PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Similar documents
PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

DRAFT. Module 4. Decontamination & Environmental Cleaning

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

Washroom. PURPOSE: To provide clean washrooms for staff, visitors and patients MATERIALS: 19-1

Commit 2 Clean TM/MC. Bloodborne Pathogens Awareness Program

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Occupied Room (All Areas) PROCEDURE NO: 032

CLEANING INSTRUCTIONS

RESTROOMS. Proper daily cleaning procedures. Custodial Best Practices

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Restrooms. Proper daily cleaning procedures. Custodial Best Practices

SANITARY PRACTICES POLICIES AND PROCEDURES

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

2015 Myco Industries, Inc Fax:

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

INFECTION PREVENTION AND CONTROL ENVIRONMENTAL AUDIT TOOL

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

CleaningProtocol. Guidelines for Frontline Staff

PIHA DUTIES HANDBOOK. 64 Glenesk Road, Piha

Special Precautions Isolation Plan Environmental Services

MELBOURNE ADELAIDE SYDNEY BRISBANE PERTH

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Jennings Street School

4/8/2014 GOAL PATIENT EQUIPMENT

The individual indicated in the responsible person column must decontaminate the item as indicated in the method column.

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

FLOOR FINISH. Extended Performance Floor Finish

Daily Office Cleaning

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Dietary Department, Infection Control

PLANT OPERATIONS CLEANING PROTOCOL

Housekeeping. Note. Areas that are not covered under contractor services must adhere to the same cleaning standards as specified in this section.

Washroom care programs

For routine maintenance of polished granite installations with a cleaner and protector:

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

Cleaning and Sanitation Procedures Module Cafe/Dining Restroom

When you sterilize an instrument set, you know what the standards are.

HOMES AND SENIORS SERVICES. APPROVAL DATE: April 2004 REVISION DATE: March 2016 REVISION DATE: March 2017 REVIEW DATE: November 2018

Cleaning Schedules for Childcare Facilities. Management of Infectious Disease in Childcare Facilities and Other Childcare Settings

STANDARD OPERATING PROCEDURE

Task Definitions Exhibit C. Task Definitions: The following definitions outline minimum acceptable standards for the activity to be performed.

Checklist for final cleaning camp buildings Page 1 of 3. As you clean, please report anything that is broken, damaged, or not working properly.

Best practices in Cleaning and Safety

HYGIENE, CLEANING AND INFECTION CONTROL POLICY

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

Daily Office Cleaning

CLEANING AND SANITATION Policy Owner: Erica Tennessen Policy Originated by (program or department): Program Applicable Programs: All Programs

Washroom care programs

Disinfecting And Sanitizing Animal Facilities

AMITY INTERNATIONAL (U.K.)

Safety procedures: Wear your PPE. Gloves and goggles when filling the chemical bottle, using the machine, and cleaning the machine.

JANITORIAL SPECIFICATIONS

BASIC OFFICE CLEANING GUIDE FOR GENERAL

Cleaning and disinfecting

CUSTODIAL TRAINING GUIDE RESTROOM CARE

HYGIENE AND SANITATION

Cruise Line Cleaning and Disinfection Protocol for Environmental Services / Housekeeping

REGULAR MAINTENANCE AND CARE

GENERAL CLEANING General Cleaning

Task Definitions Exhibit C. Task Definitions: The following definitions outline minimum acceptable standards for the activity to be performed.

Bedroom Cleaning Standards: Sunrise Village

LAUNDRY POLICY Page 1 of 6 Reviewed: February 2017

Layout and Design by T. Palimenio, Picture credit: Freepik. Cleaning Manual

! It is the responsibility of every team

Holland Park Child Care Centre

Start the cleaning from Left and finish at Right. Always do the floor last, start from inside and finish at doors

Cleaning and Sanitation Procedures Module Deli

Cleaning Up After Rodents

Cleaning & Sterilization

Harvey Chemiclave 5000 Owner And Operator Guide

Cleaning Household Linens and Furnishings

THE BASICS OF DECONTAMINATION

Administration of AMBISOME Using the GemStar Pump

Copyright 2016 The Oil Posse beoilamazed.com

Instructions for Use Spinal Punches IFU

ACE CLEANING SUPPLIES

Recommended Floor Care Procedures

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Patient Discharge (All Areas) PROCEDURE NO: 033

The Lee Wiggins Childcare Centre ENVIRONMENTAL CLEANING AND DISINFECTING POLICY AND PROCEDURE

