Room Acoustic Design in Open-Plan Offices

Similar documents
Optimum Room Acoustic ComfortTM (RACTM) can be achieved by using a selection of appropriate acoustic descriptors

Supporting acoustic environment design in spatial planning of urban areas

Acoustics in open-plan offices A laboratory study

Defining the Acoustic Environment of (semi-)open Plan Offices

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

Evaluation of fixed point H2S gas detectors intended for use in industrial safety applications

A micropropagation system for Eucalyptus dunnii Eucalyptus sp

Real-Time Active Pipeline Integrity Detection (RAPID) System for Corrosion Detection and Quantification

Effects of Collaborative Workspaces on Employee Satisfaction and Productivity

Acoustic design of open-plan offices and comparison of requirements in the Nordic countries

Low Cost Smart Stick for Blind and Partially Sighted People

ACOUSTICAL DESIGN OF THE CONCERT HALL OF PÉCS CONFERENCE AND CONCERT CENTRE

Caroline Scotto. To cite this version: HAL Id: hal

Axillary bud proliferation of 2 North American oak species: Quercus alba and Quercus rubra

Alarm Management at Operators Workstations

Lecture 18 Auditorium Acoustics

SPEECH PRIVACY DISTANCE IN 3 OPEN-PLAN OFFICE LAYOUTS: COMPUTER MODELLING AND SIMULATION APPROACH

Acoustical Requirements in Architectural Design Studios

Performance of Green roof in stormwater management regarding high-resolution precipitation fields

SOUND PERCEPTION PARAMETERS IN URBAN PUBLIC SPACES

Two kinds of gravitational ejector refrigerator stimulation

CONTACTLESS THERMAL CHARACTERIZATION OF HIGH TEMPERATURE TEST CHAMBER

Prediction of Psychoacoustic Parameters

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones

Laurent Maurin, Stéphane Rougeault, Véronique Dewynter-Marty, Jocelyn Périsse, Dominique Villani, Jean-Reynald Macé, Pierre Ferdinand

AUDITORIUM OF THE MORGAN LIBRARY, COMPUTER AIDED DESIGN AND POST-CONSTRUCTION RESULTS

AFMG. Design for Speech Intelligibility Using Software Modeling. Stefan Feistel, Bruce C. Olson AHNERT FEISTEL MEDIA GROUP

André Potvin, Claude Demers. To cite this version: HAL Id: hal

Performance Evaluation of Green Roof for Thermal Protection of Buildings In Reunion Island

S TAR-ORION S OUTH D IAMOND P ROJECT E NVIRONMENTAL I MPACT S TATEMENT APPENDIX A FUNDAMENTALS OF ACOUSTICS

Fact File 75. Published Document PD CEN/TS 54-32:2015 Fire detection and fire alarm systems

REPORT SUNDBYBERG KOMMUNHUS, MEASUREMENT OF SOUND PRESSURE LEVELS IN OPEN PLANE OFFICES STORKONOTOR

ROOM FOR GREAT DAYS. c90 - a new generation of modular space for offices

Effects of hearing protection on detection and reaction thresholds for reverse alarms

Shape the Design with Sound Performance Prediction

PERFORMANCE-BASED SIMULATION FOR THE PLANNING AND DESIGN OF HYPER DENSE URBAN HABITATION

Quantification of flow rates through virgin and exposed geomembranes and multicomponent geosynthetic clay liners

Efficiency of air dehumidification on the drying process in a food plant

The Use of Public Address System to Improve Tunnel Safety - Current Practices. Lim Hock Tay

Fire Alarm Intelligibility. Chris Nolan

soundroom. design: Tomek Rygalik 2017

Room Acoustics, PA Systems and Speech Intelligibility for Voice Alarm Systems using the example of the Cruise Center Steinwerder

o Rear HVAC columns (Priority 1: Item 3) the rear ceiling area: be more dead for the organ and traditional music. (Priority 2: Item A)

Quality of the Visual Environment

Implications IN THIS ISSUE. A Newsletter by InformeDesign. A Web site for design and human behavior research.

