NCU Mounting Details

Similar documents
ET10 Series Stand-alone LCD Fan Coil Thermostat

ETAF Series VDC Fan output LCD Fan Coil Thermostat

DAP III Zone Master User s Guide

Carbon Monoxide Transmitter

Networkable Fan Coil Controller Specification and Installation Instructions

Fan Coil Unit (FCU) Application Guide

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

I/O ZONE 560/583 USERS GUIDE

T6590 Series FAN-COIL CONTROLLER

CP CP

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Features. Fan coil units Fan, Pump control Ventilation Underfloor fans

T6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

P2267 NETWORK INTERFACE

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

Installation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

INSTALLATION & OPERATION MANUAL

XE99 SERIES FAN-COIL THERMOSTATS 2-PIPE & 4-PIPE FAN-COIL CONTROL FEATURES APPLICATION PRODUCT SPECIFICATION SHEET

NGC-40 Advanced Heat-Tracing Control System

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

B-40/B-41 Modulating Temperature Controller

Installation Instructions

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

Introduction. What is the W2W Open controller?

RCS Residential Control Systems Inc.

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

PIR Ready VT76xx Series Programmable & Non-Programmable Thermostats For Commercial HVAC Applications. BACnet Integration Manual September 1, 2010

1.0 Digital Controller

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

Public Safety DAS Annunciator Panel

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Unity Board Micro Air Corporation Phone (609) Route Allentown NJ Fax (609)

HeatNet Manual Control Adjustment and Operation Instructions for Hydrotherm Firmware Version 2.8

INSTALLATION & USER MANUAL

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

Product Manual SZ1009

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

LCF Touch Modbus Datasheet Application Security Advice Caution

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

NELSON CM HEAT TRACE CONTROLLER Installation and Operating Instructions

Table of Contents. WSHP Open v3

FPC-02 Series. Installation and Operating manual

VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors

1.0 Digital Controller

System Accessories, LCD Annunciators

TABLE B Remote Wire Connection

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Spartan Peripheral Devices. TE 256S Thermostat Applications

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

CLEANROOM MONITOR CR3A Network - Installation Instructions

Contents. Appendix E: LonWorks Protocol Implementation Conformance Statement Document revision history... 47

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

T170 Thermostat. Installation and Maintenance Manual. 24 VAC/ VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control

TEC BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control

Installation and Maintenance Manual IM

BB3000 Series. Application. Features. Injection Pump Control General Instructions

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

ACL TC 200 TEMPERATURE CONTROLLER

The CAB & DAB Air Curtains

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Installation and Maintenance Manual IM

OVEN INDUSTRIES, INC.

Control manual. Series. Gas-fired direct vent Cast iron boilers. Control adjustment and Operation instructions

Carbon Monoxide Transmitter

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

910 Series Single-point heat-tracing control system

Duct and Rough Service Carbon Monoxide Sensor

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

RCS Residential Control Systems Inc.

User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat

- Data Brochure Mixing Control 360

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

DMFPM-2R MULTIFUNCTIONAL

Table of Contents. Unit Ventilator

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

BACnet Integration Manual ITG-VH72xx-BAC-E00 ( _R0 Issue Date: October 21, 2008)

prestige Control Application Supplement - TriMax

TTSIM-1 Sensor Interface Module

Transcription:

Revision Date December 4, 2013 RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units Installation and Operation Instructions Dimensions in mm Power Control Unit Display Control Unit Remote Control Unit NCU Mounting Details Mounting of Network Control Unit The NT10 network control unit can be surface mounted or secured to a standard European 75 x 75 x 35 mm electrical box. See Fig. 2: Mounting Details. Two M3.5 mounting screws for Network Control Units only are included. 1

