hinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 )

Similar documents
Installing the Vacuklav 40-B / 44-B

MELA dem Everything you need for water treatment

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Installation plan PG 8581 PG 8582 PG en - US

Operation Manual. Trash Water Pump ARTICLE Image similar

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

PJ130S High Pressure Cleaner

Technical Description. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

EL400 OPERATION MANUAL

WATER SOFTENER MODEL 801 CODE

Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

Installation plan: PG Mat. no Version 00 US

Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr

INSTALLATION INSTRUCTIONS DÜRR MOTORSEPA S 300

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

PRE-INSTALLATION PROCEDURE

CEILING FAN OWNER'S MANUAL

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

CEILING FAN OWNER'S MANUAL

Customer Requirements Pre-Installation Instructions

Mounting and Operating Instructions EB 2231 EN

Operating Manual JuniorPower

INSTALLATION AND INITIAL OPERATING INSTRUCTIONS

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

DV Even higher and wider

APW-VAP-150P High Pressure Cleaner Operator Manual

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Model KBWF 240 Growth chambers with light and humidity

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Data sheet: Wilo-RainSystem AF Comfort MC 304

Storage tank size Rated volume [l] Actual volume [l]

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Installation manual. Tumble dryers T4130. Compass Control

CEILING FAN OWNER S MANUAL

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Local Air Conditioner

Site Requirements. MODEL 2.0 Australia

Operating Instructions

Installationsplan / Installation plan PW 6161 EL

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Settings and Maintenance of the CombinAir

CEILING FAN OWNER'S MANUAL

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Design Guide 2014 Fully Integrated Models 24" and 48"

Manual. Above-counter dispenser for hot drinks OTHG /12

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.

Installation Instructions Wall Ovens

SCHWAN INSTALLATION GUIDE

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

Ceiling Fan Ow n e r s Manual

BioMaster 250/350/600 BioMaster Thermo 250/350/600

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

Please read the following installation instructions first after purchasing this product or transporting it to another location.

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

K20 K40 ICEMAKER INSTRUCTIONS

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Electrisaver User and Installation Instructions

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

DISPOSER CONTROL CENTER

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

INSTALLATION MANUAL. Auto Clean Rotisserie. ACR on underframe

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

NO PRE- WASHING CONCEPT

Site Requirements ADVANTAGE PLUS

ROBOTIC CLEANER. TigerShark / TigerShark QC / TigerShark 2

Operating instructions

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

User Manual. Vacuklav 24 B/L+ Steam sterilizer. as of software version Dear Dr.

Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

READ AND SAVE THESE INSTRUCTIONS

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Unvented Electric Water Heater 10/15 litre Undersink

Documentation guide to get your plant on the positive list (Category A1/A2)

UFM-T100H US ES CA Power Alarm Test TM

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

DOUBLE DISHDRAWER TM DISHWASHER

UV Flame Supervision System

Outdoor Beverage Center

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan

Cable Drum Machine. Operation Manual 110ES SERIES. Cleans 1 1/4" to 3" lines up to 25'

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

SensaGuard TM Integrated Latch Installation Instructions

Friwa Compact. Operating instructions EN

62" LED SPYRA. Product images may vary slightly from actual product. INSTRUCTION MANUAL

Operating Instructions for Fristam Powder Mixer

Transcription:

