COMPLIANCE INSPECTION CHECKLIST. Date: 5/14/2011 Time In: 12:30PM Time Out: 1:00PM

Similar documents
Emis. Unit Description:

COMPLIANCE INSPECTION CHECKLIST. Date: 12/20/12 Time In: 1:00PM Time Out: 1:30PM

Subpart M National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities

NACT 287 Dry Cleaning

AIR POLLUTION CONTROL REGULATION NO. 23 CONTROL OF PERCHLOROETHYLENE EMISSIONS FROM DRY CLEANING OPERATIONS. Promulgated December 2, 2003

Airborne Toxic Control Measure for Emissions of Perchloroethylene from Dry Cleaning Operations

Perchloroethylene in Dry Cleaning

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Instructions and Resource Manual for the Dry Cleaner Compliance Calendar

San Joaquin Valley Air Pollution Control District

Subject: Notification of Petroleum Dry Cleaning Machine Installation (SUN - 175)

State of New Jersey. General Permit. for Degreasing Operations using Non-HAP Volatile Organic Compounds (VOCs)

Union County Vocational - Technical Schools Scotch Plains, New Jersey

1997 Edition. Clearing the Air on Clean Air: Strategies for Perc Drycleaners Compliance Risk Reduction Pollution Prevention

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

Guidance Document for the Halogenated Solvent Cleaner NESHAP - Forms Only Version

Refrigerant Management Requirements Update

APPENDIX 112D. PERCHLOROETHYLENE DRY CLEANING NESHAP (40 CFR 63 Subpart M) CAA SECTION 112 NESHAP

Small Business Assistance Program Metal Finishers Compliance Checklist

User s Information Manual

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Preventative Maintenance Tables

PLP - TERMS AND CONDITIONS Philadelphia Gas Works Residential Parts & Labor Plan Contract

Ammonia Detection System Codes and Design Specifications

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

ALABAMA Propane Gas Association

SOLVENT CLEANING OPERATION EQUIPMENT SUMMARY FORM-44 Page 1 of 7

COMcheck Software Version Review Mechanical Compliance Certificate

Indirect gas-fired air heater

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

Warranty Registration

CxA to Answer this Section

City of Duluth Festival Center 04/25

Revitalize Building Mechanical Systems (4619)

Z!i PA. Perchloroethylene Dry Cleaning Facilities - General Recommended Operating and Maintenance Practices for Dry Cleaning Equipment

Field Start-Up Sheet Direct Fired Gas Equipment

Diocese of Cleveland Facilities Services Corporation

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

SOP SF SOP for LN2 Freezers

Executive Summary

5.07 Air Replenishment Systems

User s Information Manual

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Climate Control System

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

AUSTIN FIRE DEPARTMENT SIA PROCEDURES FOR ANNUAL TESTING OF BUILDINGS WITH STAIRWELL AND VESTIBULE PRESSURIZATION SYSTEMS

Solvent Mileage. Government Involvement. Introduction. Increased Profit. Calculating Solvent Mileage. When to Calculate

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Lifestyle Selling = Consumer Choices

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

SECTION SAMPLE SPECIFICATION FOR BOILER CONTROLLER CONVERSION KIT

Ozone Depleting Substances (ODS) Rule Updates

Indiana WX Oil Furnace Inspection Guide

Boiler MACT Webinar Q/A

Part I Extraction Process Equipment

Photo courtesy of U.S. Navy. ARID-Dry. Restoration and Construction Drying Equipment Mobile Desiccant Dehumidifiers Temporary Humidity Control

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

THE CLEAR CHOICE FOR CLEANING

TABLE OF CONTENTS. Part I Administrative... 1

OPERATING AND MAINTENANCE MANUAL

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR

STEP 1: SELECT A NITROGEN GENERATOR STEP 2: SELECT A VENT STEP 3: SELECT MONITORING EQUIPMENT STEP 4: CONTACT ECS

HERS Verified Single Dwelling Unit Hot Water System Distribution (Page 1 of 6)

15900 HVAC INSTRUMENTATION AND CONTROLS

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

D-TEK Select. Refrigerant Leak Detector

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

COMcheck Software Version Mechanical Compliance Certificate

Elite. User s Information Manual. Elite and Elite VWH* All Models

TrueAlarm Analog Sensing

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

User s Information Manual

Field Adjuster s Evidence Submission Checklist General Info All Claims

THERMAX Efficiency Monitor

What is Included with a Seasonal Service?

