Design and Fabrication of Water Refrigeration System by Creating Vacuum

Similar documents
Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Performance Assessment of Water Cooled Condenser Refrigeration System

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

Design of LPG Refrigeration System

COMPRESSOR LESS SOLAR REFRIGERATOR

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Chapter 10. Refrigeration and Heat Pump Systems

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

CHAPTER 1 INTRODUCTION

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Thermodynamics II Chapter 5 Refrigeration

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

UEE11 Electrotechnology. Training Package. UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants SAMPLE.

Refrigerants Type Expensive Coefficient of Performance Toxic

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

Chapter 11 REFRIGERATION CYCLES

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Design of an Air Cooled Telephone Booth Using Solar Energy as Non-Conventional Energy Source

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Presentation on HVAC: Heating Ventilation Air Conditioning

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

LECTURE-18 Vapour Absorption Refrigeration System

DESIGN AND FABRICATION OF THERMOELECTRIC COOLER CUM HEATER

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

Chapter 11 REFRIGERATION CYCLES

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

REFRIGERATION AND AIR CONDITIONING

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

CHAPTER 1 INTRODUCTION

Thermodynamics I. Refrigeration and Heat Pump Cycles

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

A Comparison Between Refrigerants Used In Air Conditioning

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Oyelami S., Bolaji B. O.

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

INDIAN INSTITUTE OF TECHNOLOGY ROORKEE NPTEL NPTEL ONLINE CERTIFICATION COURSE. Refrigeration and Air-conditioning. Lecture-16 Refrigerants-1

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Design & Fabrication of Hybrid Cooler

Fabrication of Hot and Cold Water Dispenser

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Refrigerator and Heat Pump Objectives

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Study of Behavior of Refrigerant Mixtures in Domestic Refrigerator- Practical Research

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

η second law = Second law efficiency

Enhancement of COP in Vapour Compression Refrigeration System

Chapter 2. Alternatives to HCFCs and their Characteristics

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

International Journal of Advance Engineering and Research Development

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Evaluation of COP in Refrigeration System by using Different Refrigerants

Design and Development of Modified Air Cooler and Storage System

11/22/2014. (c) DR.A.M.SURENDRA KUMAR

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Modified Air Cooler with Split Cooling Unit

Performance Improvement of Window Air Conditioner by using Bottle Neck Arrangement

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

VORTEX TUBE REFRIGERATION SYSTEM BASED ON COMPRESSED AIR

MODERN EVAPORATIVE COOLER

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV

A Review Paper on Extracting Waste Heat from the Engine Exhaust and Reutilizing in Car Air Conditioning

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

REFRIGERATION AND AIR CONDITIONING

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Chapter 10 Lyes KADEM [Thermodynamics II] 2007

R07. Answer any FIVE Questions All Questions carry equal marks *****

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

Evaluation of Available Heat at the Exhaust of Automotive Engine for Air Conditioning by Vapor Absorption System

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

SOLAR POWERED AIR CONDITIONING

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

Transcription:

