Level Electrode NRG NRG Original Installation Instructions English

Similar documents
Level Electrode NRG Original Installation Instructions English

Conductivity Electrode LRG Original Installation Instructions English

NRG NRG NRG NRG

Installation & Operating Instructions

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

Temperature Sensor TRG Original Installation Instructions English

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

GESTRA Steam Systems NRGS 11-2, NRGS Installation Instructions Level Electrode Types

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

GESTRA Steam Systems NRS For TWO Electrodes. English. Installation Instructions Level Switch NRS 1-50

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

SMK 22 SMK SMK SMK 22-82

GESTRA. GESTRA Steam Systems NRS For ONE Electrode. English. Installation Instructions Level Switch NRS 1-50

GESTRA Steam Systems OR 52-5 OR English. Installation & Operating Instructions Oil & Turbidity Detector OR 52-5, OR 52-6

BK 45 BK 45-U BK 45-LT BK 46

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

BK 46. Installation Instructions Steam Trap BK 46

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

GESTRA. GESTRA Steam Systems TRS English. Installation & Operating Instructions Temperature Switch TRS 5-50

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Model: 1100 Float-Controlled Condensate Trap, PN 25

VERSAFLOW VORTEX Supplementary instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Product overview. the optimum components for every application

GESTRA Steam Systems OR English. Installation Instructions Oil & Turbidity Detector OR 52-7

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Survey of electrical equipment installed in hazardous areas on tankers

Mechanical seals external, single or double, to DIN EN 12756

GESTRA. Product Overview. The optimum components for every application

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTRUCTION MANUAL (ATEX / IECEx)

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

GESTRA. Product Overview. The optimum components for every application

1592P01. for liquids in piping DN

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Water level controller and limiter

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

EXFG Oxygen Analyzer System. Installation Guide. EXFG Probe. ABB Process Analytics

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Supplementary Installation and Operating Instructions. Category II2G

CORREX MP Anode with external voltage source. Installation & Operation Manual

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Centurion Guided Radar HAWK CGR SERIES

Installation, operating and servicing instructions

Operating and installation instructions

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Consignes d installation

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Distinction. D4000 & D4000/EURO Water Still. Assembly and Operating Instructions. 1 Issue 2

Withdrawable module with vacuum circuit-breaker 3AE and installation accessories kv, ka kv, 40 ka 24 kv, ka

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

ph Measuring System Start-up and maintenance manual e Contents

GENERAL SPECIFICATION ELECTRICAL

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Installation and maintenance instructions

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Installation manual plugs and connectors QUICK-CONNECT (63 A)

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

! WARNING. Before using product, read and understand instructions.

High Output Vacuum/Pressure Pump

Model: AC-108. Instruction Manual

PA ma Loop Powered Level Preamplifier

Hazardous Area Zirconia Oxygen Systems

Service Instructions

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

CalMag Filter Installation Instructions

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Calio-Therm S NC/NCV Type Series Booklet

Instructions for Installation, Operation, Care and Maintenance

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

FSW300 Series Flow Switch

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

INSTALLATION INSTRUCTION

Heating Mats and Jackets. innovations in heat tracing

Condensate Recovery and Return System SDR A

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Mounting and Operating Instructions EB 2231 EN

Regulux. Radiator lockshield with drain-off facility. To be precise.

Transcription:

Level Electrode NRG 10-52 NRG 16-52 EN English Original Installation Instructions 819123-02

Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards VdTÜV Bulletin Wasserstand 100 (= Water Level 100)...5 ATEX (Atmosphère Explosible)...5 Note on the Declaration of Conformity / Declaration by the Manufacturer...5 Technical data NRG 10-52, NRG 16-52...6 Scope of supply...6 Name plate/marking...6 Installation Tools...7 Dimensions NRG 10-52, NRG 16-52...8 NRG 10-52, NRG 16-52, step 1...9 NRG 10-52, NRG 16-52, step 2...9 Table Functions...9 Key...9 Examples of installation NRG NRG 10-52, NRG 16-52...10 Key...11 2

Contents - continued - Electrical connection Page NRG 10-52, NRG 16-52 with five-pole connector...12 Key...12 Tools...12 Connection of level electrode...13 NRG 10-52, NRG 16-52 - connecting the five-pole connector...13 Connecting terminals in contact block...13 Commissioning, fault indication and troubleshooting...14 Removing and disposing of the level electrode Removing and disposing of level electrode NRG 10-52 / NRG 16-52...14 3