Prescriptive Program Rebate Application

User s Information Manual

Montana Weatherization Program WEATHERIZATION FINAL INSPECTION REPORT (Mobile Homes) Client Name Address Contact phone # Inspector Name and QCI#

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Natural Gas & Propane Burners

IQ/OQ Protocol Installation Qualification/ Operation Qualification

Winnipeg Fire Department Fire Prevention Branch

Take The Test! Does Your Boiler Meet Code?

User s Information Manual

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

ICC CODE CORNER 2012 IFC Code & Commentary

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

YEARLY VIEW. 6/28/2016

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Michigan State University Construction Standards COMMISSIONING OF FIRE ALARM SYSTEMS PAGE

USER S MANUAL LINCOLN PF Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

b.) Technical Information:

FACTORIES ORDINANCE (CAP.

Transcription:

1030459 75790 PERCHLOROETHYLENE DRY CLEANERS COMPLIANCE INSPECTION CHECKLIST INSPECTION TYPE: ANNUAL (INS1, INS2) COMPLAINT/DISCOVERY (CI) RE-INSPECTION (FUI) ARMS COMPLAINT NO: AIRS ID#: 103 0459 Date: 5/14/2011 Time In: 12:30PM Time Out: 1:00PM Facility Name: Hi Tech Cleaners & Laundry, Inc. Facility Location: 5523 Roosevelt Blvd. Clearwater, FL, 33760 Responsible Official: Eun Hi Ma Phone No: 727-536-1288 Emis. Unit Description: New Large, Multi Matic L40, Serial No. 40SL-Ri-0807-7572 Dry-to-dry machine (2007). A TIF 5050A halogenated detector is used for leak checks. Permit Number: 1030459-003-AG Exp. Date: 5/17/2014 Facility Contact: Eun Hi Ma Phone: 727-536-1288 Compliance Status: IN MNC SNC PART I: NOTIFICATION (Check appropriate box) 1. Existing facility notified DARM by 9/1/96 2. New facility notified DARM 30 days prior to startup 3. Facility failed to notify DARM to use general permit PART II: CLASSIFICATION Facility indicated on notification form that it is: No Notification Form Drop-Off Store Out of business Petroleum Solvent Only A. 1. Existing small area source Dry-to-dry only, x <140 gal/yr Transfer only, x <200 gal/yr Both types, x <140 gal/yr (Constructed before 12/9/91) 3. Existing large area source Dry-to-dry only, 140> x <2,100 gal/yr Transfer only, 200> x <1,800 gal/yr Both types, 140> x <1,800 gal/yr (Constructed before 12/9/91) 2. New small area source Dry-to-dry only, x <140 gal/yr Transfer only, x <200 gal/yr Both types, x <140 gal/yr (Constructed on or after 12/9/91) 4. New large area source Dry-to-dry only, 140> x <2,100 gal/yr Transfer only, 200> x <1,800 gal/yr Both types, 140> x <1,800 gal/yr (Constructed on or after 12/9/91) This is a correct facility classification Y N Can not determine If no, please check the appropriate classification: Facility qualified for a general permit as number 4 above. Facility exceeds above limits and is not eligible for a general permit B. Highest 12-month consecutive total of perchloroethylene purchased in the preceding 12-month period: 56 Gallons. Month with highest use was May 2011. Did facility exceed limits Y C:\GPCI\Application\files_to_convert\6653\311472\1030459 75790.doc Page 1