Network Control Unit and LCD Layout When the following errors are reported on the LCD display unit, these errors will prevent the thermostat from normal operation and all thermostat functions will be locked out: E-1 EEPROM read/write error E-2* Temperature sensor open-circuited E-3 Temperature sensor short-circuited E-4 User configuration checksum error Thermostat Errors Reporting * If jumper JP1 is cut open and external sensor is used, E-2 means the external sensor may have been disconnected from Terminals SR1 and GND. Check the external sensor s connectivity and resistive value. If E-2 error is still reported, return the thermostat to the manufacturer for repair. When the error E-1, E-3 or E-4 is reported or when the error E-2 is reported without jumper JP1 being cut and external sensor being installed, return the thermostat to the manufacturer for repair. Trouble-Shooting Before trouble-shooting starts, ensure that the voltage output from Terminals 1 (GND) and 2 (+5 Vdc) on the power supply unit is between 5 Vdc and 5.25 Vdc and not higher. Higher voltage may damage the internal circuitry and components of the network control unit. When abnormal power voltages are found, return the thermostat to the manufacturer for repair. When there is no 5 Vdc power output, check the line voltage power and its 5 A fuse. Operation Notes LCD shows ambient temperature constantly except when set point adjustment is being made. Press the system key Ф to enter into the desired operating mode: Cool-Heat-Auto-Fan Only-Off, etc. Press the fan key to change the fan speed mode: High-Med-Low-Auto. Increase or decrease temperature set point by rotating the adjustment dial clockwise or counter-clockwise. When the dial is rotated, the LCD shows the existing set point setting. In unoccupied mode, the factory temperature set points are 26 o C for cooling and 16 o C for heating and the fan speed is always set at low. Unoccupied mode can be activated in the following manner when the unoccupied contact closes: For Models 1, 1A and 1F, the unoccupied cooling or heating mode is determined by the status of the SR2 seasonal changeover sensor and the valve output is activated according to the measured temperature. For Models 1M, 1AM and 1FM, while in unoccupied mode, the valve output is never activated. For Model 2 and 2A, the unoccupied cooling or heating mode is always determined by the measured temperature and valve output is also activated according to the measured temperature. Unoccupied mode activation in operating mode only or in both standby and operating mode will be determined by activation setting in setup menu. Low fan will run according to fan action setting in setup menu. When unoccupied mode is activated, all keys are locked out and no settings can be entered. The thermostat allows authorized service agent to change the following operating parameters in the field: 2