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

I.F.U Re/Processing Reusable Medical Devices

CARE & MAINTENANCE FACT SHEET OUTDOOR LOUNGE

S-pod / ALTOR BATHROOMS MAINTENANCE NOTICE

Mechanical Ware Washing

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Hantavirus Procedures

IFU 005 CLEANING / PREPARATION OF OUTDOOR HEAT EXCHANGE SURFACES & COILS. Date Approved

Methods & Procedures. Operational Cleaning

MUSEUM HOUSEKEEPING. Preventative Conservation: Artefacts & Structures

COMPREHENSIVE INSTRUCTIONS For All Your Home Cleaning Needs

1. Protective hand wear non-sterile latex or cloth gloves 2. Protective mask (if needed for dust)

Discharge and Transfer Cleaning

PERFORM Operating Document

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ]

triple7 Municipal Environmental Solutions

FLOOR CARE. Avmor s Floor Care Training Guide

Details for Cleaning Checklist

Transcription:

THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10SCXD, rinse with - Wash off visible dirt (e.g. blood) using F10SCXD CHAIRS - Trigger spray using F10SC and wipe down with paper towel CUPBOARDS/SHELVES - Wipe down (damp dust) using F10SC and clean cloth FLOS - Sweep or rinse away all debris - Wash thoroughly using F10SCXD & broom or HP Washer, rinse with - Apply F10SC through fogging machine or garden sprayer through HP washer, leave for 5 minutes, scrub lightly with broom and rinse with clean. When using with cold, allow contact FLO DRAINS - Remove drain covers/traps and scrub with F919SC - Flush with large volumes of clean - Pour 1 litre of diluted F10SC down drain AIR SPACES - Fog air spaces using F10SC through fogging machine or garden sprayer - Use F10 DISINFECTANT AEROSOL FOGGER OVERHEAD HOIST MECHANISM AND SHACKLES - Wash thoroughly using F10SCXD and brush or HP Washer, rinse with - Apply F10SC through fogging machine or garden sprayer through HP washer, leave for 5 minutes, scrub with broom and rinse with clean. When using with cold, allow contact time of 10 15 min before scrubbing EQUIPMENT(O/H LIGHTS, Q-CARTS,SUCTION BOTTLES,FACE MASKS,ET TUBES,ANAESTHETIC EQUIPMENT,ULTRASOUND PROBES,ECG MACHINE AND CABLES,DRIP STANDS) - Wash/wipe all surfaces from top to bottom using F10SCXD, rinse with - Wash bottles and tubing using F10SCXD, rinse with - Apply F10SC to all surfaces - Rinse bottles and tubing using F10SC - Spray out tubing using F10 DISINFECTANT AEROSOL THERMOMETERS - Use two sets, one in use and one stored dry - wipe with disposable paper - Wipe using F10 WIPES or spray with F10SC and wipe with paper towel SCOPES( ENDOSCOPES/GASTROSCOPES/ARTHROSCOPES) - Follow manufacturers instructions with regards to rinsing procedure after use, as well as use of enzymatic agent - Rinse for 1 minute. Wash using F10SCXD for if mechanical (5 minutes if ultrasonic), rinse for 1 minute - Soak in F10 STERILANT (RTU) for, rinse with sterile or use without rinsing - Soak in F10SC (1:100) for, rinse with sterile or use without rinsing - NOTE: If a gluteraldehyde had been used to disinfect the instrument, it must be thoroughly washed and wiped with alcohol before immersed in F10. A reddish residue may form on the instrument as the result of the interaction between aldehyde and F10. This will not damage the Instrument and can be avoided by thorough cleansing to remove aldehyde residues ELECTRIC RAZS AND BLADES - Scrub with nylon brush using F10SCXD, rinse with When visibly /after use /after use / cleaning // 40ml/10l 5 min warm 10 min cold 5-10 min 5 min warm 10 min cold Page of 6 Page 1 of 5