Important notes Usage for the intended purpose The level electrode NRG 10-52 / NRG 16-52 in conjunction with level switch NRS 1-.. is designed for signalling up to four different water levels and used for instance in steam boiler plants and (pressurized) hot-water installations or in condensate and feedwater tanks, e. g. as water level limiter with MIN/MAX alarm. The level electrode is designed for use in conjunction with the following level switches: NRS 1-52, NRS 1-53, NRS 1-54 and NRS 1-55 or NRS 1-1, NRS 1-2, NRS 1-3 and NRS 1-5. Function The electrode operation is based on the conductive measuring principle using the electrical conductivity of the water for signalling water level. The length of the individual electrode rods determines the switchpoints for the respective water levels. The level electrode is installed inside steam boilers, vessels or in an external level pot. If the electrode is installed inside the boiler or vessel, a protection tube provided on side ensures correct functioning. (see section Examples of installation on page 10). The level electrode can be installed together with one GESTRA level electrode for water level limiting or for high-level alarm in a single protection tube or external level pot. Safety note The equipment must only be installed, wired and commissioned by qualified and competent staff. Retrofitting and maintenance work must only be performed by qualified staff who - through adequate training - have achieved a recognised level of competence. Danger When loosening the electrode steam or hot water might escape! This presents the risk of severe scalding all over the body! It is therefore essential not to dismantle the electrode unless the boiler pressure is verified to be 0 bar. The electrode becomes hot during operation. Risk of severe burns to hands and arms. Before carrying out installation and maintenance work make sure that the equipment is cold. Attention The name plate specifies the technical features of the equipment. Do not commission or operate any item of equipment that does not bear its specific name plate. 4

Directives and standards VdTÜV Bulletin Wasserstand 100 (= Water Level 100) The level electrode NRG 10-52 / NRG 16-52 in conjunction with the following level switches is type approved according to VdTÜV Bulletin Wasserstand 100 : NRS 1-52, NRS 1-53, NRS 1-54 and NRS 1-55 or NRS 1-1, NRS 1-2, NRS 1-3 and NRS 1-5. The VdTÜV Bulletin Wasserstand (= Water Level) 100 specifies the requirements made on water level control and limiting equipment for boilers. ATEX (Atmosphère Explosible) The level electrodes NRG 10-52 and NRG 16-52 are simple items of electrical equipment as specified in EN 60079-11 section 5.7. According to the European Directive 2014/34/EU the equipment must be equipped with approved Zener barriers if used in potentially explosive areas. Applicable in Ex zones 1, 2 (1999/92/EG). The equipment does not bear an Ex marking. Note on the Declaration of Conformity / Declaration by the Manufacturer For details on the conformity of our equipment according to the European Directives see our Declaration of Conformity or our Declaration of Manufacturer. The current Declaration of Conformity / Declaration of Manufacturer are available in the Internet under www.gestra.com/documents or can be requested from us. 5

Technical data NRG 10-52, NRG 16-52 Operating pressure NRG 10-52: PN 6, 6 bar at 164 C NRG 16-52: PN 40, 32 bar at 238 C Mechanical connection Screwed G 1 A, ISO 228 Materials Screw-in body 1.4571, X6CrNiMoTi17-12-2 Electrode tips 1.4571, X6CrNiMoTi17-12-2 Insulation, spacer disks PTFE Five-pole connector 3.2161 G AlSi8Cu3 Lengths available 1000 mm, 1500 mm Electrical connection Five-pole connectors, cable glands Pg 11 Protection IP 65 to EN 60529 Max. admissible ambient temperature Max. 70 C Weight Approx. 1.6 kg (NRG 16-52 L =1000 mm) Approvals: TÜV certificate Scope of supply VdTÜV Bulletin Water Level 100 Requirements made on water level limiting & control equipment. Type approval no. TÜV. WR / WB. XX-302; XX-424 (see name plate) NRG 10-52 1 Level electrode NRG 10-52, PN 6 1 Joint ring 33 x 39 form D to DIN 7603, made from 1.4301, bright annealed 1 Installation manual NRG 16-52 1 Level electrode NRG 16-52, PN 40 1 Joint ring 33 x 39 form D to DIN 7603, made from 1.4301, bright annealed 1 Installation manual Name plate/marking Equipment designation Safety note NRG 16-52 PN 40 G 1 1.4571 IP 65 TÜV. WR / WB. xx-424 Pmax Tmax 32 bar (464psi) 238 C (460 F) T amb = 70 C (158 F) Mat-Nr.: Betriebsanleitung beachten See installation instructions Voir instructions de montage GESTRA AG Münchener Straße 77 D-28215 Bremen Manufacturer Fig. 1 Application range Pressure rating, thread type, material number Disposal note Type approval no. CE Marking 6