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

Numerical simulation of locomotive fires in the Lyon-Turin tunnel

Acoustics in Practice International e-journal of the European Acoustics Association (EAA)

Habitat and Stone Enclosure of Corsica

Development of a hybrid refrigerator combining thermoelectric and vapor compression technologies

Design Guidance on eliminating office noise: A psychoacoustic approach

Dynamic Lights Towards Dynamic, Intelligent and Energy Efficient Urban Lighting

This document is a preview generated by EVS

JOIN THE ECOPHON SOLO DESIGN CHALLENGE. Make design history! SOUND SCIENCE. four. stories

>>>PORT- FOLIO>>> Ran Kuang. Master of Design Institute of Design, Illinois Institute of Design

Exploring lighting cultures - Beyond light and emotions

Effects of pruning on the apple tree: from tree architecture to modeling

Privacy Panels. Haller. Modular acoustics

Ordinary sonic public space. Sound perception parameters in urban public spaces and sonic representations associated with urban forms

TEHRAN LONG TERM URBAN RAIL PLAN

People ignore design that ignores people. Frank Chimero

New technology, new soundscape. Environmental transformations in a Colombian traditional neighborhood

Chapter 1 Introduction

Norwich (United Kingdom), 9-10 September 2004

RAUWORKS INNOVATIVE SOLUTIONS FOR MODERN OFFICE ENVIRONMENTS. Construction Automotive Industry.

REDEFINING INNOVATION AND SUSTAINABILITY IN THE DESIGN OF INTERIOR ACOUSTICS

DESCRIBING TRENDS IN URBAN DESIGN. Claire Jamieson and Professor Robert Adam for ADAM Urbanism

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

MNEC NFPA 72 WHITE PAPER

The Role of Urban Gardening for European s Ageing Societies

draft dated 9/17/2015 page 1

NEW HV/LV TRANSFORMER SUBSTATION WITHIN A BUILDING INTENDED FOR OTHER NON ELECTRICAL USES WITH ADVANCED FUNCTIONALITIES

Nicolas Rémy, Théo Marchal, Grégoire Chelkoff, Hengameh Amini, Jean-Luc Bardyn, Noha Gamal. To cite this version:

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Power Amplifiers. Equalizers

Use of local convective and radiant cooling at warm environment: effect on thermal comfort and perceived air quality

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ROLE OF THE FIRE PROTECTION ENGINEER IN THE CONSTRUCTION DESIGN PROCESS

HOlistic and Sustainable Abatement of Noise by optimized combinations of Natural and Artificial means

MD and Its Impact on Lab Facilities

Rooting and weaning of apple rootstock YP

Cooperative Research in Water Management

Signing Up... 1 Logging in for the First Time... 2 The Search Panel... 3

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM

Application Note. Application Note for BAYEX

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES

Dynamic Alarm Management in Next Generation Process Control Systems

WHY SURROUND SYSTEMS DON T WORK

Fagerhult The Art of Light

1. Introduction to Linköping

Typologies of Hybrid Ventilation in Schools

Study and Assessment of Low Frequency Noise in Occupational Settings

Four Ways to Reduce Office Noise

Chapter 4 Availability of International E-waste Statistics

Pyykkö, Saara Colours of a Neighbourhood

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Report Number BTC 15450A

Office Furniture Standards

Master Gardener Volunteer Expectations Guidelines

Los Angeles, CA Studio DESIGN PERFORMANCE VALUE

ACTIVE VENTILATION SYSTEMS

Transcription:

Room Acoustic Design in Open-Plan Offices Erling Nilsson, Björn Hellström To cite this version: Erling Nilsson, Björn Hellström. Room Acoustic Design in Open-Plan Offices. Société Française d Acoustique - SFA. 10ème Congrès Français d Acoustique, Apr 2010, Lyon, France. 2010. <hal- 00542612> HAL Id: hal-00542612 https://hal.archives-ouvertes.fr/hal-00542612 Submitted on 3 Dec 2010 HAL is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. L archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