MCU firmware revision level 0 Appears after entering the setup mode Choice of temperature engineering unit 1 1-C= ºC (factory setting) 1-F = ºF Choice to retain last entered settings on 2 2ON = program on (factory setting) power resumption 2OF = program off Offset adjustment of temperature indication 3 3 2 = temperature indication plus 2 degrees (field recalibration of measured temperature) 3 1 = temperature indication plus 1 degree 3 0 = no offset (factory setting) 3-1 = temperature indication minus 1 degree 3-2 = temperature indication minus 2 degrees Thermostat address setting 5 To set the slave device address from 1 to 32 Adjustable proportional band for PI control A Adjustable 1 to 10: A 1 = 1 K.A 3 = 3 K (factory setting)...a 5 = 5 K Adjustable integral time for PI control b To set integral time from 0 (0 min) to 30 ( 30 min) in numeric 1 (1 min ) increment factory setting = 15 minutes. Setting = 0 means integral time being turned off. Choice of valve stroke time for 3-wire floating models C Deadband adjustment for dual-output models d Upper occupied set point limit setting E Lower occupied set point limit setting F Unoccupied cooling set point setting Unoccupied heating set point setting Choice of fan action in unoccupied mode (always in auto fan mode) Choice of activation of unoccupied mode Choice of auto fan action in heating mode (operation of both control valve and fan is temperature-dependent) Choice of operating sequence for dual-output models only Choice of 1 or 1M model Choice of constant display of ambient temperature or temperature set point value Restoration of default factory settings G h Adjustable 1 to 24: C 1 = 10 seconds..c18 = 180 seconds = factory setting..c24 = 240 seconds To set deadband value from 1 to 5 K, factory setting 3 K To set upper occupied set point limit, adjustable between current lower set point limit value and 35 C (factory setting 35 C). The program is set such that there is always a minimum separation of 4 degrees maintained between the upper occupied set point limit value and the lower set point limit value. To set lower occupied set point limit, adjustable between current upper set point limit value and 5 C (factory setting 5 C). The program is set such that there is always a minimum separation of 4 degrees maintained between the upper occupied set point limit value and the lower set point limit value. To set unoccupied cooling set point, adjustable between current unoccupied heating set point value and 35 C (factory setting 26 C). The program is set such that there is always a minimum separation of 4 degrees maintained between the unoccupied cooling set point value and the unoccupied heating set point value. To set unoccupied heating set point, adjustable between current unoccupied cooling set point value and 5 C (factory setting 16 C). The program is set such that there is always a minimum separation of 4 degrees maintained between the unoccupied cooling set point value and the unoccupied heating set point value. J J-1 = Low fan will run only when unoccupied set point calls for cooling or heating in unoccupied mode (factory setting) J-2 = Low fan always runs whenever unoccupied contact is closed while opening and closing of control valve are temperature-dependent. L L-1 = Unoccupied mode can only be activated when thermostat is in operating mode ( factory setting) L-2 = Unoccupied mode can be activated when thermostat is in either standby mode or operating mode P P-1 = No fan output when room temperature (Tr) => set point value (Ts). Low speed when - 2.0 K <= Tr - Ts <= -0.5 K Med speed when - 4.0 K <= Tr - Ts <= -2.5 K High speed when Tr - Ts <= -4.5 K P-2 = (factory setting) Low fan output when -2.0 K <=Tr - Ts Med speed when - 4.0 K <= Tr - Ts <= -2.5 K High speed when Tr - Ts <= -4.5 K r r-1 = to set operating mode in sequence of Cool-Heat-Auto-Fan Only-Off (factory setting) r-2 = to set operating mode in sequence of Auto-Off t t-1 = to set operating mode in sequence of Off-Cool or Heat-Fan Only (factory setting for 1 model) t-2 = to set operating mode in sequence of Off-Cool-Heat-Fan Only (factory setting for 1M model) u u-1 = constant display of ambient temperature (factory setting) u-2 = constant display of set point value RS RS1 = Retain current settings (factory setting) RS2 = Restore default factory settings 3

Network Configuration To a BACnet MS/TP Network Supervisor BACnet MS/TP Network BACnet MS/TP Network Notes: 1. Ensure the recommended balanced cable is used. 2. Ensure the cable is installed as a daisy chain from one device to the next (1,000 m maximum) and the shield is grounded at one single point of the network only. 3. Ensure a MS/TP terminator is installed on each end of each MS/TP network. 4. The maximum nodes per MS/TP network is 32 without a repeater. BMG (Master) BMG (Master) RS-485 FClink ornetwork Slaves Modbus RTU Network Notes: 1. Ensure the recommended balanced cable is used. 2. Ensure the cable is installed as a daisy chain from one device to the next (1,000 m maximum) and the shield is grounded at one single point of the network only. 3. Ensure a terminator is installed on each end of each FClink network. 4. The maximum nodes per FClink network is 32 NT10 NT10 NT10 NT10 Network & Cabling Requirements To ensure network stability and reliable communications, particularly at high speeds on a BACnet MS/TP network for a number of devices, it is imperative that the following network and cabling requirements are adhered to: Item Cabling for Modbus RTU and BACnet MSTP networks Topology Maximum Nodes Terminator Description It is recommended to use networking cabling that matches the following specifications: Balanced 100 to 120 ohms nominal impedance, 22 or 24 AWG Twisted Shielded Pair (TSP) Cable Nominal capacitance of 52 pf/m or lower Nominal velocity of propagation of 66% or higher Terminating the shield to ground at one end only for each isolated segment will prevent ground loops in the shield and drain RF energy to ground. Grounding at the BACnet router or controller is preferred. Ensure the MS/TP and Modbus RTU network cable is installed as a daisy chain from one device to the next. The maximum number of devices is 32 per MS/TP network segment and 64 per network trunk with one repeater. A terminator of 120-ohm impedance must be installed at each end of each MS/TP network segment, or two per MS/TP network. Ensure that this requirement is not overlooked in laying out the network architecture and ordering product. Cable Shielding Use a shielded, twisted pair cable for communications. Never directly ground wire in more than one point on the shield. Doing so can induce large currents and result in communication problem. Repeater A repeater is not necessary unless more than 32 nodes will be installed on a network or the MS/TP network is extended beyond 1,000 m. Step-down Transformer A separate isolated double-wound transformer is recommended for supplying 24 VAC power to each BMG. If and when the same transformer is shared with other devices, observe the polarities of the power supply of all devices including the BMG. 4