Installation Note One level electrode NRG 10-52 / NRG 16-52 can be installed together with one GESTRA level electrode, one compact level switch or transmitter in a single protection tube or external level pot (inside diameter 100 m). Fig. 4-7. If the level limiting electrode is installed inside the vessel, it must be at least 40 mm away from the upper vent hole. For the approval of the boiler standpipe the relevant regulations must be considered. Refer to pages 10 for typical installation examples. If installed outdoors the level electrode must be equipped with a GESTRA weather protection cover. Attention The level electrode shall be installed vertically. The seating surfaces of the standpipe or the flange provided on the vessel must be accurately machined, see Fig. 3. Do not bend electrode tips when mounting. Do not subject electrode tips to physical shocks. At least 30 mm of the insulating tube must remain on the electrode tips. Use only the supplied joint ring. NRG 1.-52: 33 x 39, form D, DIN 7603, 1.4301, bright annealed Do not lag electrode body above the hexagonal section. Do not insulate electrode thread with hemp or PTFE tape! Do not apply conductive paste or grease to the electrode thread! Make sure that the air distance between the electrode tips and earth (flange, vessel wall) is not less than 14 mm. Fig. 4-7. Observe the minimum withdrawal distance when installing the electrode! The specified torques must be strictly observed. Tools Open-end spanner A. F. 41, DIN 3110, ISO 3318 Scriber Bolt cutter Flat file, medium cut, DIN 7261, form A 7

Installation - continued - Dimensions NRG 10-52, NRG 16-52 3 40 260 1 42 2 A 1 2 3 4 Screwed G 1 A, ISO 228 C 4 1000, 1500 5 50 14 65-70 G1, ISO 228-1 N10 0.5 N8 Fig. 2 NRG 1..-52 with five-pole connector Fig. 3 8

Installation - continued - NRG 10-52, NRG 16-52, step 1 1. Determine required measuring lengths of electrode tips and enter data in table Functions. 2. Use a bolt cutter to cut the four electrode tips 1234. 2. Deburr faces of electrode tips. 3. Strip off 50 mm of PTFE insulation from the ends of the electrode tips. Make sure that the remaining insulation is at least 30 mm long, measured from the lower edge of the screwed connection. NRG 10-52, NRG 16-52, step 2 7. Check seating surfaces. Fig. 3 8. Place supplied joint ring 2 onto seating surface of the threaded standpipe or flange. Fig. 3 9. Apply a light smear of heat resistant silicone grease (e.g. WINIX 2150) to electrode thread 3. 10. Screw level electrode into threaded standpipe or flange and tighten with an open-end spanner A. F. 41 mm. The torque required when cold is 140 Nm. Table Functions Function Function Please enter function! Electrode body Functional earth e. g. MIN alarm 1 e. g. pump OFF 2 e. g. pump ON 3 e. g. MAX alarm 4 Electrode rod/ Connecting terminal Length [mm] Please enter length Key 1 Thermal insulation, provided on site, d = 20 mm (outside of thermal insulation of steam boiler) 2 NRG 1..-52: Joint ring 33 x 39, form D, DIN 7603, 1.4301, bright annealed 3 Electrode thread 4 Insulation of electrode tips 5 Electrode tips 9

Examples of installation NRG 10-52, NRG 16-52 1" DN 50 6 7 1" DN 50 6 72 Fig. 4 Fig. 6 d 8 c 9 90 20 Protection tube (provided on site) for installation inside the boiler 20 20 G ¾ DN 100 24,524,5 4 20 20 1" 14 8 0 a e f 1500 6 7 0 a c 9 e g 90 20 Protection tube (provided on site) for installation inside the boiler and in combination with other GESTRA equipment Fig. 5 DN 20 DN 20 1500 Centre distance 9 10 90 20 Protection tube (provided on site) for installation inside the boiler 1" 20 20 20 20 8 0 a e f 6 9 h 0 e Fig. 7 External level pot DN 20 10

