MINERVA MZX125. Digital Addressable Fire Detection System

Similar documents
MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MX. 800 Series Ancillary Equipment

Addressable Loop Powered Visual Alarm Devices

AU MX Digital Loop Card Installation Instructions

System 800 Addressable Fire Detection & Alarm System

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

850 Series Fire Detectors - Generation 6

Evolution Analogue Addressable Fire System

850 and 830 Series. Fire Detectors - Generation 6

850 and 830 Series. Generation 6

830 Series. Fire Detectors - Generation 6

850 and 830 Series. Generation 6

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

830 Series Fire Detectors

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Sita200plus. 200detectors. Single loop analogue addressable System

ZETTLER Product Catalogue

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Consultant Specification AGILE Wireless Fire Detection System

Touch Screen 1 loop Addressable Fire Alarm Panel

EFBW series - BiWire Ultra control panel

Opal TM AV Devices. Data Sheet. Benefits

Intelligent addressable fire alarm control panel

The new detector from Rafiki

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Intellia Sounder Bases and Sounder Beacon Bases

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Opal TM AV Devices. Data Sheet. Benefits

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Analogue addressable devices

Conventional Fire Detection

Fire Signalling. Signalling Solutions

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Industries. As a premier global manufacturing company, we believe that great brands are

Addressable Loop Modules

Multi-Point Peripherals

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Fire Product Catalog

Cerberus FIT conventional system

Wireless Fire & Security Solutions. Fire Product Showcase

INTELLIGENT FIRE TECHNOLOGY

Excel-EN Conventional Fire Control Panel

intelligent solutions

HART XL High Sensitivity Smoke Detection

Intelligent Security & Fire Ltd

Emergi-Lite Orbis detectors

IQ8Control C Fire Alarm Panel

Solution F2. Fire Alarm Control Panels one step ahead.

Addressable and Conventional Fire Protection

LEAKSTOPPER RANGE Multizone water leak detection systems

The complete conventional fire warning system

The EN54 Part 2 and 4 Fire System

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

HART XL High Sensitivity Smoke Detection

The ZETTLER Generation 6 Detector Range

Fire Detection - Addressable

TrueAlarm ES Analog Sensing

SOUNDER BASES AND SOUNDER BEACON BASES

CONTENTS. Contents. Chapter 1 - Introduction 1.1. Chapter 8 - Fire Phones & Disable Refuge 8.1

Multi-Point Peripherals

Fire and Smoke Control Systems

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

CONVENTIONAL AUDIBLE VISUAL

Addressable Fire Alarm Devices Superior Technology for the Highest Protection

Touchpoint Plus. A whole new control experience

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

XP95 Sounder VAD Base

Apollo Accreditation. Need further information? Visit

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Xenex Conventional Fire Detection & Alarm System

Addressable Detectors & Bases

Certificate of Conformity Certificate num. Registration date Version Valid until

ZXSe Range Data Sheet

An introduction to... Sigma

DS7400Xi Addressable Control/ Communicator

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

OH720, OP720, HI720, HI722

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Interface Modules for SENTRI

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

/ / White Paper. Focusing on user experience

System 57. An advanced World of intelligent gas detection system management

Reliably Advanced Extinguishing Control

ZETTLER Product Catalogue

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

Fire Systems Design Pocket Guide BS 5839 Part 1:2017 and CoP 0001 for Visual Alarm Devices. Fire Installers Mate. A guide to fire system design

FireClass. Introducing a new class of fire detection

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Evacuate everyone Sonos Pulse & Nexus Pulse

IGD.CO.UK

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Reliably Advanced Extinguishing Control

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

Transcription:

A C C E S S C O N T R O L C C T V E A S R F I D F I R E P R O T E C T I O N I N T R U D E R A L A R M S DATA SHEET MINERVA MZX125 Digital Addressable Fire Detection System Features: Long term service and support Supports 1 MXDigital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with Front Panel Controls to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 16 Zone Fully Functional Mains powered Repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839 Easy programming when using MXConsys Express configuration tool. The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system provides a single loop of 125 addresses making it suitable for small to medium size premises. A matching 16 zone fully functional repeater is available, A maximum of 7 repeaters can be driven from the control panels 2 wire remote bus, the repeater houses its own mains psu and batteries. The MXDigital protocol is robust enough to operate over most cable types making it an ideal choice for upgrades where existing cables can be reused to dramatically cut costs. The built in power supply will charge the internal batteries and support a full compliment of loop powered sounders and beacons in accordance with the requirements of BS5839. The Minerva MZX125 is a fire detection controller at the heart of a comprehensive fire detection system that can be used to protect both life and property. A Tyco International Company