10ème Congrès Français d'acoustique Lyon, 12-16 Avril 2010 Room Acoustic Design in Open-Plan Offices Erling Nilsson 1, Björn Hellström 2 1 Saint-Gobain Ecophon AB, Box 500 SE-260 61 Hyllinge, Sweden 2 Tyréns, SE-118 86 Stockholm, Sweden In a Nordic cooperation project the acoustical conditions in open-plan offices was investigated. Measurements have been carried out in five open plan offices accompanied with an inquiry gathering the subjective judgments by the staff. A program for the acoustical measurements was designed specifying how to perform the measurements and which type of parameters to measure. The acoustical parameters included in the measurements are Reverberation time T 20, Early Decay Time (EDT), Clarity (C 50 ), Speech transmission index (STI), Speech intelligibility index (SII), Privacy Index (PI), Rate of spatial decay of sound pressure levels per distance doubling (DL 2 ), Excess of sound pressure level with respect to a reference curve (DL f ), background noise levels in occupied and unoccupied offices. In two of the offices a refurbishment program was carried out. Measurements as well as questionnaire were accomplished after refurbishment. The effect on room acoustic parameters DL 2 and DL f and on subjective judgments by the staff will be presented in this paper. 1 Introduction The extensive use of open-plan solution for offices has highlighted the problems related to the acoustical conditions in these environments. The variety of the architectural design, the planning of working areas and the activities going on has also been challenging for the acoustic evaluations. In Europe the purpose of using an open plan structure is often to create flexible solutions which support communication between employees and working teams but also gives possibility for concentrated work. In these environments it is normally not a realistic goal or even the intention to create high speech privacy between workplaces. Instead the organisation of work places should support communication between working members in the same team but depress speech sound from neighbouring groups working with other projects. This implies that preventing sound propagation over long distances is important. Nevertheless, irrelevant speech is the major source of disturbances in OPO and it s well recognized that it has a detrimental effect on cognitive performances [1, 2]. In a modern flexible OPO the creation of a functional workplace is a complex process were the acoustical planning only is a part of a series of considerations that has to be handled. The open-plan office should support both communication and concentrated work. Thus, for an OPO to be an efficient and comfortable workplace there a number of factors besides the acoustic treatments that has to be fulfilled like sufficient number of sound insulated rooms for concentrated work and meetings flexible solutions for computer and mobile phone with wireless connections education of staff of purpose with OPO and how to behave to decrease annoyance planning of workplaces to simplify communication between team members and minimize disturbance between different groups acoustic planning for the activity going on In [3] a method to approach room acoustic design is presented. The main principle in this approach is taking into account the multidimensional character of human s perception of sound, the type (shape, volume, distribution of absorption) of the room and the activity that is planned for the room. This threefold of factors interacts and has to be considered in the acoustic design to secure an appropriate acoustic environment. A consequence of the human perception of sound is that normally several room acoustic descriptors have to be used for a relevant evaluation of the room acoustic. Only using reverberation time will often be insufficient and sometimes even misleading [4]. Due to the shape, size and distribution of sound absorbing material it is appropriate to distinguish between different room types. Excluding large industrial spaces and performance room like concert halls and theatres and restrict the analysis to ordinary rooms there are at least three groups of rooms that have to be analysed in different ways. The reverberant rooms were the diffuse field assumption is valid are room types were the late reverberation time (T 20 or T 30 according to ISO 3382-1) work as a global parameter and characterize the acoustical conditions sufficiently well. However, this room type is unusual in practise. A more common room type is the room with an absorbent ceiling. In these room types the diffuse field assumption is normally not fulfilled and the reverberation time alone is not enough to characterise the acoustic conditions. Room acoustic descriptors related to different sensations like steady-state sound levels, speech clarity and reverberance have to be evaluated separately. Another room type is rooms with extended forms like openplan spaces and corridors. Typically for these room types are that room acoustic parameters varies over distance from source and are not useful as global descriptors of the interior environment. For these spaces measures related to sound propagation seems to be more appropriate for room acoustic characterisation [5, 6] The aim of this work is to suggest appropriate objective measures for a simple and practical evaluation of open-plan offices. The purpose of the measures is to secure that the

