u JOSSI FIRE SHIELD U JOSSI METAL SHIELD U JOSSI COMBO SHIELD Technical Data

Similar documents
Easy Series Voice Modules

Certificate of constancy of performance,

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

Certificate of constancy of performance,

PRODUCTSHEET Plasmamade AirFilter GUC1212

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

ICP-EZM2. ICP-EZM2 Release Notes F01U Page Bosch Security Systems, Inc.

VACUUM FOR HIGHER QUALITY. In plastic injection molding

VACUUM FOR HIGHER QUALITY. In plastic injection molding

Digital Control Systems & Remote Communications Options

The Global Leader for Safety Signs & Labels COLLABORATION IN A NEW ERA OF VISUAL SAFETY

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Options for Diesel Fire Pump Controllers

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

SIRe Control system. Intelligent Automatically adapts to your entrance. Proactive Anticipates for quicker reactions. Adaptive Expert on your entrance

This document is a preview generated by EVS

This document is a preview generated by EVS

VACUUM FOR HIGHER QUALITY. In pressure die casting

INVERTER DUCTED SYSTEMS

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Synova TM product catalog.

Technical Data Submittal Documents

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

ARGUS Smoke Detectors. The next generation. Safety and security electronics

MODEL: LS-2720/LS-2129/LS-2150 LS-2125/LS-2125i/LS-2160 SL-7/JS-23 VX-1435 X-5 LS-3000 LS-5000 LX3014

PAVIRO EN 54 devices supported by IRIS-Net

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Installation Operation Maintenance

AIR PROCESSING UNITS APPLICATION GUIDELINE

Getinge 8666/8668 Washer Disinfectors

X-dock Software History

QAW70. Room Unit. Building Technologies. for use with heating controllers

Ilshin Spinning Co Ltd. Ilshin Spinning Co Ltd. State-of the-art ring spinning mill in Korea

Air Conditioners Heating & Cooling

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

DPM4 Bedside Monitor Default Settings

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

STERILIZER STEAM - GLOBO 6412 INNOVATING TRADITION

Technical Data Submittal Document

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

BM Programming Module. For the heating engineer Installation instructions

Options Guide. Sintesis air-cooled scroll chillers Models CGAF kw

High Performance Air to Water Heat Pump

Welcome to Leviton Security & Automation

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications

ASM 340. Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

Air Conditioners Heating & Cooling

Easy Series Intrusion Control Panel

Air Conditioners Heating & Cooling

COMFORT IP: Room Control Unit Radio with Display

Air Conditioners Heating & Cooling

Sinteso TM product catalog.

TYPICAL KITCHEN EXTRACT SOLUTION

Aspirating Accessories: Pipes and Fittings

MAKRO. Tokotype Revisied in Gumpita Rahayu. 8 Styles Available For Desktop, Web, and App V.2.0. Makro PDF Specimen. Released.

SONOCHEK The ultrasonic testing device

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

DVANTAGE A RITMO RITMO WORLDWIDE

Prevention of Fires and Dust Explosions within the Biomass Handling Process. PFI July 20, 2015

Electronic eyelet button holer RH-9820

USTER INTELLIGIN-M APPLICATION REPORT. Monitoring of the ginning process THE GIN PROCESS CONTROL SYSTEM

CleanSeaNet First Generation. 16 April January 2011

Installation Operation Maintenance

Air Conditioners Heating & Cooling

PowerWizard Range. Digital Control Systems & Remote Communication Options.

Easy Series Intrusion Control Panel

Low air consumption vacuum generators

Heating Controller. Synco 700

Air Conditioners Heating & Cooling

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

TopMaster Air Handling unit. Technical data

HE-03 Advanced Honey Extractor Controller

Productivity and sewing quality are combined at the highest level ever.

Rosemount 8800D Series Vortex Flowmeter

Assembly and operating instructions Ice detector EM for open spaces and gutter heating

Heating Controller SDC Remote Heating Controller DHC

Seminar on Standardisation in Research and Innovation Practical tools for the dissemination and implementation of research results

Air product news. Mid year Refrigeration

Protecting Critical Facilities Against Explosions

PolyGard 2-channel Gas Controller MGC-03

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software


Installation and User Guide living connect Electronic Radiator Thermostat

ecotec plus boiler user guide

DeDusting Solutions for the plastics industry

This unique feature seamlessly integrates security into your everyday life to give you safe, simple living with peace of mind.