Space requirements Fig. 1: Fore view, door hinge left Fig. 2: Upper view, door hinge left (D1, D2) and door hinge right Table 1: Space requirements Cliniclave 45 Dimensions Cliniclave 45 Width Height Height with floor unit Free area below the swivel range of the door Depth A 65 cm B 1 85 cm + 6,5-7 cm max. height of the device feet B 2 160 cm B 3 85 cm C 91 cm Minimum clearance to the door hinge side* D 1 25 cm (with a minimum opening angle of 95 ) Minimum clearance to the side wall of the floor unit D 3 8 cm Minimum clearance to rear Free area (corresponds to the free room with a fully-opened floor unit door) D 2 75 cm (with a maximum opening angle of 170 ) E 15 cm F 1 80 cm (with a minimum opening angle of 95 ) F 2 70 cm (with a maximum opening angle of 170 ) Total required niche width G 1 min. 98 cm (with an opening angle of 95 ) G 2 min. 148 cm (with an opening angle of 170 ) Clear width from the practice entrance to the min. 70 cm installation location *) For devices with door hinge right maintain the distances mirror-inverted (dotted line) A free area of 60 cm must be given each side of the autoclave/must be achievable by moving the autoclave to facilitate maintenance. Additional space requirement for the reverse osmosis unit (only Cliniclave 45) For devices without a floor unit, a corresponding amount of space must be left for the reverse osmosis unit. It can be attached to a wall under the table if necessary. It is necessary to guarantee free access of the autoclave hoses and cables to the reverse osmosis unit. Reverse osmosis unit Width Height Depth MELAdem 56 52 cm 50 cm 20 cm Pressure tank for the MELAdem 56 35 cm 35 cm 50 cm Rev.: 2 15/0122 1

Fig. 2: Fore view, door hinge left Fig. 2: Upper view, door hinge left (D1, D2) and door hinge right Table 2: Space requirements Cliniclave 45 M Dimensions Width A 65 cm Height Height with floor unit Free area below the swivel range of the door Cliniclave 45 M B 1 85 cm B 2 160 cm B 3 85 cm Depth C 153 cm Minimum clearance to the door hinge side* D 1 25 cm (with a minimum opening angle of 95 ) Minimum clearance to the side wall of the floor unit D 2 75 cm (with a maximum opening angle of 170 ) D 3 8 cm Minimum clearance to rear E 15 cm Free area (corresponds to the free room with a fully-opened floor unit door) F 1 145 cm (with a minimum opening angle of 95 ) F 2 135 cm (with a maximum opening angle of 170 ) Total required niche width G 1 min. 98 cm (with an opening angle of 90 ) Clear width from the practice entrance to the installation location G 2 min. 148 cm (with an opening angle of 170 ) min. 70 cm Required corridor width When turning a 90 corner the sum of the door width and corridor width amounts to at least 2.30 m *) For devices with door hinge right maintain the distances mirror-inverted (dotted line) A free area of 60 cm must be given each side of the autoclave/must be achievable by moving the autoclave to facilitate maintenance. 2 Rev.: 2 15/0122

Installation location Property Cliniclave 45 Cliniclave 45 M Floor space required Floor loading during normal operation Floor loading during water pressure test level and horizontal 240/320 *) kg 60/80 *) kg per caster 320/400 *) kg 80 kg/100 kg per caster 460 kg 115 kg per caster 610 kg 152.5 kg per caster Heat emission up to 1.4 kw up to 2 kw (when door open) Ambient temperature 5-40 C (ideal range 16-26 ) sufficient ventilation of the room must be guaranteed Air humidity in % 30-60% Illumination in accordance with DIN EN ISO 12100 and DIN EN 1837 *) with floor unit Siphon with extension pipe 3) 3) 2) A Connection range for the cold water inflow hose to the siphon 1) Data applies in case of using the extension pipe (siphon and extension pipe are included in the installation kit) 2) The extension pipe can be cut to the required length. 3) The backflow preventer is only valid in the Netherlands. Fig. 3: Installation requirements (dimensions in mm) Rev.: 2 15/0122 3

