INSTALLATION AND OPERATION INSTRUCTIONS 303, 304, 305, CRH, CRQ, CFA SERIES 2250 WATT MODELS

Similar documents
R Series B & T2 Model

K Series (Model A) Fan Forced Wall Heaters

961 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting

5700 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting

Installation & Maintenance Instructions

COM-PAK COM-PAK TWIN. Com-Pak/Com-Pak Twin Heater. Owner s Guide. tested to UL standards PERFECTLY SIMPLE WARMTH FOR ANY ROOM

3480/RCH SERIES INSTALLATION INSTRUCTIONS

Installation & Maintenance Instructions

FLCH4R Garage and Utility Electric Heater

IMPORTANT INSTRUCTIONS READ & SAVE

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

IMPORTANT INSTRUCTIONS READ & SAVE

RA889A Switching Relay

IMPORTANT SAFETY INFORMATION

Install Guide Customer Support: or Visit our website

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

IMPORTANT INSTRUCTIONS

Installation Instructions and Homeowner's Manual

IMPORTANT INSTRUCTIONS READ & SAVE

WM-4510HZD Installation Instructions

IMPORTANT INSTRUCTIONS READ & SAVE

Com-Pak Heater Benefits You Can Depend On Com-Pak Models Line Model w/o Model w/ Voltage Thermostat Thermostat Watts Amps (1) (2)

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

HI Industrial Utility Heater HI Soleus Air International

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

IMPORTANT INSTRUCTIONS READ & SAVE

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

... a. Electric Baseboard Heaters IN THIS SECTION J b t S. SY-STEl\t1S, I~C_

Electric Space Heater

Thanks for shopping with Improvements! Springfield Compact Electric Fireplace Item #470279

EF5528RKD Freestanding Electric Fireplace

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

Hardwired Electric Garage Heater

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

Electric Garage Heater

Installation & Maintenance Instructions

M650-38A-OAK ELECTRIC FIREPLACE HEATER NDF-65NB-1 INSTRUCTION MANUAL

Suntec. Infrared HomeHeating System. Model. Thermal Design

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Hardwired Electric Garage Heater

HD3D Forced-Air Heater

Cedarbrook Sauna + Steam Family owned and operated since 1971

MP BB. ElEcTrIc FIrEplAcE HEATEr. INSTrUcTION MANUAl ATTENTION:

CEILING FAN OWNER'S MANUAL

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

EF5802R Freestanding Electric Fireplace

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

IMPORTANT SAFETY INFORMATION:

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Installation Instructions and Homeowner's Manual

#ADENCE4- $ESIGNED )NCLUDES #OOL4OUCH4- +ICHLER )NSTRUCTION #USTOMER KHA

ENERVEX ADC100 DRAFT CONTROL

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

QCM979D-38AGO ELECTRIC FIREPLACE HEATER NDF-65NB-3 INSTRUCTION MANUAL

Installation Instructions

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

ASSEMBLY AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

e Heater/Exhaust Fan/Light User s Guide

WAIWELA SERIES-TWO WATER HEATERS

Type STAR Radiant Heater For Portable Installations

RA889A Switching Relay

ARWH Series Smart Series Architectural Wall Heater

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

E Z S E R I E S " W X 16" H

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Ducoterra Radiant Heating Panel Installation Manual

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Ceiling Fan Installation Instructions

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

nordica 36 ceiling fan

Installation and Operating Manual

INSTALLATION INSTRUCTIONS

Transcription:

INSTALLATION AND OPERATION INSTRUTIONS 303, 304, 305, RH, RQ, FA SERIES 2250 WATT MODELS aution: To prevent electric shock disconnect power to heater at main service before wiring or service. aution: Do not obstruct the front of the heater with curtains, furniture, doors, etc. Do not place heaters under towel racks. Proper operation of the heater requires a free flow intake and exhaust of air. WARNING: To insure proper operation, all heaters must be thermostatically controlled. GENERAL These heaters are designed for 2 X 4 recessed or surface mount installation. The heaters may be wall mounted in a vertical position with bottom discharge, or horizontal position and ceiling mounted. The minimum clearance from wall box to adjacent wall or floor is 6 inches. These heaters must not be installed without wall box model no. 30WB. INSTALLATION OF WALL BOX 30 WB FOR NEW ONSTRUTION 1. Position wall box a minimum of 6 inches from adjacent wall and floor. Secure to wall stud with nails or screws. Wall box must be installed with front edge flush with finished wall surface. See figure 1. 2. Remove knockout in wall box for power source, and install cable clamp. 3. Insert supply cable through clamp allowing 6-8 for field wiring. NOTE: Field wiring must enter wall box where the corner wiring compartment is located. Page 1 Form 9956 Rev 01/06