: WHOM IT MAY CONCERN DATE : REFERENCE : LP.POS.0034 COMPLETE OPEN END PLANT

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

M700-Series Multifunction OTDR

Air Conditioners Heating & Cooling

Laboratory refrigerators

PARTS LIST. CoverPro 900CP & 1000CP

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

Quick start guide. BiPAP AVAPS

Transcription:

u JOSSI FIRE SHIELD U JOSSI METAL SHIELD U JOSSI COMBO SHIELD Technical Data February 2018

USTER JOSSI FIRE SHIELD Scope of delivery USTER JOSSI FIRE SHIELD Basic equipment and parts Documentation Accessories The USTER JOSSI FIRE SHIELD will be delivered in a preassembled stage. The unit can be installed by the customer. The service engineer will do the final commissioning as well as the final set-up directly at the spinning mill/blowroom. Detection duct with spark sensors High Speed Diverter Collector bin Control unit Alarm unit (Hooter) Optional extinguisher system Connection cones for needed duct diameter The following documents will be supplied on delivery: Brief instruction Operating instructions of the USTER JOSSI FIRE SHIELD Spare parts catalogue included in the operating instruction Unit key available, this key opens the collector bin Technical Data 2

USTER JOSSI FIRE SHIELD Specification USTER JOSSI FIRE SHIELD General Functions USTER JOSSI FIRE SHIELD is designed to detect and eject sparks in pneumatic conveying lines of spinning mills. An optional extinguisher is available to protect the system itself. Control unit Control unit of USTER JOSSI FIRE SHIELD, equipped with buttons and LEDs Detection production rate Spark detection system up to 1 200 kg/hour (depending on working diameter) Operating temperature 5 to 50 C Working diameters Ø 220 (diverter small) Ø 300/Ø 350/Ø 400 (diverter large) Power consumption 30 VA Weight App. 75 kg (small), 135 kg (large) Material flow Horizontal Installation In pneumatic conveying lines for the transport of tufted or fibrous material Operating languages on USTER JOSSI FIRE SHIELD Language English Technical Data 3

USTER JOSSI FIRE SHIELD Features USTER JOSSI FIRE SHIELD Key actions Avoidance of false alarms SPARX avoids false alarms due to electrostatic discharge in case of cotton and MMF blends Sensitivity, threshold Defined sensitivity, no adaptation through the operator needed High speed diverter Driven by a high-performance pneumatic drive with a reaction time of 60 ms 6 bar pressure for compressed-air recommended Maintenance Easy access to the screens in the collector bin Easy access to the detection duct Connections to the blowroom control Stop fan Ready/Trouble Fire alarm, stop machine Contact load 250 VAC/2 A Technical Data 4

7,539 2250 1214 1568 D out D in 600 970 Ø220 Ø220 USTER JOSSI FIRE SHIELD Technical drawing of USTER JOSSI FIRE SHIELD Diverter small: 2850 250 HP 300 650 300 1250 350 optional Diverter large: 370 HP L 450 650 450 1250 350 optional Ø716 Piping (D in/d out ) [mm] Ø 300 Ø 350 Ø 400 L [mm] 3150 2 800 3150 Technical Data 5

USTER JOSSI METAL SHIELD Scope of delivery USTER JOSSI METAL SHIELD Basic equipment and parts Documentation Accessories The USTER JOSSI METAL SHIELD will be delivered in a preassembled stage. The unit can be installed by the customer. The service engineer will do the final commissioning as well as the final set-up directly at the spinning mill/blowroom. Metal sensor High Speed Diverter Collector bin (short or long) with attached control unit and alarm light Floor supports Connection cones for needed duct diameter The following documents will be supplied by the delivery: Brief instruction Operating instructions of the USTER JOSSI METAL SHIELD Spare parts catalogue of the USTER JOSSI METAL SHIELD Unit key available, this key opens the collector bin Testing rod for metal sensor Technical Data 6

USTER JOSSI METAL SHIELD Specification USTER JOSSI METAL SHIELD General Functions USTER JOSSI METAL SHIELD is designed to detect and eject metal particles in pneumatic conveying lines of spinning mills. Speed sense, much less of the transported material is ejected thanks to sensitive recognition of speed and size of the detected metal particle. Small and fast particles: shorter activation, larger and rather slow particles: longer activation. Display Detection production rate Operating temperature At USTER JOSSI METAL SHIELD front panel of the control unit Metal detection system up to 1 200 kg/hour (depending on working diameter) 5 to 50 C Working diameters Power consumption Weight Material flow Installation Ø 220/Ø 300 Ø 350/Ø 400 50 VA App. 175 kg (short), 235 kg (long) Horizontal In pneumatic conveying lines for the transport of tufted or fibrous material Operating languages on USTER JOSSI METAL SHIELD 21 languages German, English, Chinese, Turkish, Italian, Spanish, French, Polish, Portuguese, Czech, Korean, Russian, Taiwanese, Portuguese, Greek, Croatian, Hungarian, Dutch, Norwegian, Romanian, Swedish Technical Data 7

