hydronic floor heating system N1 RDE100.. room thermostat Y1 Mixing 3-port valve with manual adjustment Y2 Magnetic valve Remarks Heating: Because of the unavoidable self heating effects of the electrical current, any loads of more than 3 Amperes connected to the unit can influence the control behavior and temperature accuracy in a negative way. 11 / 12

Dimensions All dimensions in mm 85 21.5 0.5 Ø80 127 83.5 Ø60 4.1 7.1 1422M01 12 / 12 ã Siemens Switzerland Ltd, 2013 Subject to change