PLEASE READ THIS USER GUIDE CAREFULLY

Similar documents
PLEASE READ THIS USER GUIDE CAREFULLY

PLEASE READ THIS USER GUIDE CAREFULLY

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

User guide. for smoke detector

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

CAVIUS NANO LIMITED. 8 King Street, Te Puke 3119 Bay of Plenty, New Zealand. PO Box 11241, Papamoa 3118 Bay of Plenty, New Zealand

USER MANUAL 10 YEAR LIFE SMOKE ALARM

Wireless Interlink Smoke Alarm + 10 Year Life

Smoke Alarm User Manual

Smoke Alarm User s Manual

NG-9B NATURAL GAS ALARM

_V1.qxd:_ :27 AM. Ionisation Sealed Smoke Alarm with Ten Year Lithium Battery & Hush. Manual. Model Q910

169MHz Telecare Devices Carbon Monoxide Detector

1 Introducing Eve Smoke

WIRELESS PHOTOELECTRIC SMOKE ALARM

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Smoke Alarm User Manual

Smoke Alarms and Carbon Monoxide Alarms

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Smoke Alarm Legislation

Protecting you and your home

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Smoke Alarm User s Guide

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

U S E R M A N U A L UBH1RF HEAT ALARM

INSTALLATION AND USER MANUAL

Smoke Alarm. 120V AC Ionization. Smoke Alarm. Back-up. with 9V Battery

Smoke Alarm User s Guide

USER S GUIDE. Smoke Alarm. Battery-powered

Photoelectric Smoke Alarm User s Guide

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

RMS-I-DE-01 Smoke Detector

Wireless Base Remote Test and Hush

1. Safety instructions Mounting location in rooms of the heat detectors... 3

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Smoke Alarm User Guide

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

_EN_V4:_ :46 AM Page 1 USER S MANUAL 0086-CPD

MODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS

Invensys Controls Americas

Melrose Fire Department

Smoke Alarm with RF Interlink User Guide

INSTRUCTION MANUAL PC255O

SMART SMOKE DETECTOR

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

_V4:_ :28 AM Page 1. For model 29D,29HD. Photoelectric Smoke Alarm. User Guide

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

Visit Us on the Web! MODEL SS-795 EARLY WARNING SMOKE & FIRE ALARM WITH SILENCE CONTROL

INSTRUCTION MANUAL PC255O

INSTALLATION AND USER MANUAL

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

SAFEGUARD YOUR HOME WITH QUELL

Wireless Smoke Alarm User s Guide

Home Doorway Alert Kit

120V AC Smoke Alarm with 9V Battery Back-up

Smoke Alarm User s Guide

ONLY WORKING SMOKE ALARMS SAVE LIVES

LIFETONE HL TM. Bedside Fire Alarm & Clock. User s Manual MODEL HLAC XI. RECOMMENDED LOCATIONS FOR SMOKE ALARMS ENGLISH SPANISH

C8600A CO Alarm OWNER S GUIDE RESIDENTIAL USE ONLY

Smoke Alarm User s Guide

Smoke Alarm User s Guide

Carbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings

Smoke alarm Installer s Manual

Heat Alarm. Owner s Manual. Model CFH10. Rate of Rise Temperature Sensing Selectable Fixed Temperature Sensing Proprietary Wireless Connectivity

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

OWNER'S MANUAL PLEASE READ AND SAVE!

OPERATION & MAINTENANCE INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz

Smoke Alarm User s Guide

Smoke Alarm User s Guide

WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR DÉTECTEUR DE FUMÉE PHOTOÉLECTRIQUE SUPERVISÉ SANS FILS. Model: EL-2703

Heat Sensor. Owner s Manual

Watchguard Fire and Theft

This Heat Alarm must only be wired to a 240Vac 50Hz sine wave current supply.

INSTALLATION AND USER MANUAL

GBC BLIZZARD A4 & A3 Laminators. Instruction Manual

Fire Safety Prices include 20% Subject to availability. Prices may vary Pictures and specifications are a guide only

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Smoke Alarm. Owner s Manual. Model CFS10. Combination Alarm

Smoke Alarm User s Guide. AC Wire-in Single and/or Multiple Station (up to 24 Devices) Photoelectric Smoke Alarm with 9 Volt Battery Back Up.

Introduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca

MK9 series CarePhone. Installers Mauual

3.1 Introduction. 3.1 Introduction

GT-1D. Residential/Tenant Station OPERATION MANUAL

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

Approved Document for New Zealand Building Code Warning Systems Clause F7 Third Edition

Smoke & Carbon Monoxide Alarms

ESCAPE LIGHT SMOKE ALARM LSI-601 ESCAPE LIGHT TOAST PROOF SMOKE ALARM LSO-601

Smoke Alarm User s Guide

PC56O. Instruction Manual

MFES READY Make your home fire safe. Home Smoke Alarms

THUNDER LOW FREQUENCY AMPLIFIER INSTALLATION MANUAL

Owner s Manual.

Smoke Alarm User s Guide

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

RADION smoke RFSM-A. en Installation Guide

Transcription:

PLEASE READ THIS USER GUIDE CAREFULLY

Cavius DIY Smoke Alarm Model 2008-002 / 10012 / 10013 / 10014 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. For large text option and maintenance guide visit www.cavius.co.nz/resources www.cavius.com.au/resources 1.

2. The CAVIUS is smoke alarm is a photoelectric alarm designed to be installed into residential homes, camper-vans and caravans. It is not recommended for boats. CERTIFIED TO AUSTRALIAN STANDARD AS3786:2014

MOUNTING BASE TEST/ HUSH BUTTON CHAMBER FILTER ALARM AUDIBLE ALERT 3.