Design and Fabrication of Water Refrigeration System by Creating Vacuum R.Sam Sukumar 1, Dr.A.Gopichand 2, U.Janardhana 3, V.Satish Kumar 4, B.Veera Chanti 5 Associate Professor, Department of Mechanical Engineering, Swarnandhra College of, Narsapur, West Godavari Dist., Andhra Pradesh, India 1,2 U.G.Students, Department of Mechanical Engineering, Swarnandhra College of, Narsapur, West Godavari Dist., Andhra Pradesh, India 3,4,5 ABSTRACT: Today s refrigeration and air conditioning systems have become necessary for the human. In those refrigeration systems we are using different refrigerants for providing refrigeration effects. Indirectly those refrigerants are causing many effects, by emitting harmful gases to the surroundings. Gases like chlorofluorocarbons are affecting the atmosphere and causing ozone depletion. Therefore eco-friendly refrigeration systems are needed to reduce the pollution caused by the conventional refrigeration systems. The working of present system is a combined principle of steam jet refrigeration system (Present) and earthen pot cooling technique (Ancient). Vacuum pump is connected to the flash chamber, there by the total air can be removed in the flash chamber and vacuum is created. Due to the vacuum the water boiling point reduces and water starts evaporated by taking latent heat from water itself. There by the water cooled to low temperatures, that chilled water is used for air conditioning purpose. KEYWORDS: Refrigeration, Vacuum, Cooling, Water. I. INTRODUCTION Refrigeration may be defined as the process of achieving and maintaining a temperature below that of the surroundings, the aim being to cool some product or space to the required temperature. One of the most important applications of refrigeration has been the preservation of perishable food products by storing them at low temperatures. The subject of refrigeration has evolved out of human need for food and comfort, and its history dates back to centuries. The history of refrigeration is very interesting since every aspect of it, the availability of refrigerants, the prime movers and the developments in compressors and the methods of refrigeration all are a part of it. There are two types of refrigeration systems, one is natural refrigeration system and the other one is artificial refrigeration system. Natural refrigeration is sub divide into Art of ice making by nocturnal cooling, evaporative cooling, cooling by salt solutions. Artificial refrigeration is sub divided into Vapour Compression Refrigeration Systems, Domestic refrigeration systems, Air conditioning systems, Vapour Absorption Refrigeration Systems, Solar energy based refrigeration system, Gas Cycle Refrigeration, Steam Jet Refrigeration System, Vortex tube systems, Thermoelectric Refrigeration Systems[1-3,5-7]. The most common types of refrigerants in use nowadays are Halocarbons or Freon s, Azeotropic refrigerants, Zeotropic refrigerants, Inorganic refrigerants like carbon dioxide, ammonia, water and air, Hydrocarbon refrigerants. Our old air conditioner, freezer, refrigerator have a common problem. They all contain a chemical compound called chlorofluorocarbons or CFC s, a substance that adversely reacts with the ozone layer in the atmosphere. This substance is so harmful that special equipment and strict regulations were designed to protect the population of the entire planet. In 1974, studies began to show the effects of chemicals on the ozone layer. It was discovered that a particularly hazardous chemical, chlorofluorocarbons (CFCs), was creating damage to the ozone at an extremely fast rate. CFCs were commonly used as aerosol propellants in sprays and refrigerants in appliances like refrigerators and air conditioners. However, when chemicals, like CFCs, were released into the air, they would often reach the stratosphere Copyright to IJIRSET DOI: 10.15680/IJIRSET.2015.0404044 2428

and catalytically breakdown the ozone. These chemicals started eating away at the ozone, like wearing out an old sweater until holes formed. Due to these research findings, in 1978, the use of CFCs as aerosol propellants, such as in hairsprays and deodorants, was banned in the US. As scientists continued to study the ozone layer and the negative effects of chemicals on it, ozone holes were discovered. Above Antarctica and the South Pole as well as above the northern United States up to the North large holes have been appearing. Chlorofluorocarbons, commonly referred to as CFCs, are non-combustible liquids that were, at one time, frequently used as refrigerants and aerosol propellants, as well as for cleaning products. Since scientists discovered CFCs caused the depletion of the ozone layer, CFCs have been phased out, but old refrigerators and other devices that use CFCs might still be in use. Through inhalation, digestion or other physical contact, as well as from exposure to harmful levels of ultraviolet rays, CFCs can have a negative impact on human health [8-9]. II. CONCEPT AND WORING PRINCIPLE BASIC PRINCIPLE: The boiling point of a liquid changes with change in external pressure. In normal conditions pressure exerted on the surface of any liquid is the atmospheric pressure. If this atmospheric pressure is reduced on the surface of a liquid by some means, then the liquid will start boiling at lower temperature, because of reduced pressure. This basic principle of boiling of liquid at lower temperature by reducing the pressure on its surface is used in vacuum refrigeration system. The boiling point of pure water at standard atmospheric pressure of 760mm hg (1.013 bar) s 100 0 c. It may be noted that water boils at 12 0 c if the pressure on the surface of water is kept at 0.014 bar and at 7 0 c if the pressure on the surface of water is 0.01bar [4]. WORKING PRINCIPLE: Fig 1 shows the basic working of this system is that a vacuum pump is connected to the closed flash chamber, from doing that we can remove the total air in the chamber and create vacuum. Due to the vacuum the water boiling point reduces and water starts evaporated by taking latent heat from water itself. Evaporated water goes out in the form of water vapours. There by the water cooled to low temperatures, that chilled water is used for air conditioning purpose. Fig. 1 Working principle of water refrigeration system by creating vacuum WORKING: The schematic representation of the water refrigeration system by creating vacuum is shown in fig.2. The main working starts with filling the flash chamber with water up to a volume of 75% of the total volume. After the blower pipe is connected to the flash chamber inlet steel pipe, then the blower is started to run. Blower creates vacuum in the chamber by doing that the water boiling point reduces and water starts evaporated by taking latent heat from water itself. Evaporated water goes out in the form of water vapours. Then we achieve a temperature drop of the water in the flash chamber. The cooled water is released in to the storage tank by the operating tap, thus the total cooled water is removed from the flash chamber. From the storage tank the water is passed to the air cooler through a connecting pipe which gives cooled water on to the air cooler mesh the water is flowed through the mesh at the same time the cooler is ON by Copyright to IJIRSET DOI: 10.15680/IJIRSET.2015.0404044 2429

