Operating instructions Oil condensing boiler

Similar documents
Operating instructions

VIESMANN. Operating instructions VITODENS 100-W. for the system user

Operating instructions

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Operating Instructions

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

/2010 US/CA

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

ir-range 8G /03.15 Changes reserved.

Operating instructions

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Operating instructions

Operating instructions

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Operating instructions

WHE 2.24 / WHE 2.24 FF

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

GB24 & GB30. User Manual

User's Instructions. Alpha CB50

WOLF GAS CONDENSING BOILERS COMFORTLINE

BM Programming Module. For the heating engineer Installation instructions

Operating instructions

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

The iqe Boiler Range. Combination and System T Boilers.

User manual. Logano GC 124 II. Gas boiler

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

Operating instructions

Installation and maintenance instructions

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

USERS MANUAL FOR GAS BOILERS

USER GUIDE LOGIC HEAT H

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Logic+ Combi

TO DO IF YOU SMELL GAS

User s Information Manual

Combi Eco Elite Range. User s Guide and Important Warranty Information

BWL air heat pumps BWS brine heat pumps

User s Information Manual

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

E-COMBI EVO E-SYSTEM EVO

Greenstar 12i/24i System

VIESMANN. Operating instructions VITOTRONIC 200. for the system user

Greenstar 24i junior / 28i junior

Baxi Maxflow Combi WM

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

Baxi Maxflow Combi FS

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Operating Instructions

prestige Control Application Supplement - Type 5 MCBA WARNING

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

DOMESTIC HOT WATER Follow operational sequence

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

Greenstar 12i system / 24i system

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user

BOILERMATE A CLASS OV

prestige Control Application Supplement WARNING

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

User s Information Manual

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

ecotec plus boiler user guide

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

24CDi, 28CDi & 35CDi II COMBI

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

USER S INFORMATION MANUAL

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

The guarantee on this appliance is valid for 12 months from the first day of installation.

Installation and maintenance instructions

BOILERMATE 2000 USER-GUIDE SWITCH. TEL: Gas Council Approved Reference Numbers

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

User s Information Manual Models: 45, ,000 Btu/hr

BOILERMATE A CLASS SP

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

prestige Control Application Supplement - Type 5 MCBA WARNING

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Gas Instantaneous Water Heater

For the owner. Operating manual. ecotec. Gas wall boilers with condensing appliance technology VU 466/4 VU 656/4

User s Information Manual

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Operating Instructions and User s Information Manual for use by engineers and heating contractors VITOTRONIC 100 IMPORTANT

Transcription:

Operating instructions Oil condensing boiler COB COB-CS Boiler for heating Boiler with stratification cylinder Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49-8751/74-0 Fax +49-8751/741600 Internet: www.wolf-heiztechnik.de Art.-Nr.: 30 62 548 Subject to technical modifications 04/09 GB

Index Index... Page Safety instructions... 3 Installation information / Maintenance information... 4 Hydraulic connections... 5 Control unit operation... 6 Information for energy-efficient operation... 7-8 Faults / Fault codes... 8 General notes Your oil condensing boiler is a high-quality product which incorporates the latest safety technology. These safety instructions should protect you from potential risks. 2 3062548_0409

Safety instructions SAFETY INSTRUCTIONS If you smell flue gas - Shut the system down - Open windows and doors - Notify your local contractor Caution - risk of poisoning! When changing a fuse - Isolate the boiler from the power supply before changing a fuse. The mains terminals of the boiler are 'live' even when the ON/OFF switch has been switched OFF. Caution - risk of electrocution! Frost protection The oil condensing boiler will be automatically protected against frost as long as it is switched on. The use of anti-freeze is not permissible. Completely drain the boiler if necessary. Caution - risk of water damage and faulty function through freezing. Balanced flue routing With low outside temperatures, the water vapour contained in the flue gas may condense and freeze on the balanced flue. This ice may fall from the roof causing injury or material losses. Prevent ice from falling by taking on-site measures, e.g. the installation of a snow guard. Caution - risk of injury. 3062548_0409 3

Installation information / Maintenance information Positioning/modifications - Your oil condensing boiler should only be installed and modified by an approved heating contractor, as only they have the essential knowledge to carry out such work. - Flue gas components must not be modified. - Never close or restrict the ventilation apertures in doors or walls when operating the boiler in the open flue mode; only start the boiler when the flue has been fully installed. - Only operate the boiler in balanced flue mode, after the balanced flue system has been fully installed and the wind protector is not covered up. - Oil condensing boilers may only be installed in rooms which are protected from frost. - Never isolate the oil condensing boiler from the power supply when outside temperatures fall below freezing, otherwise there is a risk of the system freezing up. - Do not modify the drain or the safety valve. Caution - ignoring this rule may lead to a risk of fire as well as a risk of destruction, poisoning or explosion! Do not use or store explosive and flammable materials, e.g. petrol, thinners, paints, paper etc. inside the boiler room! Corrosion protection Do not use (for cleaning, polishing etc.) or store sprays, solvents, chlorinated cleaning agents, paints, lacquer, adhesives, salts etc. on or in the vicinity of the oil condensing boiler. Under unfavourable conditions, these materials may lead to corrosion in the boiler and the flue gas system. Ducted vents routed through a roof may also contain corrosive vapours. Care Clean the casing with a damp cloth and a mild cleaning agent (must not contain chlorine). Then dry immediately afterwards. The boiler components may only be cleaned by a heating contractor. Maintenance NB - only the heating contractor offers the required knowledge and expertise! - According to the regional regulations, the user is obliged to arrange regular maintenance of the system in order to ensure the reliable and safe function of the oil condensing boiler. - Your boiler should be serviced annually. - Maintenance is explicitly detailed in the installation and maintenance instructions. - Isolate the boiler power supply before any maintenance work is carried out. - After a service and before the oil condensing boiler is restarted, check that all components that were removed for maintenance have been properly refitted. - We recommend you arrange a maintenance contract with an approved heating contractor. 4 3062548_0409