Examples of installation - continued - Key 6 Flange PN 40, DN 50, DIN EN 1092-01 (single electrode) Flange PN 40, DN 100, DIN EN 1092-01 (combination of electrodes) 7 For the approval of the boiler standpipe with connecting flange the relevant regulations must be considered. 8 Vent hole Provide vent hole as close to the boiler wall as possible! 9 High water (HW) 0 Electrode tip d = 5 mm a Protection tube DN 80 (in France according to AFAQ DN 100) b Protection tube DN 100 c Distance between electrode rods and protection tube 14 mm d Distance between electrode tips (NRG 1..-50 or NRG 1...-51) 14 mm (creepage distances and clearances) e Low water LW f Reducer DIN 2616-2, K-88.9x3.2-42.4 x 2.6 W f Reducer DIN 2616-2, K-114.3x3.6-48.3 x 2.9 W h Level pot DN 80 11

Electrical connection NRG 10-52, NRG 16-52 with five-pole connector j k l m n o i p q r s Fig. 9 Key i Level electrode NRG 10-52, NRG 16-52 j Retaining bracket k Lower part of terminal box l Contact block m Screw n Sealing ring o Upper part of terminal box p Gasket q Ring r Cable gland s Control cable Tools Screwdriver, size 1 Screwdriver, size 2.5, completely insulated according to DIN VDE 0680-1 12

Electrical connection - continued - Connection of level electrode To connect the level electrode use screened multi-core control cable with a min. conductor size 0.5 mm 2, e. g. LiYCY 5 x 0.5 mm 2, max. length: 100 m. Connect the screen only once to the central earthing point (CEP) in the control cabinet. NRG 10-52, NRG 16-52 - connecting the five-pole connector 1. Swing up the retaining bracket j and detach the upper part of the terminal box o from the level electrode. 2. Undo screw m and press the contact block l out of the upper part of the terminal box o. Make sure that you do not lose the sealing ring n. 3. Unscrew cable gland r. 4. Pull cable through cable gland r, ring q, gasket p and upper part of terminal box o. 5. Connect the terminals in the contact block l (Fig. 10) according to table Functions on page 9. 6. Press the contact block l into the upper part of the terminal box o. 7. Insert screw m (with sealing ring n) into hole and tighten. In doing so the contact block l is fixed to the upper part of the terminal box o. 8. Fasten the cable gland r. 9. Plug the upper part o into the lower part k of the terminal box and secure it in place by swinging down the retaining bracket j. Connecting terminals in contact block Fig. 10 4 3 1 2 Attention n Please observe the instructions given in the installation & operating manual for the NRS 1-52, NRS 1-53, NRS 1-54 and NRS 1-55 or NRS 1-1, NRS 1-2, NRS 1-3 and NRS 1-5. n Make sure that connecting cables leading to the level electrode are segregated and run separately from power cables. n Check the connection of the screen to the central earthing point (CEP) in the control cabinet. 13

Commissioning, fault indication and troubleshooting For additional information on commissioning procedures and troubleshooting refer to the installation & operating manuals for level switch NRS 1-52, NRS 1-53, NRS 1-54 and NRS 1-55 or NRS 1-1, NRS 1-2, NRS 1-3 and NRS 1-5! Removing and disposing of the level electrode Danger When loosening the electrode steam or hot water might escape! This presents the risk of severe scalding all over the body! It is therefore essential not to dismantle the electrode unless the boiler pressure is verified to be 0 bar. The electrode becomes hot during operation. Risk of severe burns to hands and arms. Before carrying out installation and maintenance work make sure that the equipment is cold. Removing and disposing of level electrode NRG 10-52 / NRG 16-52 1. Undo screw m. Fig. 9 2. Detach upper part of the terminal box o from the level electrode. 3. Before removing the equipment make sure that is is neither hot nor under pressure. For the disposal of the equipment observe the pertinent legal regulations concerning waste disposal. If faults occur that are not listed above or cannot be corrected, please contact our service centre or authorized agency in your country. 14

For your Notes 15

Agencies all over the world: www.gestra.de GESTRA AG Münchener Straße 77 28215 Bremen Germany Telefon +49 421 3503-0 Telefax +49 421 3503-393 E-mail info@de.gestra.com Web www.gestra.de 819123-02/03-2017cm (808842-02) GESTRA AG Bremen Printed in Germany