USTER JOSSI METAL SHIELD Features USTER JOSSI METAL SHIELD Key actions Adaption of ejection time Cotton saving through automatic adaption of ejection time Ejection time is automatically calculated by the system, based on speed and size of the metal particle Sensitivity, threshold Easy adaptation of the sensitivity through the operator High speed diverter Driven by a high-performance pneumatic drive with a reaction time of 60 ms 6 bar pressure for compressed-air recommended Maintenance Easy access to the tuft screen of the collector bin Connections to the blowroom control Ready/Trouble Contact load 250 VAC/3 A Technical Data 8

1567 3400-4500 3350 2322 2676 D out D in USTER JOSSI METAL SHIELD Technical drawing of USTER JOSSI METAL SHIELD Long version L 450 650 750 1400 350 Ø716 Short version 1213 out 2300-3400 2250 D D in L 450 650 750 1400 350 Ø716 Piping (D in/d out ) [mm] Ø 220 Ø 300 Ø 350 Ø 400 L [mm] 3 600 3 600 3 250 3 600 Technical Data 9

USTER JOSSI COMBO SHIELD Scope of delivery USTER JOSSI COMBO SHIELD Basic equipment and parts Documentation Accessories The USTER JOSSI COMBO SHIELD will be delivered in a preassembled stage. The unit can be installed by the customer. The service engineer will do the final commissioning as well as the final set-up directly at the spinning mill/blowroom. Detection sensors for sparks and metal High Speed Diverter Collector bin (short or long) with attached control unit and combined alarm light and hooter Floor supports Connection cones for needed duct diameter The following documents will be supplied by the delivery: Brief instruction Operating instructions of the USTER JOSSI COMBO SHIELD Spare parts catalogue of the USTER JOSSI COMBO SHIELD Unit key available, this key opens the collector bin Testing rod for metal sensor Technical Data 10

USTER JOSSI COMBO SHIELD Specification USTER JOSSI COMBO SHIELD General Functions USTER JOSSI COMBO SHIELD is designed to detect and eject sparks and metal particles in pneumatic conveying lines of spinning mills. Speed sense, much less of the transported material is ejected thanks to sensitive recognition of the size and speed of the detected metal particle. Small and fast particles: shorter activation. Larger and rather slow particles: longer activation. Display Detection production rate Operating temperature At USTER JOSSI COMBO SHIELD front panel of the control unit Spark detection system Metal detection system Up to 1 200 kg/hour (depending on working diameter) 5 to 50 C Working diameters Ø 220/Ø 300 Ø 350/Ø 400 Power consumption Weight Material flow Installation 60 VA App. 185 kg (short), 245 kg (long) Horizontal In pneumatic conveying lines for the transport of tufted or fibrous material Operating languages on USTER JOSSI COMBO SHIELD 21 languages German, English, Chinese, Turkish, Italian, Spanish, French, Polish, Portuguese, Czech, Korean, Russian, Taiwanese, Portuguese, Greek, Croatian, Hungarian, Dutch, Norwegian, Romanian, Swedish Technical Data 11

USTER JOSSI COMBO SHIELD Features USTER JOSSI COMBO SHIELD Key actions Avoidance of false alarms SPARX avoids false alarms due to electrostatic discharge in case of cotton and MMF blends Adaption of ejection time Cotton saving through automatic adaption of ejection time Ejection time is automatically calculated by the system, based on speed and size of the metal particle Sensitivity, threshold Easy adaptation of the sensitivity through the operator High speed diverter Driven by a high-performance pneumatic drive with a reaction time of 60 ms 6 bar pressure for compressed-air recommended Maintenance Easy access to the spark detection Easy access to the screens in the collector bin Connections to the blowroom control Stop fan Ready/Trouble Fire Alarm, stop machine Contact load 250 VAC/3 A Technical Data 12

2300-3400 2250 1214 1568 D out D in 3400-4500 3350 2322 2676 D D out in USTER JOSSI COMBO SHIELD Technical drawing of USTER JOSSI COMBO SHIELD Long version L 450 650 750 1400 300 350 Ø716 Short version L 450 650 750 1400 300 350 Ø716 Piping (D in D out ) [mm] Ø 220 Ø 300 Ø 350 Ø 400 L [mm] 3 900 3 900 3 550 3 900 Technical Data 13

Uster Technologies has made all possible efforts to ensure that all information is accurate at the time of publication. Hereby it is declared that alterations to the product may be possible at any time. In these cases the information contained in this technical datasheet is subject to change without notice. February 2018 02.18/ Copyright 2018 by Uster Technologies AG USTER Switzerland Knoxville, USA Charlotte, USA Adana, Turkey Suzhou, China Osaka, Japan Shanghai, China Coimbatore, India São Paulo, Brazil Uster Technologies AG Sonnenbergstrasse 10 8610 Uster Switzerland T. + 41 43 366 36 36 F. + 41 43 366 36 37 sales@uster.com www.uster.com