3oTec There is an obligation to comply with legislation such as the Regulatory Reform (Fire Safety) Order or the Fire (Scotland) Bill to ensure the safety of occupants. Similarly the avoidance of disruptive false alarms from the fire detection system is paramount. 3oTec is a triple sensing detector that uses advanced algorithms to intelligently analyse the level of smoke, heat and carbon monoxide. The result is, fires are detected much earlier and false alarms can be eliminated. Disability Discrimination Act With Minerva MZX125, compliance with the DDA is uncomplicated and does not require the use of special, high cost detection units. In place of the standard detector base, Minerva MZX125 uses an AVbase that produces a high intensity beacon of light in addition to the audio signal. No additional wiring is required. The full standard range of MX detectors can be used with the AVBase including 3oTec and flame detection. The result is DDA compliance with flexibility of design and lower lifetime cost. In situations where ceiling mounted beacons would be ineffective in complying with the DDA, wall mounted loop powered beacons and sounder beacons can be incorporated. To ensure that a DDA compliant system remains compliant, Minerva MZX125 can monitor the operation of both sounders and beacons. RSM (Reflective Sounder Monitoring) will alert the user should an alarm fail to operate during the weekly test. MZX16R Repeater The Minerva MZX16R is a fully functional repeater that has the full user functionality of the Minerva MZX125 controller itself. Up to 7 fully functional repeaters can be driven from the 2 wire remote bus making installation of repeaters both simple and economical. Like the Minerva MZX125 panel, the repeater is fully approved to EN54 and houses it s own mains driven power supply making it power independent of the main controller. MXConsys Express Configuration Tool Installation and commissioning has been greatly simplified through the use of a user friendly software configuration tool, MXConsys Express. This simple to use configuration tool allows the system to be easily customised within the scope of the prevailing standards EN54 and BS5839. Customer Maintenance Features MINERVA MZX125 has been designed with the long term interest of the end user in mind. Standard user controls such as view statuses and isolate/de-isolate are simple to use with easy to follow text menus. Customers can also use the comprehensive Front Panel Updates feature to carry out many functions for example, change zone and point text or even add and remove devices from the system. This powerful feature gives users the option to take full management control of the fire detection and alarm system. New Standard for Door Control Preventing the spread of smoke in the event of a fire is essential and the fire detection panel has to be relied upon to actuate door closure. BS7273 part 4: Actuation of release mechanisms for doors, defines three category of door actuation. Minerva MZX125 can perform to the highest category A making it suitable for the most stringent life risk applications.

Detectors Minerva MX Series 800 addressable fire detectors include optical, heat, flame and carbon monoxide detection technologies. They all feature a low profile design with 360 degree visible LED indication and interchangeable base. The choice of detector is determined by the risk and the need to avoid false alarms. The three multi sensors in the range will provide the best level of cover for the majority of applications whilst the heat and flame detectors would be used for more challenging or specialist areas. 801PC 3oTec Triple Sensing Detector A combined optical, heat and carbon monoxide fire detector with exceptional performance. 3oTec offers early detection of a wide range of fire types from slow smouldering to flaming together with a high level of immunity from false alarms. Typical applications include sleeping accommodation, hotel bedrooms, halls of residence, senior homes. 801PH High Performance Optical Detector A combined photo-optical and heat detector that is ideal for the protection of escape routes and circulation areas. The sensitivity of the optical chamber is enhanced when heat is sensed resulting in reliable high performance detection. The 801PH will simultaneously operate as an EN54 A1R rated heat detector and high performance optical smoke detector. Typical applications include escape routes, corridors, circulation areas, offices. 801CH Carbon Monoxide Detector Ideal for detecting very slow smouldering fires, typically from discarded cigarettes. The 801CH can be used in dusty areas where optical smoke detectors could not be used and when the level of risk makes it inappropriate to rely on heat detectors alone. Typical applications include workshops, storage areas, textile industry. 801H Heat Detector The 801H heat detector can be used where environmental conditions preclude the use of smoke detectors. EN54-5 approved settings are available for use in normal ambient and high ambient temperature environments. Typical applications include kitchens, car parking garages.

