THAILAND I. RATIONALE FOR REGULATION COUNTRY RATIONALE FOR REGULATION Thailand Consumer Protection. II. REGULATION BODY COUNTRY Thailand REGULATORY BODY Thai Industrial tandards Institute (TII) under the Ministry of Industry. III. LEGILATIVE FRAMEWORK COUNTRY LEGILATIVE FRAMEWORK Thailand Industrial tandards Act. (1968)
IV. MANDATORY TANDARD REVIED MATRIX ON MANDATORY TANDARD FOR THAILAND (A OF Oct 12, 2016) type or Domestic tandards TANDARD tandards Thailand 1 Incandescent lamps TI 4 Part 1-2529 (1986) IEC 60064 (1993) IEC 60432-1(1999) Thailand 2 Low-voltage distribution link fuses Thailand 3 PVC insulated Copper cables Thailand 4 Ballast for fluorescent lamps TI 10-2529 (1986) IEC 60269-1(1998), IEC 60269-3(1987) TI 11 Part 1-2553 (2010) IEC 60227-1 Ed 3.0 TI 11 Part 2-2553 (2010) (2007) TI 11 Part 3-2553 (2010) IEC 60227-2 Ed 2.0 TI 11 Part 4-2553 (2010) (1997) Am 1 (2003) TI 11 Part 5-2553 (2010) IEC 60227-3 Ed 2.1 TI 11 Part 101-2553 (2010) (1997) IEC 60227-4 Ed 2.1 (1997) IEC 60227-5 Ed 2.2 (2003) All Parts of IEC 60227 TI 23-2521 (1978) IEC 60920 (1990), Am.1(1993), Am.2(1995) IEC 60921(1988), Am.1(1990), Am.2(1994) tate reason if afety (), NEQ - NEQ - Part 1-2553 (2010) Addition: ubclause 3.4 Packaging Modification : ubclause 4.1.2 Replace - twocore cable: no prefer colour scheme; with - two-core cable: blue, brown scheme; NEQ -
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand 5 tarters for fluorescent lamps Thailand 6 PVC insulated aluminium cables Thailand 7 Lampholders for tubular fluorescent lamps and starterholders Thailand 8 Electric irons TI 366-2547 (2004) TI 1375-2547 (2004) TI 183-2547 (2004) IEC 60155 Ed 4.0 (1993), Am.1 (1995) - TI 293-2541 (1998) - - No IEC standard available TI 344-2549 (2006) IEC 60400 Ed 6.2 (2004) - IEC 60335-2-3 (2002) IEC 60335-1 Am.1 (2004) - ee TI 1375-2547 TI 1375-2547 ubclause 24.4 In the first paragraph, add words TI 166, TI 1234 before word IEC 60083 or IEC 60906-1. ubclause 25.25 In the last sentence of the first paragraph, replace words IEC 60083 with TI 166 and TI 1234 Thailand 9 Motor-compressors : safety requirements TI 812-2548 (2005) TI 812-2558 (2015) Effective date: Aug 16, 2017 IEC 60335-2-34 (2002) IEC 60335-2-34 Ed 5.0 (2012)
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand 10 Electrical witches TI 824-2551 (2008) IEC 60669-1 Ed 3.1 (2000) and Am 2 (2006) Thailand 11 Electric stoves; open type heating elements: safety requirements Thailand 12 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) TI 870-2532 (1989) IEC60335-2-9 NEQ Reference tandard I 2994 (1965) Am.1 JI C 9201 (1975) TI 909-2548 (2005) IEC 61009-1 (2003) ee TI 909-2548 ub-clause 1 Replace for rated voltages not exceeding 440 V a.c.; with for rated voltages between 220 and 440 V a.c.; ub-clause 5.3.1 Delete the second row of the table in subclause 5.3.1 ub-clause 9.22.1.3 Replace the testing temperature 25 o C 3 o C with 37 o C 3 o C
type or Thailand 13 AC electric fans : safety requirements Thailand 14 Fluorescent lamps : safety requirements Thailand 15 Electric rice-cookers : safety requirements Domestic tandards TI 934-2533 (1990) TI 934-2558 (2015) Effective Date: Aug 16, 2017 TANDARD tandards IEC 60335-2-80 IEC 60335-2-80 Ed 2.2 (2008) NEQ tate reason if No Reference TI 956-2533 (1990) IEC 60081 NEQ Reference tandard IEC 60081 (1984) B 5101 Part 1 (1975) TI 1039-2547 (2004) TI 1375-2547 (2004) - IEC 60335-2-15 (2002-07) IEC 60335-1, Am.1 (2004) B 5101 Part 3 (1975) ee TI 1375-2547 TI 1375-2547 ubclause 24.4 In the first paragraph, add words TI 166, TI 1234 before word IEC 60083 or IEC 60906-1. ubclause 25.25 In the last sentence of the first paragraph, replace words IEC 60083 with TI 166 and TI 1234 afety (),
