Evacuation Policy for People with Special Needs

Similar documents
Guidance for writing a Personal Emergency Evacuation Plan (PEEP)

Fire Evacuation Procedure WISE Campus

EMERGENCY EVACUATION PLAN

PERSONAL EMERGENCY EVACUATION PLANS (PEEP s)

Fire Evacuation Procedure Stroud Campus

Fire Safety Personal Emergency Evacuation Plans Safety Guidance Note

Fire Evacuation Procedure WISE Campus

SHREWSBURY COLLEGE EMERGENCY PROCEDURES. Firearm and Weapon Attacks

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017

Reviewed: DD Month Emergency Evacuation of People with a Disability Options Matrix for Developing a PEEP

Fire Evacuation Procedure Berkeley Green, John Huggett Engineering Hall

Health and Safety Code of Practice. SCP37 Assisted Emergency Evacuation

Policy for Safe Evacuation of Persons with Disabilities

Fire Evacuation Procedure Filton Campus

Fire Safety Protocol

Fire Evacuation Procedure Stroud Campus

Charlotte Building, 17 Gresse Street, London W1T 1QL

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

DEF Fire Evacuation and Emergency Planning Criteria

EVACUATION PROCEDURES IN EDUCATION PREMISES

Annemount School Fire Safety Policy This Policy is for the whole school including the EYFS

EVACUATION POLICY 1. General

Personal Emergency Evacuation Plan (PEEP) Guidance and Plan

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

Fire Policy. Fire Safety Order (2005) Dangerous Substances and Explosive Atmospheres Regulations (2002)

Stationers Crown Woods Academy. Evacuation Chair. Policy

CORPORATE SERVICES HEALTH AND SAFETY

Summer Centre (Worcester Road): Social Programme Assistant, Stephen Taylor, ADOS

Wellsprings Primary School. Fire Emergency Evacuation Plan

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Appendix D. Emergency Evacuation for Persons with Disabilities

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire and Emergency Evacuation Procedures

SCHOOL EVACUATION POLICY

Crown Woods College. Fire Safety Policy

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Management Standard: Fire Safety

EMERGENCY EVACUATION PLAN

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

Invacuation, Lockdown and Evacuation Policy

EMERGENCY EVACUATION Can your staff evacuate your occupants safely?

EMERGENCY EVACUATION How prepared are you?

Kings Fire Safety Policy

Fire evacuation drill

PREMISES FIRE SAFETY HANDBOOK

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

Safety Note 28. Emergency Evacuation of Disabled People: Personal Emergency Evacuation Plans (PEEPs)

Fire Safety Policy Date: 0

Fire Evacuation Policy

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY

Upon activation of the building fire alarm system or verbal command to evacuate a building: All personnel shall evacuate the building immediately.

FP-PGN-14 Part of NTW(O)41 Fire Policy

NOT PROTECTIVELY MARKED. Fire Legislation

FIRE SAFETY POLICY Revised March 2013

Personal Emergency Evacuation Plan (PEEP) Procedure 2018 / 2019

Fire Safety Policy. Somerville College Woodstock Road Oxford OX2 6HD

GHS 8-4 Fire Policy and Procedures

LEICESTER GRAMMAR SCHOOL TRUST FIRE SAFETY POLICY

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

Fire Safety, Fire Procedures and Fire Risk Assessment Policy. Three Schools Policy

Health and Safety Performance Standard HSPS 012. Provision of Personal Emergency Evacuation Plans (PEEPs) (Fire Safety)

EMERGENCY EVACUATION How educated are you?

Fire Safety Management Policy. This plan should be read in conjunction with the Health and Safety Policy.

STATEMENT OF THE HEALTH AND SAFETY STRATEGY FOR THE SYDNEY RUSSELL SCHOOL

PREMISES FIRE SAFETY HANDBOOK

Excel English. Health & Safety Policy

EMERGENCY PROCEDURES

Personal Evacuation Egress Plan (PEEP) Reference Number AR-RMD-HSMS36 DOCUMENT HISTORY. 1.0 May Sept Jan-06 8.