the working of the cooler it absorbs the cooling from the water and through the fan and it gives cooling effect to the surroundings which it was placed. The water which is passed through the mesh is stored in the air cooler itself which it is provided with a storage space. A pump is placed in the storage space, in order to pump the water to the flash chamber. Thus the used water can be used again by recirculating it to the flash chamber. Fig. 2 Schematic representation of water refrigeration by creating vacuum III. COMPONENTS REQUIRED The following components are required for making the refrigeration system. 1. Blower 2. Flash chamber 3. Storage tank 4. Air cooler Blower: This is the most basic and important component of this system. The vacuum created in the flash chamber is by means of this blower.a blower can be a vacuum pump, a vacuum cleaner or simply a blower. This blower is connected to the flash chamber for creating vacuum. This vacuum creates low pressures which lead to the drop in boiling point of the water. Fig.3 Blower Flash Chamber: Flash chamber is made up of stainless steel material. We made two holes in the upper portion of the chamber, one hole is welded with a steel pipe for the pupose of connecting the vacuum pump hose pipe and the other hole is made for fixing a plastic pipe which is the outlet of the air cooler. Another hole is made to the wall lower portion for fixing a operating tap, a plastic pipe is connected to the tap inorder to make a connection between flash chamber and the storage tank. It is highly insulated with the asbestos powder. Insulation is made in order to control the heat transfer to the surroundings. As we are producing cooling effect in the flash chamber the cooling effect sholud not be lost to the surroundings. Copyright to IJIRSET DOI: 10.15680/IJIRSET.2015.0404044 2430

Fig. 4 Flash Chamber Storage Tank:A thermocol box is used as a storage tank. The main purpose of using this tank is to have storage of cooled water which is produced in the flash chamber. Inlet of the flash chamber is connected to the outlet of the flash chamber. Also a hole is made in the bottom area of the storage tank which is connected with a plastic pipe, which is the inlet connection to the air cooler. Fig. 5 Storage Tank Air Cooler: A potable air cooler is used in this experiment. The cooler consists of a mesh, a motor connected to an intake fan. Also there is a pump exist in the water storage area for re circulating the used water. The actual design is changed to the requirement of the experiment. The connecting pipe between the pump and mesh upper part is removed, a pipe is connected to the pump out let and flash chamber inlet, by doing that the used water is re circulated in to the flash chamber. Fig.6 Air cooler Copyright to IJIRSET DOI: 10.15680/IJIRSET.2015.0404044 2431

