SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Similar documents
Water and ground source heat pumps 61WG kw. Heating

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Do you want a versatile solution

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

SIMPLICITY OR FULL MODULARITY?

SIMPLICITY FULL MODULARITY?

Air to water Heat Pump System

Advance Split

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Air to water Heat Pump System

AQUASNAP JUNIOR 30RHV

THE HEAT PUMP CHOICE OF PROFESSIONALS

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

AQUAHEAT ADVANCE SPLIT

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Neosys Product catalogue

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

TOSHIBA ESTIA POWERFUL CARRIER XP ENERGY 38AW/80AW CARRIER AQUASNAP 30AWH. CARRIER 80HMA Hydro Module for Monoblock Units

HT V2 HT Split

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Pure comfort & design

Pure comfort & design

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

EVI + INVERTER MODELS A Q U A P U R A

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Air conditioners Heating & Cooling

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Heat Pump Water Heater Commercial Leaflet 2012

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

50A KP 70A KP 90A KP 120A KP 150A KP 210A

PAC BT LOW TEMPERATURE HEAT PUMP

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Air conditioners Heating & Cooling

61AF High-Temperature Monobloc Air-to-Water Heat Pumps with Integrated Hydronic Module. Nominal heating capacity kw.

Inverter Hot Water Heat Pumps

Tower Green HE Hybrid

Inverter console UFV system. Compact design and personalised air flow selection

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

Pure comfort & design

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Air Conditioners Heating & Cooling

Daikin Altherma Low Temperature monobloc heat pump

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

PRODUCT RANGE HEAT PUMPS 2012

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

WHY A MHI HEAT PUMP?

Pure comfort & design

NATURAL HEATING MACHINE

Air Conditioning. Technical Data EEDEN AZQS-BV1

Product Line Introduction. Karl Zhang Technical support engineer

HITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Efficient heating that won t cost the earth

Daikin Altherma Low Temperature monobloc heat pump

61WG/30WG/30WGA. Water-Cooled and Condenserless Liquid Chillers Water-Sourced Heat Pumps. product selection data. 30WG optimized for cooling

VZ Chiller series. Water cooled inverter chiller. The highest peak in chiller technology

BWL air heat pumps BWS brine heat pumps

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

SHORAI. hatever you need. Do you want to improve your quality of life?

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

Europe s new energy label: raising the bar on energy efficiency

Air Conditioners Heating & Cooling

Conditioning your ambient, maximising your comfort.

30RB /30RQ

and sanitary hot water Catalogue 2009

Light commercial range. Passion at work

Transcription:

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS DE L AIR Comfort Module 5-2 kw Choose the easy heating solution!

Comfort Module: heating with Carrier system innovation Proper control of heat pumps is key to comfort and energy efficiency. Carrier achieves this offering high system integration, with a range of comfort module perfectly matching our heat pumps. Whatever is the application, heating only or reversible, in a new building or a renovation project, using our comfort modules limits the needs for field supply components, such as buffer tanks, hydraulic disconector, manometer, pressure relief valves, room controls, etc and therefore reduces the risk of installation design mistakes. Our range of comfort module can also manage the domestic hot water production, with or without interfacing to solar thermal control panels, and swimming pool heating. Quality: simply in Carrier s culture Carrier is committed to delivering the best operational products to every customer. Components and processes are accurately defined, tested and monitored during the entire product development process. In addition, Eurovent regularly tests our products to certify their accurate performance. System energy efficiency Outdoor weather conditions and indoor climate are constantly monitored by Carrier comfort module controls. There is no heat produced in excess and heat pump settings are always adjust to the most efficient possible. Our heat pumps can then reduce running cost by % or more when compared to technology using fossil fuel. The online selection software, only for professionals, will help you in finding the best solution for your customer. http://eco-sim.carrier.com Heating cost in per kwh.15.1.5 Propane Electric heating Oil Heat pump The data above is for comparison only and not contractually binding. It varies with each project and location type. Carrier participates in the ECC programme for Liquid Chilling Packages. Check ongoing certification validity: www.eurovent-certification.com or www.certiflash.com Carrier GREEN Choice of renewable energies At Carrier, comfort and the environment have always been priorities. With this new system you can exploit all the benefits of renewable energies. A system that uses outdoor air as the main energy source: reduced energy consumption and CO 2 emissions A heat pump based on the Aquasnap Plus generation with optimised energy efficiency Components chosen for enhanced user comfort and environmental care 2 Comfort Module - Choose the easy heating solution!