Emergency Procedures for Persons Requiring Assistance in Evacuation

(Fire) Emergency Evacuation Plan

Fire Risk Management Policy. UK September 2017

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Fire safety procedure

Fire Safety, Procedures and Risk Assessment Policy

UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK. Regulatory Reform (Fire Safety) Order 2005 DARWIN BUILDING

EMERGENCY EVACUATION PROCEDURE Temporary Instructions w.e.f 5 th September 2018

Emergency Evacuation Plan

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Health and Safety Services. Safety Guide 5. Fire drills

EMERGENCY PREPAREDNESS: EVACUATIONS

Ruishton C of E Primary School

Fire Prevention and Procedures Policy

Whitley Abbey Primary School

Arbour House. Fire Policy and Procedures

FIRE SAFETY AND PREVENTION POLICY

Property Name & Address [ Property Name ] - [ Property Address ]

Peninsula Dental Social Enterprise (PDSE)

PREMISES FIRE SAFETY HANDBOOK

WARDEN TRAINING AT QUT

Evacuation of Mobility Impaired Persons. Staff News: New Fire Evacuation Policy and Procedures Important for all staff and students

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

Emergency Evacuation Procedures

NHSScotland Firecode Scottish Fire Practice Note 3 Version 3

Elutec Fire and Evacuation Procedure

Transcription:

Evacuation Policy for People with Special Needs Reviewed By David Neild Last Reviewed date Autumn 2016 Next Review Date Autumn 2017

Headlands School Evacuation Policy For People With Special Needs Arrangements in the Event of an Emergency for Persons with Special Needs Contents: Policy Statement Risk Assessment Planning an Evacuation Procedure Personal Emergency Evacuation Plans (PEEPS) Visitors with Special Needs Refuge Areas Techniques for the Evacuation of People with Special Needs Conclusions Policy Statement As a minimum the School arrangements and facilities will comply with the requirements of relevant legislation and Building Standards, including the Public Sector Equality Duty Act. The School will not permit individuals with special needs to be put at risk by permitting access to areas where insurmountable difficulties associated with egress in the event of an emergency would present an unacceptable risk to the health and safety of that individual or of other users of the building. The School will not seek to obtain personal information relating to an individual with special needs beyond that which may be reasonably required to make arrangements for their health and safety. Risk Assessment Passenger or goods / service type lifts must not be used in any emergency situation such as a fire. As a result it may be necessary to make other arrangements to allow individuals with special needs to evacuate a building. Assessment of the emergency egress from a building will be an integral part of the routine assessment of access that is made in respect of staff, students and visitors to the School. This will ensure that access provision is complimented by egress provision. This assessment may also be required prior to any formal offer of employment to prospective employees as well as in respect of the placement at the School of a student. The assessment process will be informed by data from a range of sources which may include: The nature and extent of the individual s special needs. The building fire risk assessments. Assessment of risk to the individual with a special need and other building users. Suitability and availability of alternative arrangements in other buildings. Where reasonably practicable, shortcomings in the facilities of a building will be brought to the attention of the PFI Service Provider and Asset Holder via Special Projects Office, East Riding of Yorkshire Council, in a bid to address them however, the design of the building may preclude this option. Existing areas of refuge (as defined in BS 5588-8:1999) will be identified and clearly marked as part of the building fire risk assessment. 2