Hydraulic connections Please note before commissioning Filling the system The heating system must be completely filled with water. If necessary top up with water. When filling the heating system, the shut-off valves must be open. The system pressure must be 1.5 to 2.5 bar. The connection required for filling between the tap water and heating water must be removed after the fill has been completed. Otherwise there is a risk that your tap water will be contaminated by heating water. NB Inhibitors are not permissible. Otherwise there is a risk of damage to the boiler. Filling the siphon The siphon must be fitted and filled. Otherwise there is a risk of flue gas escaping. Opening the shut-off valves The shut-off valves for heating flow and return must be open. Checking the water level Regularly check the water level. The pressure gauge must indicate between 1.5 and 2.5 bar. Your heating contractor will explain how to top up your system. Do not supplement your heating water with additives, otherwise components may be damaged. 3062548_0409 5

Control unit operation Control unit operation ON/OFF switch Reset button DHW temperature selector Thermometer Illuminated signal ring Illuminated signal ring as status indicator Heating water temperature selector Illuminated signal ring Flashing green Constant green light Flashing yellow Constant yellow light Flashing red Explanation Standby (power supply ON, burner OFF, e.g. summer mode) Winter mode: Pump running, burner OFF Emissions test mode Burner operating, flame ON Fault Summer mode (heating OFF) Winter mode position 2 to 8 Emissions test mode (illuminated ring flashing yellow) DHW temperature selector, boiler 1 (15 C)... 9 (65 C) Heating water temperature selector 2 (20 C)... 8 (75 C) Note: The BM programming module can also be integrated into the boiler control unit. That means that all adjustments are made at the boiler control unit. For installation and operation, see installation instructions and BM programming module operating instructions. 6 3062548_0409

Information for energy-efficient operation Heating mode Saving energy with modern heating technology: oil condensing technology saves your cash Modern condensing technology utilises that energy for heating, which in conventional heating systems is expelled unused to the atmosphere with the flue gas. Use as little electrical energy as possible Operate your system with multi-stage heating pumps at the lowest possible level. Modulating pumps generally do not require adjustments, since they are automatically matched to the prevailing demand. Regular heating system maintenance pays for itself A contaminated burner or poorly adjusted boiler can reduce the heating system efficiency. Regular heating system maintenance through your local contractor quickly pays for itself. Heating at the lowest energy level Operate your heating system, where possible, with a return temperature of less than 45 C, to achieve the highest possible utilisation of condensing technology. A heating system control unit also regulates your heating costs A heating system in standby mode saves energy. A modern, weather-compensated or room temperature dependent heating system control unit ensures - with automatic night setback and thermostatic valves - that the system only operates when heat is required, saving money for the rest of the time. - Equip your heating system with a weather-compensated heating controller from the Wolf range of accessories. Your heating contractor will be happy to advise you about optimum adjustments. - In conjunction with the Wolf control unit accessory, use the night setback function to match the energy level to the actual demand period. - Use the optional summer mode adjustment. Never overheat your home Adjust the room temperature as accurately as possible. This leaves occupants comfortable and energy is not wasted on providing heating output that nobody needs. Differentiate between the optimum temperature for different rooms, such as living rooms and bedrooms. A room temperature which is one degree higher than necessary represents an additional energy consumption of approx. 6%. - Use room thermostats to match the room temperature to the actual use of the room. - In any room where you have installed a room temperature sensor, open the thermostatic valve fully. This enables you to achieve optimum control characteristics for your heating system. Ensure adequate air circulation Air must be able to circulate freely near the radiators and the room temperature sensors, otherwise the heating system will lose effectiveness. Badly positioned long curtains or furniture "swallow" up to 20% of energy. 3062548_0409 7

Information for energy-efficient operation Keep the heat inside the room - at night too At night, closing shutters and drawing curtains noticeably reduces heat losses via the window areas. Insulating the radiator recesses and light coloured paintwork can save up to 4% off your heating bills. Airtight joints at windows and doors also help to keep energy inside the room. Minimise energy loss through sensible ventilation Ventilating for hours loses heat stored in walls and objects. As a result, the room climate will only become comfortable again after prolonged heating. Short and thorough airing is more effective and pleasant. Venting the radiators Regularly vent the radiators in every room. This safeguards the perfect function of radiators and thermostats, particularly in the upper apartments of apartment blocks. The radiator responds quickly to changing heat demands. Intelligent use of DHW circulation pumps Always control DHW circulation pumps via time switches. Program these in accordance with your DHW demand patterns. DHW mode The optimum DHW temperature Only ever set the DHW temperature or that of the cylinder to the temperature you really require. Any additional heating uses additional energy. Sensible handling of DHW Showering consumes only approx. 1/3 of the water volume required for a bath. Repair any dripping taps immediately. Faults / Fault codes If the illuminated ring of the status indicator flashes red, where possible read the fault code on the connected control unit accessory and note the code. The boiler can be restarted by pressing the reset button. In case of repeated faults, switch OFF the boiler and notify your heating contractor. Oil condensing boilers are equipped with an electronic flue gas temperature limiter. The system automatically shuts down when the flue gas temperature exceeds 110 C. The boiler can be restarted by pressing the reset button. If this recurs, ask your heating contractor to check the flue gas system. Caution - risk of damage, poisoning and suffocation! Keep your operating instructions safe in an easily accessible place near your oil condensing boiler. The Velcro strip enables you to fit the clear wallet in a suitable position, for example on the side of the boiler. 8 3062548_0409