heat pumps made easy Weather compensation control 5 C 45 C COP.4 COP 4.4 Water temperature to heat emitters ( C) 5 45 4 5 2 25 2 Example: for -1 C outdoor temperature weather compensation results in a water temperature of 2 C 55 C COP 2.7 1 2 4 COP 1 Hours 5 4 2 1 % of the heating season OAT C A reduced operating temperature will increase the energy efficiency in heat pumps, using low temperature emitters type like under floor heating will help delivering high heating energy efficiency. In addition, weather compensation changes the water production temperature to the heat emitters, based on the outdoor temperature conditions. The heat pump produces water that is not very hot, except for the coldest days of the year. More energy efficiency and control is delivered by indoor temperature control. -7 - -5-4 - -2-1 1 2 4 5-7 8 9 1 11 12 1 14 15 1 17 18 19 2 1 OAT C -- Water compensation curve Climate conditions for Lyon, France 1 Base outdoor design temperature 2 Maximum leaving water temperature Outdoor temperature without heating Auto calibration feature of weather compensation can take short term indoor thermal load variations into account for example solar radiation gains. This smart control technology, used for all Carrier heating systems, guarantees end user comfort and system energy efficiency throughout the heating season. The two-zone kit: Carrier developed a kit to control two different heat emitters type in the same building, for example fan coils units in individual rooms and heating floors in large open areas. Even if they use one heat emitters type, buildings with different zones can require independent comfort zones. Areas with high solar gains (bay windows) cannot be controlled the same way as interior areas. This is especially true for U or L shaped buildings, where only independent control of comfort zones prevents cold or overheated areas. Anyhow, we all have our own perception of the ideal room comfort temperature. Having several comfort zones in the building ensures that everybody enjoys the desired temperature. 18 C Module with two-zone-kit Comfort Module - Choose the easy heating solution! 21 C

Components of the system Inverter-driven outdoor unit Two versions available: split (8AW) or monobloc (AWH) Choice of water or refrigerant (R-41A) heat transfer technology between outdoor unit and Comfort Module. Reliability, ease-of-installation and energy performance of the system are the same. User interfaces The Carrier user interface has a contemporary and discreet design with a backlit LCD screen that easily blends in with any room decor. It offers many functions such as weekly scheduling and several modes that are accessible by quick-access keys: night-time/eco/ comfort modes. One of the best energy coefficients of performance in the market Twin-rotary DC inverter technology, variable-air volume fans, electronic expansion valve and large-surface heat exchanger ensure an energy efficiency ratio above 4 at standard operating conditions. Wide inverter operating range The compressor speed variation from 2 to 1% permits precise adjustment of capacity and leaving water temperature during the whole heating season, avoiding energy waste of on/off control mode of inverter compressor. High water temperature all year round The outdoor unit operating range in heating mode goes from -2 C to + C outdoor temperature. Heating and domestic hot water production are guaranteed all year round. 4 Comfort Module - Choose the easy heating solution!

Module with two-zone-kit HEATING SOLUTIONS Single-zone module Comfort Module Innovative control The heat pump operating temperature is adjusted and optimised to ensure occupant comfort and reduced energy consumption. It also controls domestic hot water production. It constantly measures outdoor temperature and indoor comfort conditions. A compact and complete unit The Comfort Module is exceptionally compact with dimensions similar to those of a modern wall boiler. But the module includes all water and electric components required for reliable and safe operation: expansion tank, buffer tank, pressure gauge, purge, disconnect switch, pressure switch etc. And everything is easily accessible. Second optional independent zone The two-zone kit permits control of several heat emitter types with different operating temperatures such as heating floors or radiators. Each zone can be in a different part of the building, on the ground floor or a higher floor, a night zone or a day zone, with different comfort temperatures and programs. Simple efficient options From swimming pool heating in the summer to the high-pressure circulation pump the installer will select the accessories to ensure that the system is suitable for the desired comfort conditions and energy efficiency targets. Domestic hot water tank The right model for any application The hot water tank is made of enamelled steel with reinforced thermal insulation. It is available in two sizes, and 2 litres, with a single or dual heat exchanger for easy connection to a solar panel system. Used in connection with a solar storage system, anti-legionella protection is always controlled by the Comfort Module. Simple efficient functions All tanks include an electric heater controlled by the Comfort Module. It ensures anti-legionella protection (programmable). A factory-installed anode protects the tank against limescale deposits and corrosion. Comfort Module - Choose the easy heating solution! 5