overall basic acoustic conditions in an open-plan office are sufficient for the activities going on. The intention is that the measures reflect the interior fittings of the space and reflect critical parameters regard to the design and planning of the office. These critical parameters can apply to the choice of material and outer layer for the room s surfaces and furnishings, general room layout and/or the use of the workstations. A measurement methodology for evaluating the room acoustics in large office space in a meaningful way can also lead to work environmentally sound solutions. This will benefit both employers and workers leading to greater efficiency, less absenteeism and increased job satisfaction. It can also help to increase accessibility for individuals with hearing loss. A good acoustic environment minimizes the risk that office workers have to leave work early because of significant pressure from an unsuitable working environment. 2 Method 2.1 Measurement specification The acoustical parameters included in the measurements are Reverberation time T 20, Early Decay Time (EDT), Clarity (C 50 ), Speech transmission index (STI), Speech intelligibility index (SII), Privacy Index (PI), Rate of spatial decay of sound pressure levels per distance doubling (DL 2 ), Excess of sound pressure level with respect to free field (DL f ), background noise levels in occupied and unoccupied offices. In this paper we will focus on the parameters DL 2 and DL f. The meaning of these measures is illustrated in figure 1. Reverberation times and speech transmission index were measured at workplaces while DL 2 and DL f were measured at two different paths, one along the workplaces and one in the diagonal direction of the room. This illustrated in figure 2. Sound level, db 60 55 50 45 40 35 30 Background sound DL f DL 2 Free field 2 m 4 m 8 m Without acoustical treatment Distance (d) from the speaker, metres With acoustical treatment 16 m Figure 1. Example of sound propagation curves in an openplan office with and without acoustical treatment. DL 2 measure the decrease of sound level per doubling of distance. DL f measure the difference between the SPL of the sound source in the room and corresponding value in free field. Figure 2. The open plan office with measuring positions (left) and measuring paths for the sound distribution curves (right) 2.2 Inquiry The measurements of objective room acoustic parameters were accomplished by an inquiry among the staff. The purpose of the questionnaire was to identify critical criteria with regard to the subjective impression of the working environment. Moreover, the results from the questionnaires were compared with measured room acoustic parameters. The inquiry and the room acoustic measurements were performed both before and after the refurbishment of the open-plan offices. Before implementation, the questionnaire was tested on experts on acoustics, as well as on a number of people who work in open-plan offices. The completed questionnaire comprises of sixty questions, and takes at most twenty minutes to answer. 2.3 Acoustic treatment In general terms the refurbishment in the two offices consist of partly or totally new suspended ceilings corresponding to α w >0.9. As a complement to the acoustic ceilings patches of free hanging sound absorbing units were installed over the workplaces. This is illustrated in figure 3. In one of the offices sound absorbing screens were placed between the workplaces. In both offices, wall absorbers were mounted on one of the walls. The basic idea behind the acoustic design was to prevent speech propagation between different working teams.

Before refurbishment Office DL 2 (db) DL f (db) 1 5.2 7.4 2 5.8 6.8 Figure 3. Free hanging absorbing units above workplaces 3 Results 3.1 Measurement of DL 2 and DL f Speech is the most disturbing sound signal in an openplan office. How to increase the attenuation of speech between different working groups is consequently a question of major importance in the acoustical planning. To quantify the attenuation of sound during propagation measures like DL 2 and DL f are appropriate. These parameters are defined in ISO 14257 [7]. In this investigation A-weighted pink noise was used as a sound source. Knowing DL 2 and DL f and specifying a target value for acceptable speech level L c at a work place, the distance needed between the person talking and the workplace is given by d c 0.3( L + DL L ) / DL speech f c 2 = 10 (1) where d c is the distance of comfort, L speech is the level of speech and L c is the acceptable speech level at the work place. DL 2 and DL f will depend on the chosen evaluation interval. In many offices a suitable interval appears to be from 3 to 16 meters. DL 2 is given by the regression line over this region and DL f is given by the average value over the same distance. The validity of equation 1 is limited to the evaluation interval. This (comfort) distance gives an indication of how to proceed in the acoustical design work concerning absorbing materials, screens, furnishing etc. and act as a useful tool for the architects. DL 2 and DL f have been measured in two offices both before and after refurbishment. The values have been evaluated over the range 3 to 16 meters. The results are presented in table 1. As appear from table 1 the acoustical treatment has affected both DL 2 and DL f. Since DL 2 has increased and DL f has decreased after treatment this imply that for distances larger than 3 meter from the source, the speech level will decrease faster as a function of distance and the speech level in each position has diminished. As a consequence and according to equation 1 the distance to reach an acceptable speech level has been shortened. After refurbishment Office DL 2 (db) DLf f (db) 1 9.9-0.1 2 6.7 1.0 Table 1: Sound propagation measures DL 2 and DL f before and after refurbishment In table 2 equation 1 has been used to calculate the distance needed to reach a sound pressure level of 35 db(a) from a sound source producing a sound pressure level of 55 db(a) at 1 meter. The calculation is carried out for the two offices in table 1 and for the cases before and after refurbishment. Before refurbishment Distance to reach 35 db(a) when the Office speech level is 55 db(a) 1 > 16 meter 2 > 16 meter After refurbishment Distance to reach 35 db(a) when the Office speech level is 55 db(a) 1 4 meter 2 5 meter Table 2 : Calculation of distance of comfort 3.2. Questionnaire The questionnaire comprises 60 questions. Most of the questions are divided into five multiple-choice questions. The number of respondents regarding the answer of the questionnaire before and after the acoustic treatment was 14, respectively 10 in office 1. In office 2 the corresponding numbers was 16, respectively 7. For the sake of clarity we will only refer to the question how the staff considers the acoustic environment from a general point of view before and after the refurbishment. The results are presented in figure 4 and 5.