On-site installation requirements Mains supply DANGER! Incorrectly performed electrical connections can result in a short-circuit, fire, water damage and/or an electric shock. This could result in serious injury. The connections for electrical provision and water supply and discharge must be set-up by trained personnel. Observe the information regarding the installation and commissioning provided in the technical manual. Observe the following safety measures when dealing with the cable and mains plug: Never splice or change the power cable. Never bend or twist the power cable. Never remove the plug by pulling on the power cable. Always take a grip on the plug. Never place any heavy objects on the power cable. Never run the cable over areas in which it could become trapped (e.g. doors or windows). Never lead the cable along a source of heat. Never use any nails, paper fasteners or similar objects to fix the cable. Should the cable or plug become damaged, switch off the autoclave. The power cable and plug should only be replaced by authorized personnel. Failure to observe these provisions can result in damage to the cable or plug and/or a fire or an electric shock. This could result in serious injury. Table 3: On-site installation requirements for electrical connection On-site installation requirements Cliniclave 45 Cliniclave 45 M On-site requirements Electrical equipment must accord with DIN VDE 0100. A main switch (all-pole) should be fitted outside the installation room. This must be marked as the device and easily accessible for the operator. The feed line to the electrical connection must be laid separately from the distribution to the device. Observe the clockwise rotating field! Electrical connection CEE socket with 380-415 V 16 A, separate electricity circuit with 3x 16 A fuse (to ensure continued practice operation following an autoclave malfunction), an additional RCD switch with 30 ma, 3N AC 380-415 V, 50/60 Hz, 3x16A Observe the clockwise rotating field! Electrical power max. 10.5 kw max. 13.5 kw CEE socket with 380-415 V 32 A, separate electricity circuit with 3x 32 A fuse (to ensure continued practice operation following an autoclave malfunction), an additional RCD switch with 30 ma, 3N AC 380-415 V, 50/60 Hz, 3x32A Observe the clockwise rotating field! Length of power cable Leak detector water stop) 2.3 m (1.6 m when using a floor unit) 1.8 m from the floor unit additional 230 V, 50 Hz socket 4 Rev.: 2 15/0122

Water connection Table 4: Requirements for water connection Cliniclave 45 Cliniclave 45 Cold water Feed water Waste water Length of water hoses 2.20 m (1.30 m from floor unit) n/a 1.50 m (1 m from floor unit) Connection in practice to the cold water cut-off valve (water inflow tap) G 3/4 to a reverse-osmosis unit, e g. MELAdem 56 to the surface-mounted siphon in the installation package Installation height 55-65 cm n/a max. 55 cm (upper edge of the siphon) Min. flow pressure 1.5 bars at 8 l/min. 0.5 bars at 5 l/min. n/a Recommended flow pressure Maximum water pressure (static) Additional requirements Water quality 2.5-6 bars at 8 l/min. 2-4 bars at 5l/min. 10 bars 5 bars n/a potable water, max. water hardness 4-12 dh in accordance with DIN EN 285 1) with MELAdem 56 Other water treatment units additional protection required in accordance with DIN EN 1717, fluid category 5 in accordance with DIN EN 285, appendix B table B.1, max. 5 µs/cm Leak monitor We recommend the installation of a leak detector with a cut-off valve (e. g. MELAG water stop) 1) Higher levels of hardness necessitates the installation of a water-softening unit. Rev.: 2 15/0122 5

Table 5: Requirements for water connection Cliniclave 45 M Cliniclave 45 M Cold water Feed water Waste water Length of water hoses 1.30 m from the floor unit n/a 1 m from the floor unit Connection in practice to the cold water cut-off valve (water inflow tap) G 3/4 to a reverse osmosis unit, e g. MELAdem 56 M to the surface-mounted siphon in the installation package Installation height 55-65 cm n/a max. 55 cm (upper edge of the siphon) min. flow pressure 1.5 bars at 8 l/min. 0.5 bars at 5 l/min. n/a Recommended flow pressure Maximum water pressure (static) Additional requirements 2.5-6 bars at 8 l/min. 2-4 bars at 5l/min. 10 bars 5 bars n/a with MELAdem 56 M Other water treatment units additional protection required in accordance with DIN EN 1717, fluid category 5 Water quality potable water, max. water hardness 4-12 dh in accordance with DIN EN 285 1) in accordance with DIN EN 285, appendix B table B.1, max. 5 µs/cm Leak monitor We recommend the installation of a leak detector with a cut-off valve (e. g. MELAG water stop) 1) Higher levels of hardness necessitates the installation of a water-softening unit. PLEASE NOTE The waste water hose must be fitted at a constant incline without sagging. Deviations in the installation arrangements require consultation with MELAG. Failure to do so can result in autoclave malfunctions. 6 Rev.: 2 15/0122