INSTALLATION OF WALL BOX 30WB FOR EXISTING ONSTRUTION 1. arefully cut a hole measuring 9 1/4 wide by 12 1/4 long in wall. Wall box 30WB must be attached to a wall stud on one edge. Minimum clearances of 6 must be maintained to adjacent surfaces. Attach wall box and secure power cable as in new construction. FIG. 1 NOTE: IN THE VERTIAL POSITION THE HEATER AN BE MOUNTED ONLY FOR BOTTOM DISHARGE. FIELD ONVERSION FOR LOWER WATTAGE To convert heater to a lower wattage rating, see Fig. 2. INSTALLATION OF HEATER ASSEMBLY 1. Place heater into wall box and secure with the two no. 8 X 1/2 screws provided. 2. onnect power supply to heater pigtails with wire nuts or crimp terminals. 3. After field connections are made, push wires into wiring compartment and secure wiring compartment cover to heater using no. 8 X 1/2 screw provided. INSTALLATION OF GRILLE AND KNOB 1. Place the two no. 8 oval head screws into grille mounting holes. 2. Align grille with heater and secure. Be careful not to over tighten as this may cause fan blade to strike grille. 3. To install knob, remove hole plug in grille and align flat of thermostat shaft with flat on knob. Push knob onto shaft until knob almost touches grille. 4. For tamper-resistant installation, set thermostat with knob, remove knob and replace hole plug. Retain knob for future use. Page 2 FORM 9956 Rev. 01/06

OPERATION 1. Turn on the power supply to heater. 2. Rotate thermostat knob fully clockwise. This heater is equipped with a fan delay, so the fan will be delayed 45-60 seconds after the element is energized. 3. Allow the room to reach desired temperature, then rotate thermostat knob counter clockwise until thermostat clicks. Fan will continue to run for 45-60 seconds to purge warm air from heater enclosure. The heater will continue to cycle on and off in the selected temperature range. 4. For remote thermostat operation, remove wire nut on wires marked T1 and T2. onnect single pole remote thermostat to T1 and T2. Thermostat wiring must be the same size as power supply wiring. See specification chart for minimum wire size. NOTE: The wall thermostat cycles the heating element only. Direct runs of supply service leads L1 and L2 supplies continuous power to the fan motor, and the heater should be considered live at all times. Move the disconnect switch to the off position or disconnect power at main distribution box before any maintenance work. Turning the thermostat to low position will not disconnect the heater. WARNING: It should be noted that the 3000 series units feature a fan delay control to allow for element pre-heat and more critically fan purge of heat at the end of thermostat cycle. If the units are turned off with disconnect while the motor is operating, the residual heat may allow the manual reset thermal limit to cycle, this may lead to service calls and unnecessary returns of the units. To turn these units off with the disconnect switch, the thermostat should first be turned to low position, fan should be allowed to complete the purge cycle. These units have a label attached that states DO NOT DISONNET UNIT WHILE IS RUNNING. This applies to any unit that has the disconnect option. NOTE: This heater is equipped with a manual reset limit control. The front grille must be removed to reset limit. Disconnect power before reset button is pushed. SPEIFIATIONS MODEL NO. VOLTS WATTAGE * F30322, RH822 F30422, PQ822 F30522, FA822 H30322, RH222 H30422, PQ222 H30522, FA222 208 240 500, 750, 1000 1250, 1500, 1750 2250 500, 750, 1000 1250, 1500, 1750 2250 BTU/ HOUR 1707, 2560, 3413, 4266, 5120, 5973 7680 1707, 2560, 3413, 4266, 5120, 5973 7680 AMPERAGE MIN. ** WIRE SIZE 60 10.8 14 AWG. 9.4 14 AWG. * Factory wired for higher wattage, field convertible to lower wattage. ** Use copper wire only. All wiring must conform to N.E.. and local electric codes. Page 3 FORM 9956 Rev. 01/06

FIG. 2 WATTAGE ONVERSION HART WD-1 2250W WD-2 1750W Remove orange jumper. WD-3 1500W Remove red jumper and move orange jumper to terminal "A". WD-4 1250W Remove red jumper, remove wires from terminal "A" to terminal "B". onnect orange jumper to terminals "B" and"". WD-5 1000W Remove orange and red jumpers. WD-6 750W Remove orange and red jumpers. Move wires from terminal "A" to "B". WD-7 500W Remove orange and red jumpers. Move wires from terminal "A" to "'. WD-2 1750W WD-3 1500W WD-4 1250W WD-5 1000W WD-6 750W WD-7 500W Form 9956 Rev. 01/06 Page 4

"T" OPTION "T2" OPTION ONTROL ONTROL "TD" OPTION "T2D" OPTION L1 L2 (N 120-277) L1 L2 (N 120-277) DISONNET SWITH DISONNET SWITH ONTROL ONTROL Page 5 FORM 9956 Rev. 01/06