The best locations in your home to install the smoke alarm: Place a smoke alarm between possible fire sources and bedrooms as a minimum. Smoke alarms on each floor, in hallways and stairways. Smoke alarms in each room such as bedrooms and living rooms. Additional smoke alarms will increase the security. The NZ and Australian Fire Services recommend smoke alarms in every bedroom, hallway and living area for early fire detection. 4.

MINIMUM INSTALLATION OPTIMUM INSTALLATION 5.

Installation of smoke alarm: Info: The label in the product must not be removed due to important information regarding the product. MARK UP SCREW HOLES WITH A PEN 1. Use the mounting base ring to mark the screw holes on the ceiling. Use the enclosed screws and plugs for installing the mounting base. 6.

USE THE ENCLOSED SCREWS AND PLUGS FOR INSTALLATION CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE 7.

Placement: Designed for placement on ceiling (preferred) or wall. The smoke alarm should be a minimum 50 cm from the wall, with a minimum of one smoke alarm per floor and a maximum distance between smoke alarms of 10 metres. MINIMUM 50cm FROM WALL CEILING CEILING MINIMUM 30cm AND MAXIMUM 50cm FROM CEILING 50cm 8. WALL WALL

2. After mounting, allow 5 seconds for the alarm to power up and then test the smoke alarm by pushing the test button (which is the entire top of the alarm). The alarm should produce a loud sound 9.

10. The smoke alarm may NOT be placed: In dusty rooms At the top of high pointed ceilings, instead place a minimum of 50cm to a maximum of 150 cms from the appex. Within 50cm of a wall. In rooms where the temperature goes outside +5º to 45ºC or above 90% relative humidity non condensing. In kitchens, garages, or too close to fireplaces. In areas that get damp or where gases may occur. Place the smoke alarm where it is reachable in order to test the battery and complete maintenance.

Maintenance: The smoke alarm should be vacuum cleaned once per quarter, and can be wiped with a slightly damp cloth (do not open the alarm). Test the smoke alarm once per month by pushing the test button. The smoke alarm should produce a loud alarm tone. 11.

12. FUNCTIONAL INFORMATION Type of alarm: CAVIUS smoke alarm is a photo electric smoke alarm. Alarm signal: Fire alarm activation is indicated by a series of repeated tones. The minimum sound level is 85 db at 3 metres. Battery: Powered by a non-replaceable 3v CR123 A DURACELL Lithium battery with 10-year life (included).

Low battery indicator: A short acoustic beep will sound and the LED will flash every 48 seconds when the battery is near the end of its life. In this stage it will continue for a minimum of 30 days. You must change the smoke alarm after 10 years of use, or if the smoke alarm has suffered any damage. The smoke alarm is not active unless it is clicked into the mounting base. Always test the smoke alarm after clicking into the mounting base, allow 5 seconds before testing. 13.

14. Smoke alarm signal: The smoke alarms have a visual and acoustic signal. In the passive state, the LED will flash every 48 seconds to indicate normal function. In alarming state the LED will flash and the alarm will emit a sweeping sound pattern designed to alert occupants.

Hush function: In case of unintentional or false alarms, press the hush button for 2 seconds (which is the entire bottom of the alarm). This will mute the alarm for 10 minutes, after which time the alarm will automatically resume its normal function. 15.

Fault finding: If the smoke alarm activates without a visible smoke or fire presence, then possible causes could be: Dust particles which have entered the smoke chamber, these can be removed by vacuuming around the mesh. If the smoke alarm does not work when the test button is pushed, please check our Trouble Shooting Guides at; www.cavius.co.nz and www.cavius.com.au 16.

Other information: Do not paint the smoke alarm. Note the local country regulations regarding installation of mains powered smoke alarms in new buildings. Disposal: For battery and product, please dispose properly at end of life. This is electronic waste that should be recycled. 17.

MANUFACTURED BY: Aps Julsøvej 16 - DK8600 Silkeborg www.cavius.com - info@cavius.com Manufactured in P.R.C. DISTRIBUTOR INFORMATION: CAVIUS Nano Ltd. 8 King Street, Te Puke. 3119, Bay Of Plenty 3118. P.O Box 11241, Palm Beach Plaza, Papamoa, Bay Of Plenty 3151, New Zealand. www.cavius.co.nz Hotline: 0800 766533 or 07 542 2191 REP ELEC. Locked Bag 45, Plumpton, NSW 2761, Australia. www.cavius.com.au - PH: 1300 555 586 18.

Warranty: Your CAVIUS smoke alarm has a 5 year warranty from the date of purchase against defect in material and workmanship. Faulty units during this period can be returned to the place of purchase. You must provide the proof of purchase date and such defects will be repaired, or replaced at the distributors option, without charge. This Warranty only covers defects in materials or workmanship in normal residential use and does not cover damage resulting from negligent handling, misuse or lack of reasonable care. This warranty is in lieu of any other warranty either expressed or implied. AS3786:2014 Model Number 2008-002 / 10012 / 10013 / 10014 126982 rev2 19.

Product overview: Type of mounting Main power supply Battery duration Ceiling and Wall Mounting Internal power source (battery included) 10 years 20. Interconnectable device Yes No Suitable for installation in mobile home Yes No

Connection to external auxiliary devices Yes No Radio link Yes No Individual alarm indicator Yes No Alarm silence facility (10min) Yes No No radioactivity infrared technology Yes No Accessibility option Yes No 21.