- Trigger spray using F10SC - Apply blade wash/lubricant - Store dry ENDOTRACHEAL TUBES - Wash thoroughly with F10SCXD (rinse lumen thoroughly to clear away mucous) - Soak in F10SC - soak in F10 STERILANT (RTU) - Rinse with sterile remove without rinsing - Store clean and dry NEEDLES,SYRINGES,I/V CATHETERS,DRIP SETS,SUTURE MATERIAL,NAIL BRUSHES - Single use is safest and best practice! - Do not store in disinfectant - Wash using F10SCXD, rinse with - Soak in F10 STERILANT(RTU) - Rinse with sterile Remove without rinsing - Store clean and dry INSTRUMENTS - Cover instruments with sterile damp swab to avoid blood drying on them - Wash thoroughly in lukewarm and F10SCXD using a soft nylon brush - Dry thoroughly and lubricate with instrument lubrication. Dry - Sterilize through moist steam or cold sterilization process COLD STERILIZATION - Fully immerse clean and dry instruments in fresh solution of F10 STERILANT(RTU) - Remove using sterile instrument or wearing sterile gloves(rinse with sterile use without rinsing) - Use immediately or store in sterile container AIRCON SYSTEMS - Remove filters, apply F919SC, leave for 10 min, scrub lightly, rinse with - Immerse filter in F10SC - F10SC can also be sprayed or fogged into air ducting WASTE BINS - Remove plastic liner, tie closed and discard - Wash down using F10SCXD, rinse with - Trigger spray with F10SC inside new liner as well as top of bin TELEPHONES/LIGHT SWITCHES/DO HANDLES - Trigger spray using F10SC onto paper towel or clean cloth and wipe down WK SURFACES /THEATRE TABLE/ INSTRUMENT TROLLEYS/THEATRE TABLE MATTRESS) - Wash visible debris off with clean - Wipe down with F10SC in trigger spray bottle and clean cloth - Wash all surfaces from top to bottom using F10SCXD, rinse with clean through HP washer, leave for 5 minutes, scrub lightly with broom and rinse with clean. When using with cold, allow contact SOAP DISPENSERS - Fill dispensers halfway. DO NOT TOP UP - When bottle is empty, wash using hot and F10SCXD - Trigger spray nozzles using F10SC BASINS - Wash thoroughly with F10SCXD, rinse with - Trigger spray with F10SC HAND HYGIENE Sterile & invasive procedures - Wash hands with F10 HAND SCRUB & luke warm, while keeping hands higher than elbows& using friction for 2 minutes,rinse,close tap with elbows,dry hands with sterile towel from fingers to elbows During procedure procedure and when required /weekly/ when / /when Before filling /after use /after use /after use Before procedure for 2 minutes 40ml10l 30 minutes 5- Page 2 of 5

General practice - Wash hands with F10 ANTISEPTIC LIQUID SOAP using friction for 30 seconds, rinse, dry hands with paper towel & use paper to close tap - Use F10 HAND GEL as alternative for decontamination of hands PATIENT SKIN PREPARATION - Clip wide area neatly and as short as possible using clean no 40 blade - Wash area thoroughly using F10 HANDSCRUB F10 ANTISEPTIC LIQUID SOAP and lukewarm, dab away excess moisture. Repeat until no visible dirt is left on skin - Spray F10SKIN PREP (RTU) and wipe with clean swab. Repeat - Move patient onto operating table, spray surgical site with F10 SKIN PREP (RTU) PROTECTIVE CLOTHING (SCRUBS, THEATRE GOWNS, OVERALLS, DRAPES) - Soak item in F10SCXD prior to washing - Wash in washing machine, hang in sun to dry or use tumble dryer - To eliminate persistent odours, add approximately 100ml of F10 ODOUR ELIMINAT to wash CLEANING EQUIPMENT - Use brooms & brushes with nylon bristles & plastic backing where possible - Rinse clear of all debris - Wash brooms, brushes, cloths thoroughly in F10SCXD, hang to dry (do not rinse) - Scrub buckets & mop trolleys with F10SCXD, rinse with - Start shift with clean and dry equipment X-RAY EQUIPMENT (LEAD GLOVES AND GOWNS) - Wash using F10SCXD if visibly - Trigger spray using F10SC and wipe down with paper towel. INSECT CONTROL - Spray walls and ceilings in areas where fly control is required lightly with F10 ENVIRONMENTAL SPRAY WITH INSECTICIDE, repeat daily for 3 days, thereafter every 10 14 days or as required cases/after contamination for cases/after contamination. (30 sec) Before procudure for a week or as required If visibly for 3 days Every 14 days As required 1 ml (for 30 sec) 30 minutes Page 3 of 5