Planning an Evacuation Procedure The following issues need to be considered when planning an evacuation for people with special needs: Identify the number of staff, students and visitors with special needs and where they will be in the building. Implement Personal Emergency Evacuation Plans (PEEPS). Consider the characteristics of the building. Assess the evacuation equipment people will need. Train staff to deal with emergency situations and evacuations. Determine what needs to happen when the alarm is activated. Identify what needs to be done when it is not possible to evacuate people with special needs. Personal Emergency Evacuation Plans (PEEPS) The purpose of a PEEP is firstly to ensure the safety of the named individual in a building evacuation situation. The PEEP will also record the safety plan, e.g. routes, corridors, stairs or refuges etc, as well as those persons who will assist and any training or practice needs. The School must produce a PEEP when it becomes aware that staff, students or visitors may experience difficulties in responding to a building emergency evacuation alarm. The School, through the Head of Year, SENCO (in the case of an SEN student) or other nominated member of staff, in conjunction with the Safety, Health & Environment (SHE) Manager, will prepare the plan in consultation with the individual member of staff or student. The School should ensure that the effectiveness of PEEPs and special evacuation procedures are tested during routine or planned fire drills. The arrangements that are in place should be reviewed in the light of feedback following the completion of the drills and the relevant PEEPs updated to reflect this. Updated versions of PEEPs are to be retained with the original version. During such review particular attention should be paid to any alteration of the fabric or layout of the building or the changing needs of the individual. Where there is no route by which a person with special needs can immediately exit a building unaided, the PEEP will identify suitable areas of refuge. In the event of the need to evacuate the building, people with special needs should, if necessary, be assisted to reach these areas. It is permitted for a member of staff, friend or carer to remain at the refuge area with them but is critical that the details of these persons are relayed to the relevant Assembly Point as soon as possible in order to maintain correct records of the whereabouts of individuals. In some cases the process of evacuation for a person with special needs may impede the evacuation of other building users. In these circumstances the individual, and any carer or friend should remain within the refuge area until the evacuation process has allowed other building users to clear the escape route. The PEEP should identify the preferred mechanism of evacuation from the refuge area. This may include the use of an evacuation chair (Evac+Chair). If a PEEP identifies a requirement for a person to be transported down stairs by means of an evacuation chair the School must ensure that those who provide this service have been suitably and sufficiently trained. All staff who could be expected to aid the evacuation of a person with special needs should receive a copy of the relevant PEEP. A PEEP should be activated immediately the alarm is sounded. 3

Visitors with Special Needs When a visitor with special needs attends the School they must report to Reception. The School, through the SHE Manager will have developed a generic evacuation plan and this should be handed to the visitor. It will be the responsibility of the School to ensure that in the event of an emergency that the individual is escorted to the refuge area and communication made with the member of staff supervising the evacuation. Refuge Areas Where staff, students or visitors with special needs are unable to use stairways without assistance, it will be necessary to identify refuge areas. Refuge areas provide a place of relative safety for persons before being assisted to a final exit from the building. With good communication links to the refuge area it may not be necessary to evacuate from the refuge area if the fire or other emergency does not pose a risk. Refuge areas can be an enclosure such as a compartment, lobby, corridor or stairway that can provide protection from fire. Once a refuge area has been identified it should be suitably signed and kept free from obstruction. It is essential that the location of a refuge does not have any adverse effect on the means of escape. Presently at Headlands School refuge areas on the first floor of the General Teaching Block (GTB) do not have means of communication linked to staffed areas such as Reception. The person with special needs friend, colleague or the most senior staff member present must find a way of reporting the presence of a person with special needs at the refuge point to Reception upon activation of the fire alarm in order that evacuation can be carried out. Techniques for the Evacuation of People with Special Needs Staff, students and visitors with a visual impairment may be guided on level surfaces by taking someone s arm and following. On stairways the guide should descend first and then the person following can place their hand on the guide s shoulder. If a member of staff or visitor is a guide dog user they should be asked about how / if they can be assisted. Many people with special needs will be able to descend or ascend stairs however, others may need some assistance. At Headlands School equipment, in the form of evacuation chairs to assist persons descend stairs are positioned on the first floor of the GTB and the first, second and third floors of the Tower Block. If it is safe to do so then wheelchairs, guide dogs and other mobility equipment (crutches etc) must be evacuated at the same time as the person. Conclusions The safe evacuation of staff, students and visitors with special needs is the responsibility of the School. Safe evacuation procedures and measures must be pre-planned to identify the needs of the person and to make proper arrangements for their assistance. A PEEP must be produced with the active participation of the affected person. Written instructions and where necessary, training, should be provided in ensuring that a PEEP is followed and that all relevant members of staff are aware of its existence. It may be necessary to phase vertical movement of the personnel using refuge areas and the use of properly designed evacuation equipment. There are minor modifications that can aid evacuation, e.g. ramps, colour contrasting stair nosings and handrails, visual or vibration alarms. Any modification to the building must be discussed with the SHE Manager and in due course the other stakeholders of the site. 4

It should be borne on mind that it is the responsibility of the School to ensure the evacuation of persons with special needs. Upon arrival of the Fire Brigade they will make their own dynamic risk assessment and dependant on their priorities may assist with evacuations. 5