801F Point Flame Detector The 801F solar blind flame detector provides a fast response to flame and can reliably detect a 0.1m 2 fire at a distance of 20m. Use to protect non-hazardous areas containing materials that are highly flammable. Typical applications include generator rooms, boiler rooms. Detector Bases and base accessories 5B Detector Base The 5B 5 detector base is the standard base for use with Minerva MX point detectors. It carries a built in locking pin and is electronics free permitting cable testing for trouble free installation. 5BI Isolator Base The 5BI 5 detector base provides short circuit protection for use with Minerva MX point detectors. An amber LED indicates isolator operated. 801RIL Remote Indicator The 801RIL is a remote LED indicator for use when the detector is out of sight or in a room that is likely to be locked. Fits a standard one gang backbox. CW-5B Protective Cage CW-5B is a robust steel protective cage for MX detectors using the standard 5 base or Isolator base. Ideal for schools and sport halls or whenever detectors need protection. Strong coated steel construction with 4 point fitting.

DHM5B Deckhead DHM5B Deckhead mount provides IP55 protection where the detectors are mounted in humid and environmentally challenging situations. The DHM5B deckhead mount provides a sealed waterproof mounting which protects the base electrical connections. Callpoints There are two addressable callpoints available for use with the Minerva MZX125 system. The CP820 Indoor callpoint and the CP830 IP67 rated outdoor callpoint. The indoor unit can be surface or flush mounted and both incorporate a test key facility, integral LED indication and can be fitted with a hinged cover to prevent accidental operation Ancillary Modules MX Addressable modules are housed in a M520 cover housing that fits a standard double gang electrical box and has an LED indication and programming socket. There are five addressable input/output modules specifically for use with the Minerva MZX125. RIM800 Relay Interface Module provides one set of change over contacts rated at 24Vdc. The device can be easily programmed to operate for a number of functions including interfacing and plant control. An additional module the HVR800 is a self powered high voltage relay which allows 240V loads of up to 10A to be driven directly via the addressable loop. CIM800 Contact Input Monitor will monitor volt free contacts whilst providing open and short circuit monitoring of the interconnections. Used to interface alarm and fault inputs from a variety of equipment with optional delay for sprinkler alarm inputs. TSM800 Door Control Module is a dedicated fire protection interface module that can control door actuation in accordance with BS7273 for category A and has built in line isolation. LIM800 Line Isolator Module provides short circuit protection to the addressable loop to meet the requirements of BS5839.

Sounders and Beacons Minerva MZX125 supports fully loop powered sounders and beacons that are driven directly from the detection loop, minimising cabling and installation costs. MXConsys Express will automatically configure any mix of sounders, up to the maximum permitted, with tone compatibility in accordance with BS5839. 802SB Sounder Base provides a convenient package for providing sound in smaller spaces with a 90dB output. Any of the MX detectors or the SAB801 sounder beacon can be fitted. SAB801 Addressable Beacon is a high efficiency low powered beacon that fits on either a standard detector base or the 802SB sounder base. It can be ceiling mounted or wall mounted to give optimum performance. AVBase Advanced 3000 series AV Base is an addressable detector base available as an independently controlled sounder and beacon combination (LPAV3000) or a sounder only device (LPSB3000). Both have built in line isolators and feature RSM, Reflective Sound Monitoring. The sounder is tone compatible with the other sounders in the Minerva MX range and the high efficiency LED beacon gives 360 o coverage. LPSY Loop Powered Symphoni Sounders and Sounder Beacon are indoor (available in red and white housings) and outdoor units (red I.P.65), all with built in line isolation and featuring Reflective Sound Monitoring (RSM). The range employs a transducer to actively monitor the units sound output during the weekly sounder test. The Minerva MZX controller will report any sounder not sounding when commanded. Similarly the units fitted with addressable beacons are monitored to ensure correct operation of the beacon. Integral line isolators reduce the need for separate line isolation devices saving installation time and wiring costs. 16 Tones are available from the sounder which include tones compatible with the 802SB sounder base and AVBase.

