74xx K. St. sample actual insp.w/photos, Edina, MN 5543x

Similar documents
Montgomery County Land Bank PRE SALE INSPECTION REPORT

Extra Mile Inspection, Inc.

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Inspection Report 123 My Street Midland, GA


Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Canadian Property Inspections

SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

OFFICE USE ONL Y BELOW

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. What is condensation?

CMHC HOME MAINTENANCE CHECKLIST

Home Inspection Report

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Canadian Property Inspections

Inside Out Home Inspections

Home Maintenance Schedule

El 0. El 0. El El. El El. El 0 TWO FAMILY HOUSING INSPECTINO CHECKLIST

MHI Services Inc. Property Inspection Report

1735 North Madison Avenue Pasadena CA 91104

Tennessee Valley Property Inspections

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

Axiom Property Inspections

1. Exterior/ Site $300 $500

Welcome! Today s topic: Weatherization and Seasonal Maintenance

Home Inspection Report

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

Doyle Home Inspections

Excellent Home Inspection Services, LLC

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

Closing Checklist. Mstr Hall/Clo. Mstr Bath. Guest Bath 1/2 Bath Kitchen Nook. Guest Hall. Utility Rm Garage Yard. Right Side Left Side Rear

Bayshore House Inspections LLC

RW West Consultants. Property Inspection Report

Inspection Summary. Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (480)

Advanced Property Inspections

fieldwork report contains the Functional

Cascade Inspection Services, LLC

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

Code Compliance Report

Energy-saving tips. For apartments and condos. pse.com/multifamilyretrofit. Bellevue, WA Puget Sound Energy. P.O. Box /17

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

20/20 Home Inspections. Photo Attachments

FAIRA TRANSPARENCY REPORTS. November 21, 2016

The Ultimate Home Maintenance Schedule

FAIRA TRANSPARENCY REPORTS NE 116th Pl, Kirkland, WA April 20 th, 2017

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

Property Condition Report

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

Final Phase Inspection

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Home Inspection Report

SUMMER. Over the summer, there are a number of indoor. Inspecting your home on a regular basis and. Seasonal Maintenance Schedule. For A Healthy Home

Summary. Structure Tech Home Inspections Raleigh Avenue South Saint Louis Park, MN Customer New Buyer

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

A GUIDE TO THE ROCK ISLAND HOUSING CODE. Prepared By: The City of Rock Island Inspection Division

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

WHY IS BUILDING SCIENCE IMPORTANT?

FAIRA TRANSPARENCY REPORTS nd Ave SE, Renton, WA March 21, 2018

All Waters Edge homes come with the following standard features throughout:

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Home Inspection Report

Spray Polyurethane Foam and Open-Combustion Appliances

Jeff Brown Inspections

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa

Tips on Saving Energy & Money at Home

Inspection Report. Mr. John Sample. Property Address: 123 Pine Street Vancouver BC V3M6C5. Exterior Front of Home. Fairbairn Inspection Services

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

Sample Report Site Visits Any Capitol, Any State Date

New Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011

Watson Home Inspection Services, LLC.

Residential Construction and Remodeling Estimates. compliments of. pillartopost.com

AGING IN PLACE CHECKLIST Use this checklist to identify fall hazards and accessibility for the homeowner and family members.

FAIRA TRANSPARENCY REPORTS rd Pl SE, Maple Valley, WA April 4 th, 2017

BUILDER S PRE-INSPECTION CHECKLIST

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

FAIRA TRANSPARENCY REPORTS NE 178th St, Lake Forest Park, WA May 2 nd, 2017

FAIRA TRANSPARENCY REPORTS Interlake Ave N, Seattle, WA February 1, 2018

Certificate of Inspection CHECKLIST

Inspector FX Field Forms

Home Inspection Report

Home Set-up and Maintenance. Maintenance

A DO-IT-YOURSELF GUIDE TO ENERGY STAR HOME SEALING SEALING AIR LEAKS AND ADDING ATTIC INSULATION

United States Environmental Protection Agency

Installation Instructions DAR 1150, DAR 1220 DAR 1230, DAR 1250

Space Coast Home Inspections LLC

FAIRA TRANSPARENCY REPORTS W James St, 8, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS

1152 Vinetta - Des Peres The Wakefield Model $634,900

SPS Home Inspections, LLC

26632 Timberlane Dr SE, Covington, WA 98042

Conversion to Vacation Home Permit Life Safety Survey

BUILDER S PRE-INSPECTION CHECKLIST

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

Transcription:

