VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

Similar documents
VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

VIESMANN. Installation instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CM3 Gas condensing boiler with MatriX radiant burner

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

The oil condensing heating system efficient, futureproof technology with 98 percent efficiency

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P. Pellet boiler 4to48kW. Vitotec folder, register 12. File in: Type VL3B

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions. Extension AM1. Safety instructions. for contractors. Part no

The oil condensing heating system efficient, futureproof technology with 98 percent efficiency

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

for contractors Vitoplex 200 Type SX2A For applicability, see the last page Please keep safe.

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VITOPLEX. Low temperature oil and gas fired boilers Rated output Vitoplex 100: 575 to 1750 kw Vitoplex 200: 90 to 560 kw Vitoplex 300: 80 to 1750 kw

Pellet Boiler VITOLIGNO 300-P. Test winner Good (2.1) Pellet boiler VITOLIGNO 300-P. In the test: 10 systems 1 winner

VIESMANN. Service instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CR3 and CR37, 787 and 978 kw Gas condensing boiler

Oil/gas boilers and low pressure hot water boilers up to 22 MW

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

VIESMANN. Gas condensing boilers 87 to 1400 kw. Technical guide. VITOCROSSAL 200 Type CM2. VITOCROSSAL 300 Type CM3. VITOCROSSAL 300 Type CT3U

Natural Heat VITOCAL 300-A VITOCAL 350-A. Air source heat pumps

VIESMANN. Service instructions. MatriX radiant burner. for contractors

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Vitocrossal 300, CU3A - Introduction

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Vitodens 100-W. 10 Year Warranty on all stainless steel heat exchangers for gas condensing boilers up to 150 kw

INSTALLATION AND OPERATION MANUAL

Domestic Gas Boiler Guide

Domestic Gas Boiler Guide

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

WOLF GAS CONDENSING BOILERS COMFORTLINE

VIESMANN. Operating and service instructions VITOMAX 200-HW. for contractors

Condensing Technology. Condensing technology for improved economy and lower emissions

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

Copper-Fin GAS-FIRED WATER HEATERS

1 VICTRIX ZEUS Superior kw I features

Domestic Gas Boiler Guide

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

Technical Data Manual Model Nos. and pricing: see Price List

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

SPECIFICATIONS - NIKE

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

VIESMANN VITOVALOR 300-P Micro CHP unit based on a fuel cell with integral gas condensing boiler 750 W el, 1.0 to 25.2 kw th

Gas condensing technology

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

VIESMANN. Installation and service instructions. EHE immersion heater. for contractors. EHE immersion heater

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

Eco Angus Wood Pellet Boilers

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Domestic Product Guide

Technical guide VITOMAX 200 HS. Notes on design and operation. Vitotec technical guide folder, register 1. File in:

4FLOOR-STANDING GAS CONDENSING BOILERS

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

Domestic Product Guide

C Tahiti. condensing

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Condensing technology

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Installation and service instructions for contractors Logano plus SB625. Burner shroud not available in UK and Ireland

Installation and maintenance instructions

Transcription:

VIESMANN VITOLADENS 00-T Oil Unit condensing boiler 5.4 to 5.7 kw Datasheet Part no. and prices: see pricelist VITOLADENS 00-T Type VWB Ultra-low temperature oil boiler with condensing heat exchanger With Vitoflame 00 blue flame oil burner (5.4 to 5.7 kw). For open and balanced flue operation and for operation with fuel oil DIN 5160-1 EL Standard, low sulphur fuel oil DIN 5160-1 EL and fuel oil DIN 5160-6 EL A Bio 10: Suitable for low sulphur fuel oil EL with up to 10 % bio-components (FAME). 5/201

Vitoladens 00-T, type VWB The Vitoladens 00-T is the world's most widely sold oil condensing boiler, and comes at a particularly attractive price. In the output range 5.4 to 5.7 kw the Vitoladens 00-T offers an ideal opportunity for incorporating oil condensing technology in modernisation projects. The use of high quality materials and proven components ensures that the Vitoladens 00-T is very economical and reliable. The Vitoflame 00 Unit blue flame burner stands for particularly clean, environmentally responsible and efficient combustion. The two-stage heat recovery of the Vitoladens 00-T comprises the proven biferral composite heating surface and the corrosion-resistant stainless steel Inox-Radial heat exchanger, installed downstream of the boiler. This principle ensures that combustion and condensation occur in physically separate locations, so the combustion gases condense in an area that is free from deposits. In practice, this means longer-than-average service intervals for combustion chamber cleaning and significantly lower maintenance costs. A Highly effective thermal insulation B Inox-Radial heat exchanger C Integral silencer D Biferral cast iron and steel composite heating surface E Vitotronic control unit F Vitoflame 00 Unit oil burner Standard seasonal efficiency [to DIN]: up to 97 % (H s ) [gross cv] / 10 % (H i ) [net cv] Most widely sold oil condensing boiler worldwide Durable stainless steel biferral composite heating surface, proven in millions of boilers Corrosion-resistant stainless steel Inox-Radial heat exchanger Easy access to the heat exchanger surfaces for cleaning Quiet operation thanks to integral silencer Flexible siting with choice of open or balanced flue operation Easy-to-operate Vitotronic control unit with plain text and graphic display All commercially available EL-type fuel oils can be used. Also for fuel oil DIN 5160-6 EL A Bio 10: Low sulphur fuel oil EL with up to 10 % bio-components (FAME) 2 VIESMANN VITOLADENS 00-T