Technical Specifications Minerva MZX125 Control Panel & Repeater Mechanical Dimensions (mm): H W D Panel/Repeater Approx Weight: Panel Repeater Colour 370 x 325 x 126mm 7kg 6.6Kg Housings: RAL 7035 Control Facia: Pantone Grey 431C Environmental Operating Temperature: -5 C to +40 C Storage Temperature: -20 O C to +70 O C Relative Humidity: 90% RH continuous (non-condensing) EMC/RFI: EN50130-4, EN50081-1 Electrical Supply Voltage: Input Current: 230VAC 50/60 Hz 0.9 Amp Device Type Typical maximum 802SB Sounder Base 60 LPSB3000 Sounder base with isolator 90 LPAV3000 Sounder/beacon base with isolator 35 SAB801 Beacon with 5 base 120 or 40 with 802SB Beacon with 802SB sounder base LPSY800R Indoor sounder red LPSY800W Indoor sounder white LPSY865 Outdoor sounder red Combined maximum 55 LPAV800R Indoor sounder beacon red LPAV800W Indoor sounder beacon white LPAV865 Outdoor sounder beacon red

801PC 801CH 3otec 801PH High Carbon Triple Performance Monoxide 801H Heat 801F Point Sensing Optical Detector Detector Flame Detectors Detector Detector Detector Dimensions Diameter x Height mm 109 x 43 109 x 21.2-25 to +70 (-40 to + 90 short Operating Temperature Range Deg. C -10 to +55-20 to +70 0 to + 55 periods) -20 to +70 Storage Temperature Range Deg. C -20 to +55-40 to +80-20 to +55-40 to + 80-40 to +80 Relative Humidity (non condensing) 90% 95% 95% 95% 90% EN54-7 & EN54-7 & EN54-7 & Standards EN54-5 EN54-5 EN54-5 EN54-5 EN54-10 CP820 CP830 RIM800 Relay CIM800 TSM800 Door LIM800 Line Indoor Outdoor Interface Module Contact Input Control Isolator Ancillary Modules Callpoint Callpoint Monitor Module Module Dimensions Height 93 x 89x 59.5 Width x Depth mm with surface 93 x 97.5 back box x 73 Uses M520 ancillary cover to fit standard double gang box 87 x 148 x 23.5 Operating Temperature Range Deg. C -10 to +55-25 to +70-25 to +70-25 to +70-25 to +70-25 to +70 Storage Temperature Range Deg. C -30 to +70-30 to +70-40 to +80-40 to +80-40 to +80-40 to +80 Relative Humidity (non condensing) 95% 95% 95% 95% 95% 95% Electrical Characteristics Quiescent Quiescent Relay Contact: Standby: Relay Contact: Input 0.46mA 0.46mA 2A @ 24V dc 0.505mA max 2A @ 24V Current: Alarm 4.5mA Alarm 4.5mA Standby: Alarm: 4.5mA Quiescent 80μA max 0.46mA max max 0.425mA (normal) Alarm: 4.5mA Maximum Alarm 3.5mA max max Wiring 3.0mA (tripped) Resistance Monitored Circuit: 10 Ohms

Indoor use Outdoor use LPAV265 802SB SAB801 LPSY800-R LPSY800-W LPAV800-R LPAV800-W LPSY865 Sounder- Sounders & Sounder Addressable Sounder Sounder Sounder Sounder- Sounder Beacon IP65 Beacons Base Beacon Red White Beacon Red Beacon White IP65 Red Red Dimensions Height x 110 mm 108 mm Dia Width x Depth mm Dia x 37.5 x 32 104 x 104 x 91 108 x 108 x 100 Operating Temperature -25 C to -10 C to Range Deg. C +70 C +55 C -10 C to +55 C -20 C to +70 C Storage Temperature -40 C to -25 C to Range Deg. C +80 C +70 C -25 C to +70 C -25 C to +70 C Relative Humidity (non condensing) 95% 95% 95% 95% Electrical 1.2mA to 3.4mA to 3.4mA to 6.5mA to 6.5mA to 3.4mA to 6.8mA 3.25mA 8.1 ma 8.1 ma 13mA 13m A 8.1mA 6.5mA to 13mA Sound output dba @ 1m 90dB ± 3dB - 103dB ± 3dB 103dB ± 3dB AVBase LPSB3000 Addressable SAB801 Addressable Sounder Base Sounder Beacon Dimensions Height Diameter x Height mm 110 x 37 Operating Temperature Range Deg. C -10 to + 55 Storage Temperature Range Deg. C -25 to + 70 Relative Humidity (non condensing) 0.95 Output dba @ 1m 90

DATA SHEET For further information on how ADT can help you, contact your local office or phone free on 0800 010 999 or visit us at www.adt.co.uk Head Office: ADT Fire and Security plc, Security House, The Summit, Hanworth Road, Sunbury-on-Thames, Middlesex TW16 5DB. ADT and ADT Always There is a registered trademark of ADT Services AG and used under license. ADT reserves the right to modify or withdraw any product or service without notice. Ref No PSF230A Issue 3 January 2010 2010 Tyco International