STABLE AREA STABLES (WALKWAYS/PASSAGES)WALLS & DOS - Muck out and remove debris - Wash all surfaces from top to bottom using F10SCXD, rinse with FLOS - Wash using F10SCXD with broom or HP Washer, rinse with SPRING CLEAN through HP washer, leave for 5 minutes, scrub lightly with broom and rinse with clean. When using with cold, allow contact WATER & FOOD TROUGHS / BUCKETS - Rinse thoroughly, apply F919SC, leave for 10 min, scrub lightly, rinse with CRUSHES/PROCEDURE AREAS - Remove debris - Wash/Scrub using F10SCXD with broom or HP Washer, rinse with CLEANING EQUIPMENT - Use brooms & brushes with nylon bristles & plastic backing where possible - Rinse clear of all debris - Wash brooms, brushes, cloths thoroughly in F10SCXD, hang to dry (do not rinse) - Scrub buckets & mop trolleys with F10SCXD, rinse with - Start shift with clean and dry equipment DRAINS - Remove drain covers/traps & scrub with F919SC - Rinse with - Flush with large volumes of clean - Pour 1 l of diluted F10SC down drain EQUIPMENT (HALTERS, TACK, SADDLE CLOTHS.GROOMING EQUIPMENT) - Apply F10SC to all surfaces through trigger spray bottle - Wash all surfaces from top to bottom using F10SCXD, rinse with, hang out to sun dry SEASONAL INSECT CONTROL & HYGIENE - Spray walls and ceilings in areas where fly control is required lightly with F10 ENVIRONMENTAL SPRAY WITH INSECTICIDE, repeat daily for 3 days, thereafter every 10 14 days or as required / discharge / discharge With change of each season deep cleaning discharge/ discharge/ / horses for 3 days Every 14 days As required /1l 5- Hang to dry Hand to dry HAND HYGIENE SOILED/VISIBLY DIRTY HANDS - Wash hand with F10 ANTISEPTIC LIQUID SOAP using friction for 30 sec, rinse, dry thoroughly BETWEEN HSES - Dispense F10 HAND GEL onto hands, rub over all surfaces, allow to air dry - Spray hands with F10SC and leave to dry(use trigger spray bottle) When visibly dirty handling horses, when hands not visibly 1ml /1l TRANSPT AFTER USE - Wash all surfaces from top to bottom using F10SCXD, rinse with each use Page 4 of 5

ISOLATION IN CASE OF INFECTIOUS DISEASES E.G. SALMONELLA, STRANGLES HAVE DEDICATED STAFF ASSIGNED TO ISOLATED CASES HAVE DEDICATED TACK & GROOMING EQUIPMENT MAKE USE OF FOOT BATHS CRECT HAND HYGIENE! DO NOT USE HIGH PRESSURE WASHER ENVIRONMENT STABLES: WALLS & DOS & WALKWAYS/BREEZEWAYS - Spot clean contaminated areas in stable using F10SCXD, rinse with - Wash all surfaces from top to bottom using F10SCXD, rinse with. DO NOT use high pressure cleaner for infectious cases - Apply F10SC to all surfaces through garden sprayer or fogging machine - Remove all bedding and place in plastic bags, tie closed through HP washer, leave for 5 minutes, scrub lightly with broom and rinse with clean. When using with cold, allow contact WATER & FOOD TROUGHS/BUCKETS through HP washer, leave for 5 minutes, scrub lightly with broom and rinse with clean. When using with cold, allow contact - Scrub using F10SCXD and nylon brush, rinse with FOOTBATHS - Scrub using F10SCXD, rinse with - Fill with F10SC to level of at least 15cm EQUIPMENT HALTERS, TACK, SADDLE CLOTHS, GROOMING EQUIPMENT & CLEANING EQUIPMENT - Apply F10SC to all surfaces through trigger spray bottle - Wash all surfaces from top to bottom using F10SCXD, rinse with HAND HYGIENE AFTER HANDLING HSE, EQUIPMENT - Wash hand with F10 HAND SCRUB using friction for, rinse, dry thoroughly BETWEEN HSES - Dispense F10 HAND GEL onto hands, rub over all surfaces, allow to air dry - Spray hands with F10SC and leave to dry(use trigger spray bottle) TRANSPT AFTER USE - Wash all surfaces from top to bottom using F10SCXD, rinse with 80ml/10l discharge/ 80ml/10l 80ml/10l Once horse has been removed discharge discharge/ discharge/ discharge/ Replace daily or when visibly & after horse removed from isolation making contact and before handling other horses or their equipment. handling horses, when hands not visibly each use before transporting other horses. 80ml/10l 80ml/10l 80ml/10l 80ml/10l 80ml/10l 80ml/10l 1ml /1l 80ml/10l 80ml/10l 5- NOTE: F FULL INFMATION ON PRODUCTS MENTIONED ABOVE REFER TO OUR PRODUCT INFMATION LEAFLETS. Health and Hygiene (Pty) Ltd Oct 2009 update Page 5 of 5