type or Thailand 16 Mains operated electronic and related apparatus for household and similar general use : safety requirements Thailand 17 Uninterruptible power system Domestic tandards TANDARD tandards TI 1195-2536 (1993) IEC 60065 (1985) Am.1 (1989 TI 1291 Part 1-2553 (2010) TI 1291 Part 2-2553 (2010) TI 1291 Part 3-2555 (2012) IEC 62040-1 Ed 1.0 (2008) IEC 62040-2 Ed 2.0 (2005) IEC 62040-3 Ed 1.0 (1999) tate reason if afety (), TI 1195-2536 ub-clause 9.1.1 the current measured shall not exceed 0.3 ma (peak) -
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand 18 Tumbler dryers : safety requirements TI 1389-2539 (1996) IEC 60335-2-11 Ed 4.0 (1993) TI 1389-2539 ub-clause 1.1 cope excluding rated voltage 480 V. ub-clause 4.3.1.4 temp. rise of the accessible front surface made of glass, ceramic and plastic parts. ub-clause 4.14.6 minimum crosssectional area of conductors of supply cords ub-clause 4.15.3 nominal crosssectional area of conductors. ub-clause 4.18.2 requirements on creepage distance, clearance and distance through insulation. Thailand 19 Clothes washing machines household use TI 1462-2548 (2005) E Washing machines : safety requirements TI1463-2556 (2013) Effective date: ep 26, 2017 IEC 60335-2-7 Ed 7.0 (2008-06)
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand 20 Electric fryers: safety requirements TI 1509-2547 (2004) TI 1375-2547 (2004) - IEC 60335-2-13 Ed 5.0 (2002) IEC 60335-2-15 Ed5.0 (2002) IEC 60335-1 Am.1 (2004) TI 1509-2547 Clause 1 cope of the tandard cover fryers, frying pans and similar appliances as defined in ubclause 3.101,3.102 and 3.103 Remark 102 cope of the tandard does not cover high frequency-heating electric fryers. ubclause 3.101 Definition of electric fryers. ubclause 3.102 Definition of electric deep-fryers. ubclause 3.103 Definition of electric frying pans. Clause 6 Classified electric fryers into 3 classes; 0I, I and II.
type or Domestic tandards TANDARD tandards tate reason if afety (), see TI 1375-2547 ubclause 24.4 In the first paragraph, add words TI 166, TI 1234 before word IEC 60083 or IEC 60906-1. ubclause 25.25 In the last sentence of the first paragraph, replace words IEC 60083 with TI 166 and TI 1234
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand 21 Instantaneous water heaters :safety requirements TI 1693-2547 (2004) TI 1375-2547 (2004) - IEC 60335-2-35 (2002-10) IEC 60335-1, Am.1 (2004) ee TI 1375-2547 TI 1375-2547 ubclause 24.4 In the first paragraph, add words TI 166, TI 1234 before word IEC 60083 or IEC 60906-1. ubclause 25.25 In the last sentence of the first paragraph, replace words IEC 60083 with TI 166 and TI 1234
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand 22 Microwave ovens safety requirements TI 1773-2548 (2005) TI 1375-2547 (2004) IEC 60335-2-25 Ed.5.0 (2002) IEC 60335-1 Am.1 (2004) ee TI 1375-2547 TI 1375-2547 ubclause 24.4 In the first paragraph, add words TI 166, TI 1234 before word IEC 60083 or IEC 60906-1. ubclause 25.25 In the last sentence of the first paragraph, replace words IEC 60083 with TI 166 and TI 1234 Thailand 23 Lighting and similar equipment : radio disturbance limits TI 1955-2551 (2008) CIPR 15 Ed 7.1 (2007) (editorial modification) EMC
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand 24 Appliances for skin or hair care : safety requirement TI 1985-2549 (2006) TI 1375-2547 (2004) IEC 60335-2-23 Ed 5.1 (2005) IEC 60335-1 Am.1 (2004) ee TI 1375-2547 TI 1375-2547 ubclause 24.4 In the first paragraph, add words TI 166, TI 1234 before word IEC 60083 or IEC 60906-1. ubclause 25.25 In the last sentence of the first paragraph, replace words IEC 60083 with TI 166 and TI 1234
type or Domestic tandards TANDARD tandards Thailand 25 Electric thermo pots TI 2062-2543 (2000) IEC 60335-2-15 Ed 4(1995) Thailand 26 Room Air Conditioners Environment Requirement : Energy Efficiency Thailand 27 Household refrigerators : environmental requirements : energy efficiency IEC 60335-1 Am.1 (2004) tate reason if (editorial modification) TI 2062-2543 Contents of the standard deals with thermo pots only. TI 1375-2547 ubclause 24.4 In the first paragraph, add words TI 166, TI 1234 before word IEC 60083 or IEC 60906-1. ubclause 25.25 In the last sentence of the first paragraph, replace words IEC 60083 with TI 166 and TI 1234 afety (), TI 2134-2553(2002) No Reference - - E TI 2186-2547 (2004) No Reference - - E