neither good or very good Q26: How do you consider the acoustic environment from a general point of view? very good neither good or very good 0 10 20 30 40 50 60 70 % Office 1, after treatment Office 1, before treatment Figure 4. Subjective judgements before and after refurbishment for office 1. very Q26: How do you consider the acoustic environment from a general point of view? good 0 10 20 30 40 50 60 % Office 2, after treatment Office 2, before treatment Figure 5. Subjective judgements before and after refurbishment for office 2. References [1] SJ Schlittmeier, J Hellbrück, R Thaden, M Vorländer, The impact of background speech varying in intelligibility: Effects on cognitive performance and perceived disturbance, Ergonomics, 2008. [2] N Venetjoki, A Kaarlela-Tuomaala, E Keskinen, V Hongisto, The effect of speech and speech intelligibility on task performance, Ergonomics 49(11), 1068-1091 (2006). [3] C Svensson, E Nilsson, Optimum Room Acoustic Comfort (RAC ) can be achieved by using a selection of appropriate acoustic descriptors in Proceedings of Euronoise 2008, Acoustic 08, Paris. [4] E Nilsson, Sound Decay and Steady-State Level in Rooms with Ceiling Treatment, International Symposium on Room Acoustics, Satellite Symposium of the 19th International Congress on Acoustics Seville, 10-12 September 2007. [5] P Virjonen, J Keränen, V Hongisto, Determination of Acoustical Conditions in Open-Plan Offices: Proposal for New Measurement Method and Target Values, Acta Acustica United with Acustica, Vol. 95 (2009) 278-290. [6] C M Petersen, Limiting Annoying Noise in Open- Plan Offices, Joint Baltic-Nordic Acoustics Meeting 2008, 17-19 August 2008, Reykjavik, Iceland. 4 Conclusions There is a need for complementary parameters for the acoustic evaluation of open-plan offices. Ordinary room acoustic parameters like reverberation time are not sufficient for a relevant characterization of the acoustic environment in open-plan spaces. The influence of the interior design on sound propagation over distance is a crucial factor for the overall impression of the acoustic environment and its suitability as an efficient work place. Measures related to sound propagation like DL2 and DLf are therefore appropriate for open-plan spaces. In two openplan offices a refurbishment program has been performed. It has been shown that DL2 and DLf are sensitive for the acoustic treatments carried out and also reflect the improvement of the subjective judgment concerning the acoustic environment in general. Moreover, these measures can be converted into a (comfort) radius indicating the distance needed to achieve a certain reduction of the sound level from a sound source. This application could serve as a practical tool for the acoustical planning of open-plan offices. [7] ISO 14257 Acoustics Measurements and parametric description of spatial sound distribution curves in workrooms for evaluation of their acoustical performance, 2001. Acknowledgments This project was partly financed by the Nordic Innovation Center which is greatly acknowledged.