Wiring Diagrams and Application Notes The networking thermostats consist of two basic units: the Network Control Unit and the Power Supply Unit. While all linevoltage wiring is terminated at the Power Supply Unit, all connections between Network Control Unit and Power Supply Unit are of low-voltage signaling wires. Wiring and Application Notes Cut jumper JP1 if external sensor is wired to SR1 and GND. Run the wiring away from any electrical motors or power wiring. Failure to do so may result in poor thermostat performance due to electrical noise. 22 AWG twisted shielded pair is recommended as remote sensor wiring and its length must not exceed 25 m. Do not bundle and run power wiring and remote sensor wiring in the same conduit. Connecting wires between Network Control Unit and Power Supply Unit must not exceed 15 m. Seasonal changeover sensor or switch is only applicable to heat only or cool only 2-pipe model only. The seasonal changeover sensor should be wrapped around the supply water pipe when associated with a water system. When the changeover sensor temperature exceeds 30 ºC, the thermostat enters into heating mode. Unoccupied contact closure activates energy saving mode. The thermostat outputs are designed for controlling zone valves. If used for controlling electric heaters, external contactors must be used. Wiring Diagram for Line-Voltage Fan and Line-Voltage 2-Wire On-Off Valve Outputs WARNING Incorrect wiring connection may cause permanent equipment damages to the thermostat. Piping Notes: 1. On a single-output unit, V1 can be a 2-wire cooling or heating valve. 2. On a dual-output unit, V1 must be a 2-wire cooling valve and V2 a 2-wire heating valve. 3. Hidden-line wiring for Terminals V2 and 6 are applicable to dual-output models only. RS485 communications wires: 22 AWG twisted shielded pair Inter-connecting wires: Cat 5e twisted 6-conductor cable (shielded or unshielded) Power wires: wire size 1 mm 2 or 18 AWG solid copper recommended 5

Wiring Diagram for Line-Voltage Fan and Single Line-Voltage 3-Wire Floating Valve Output WARNING Incorrect wiring connection may cause permanent equipment damages to the thermostat. Piping Notes: 1. V must be a line-voltage 3-wire floating valve. 2. In cooling mode, V1 output opens valve on temperature rise and V2 output closes valve on temperature drop. The action in heating mode is reversed. RS485 communications wires: 22 AWG twisted shielded pair Inter-connecting wires: Cat 5e twisted 6-conductor cable (shielded or unshielded) Power wires: wire size 1 mm 2 or 18 AWG solid copper recommended 6

Wiring Diagram for Line-Voltage Fan and 0-10 VDC Valve Outputs WARNING Incorrect wiring connection may cause permanent equipment damages to the thermostat. Piping Notes: 1. On a single-output unit, V1 can be a cooling or heating valve. 2. On a dual-output unit, V1 must be a cooling valve and V2 a heating valve. 3. Hidden-line wiring for Terminals V2 and 6 are applicable to dual-output models only. RS485 communications wires: 22 AWG twisted shielded pair Inter-connecting wires: Cat 5e twisted 6-conductor cable (shielded or unshielded) Power wires: wire size 1 mm 2 or 18 AWG solid copper recommended NT10-Ins-0, 13-12(Modbus RTU) 7