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand Household refrigerators : safety requirements TI 2214-2548 (2005) TI 1375-2547 (2004) IEC 60335-2-24 Ed 6.0 (2002) IEC 60335-1 Am.1 (2004) TI 2214-2548 ubclause 5.7 Addition Appliances used in Thailand are testes at the ambient temperature for appliances used in warm damp equable climates ubclsuse 6.1 Addition Appliances used in Thailand shall be class OI, class I class II and Class III see TI 1375-2547 TI 1375-2547 ubclause 24.4 In the first paragraph, add words TI 166, TI 1234 before word IEC 60083 or IEC 60906-1. ubclause 25.25 In the last sentence of the first paragraph, replace words IEC 60083 with TI 166 and TI
type or Domestic tandards TANDARD tandards tate reason if afety (), Thailand 29 econdary cells and batteries containing alkaline or other non-acid electrolytes - safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications Thailand 30 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1 : general rules Thailand 31 Ballasts for tubular fluorescent lamps: energy efficiency requirements TI 2217-2548 (2005) IEC 62133 Ed.1.0 (2002) TI 2425-2552 (2009) IEC 61008 Ed.2.1 (2002) TI 2337-2557 (2014) Effective Date: Aug 16, 2017 (Editorial modification) IEC 62442-1 (2011) NEQ E
V. E OF REGULATION AND TYPE OF CONFORMITY AEMENT REGIME COUNTRY TYPE OF CON- FORMITY AE- MENT REGIME E OF REGULATION Thailand Certification Certification ystem of TII consists of two phases: 1. License Granting Granting a license is based on: 1.1 The results of tests which are conducted on products in accordance with the application standards. Consideration on this matter may be: (1) testing by designated laboratories, or (2) testing by testing laboratories being accreditation to IO/IEC 17025, or (3) testing by testing at manufacturer s premises under supervision of TII. 1.2 The results of manufacturer s quality control system assessment according to specified conditions. Consideration on this matter may be: (1) Factory visit for quality control system assessment, or (2) Acceptation of quality system certificates, or (3) Acceptation of CoC from the AEAN Listed CB. 2. urveillance After granting a license, the licensee will be followed up by: 2.1 sampling from factories for testing, 2.2 sampling from market for testing, 2.3 sampling for testing each import, 2.4 Factory visit for audit.
VI. FLOWCHART OF MEMBER COUNTRIE REGIME Application for Licences Testingl Manufacturer s Quality Control ystem Assessment Pass Fail Pass Fail Licence Granting Refuse of Application urveillance
VII. MAIN VOLTAGE, FREQUENCY AND MAIN PLUG CONFIGURATION Country Mains Voltage and Tolerance Mains Frequency and Tolerance Applicable Legislation Domestic tandard Mains Plug Configuration tandard - Diagram of Mains Plug Configuration- Thailand Bangkok Metropolita n Area 50 Hz ± 1% NA TI 166-2535 - - - 230 volts 1- phase 2 wires with earth tolerance Max 237 V and Min 214 V Other Areas 220 volts 1- phase 2 wires tolerance Max 240 V and Min 200 V Bangkok Metropolita n Area 50 Hz ± 1% NA - - - - 400 volts 3- phase 4 wires tolerance Max 410 V and Min 371 V
Mains Voltage and Tolerance Mains Frequency and Tolerance Applicable Legislation Domestic tandard Mains Plug Configuration tandard - Diagram of Mains Plug Configuration- Other Areas 380 volts 3- phase 4 wires tolerance Max 418 V and Min 342 V VIII. CONTACT PERON Country Thailand Contact Person and Address Mr.athaporn Rungrattanaubol tandards Division Thai Industrial tandards Institute (TII), Ministry of Industry, Rama VI treet, Bangkok 10400 Thailand Telephone (662) 202 3495, Telefax (662) 202 3495 E-mail : sthaporn@tisi.go.th