Specification Rated heating output T F /T R = 50/0 C kw 5.4 42.8 5.7 T F /T R = 80/60 C kw.0 40.0 50.0 Product ID CE-005BO107 Boiler body dimensions Length g mm 768 817 817 Width d mm 565 674 674 Height k mm 708 819 819 Overall dimensions Total length h incl. flue gas heat exchanger mm 1585 1770 1770 Total width e mm 667 776 776 Total height b (when operational) mm 815 940 940 Height a (control unit in operating position) mm 94 1050 1050 Height f (control unit in maintenance position) mm 116 1275 1275 Plinth height *1 mm 250 250 250 Height s (DHW cylinder below the boiler) Capacity 10 to 200 l mm 654 654 654 Capacity 50 l mm 786 786 786 Weight, boiler body kg 185 260 260 Total weight kg 242 Boiler with thermal insulation, heat exchanger, burner and boiler control unit Power consumption *2-100 % of rated heating output W 250 40 40-0 % of rated heating output W 84 11 11 Appliance in standby mode W Boiler water content (Boiler and heat exchanger) l 9 147 147 Permiss. operating pressure bar MPa Boiler connections Boiler flow and return G 1½ 1½ 1½ Safety connection (safety valve) G 1½ 1½ 1½ Drain R ¾ ¾ ¾ Filling R ½ ½ ½ Condensate drain/connection Ø mm 20 20 20 Flue gas parameters Temperature At 0 C return temperature C 9 8 9 At 60 C return temperature C 67 62 6 Mass flow rate for fuel oil EL kg/h 56 68 85 Standard seasonal efficiency [to DIN] At heating system temp. 50/0 C % 97 (H s ) [gross cv] / 10 (H i ) [net cv] Flue gas connection Ø mm 80 100 100 Ventilation air connection Ø mm 80 100 100 Available draught Pa 100 100 100 mbar 1.0 1.0 1.0 Sound power level (To EN ISO 9614-2) In balanced flue operation db(a) 60 60 60 In open flue operation db(a) 6 6 6 0. 0. 0. *1 When operating the boiler with a neutralising system and without a cylinder below the boiler, order the plinth separately. *2 Standard parameter. VITOLADENS 00-T VIESMANN

f i k Specification (cont.) KTS SA KV 120 AGA KR l m BH c b a A d e 55 9 g KOA h 19 E RLU 250 n A Plinth AGA Flue outlet E Drain and diaphragm expansion vessel connection BH Fill valve KOA Condensate drain KR Boiler return KTS KV RLU SA Boiler water temperature sensor Boiler flow Ventilation air connection for balanced flue operation. The heat exchanger can be installed so that the left or right connectors can be used for the boiler return and boiler flow. Safety connection (safety valve) l m KV/KR RLU p q r o s B B Vitocell 100-H or Vitocell 00-H (for specification see chapter "DHW cylinders") KR Boiler return KV Boiler flow RLU Ventilation air connection for balanced flue operation. The heat exchanger can be installed so that the left or right connectors can be used for the boiler return and boiler flow. 4 VIESMANN VITOLADENS 00-T

Specification (cont.) Dimensions Rated heating output (T F /T R =50/0 C) kw 5.4 42.8 5.7 a mm 94 1050 1050 b mm 815 940 940 c mm 76 874 908 d mm 565 674 674 e mm 667 776 776 f mm 116 1275 1275 g mm 768 817 817 h mm 1585 1770 1770 i mm 642 672 672 k mm 708 819 819 l mm 280 254 254 m mm 55 0 0 n mm 575 702 702 With DHW cylinder below the litre 160 and 200 50 200 50 50 boiler o mm 1229 161 156 1488 1488 p mm 1469 1601 1594 1726 1726 q mm 1417 1549 1528 1660 1660 r mm 1269 1400 1269 1400 1400 s mm 654 786 654 786 786 Pressure drop on the heating water side 00 0 The Vitoladens 00-T is only suitable for fully pumped hot water heating systems. 200 20 100 80 10 8 50 40 0 5 4 Pressure drop mbar 20 10 kpa 2 1 0.5 1 2 Flow rate in m³/h VITOLADENS 00-T VIESMANN 5

Specification (cont.) Minimum clearances c Rated heating output (T F /T R =50/0 C) kw 5.4 42.8 5.7 a mm 750 850 850 b mm 100 100 100 c mm 00 00 00 d mm 450 450 450 a b d Dim. a: Maintain this space in front of the boiler to enable the removal of the combustion chamber with silencer. Dim. c: Without DHW cylinder below the boiler. Dim. d: With DHW cylinder below the boiler (50 litre capacity). A Combustion chamber B Boiler C DHW cylinder D DHW cylinder sensor well (only for 50 litre capacity) Subject to technical modifications. Viessmann Werke GmbH&Co KG D-5107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 0, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com 6 VIESMANN VITOLADENS 00-T