Fig.7 Fabricated model of water refrigeration system by creating vacuum IV. CALCULATIONS Coefficient of performance: C.O.P=Refrigeration Effect/Work Done = h 2 h 1 /Work Supply = h 30 0 c h 20 0 C / Power Supplied to Vacuum Pump h 2 = At Temperature of 30 0 c=125.7kj/kg h 1 = At Temperature of 20 0 c=83.9kj/kg Work supply=800watts C.O.P = 125.7-83.9/800 C.O.P = 0.05 Critical radius of insulation: Thermal conductivity of plaster of Paris (K) = 0.17w/m.k Critical radius (RC) = K/H0 Where H 0 = 20w/m 2 (Assumed value) K = 0.17w/m.k = 0.17/20 = 8.5X10-3 R C 9 mm Actual diameter (R 1 ) = 165mm Outer diameter (R 2 ) = 176mm Insulation diameter = 11mm Critical radius of insulation R 2 >R C Therefore the sufficient insulation is provided to control the heat loss to the surroundings. Copyright to IJIRSET DOI: 10.15680/IJIRSET.2015.0404044 2432

Fig. 8 Graphical representation of temperature drop with respect to time for the water refrigeration system Fig 8 represents the graphical view of the temperature drop with respect to the time. By this graph we can analyse the result that the temperature of the water reduces with respect to the running time of the blower. Time Intervals (Min) Temperature Drop ( 0 C) 0 30 15 28 30 25 45 22 60 20 Table. 1Tabular representation of temperature drop with respect to time intervals The above table is drawn according to the readings obtained by running the experiment for 1 hour, the temperature is measured by using the thermometer. V. CONCLUSION Refrigeration systems by creating vacuum have been fabricated. Various tests were conducted on the system and the results were obtained. With the results obtained we came to a conclusion that efficiency of the system will be high at a pressure drop of 0.023 bar gives a temperature drop up to 200C. The temperature of water is reduced about 100C. This project is not confined for application chosen, but this is an experiment which helps the atmosphere by eliminating the air pollution. It is purely Eco Friendly. REFERENCES [1] S.P.Arora and Domakunduwar,A Course on Refrigeration and Air Conditioning, 8thEditionDhanpat andrai Publications. [2] R.K.Rajput, Thermal Engineering, 8th EditionLaxmi Publications. [3] D. S. Kumar,Thermal Science and Engineering, S. K. Kataria& Sons. [4] R.S.Kurmi,J.K.Gupta, T.B of Refrigeration and Air Conditioning, 5th Edition. S.Chand Publications. [5] Lesson number 1: History of Refrigeration, Version 1 ME, IIT Kharagpur [6] C.P.Arora, Refrigeration and air conditioning,2nd Edition [7] Refrigeration-Wikipedia, the free encyclopediahttp://en.wikipedia.org/wiki/refrigeration [8] Chlorofluorocarbon- Wikipedia, the free encyclopediahttp://en.wikipedia.org/wiki/chloroflurocarbon [9] http://www.ecoevaluator.com/environment/air-quality/chlorofluorocarbons-silent-destroyers-of-the-ozone-layer.html Copyright to IJIRSET DOI: 10.15680/IJIRSET.2015.0404044 2433

BIOGRAPHY [1] R.Sam Sukumar M.Tech. (Ph.D.), Completed B.E Mechanical Engineering at S.R.K.R Engineering College, M.Tech at JNTU-Anantapur, Pursuing Ph.D. at JNTU-Kakinada. 8 Years of teaching experience. [2] Dr.A.Gopichand M.Tech. Ph.D., 18 Years of teaching experience, Published 25 International Journals, Active member in different professional societies. [3] U.Janardhana, Completed Diploma in Mechanical Engineering at ShiridiSai Diploma in Engineering & Technology, Pursuing B.Tech at Swarnandhra College of Engineering & Technology. [4] V.Satish Kumar, Completed Diploma in Mechanical Engineering at ShiridiSai Diploma in Engineering & Technology, Pursuing B.Tech at Swarnandhra College of Engineering & Technology. [5] B.VeeraChanti, Pursuing B.Tech Mechanical Engineering at Swarnandhra College of Engineering & Technology. Copyright to IJIRSET DOI: 10.15680/IJIRSET.2015.0404044 2434