Air to water monobloc system AWH + 8HMA HEATING SOLUTIONS Part number Heat pump Maximum heating capacity* 5 C LWT Comfort module -7 C OAT -2 C OAT C OAT +2 C OAT +7 C OAT 8HMA-M 8HMA-M 8HMA-M 8HMA-T 8HMA-T9 AWH4 kw 2,9,1,,5 4,7 AWH kw,5,8 4,1 4,,1 AWH8 kw 4, 4,8 5,2 5,5 8, AWH12 kw 7,9 8,9 9, 1,1 1,5 AWH 15 kw 9,1 1,2 11,1 12,1 1,5 * Without booster electrical heater or boiler back up 8HMA is also compatible with RQ 17 to 21 and 1AF 14 and 19. Heat pump control is then done by on/off contact. Professional in charge of the system design and installation must check that installation water volume is sufficiant to ensure proper functionning of the heat pump. Connection piping between indoor and outdoor unit containts water. Comfort module 8HMA-M 8HMA-M 8HMA-M 8HMA-T 8HMA-T9 Booster Electrical Heater kw 9 Boiler back up 1 stage stages stages stages Buffert tank volume l 1 1 1 1 1 Dimensions, H x L x D mm 8 x 45 x 2 8 x 45 x 2 8 x 45 x 2 8 x 45 x 2 8 x 45 x 2 Operating weight kg 4 5 5 5 5 Power supply V-ph-Hz 2-1-5 2-1-5 2-1-5 4--5 4--5 Maximum leaving water temperature* C 8 8 8 8 8 * With booster electrical heater or boiler back up Heat pump AWH4HC AWHHC AWH8HC AWH12HC AWH15HC Maximum leaving water temperature C Nominal heating capacity* kw 4 7 12 14 Minimum heating capacity kw 1,9 1,2 4,,4 Maximum heating capacity kw 4,7,1 8, 1,5 1,5 Nominal absorbed power* kw,98 1,5 1,8,,54 COP at nominal conditions* kw/kw 4,15 4,28,97,95 4,9 Nominal cooling capacity** kw, 4,7 5,8 1,2 1 Minimum cooling capacity kw,8,,7,,9 Maximum cooling capacity kw,45 5, 5,8 11,7 1,55 Nominal absorbed power* kw 1,1 1,58 1,9,4 4,42 EER at nominal conditions** kw/kw,2 2,98 2,9 2,95 Heating nominal sound power*** db(a) 2 2 4 7 8 Cooling nominal sound power**** db(a) 4 4 5 8 9 Heating sound pressure level*** db(a) 42 42 44 47 48 Cooling sound pressure level**** db(a) 44 44 45 48 49 Dimensions, H x L x D mm 821 x 98 x 5 821 x 98 x 5 821 x 98 x 5 1 x 98 x 5 1 x 98 x 5 Operating weight Kg 59 1 71 15 1 Power supply V-ph-Hz 2-1-5 2-1-5 2-1-5 2-1-5 2-1-5 Options Two-zone kit compatible with all model of comfort module Intermediate heat exchanger to isolate brine water from heat pump from terminal unit fresh water Additional user interface Anti-vibration mounts for outdoor unit Thermal cut-out for heating floor applications Outdoor temperature sensor Three-way valve for domestic hot water production Installation kit for three-way valve in the two zone kit 2 or liters hot water tank with or without solar panel connection Roof panel for two zone kit if this is not installed below the comfort module Pump kit Swimming pool heating control kit * Standard Eurovent LCP/A/CHF conditions in heating mode: water heat exchanger entering/leaving water temperature C/5 C, outside air temperature 7 C db/ C wb ** Standard Eurovent LCP/A/AC conditions in cooling mode: water heat exchanger entering/leaving water temperature 12 C/7 C, outside air temperature 5 C. *** Based on the following conditions: entering/leaving water temperature 5 C/ C, outside air temperature 7 C. **** Based on the following conditions: entering/leaving water temperature 12 C/7 C, outside air temperature 5 C. Note: The sound pressure level is measured in a hemisperic field at 4 m distance from the unit. Comfort Module - Choose the easy heating solution!