1.9 ROOFING, FLASHING, CHIMNEYS Downspouts 2.7 EXTERIOR Soffit, Fascia, & Trim No extension. RECOMMENDATION: Add 5' extension at NE. Spout discharges to roof. ELECTIVE MODIFICATION: Extend spout to gutter or to 2.3 EXTERIOR Walks Stains and water damage on rear eave near door from addition. RECOMMENDATION: Correction by a qualified painter. See downspouts. 2.10 EXTERIOR Windows, exter. Insulated glass in rear addition win Settled at front step creating a riser that increases the potential for falls. RECOMMENDATION: Correction by a qualified concrete repair firm to reduce Several windows have peeling paint. RECOMMENDATION: Correction by a qualified painter. (See new US EPA lead paint rules effect. 4/1/2010) 03/22/10 Page 1

2.14 EXTERIOR Stoops & Stairs 2.19 EXTERIOR Gar. Walls/Fnd./Fire Separ. Tall riser due to settled walk. See walk. 2.17 EXTERIOR Garage Door Opener(s) Attic hatch for space over laundry is 1/4" plywood instead of gypsum wallboard. Gaps in drywall around rafters over laundry. RECOMMENDATION: Correction 3.3 STRUCTURE Floor (lowest level) Light beam sensor operated auto-reverse. Impact reverse not tested. Test monthly on 2" wood block. Crawl space soil covered with plastic, however, atop the plastic are numerous pieces of siding some metal ducting, and other debris. Also see insulation. 03/22/10 Page 2

3.6 STRUCTURE Bsmt. Stairs & Railings 3.13 STRUCTURE Attic Access: viewed from Handrail has straight ends which could hook loose garments. ELECTIVE MODIFICATION: Correction by a qualified carpenter. (Handrail with returns) 3.12 STRUCTURE Chimney/Vent in Attic No weatherstripping on attic hatch. ELECTIVE MODIFICATION: Weatherstrip and secure the hatch to reduce air flow into the attic. 3.14 STRUCTURE Attic Insulation/Vapor barrier Air leak from house to attic at vent is likely. RECOMMENDATION: Seal leaks. Portion of area N of hatch has compressed insulation from foot traffic. ELECTIVE MODIFICATION: Have a qualified insulation firm add or redistribute 03/22/10 Page 3

3.17 STRUCTURE Insul. @ Found., Rim., Floor 4.8 ELECTRICAL Ground Fault Interrupters Test GFCI devices monthly Several loose pieces of flammable foam plastic are found in the basement, on ducts and as cover for the crawl space access. RECOMMENDATION: 4.5 ELECTRICAL Wiring at service panel GFCI's advised at wet or ground areas: Kitchen, Exterior, baths, laundry, basement, Garage, etc. 5.3 HEATING & COOLING Draft Regulator/Air supply Wire on top left 20 amp breaker has melted insulation. One improper double connection on a breaker below it. RECOMMENDATION: Correction by a Air supply tube has been extended and looped in such a way that its ability to deliver air TO the basement is greatly reduced. RECOMMENDATION: 03/22/10 Page 4

5.4 HEATING & COOLING Combustion Venting 5.6 HEATING & COOLING Distribution Ducts/Pipes No draft stop collar around vent at subfloor. RECOMMENDATION: Correction by a qualified HVAC firm. 5.5 HEATING & COOLING Blower or Pump Unsealed seams & joints in basement returns reduce air circulation at upper levels. RECOMMENDATION: Correction by a qualified HVAC firm. 6.2 PLUMBING Water Pipes-Flow Blower cabinet door is bent and held on with screws and metal foil tape. There are untaped gaps at top right and top left of the door. This permits the blower to Condensation stains below uninsulated cold water pipe. ELECTIVE MODIFICATION Insulate water pipes to reduce the potential for condensation 03/22/10 Page 5

6.8 PLUMBING Water Heater venting 6.15 PLUMBING Laundry Connections washer/dryer not operated Installed with a slow opening thermal vent damper that permits the spillage of fumes for about a minute during heater startup. RECOMMENDATION: Have 6.10 PLUMBING Fuel Lines & Main valve Main gas valve above furnace Laundry tub faucet spout lacks a vacuum breaker. ELECTIVE MODIFICATION: Install a vacuum breaker. NOTE: Review of photo does NOT reveal a dryer 7.7 INTERIOR & APPLIANCES Windows/skylights Unapproved flex. brass gas connector at dryer. RECOMMENDATION: Correction by a qualified gas pipe fitter. Also peeling and loose paint in window sills. RECOMMENDATION: Correction by a qualified painter. (See new US EPA lead paint rules effect. 4/1/2010) 03/22/10 Page 6

7.19 INTERIOR & APPLIANCES House/Garage Door Storm door not needed. RECOMMENDATION: Remove storm door. Door lacks a self closer. RECOMMENDATION: Correction by a qualified carpenter. (closer 03/22/10 Page 7