Air to water split system 8AW + 8AW HEATING SOLUTIONS Reference Heat pump Maximum heating capacity* 5 C LWT -7 C OAT -2 C OAT C OAT +2 C OAT +7 C OAT 5M 5M 5M 5T Comfort module 115M 115M 115M 8AWH 5H7 kw 4,1 4,2 4,2 4, 5,9 8AWH 5H7 kw 4,5 4,8 5,1 5, 7,8 8AWH 9H7 kw,8 7,9 8,7 9,2 11,1 8AWH 115H7 kw 8,4 1,4 1,7 11,5 1,8 * Without booster electrical heater or boiler back up Connection piping between indoor and outdoor unit containts refrigerant 115T 115T9 Comfort module 5M 5M 5M 5T 5M 5M 5M 5T Application Reversible Reversible Reversible Reversible Heating only Heating only Heating only Heating only Booster Electrical Heater kw Boiler back up 2 stages 2 stages 2 stages Boiler back up 2 stages 2 stages 2 stages Buffert tank volume l 1 1 1 1 1 1 1 1 Dimensions, H x L x D mm 8 x 45 x 8 x 45 x 8 x 45 x 8 x 45 x 8 x 45 x 8 x 45 x 8 x 45 x 8 x 45 x 2 2 2 2 2 2 2 2 Operating weight kg 48 48 48 48 48 48 48 48 Power supply V-ph-Hz 2-1-5 2-1-5 2-1-5 4--5 2-1-5 2-1-5 2-1-5 4--5 Maximum leaving water temperature* C 8 8 8 8 8 8 8 8 Heat pump 115M 115M 115M 115T 115T9 115M 115M 115M 115T 115T9 Application Reversible Reversible Reversible Reversible Reversible Heating only Heating only Heating only Heating only Heating only Booster Electrical Heater kw 9 9 Boiler back up 2 stages 2 stages 2 stages 2 stages Boiler back up 2 stages 2 stages 2 stages 2 stages Buffert tank volume l 1 1 1 1 1 1 1 1 1 1 Dimensions, H x L x D mm 8 x 45 8 x 45 8 x 45 8 x 45 8 x 45 8 x 45 8 x 45 8 x 45 8 x 45 8 x 45 x 2 x 2 x 2 x 2 x 2 x 2 x 2 x 2 x 2 x 2 Operating weight kg 5 5 5 5 5 5 5 5 5 5 Power supply V-ph-Hz 2-1-5 2-1-5 2-1-5 4--5 4--5 2-1-5 2-1-5 2-1-5 4--5 4--5 Maximum leaving water temperature* C 8 8 8 8 8 8 8 8 8 8 * With booster electrical heater or boiler back up Heat pump 8AW5H7 8AW5H7 8AW9H7 8AW115H7 Maximum leaving water temperature C Nominal heating capacity* kw 5,5 9, 11,5 Minimum heating capacity kw 1,5 1,,,5 Maximum heating capacity kw 5,9 7,8 11,1 1,8 Nominal absorbed power* kw 1,22 1,59 2,17 2,81 COP at nominal conditions* kw/kw 4,1 4,1 4,2 4,1 Nominal cooling capacity** kw 4,2 5, 7,9 9, Minimum cooling capacity kw 1, 2,,9 4,1 Maximul cooling capacity kw, 7, 9,5 12,1 Nominal absorbed power* kw 1,1 1,5 1,94 2,7 EER at nominal conditions** kw/kw,5,5 4,5,8 Heating nominal sound power*** db(a) 4 8 9 7 Cooling nominal sound power**** db(a) 4 5 8 7 Heating sound pressure level*** db(a) 44 48 49 5 Cooling sound pressure level**** db(a) 44 45 48 5 Dimensions, H x L x D mm 9 x 9 x 2 82 x 9 x 2 1 x 9 x 2 1 x 9 x 2 Operating weight Kg 49 51 88 88 Power supply V-ph-Hz 2-1-5 2-1-5 2-1-5 2-1-5 Options Two-zone kit compatible with all model of comfort module Additional user interface Anti-vibration mounts for outdoor unit Thermal cut-out for heating floor applications Outdoor temperature sensor Three-way valve for domestic hot water production Installation kit for three-way valve in the two zone kit 2 or liters hot water tank with or without solar panel connection Roof panel for two zone kit if this is not installed below the comfort module * Standard Eurovent LCP/A/CHF conditions in heating mode: water heat exchanger entering/leaving water temperature C/5 C, outside air temperature 7 C db/ C wb ** Standard Eurovent LCP/A/AC conditions in cooling mode: water heat exchanger entering/leaving water temperature 12 C/7 C, outside air temperature 5 C. *** Based on the following conditions: entering/leaving water temperature 5 C/ C, outside air temperature 7 C. **** Based on the following conditions: entering/leaving water temperature 12 C/7 C, outside air temperature 5 C. Note: The sound pressure level is measured in a hemisperic field at 4 m distance from the unit. Comfort Module - Choose the easy heating solution! 7

Carrier, for the environment Carrier believes that industry leadership demands environmental leadership. In fact, environmental stewardship is one of Carrier s core values. Carrier continuously works to improve the environmental performance of its products and services, operations and culture to help achieve a sustainable society. Carrier, for performance Carrier strives for continuous growth to reinforce its leadership position, achieve world-class financial performance and continuously improve the productivity of its assets and resources. Carrier, for service The Carrier service delivery model maintains a reputation for high customer satisfaction and delivers service excellence with strong communication channels, industry-leading technicians, continuous improvement of contracts and a highly experienced management team. Carrier, for innovation Order No.: 1878-2.2.212. The manufacturer reserves the right to change the product specifications, data and images without notice. Carrier reserves the right to change certain information and specifications contained in this document at any time and without prior notice. Since standards, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication. Carrier is a company of ideas, committed to research and development, whose founder inspires the company to reach the next innovative, powerful and marketable idea. Carrier, to be your expert Carrier delivers global solutions across the broadest range of heating, cooling and refrigeration applications. With a proven track record of leadership and industry expertise, we are here to meet your needs with our portfolio of market-leading products and services. www.carrier.com