PART III: GENERAL CONTROL REQUIREMENTS Is the responsible official of the dry cleaning facility: (Check appropriate boxes) 1. Storing perchloroethylene in tightly sealed and impervious containers? 2. Examining the containers for leakage? 3. Closing and securing machine doors except during loading/unloading? Y N 4. Draining cartridge filters in their housing or in sealed containers for at least 24 hours prior to disposal? 5. Maintaining solvent-to-carbon ratios and steam pressure for carbon adsorber beds according to the manufacturer s specifications? PART IV: PROCESS VENT CONTROLS In Part II-A: If classification (1) has been checked, no controls are required. Proceed to Part V. If classification (2) has been checked, the machine should be equipped with a refrigerated condenser (complete A below) If classification (3) has been checked, the machine should be equipped with either a refrigerated condenser or a carbon adsorber (complete A and B below). A Carbon adsorber must have been installed prior to September 22, 1993. If classification (4) has been checked, machine should be equipped with a refrigerated condenser (complete A and B below.) A. Has the responsible official of all new sources and existing large area sources: (check appropriate boxes) 1. Equipped all machines with the appropriate vent controls? 2. Equipped dry-to-dry machines with a closed-loop vapor venting system? 3. Equipped the condenser with a diverter valve so airflow will be directed away from the condenser upon opening the door? 4. Measured and recorded the temperature of the outlet exhaust stream of a refrigerated condenser on a weekly basis? 5. Repaired or adjusted the equipment within 24 hours if the exhaust temperature of the condenser exceeded 45 0 F? 6. Conducted all temperature monitoring after an appropriate cool down period and after verifying the coolant had been completely charged? B. Has the responsible official of an existing large or new large area source also: 1. Measured and recorded the exhaust temperature on the outlet side of the condenser located on dry-to-dry, reclaimer, and dryer machines on a weekly basis? Y N 2. Measured and recorded the washer exhaust temperature at the condenser inlet and outlet weekly? Is the temperature differential equal to or greater than 20 o F? 3. Measured and recorded the perc concentration in the exhaust stream weekly at the end of the final drying cycle while the machine is venting to the adsorber, if machines are equipped with a carbon adsorber? Is the perc concentration equal to or less than 100 ppm? Page 2

4. Assured that the sampling port on the carbon adsorber exhaust for measuring perc. concentrations is at least 8 duct diameters downstream of any bend, contraction, or expansion; is at least 2 dust diameters upstream from any bend contraction, or expansion; and downstream from no other inlet? 5. Equipped transfer machines (dryers, reclaimers, and washers) with individual condenser coils? 6. Routed airflow to the carbon adsorber (if used) at all times? PART V: RECORDKEEPING REQUIREMENTS Has the responsible official: (Check appropriate boxes) 1. Maintained receipts for perc purchased? 2. Maintained rolling monthly averages of perc consumption? Y Y N N 3. Maintained leak detection inspection and repair reports for the following: a. Documentation of leaks repaired w/in 24 hrs? or; b. Documentation of parts ordered to repair leak and leak repaired w/in 2 days and parts installed w/in 5 days of receipt? 4. Maintained calibration data? (direct reading instruments only) 5. Maintained exhaust duct monitoring data on perc concentrations? 6. Maintained startup/shutdown/malfunction plan? Y N 7. Maintained deviation reports? Problem corrected? 8. Maintained compliance plan, if applicable? Page 2

PART VI: LEAK DETECTION AND REPAIRS 1. Does the responsible official conduct weekly leak detection and repair inspection? Y N 2. Which method of detection does the responsible official use? Y N Visual examination (condensed solvent of exterior surfaces) Y N Physical detection (airflow felt through gaskets) Y N Odor (noticeable perc odor) Y N Use of direct-reading instrumentation (FID/PID/calorimetric tubes) Y N If using direct-reading instrumentation, is the equipment: Y N a. Capable of detecting perc vapor concentrations in a range of 0-500 ppm Y N b. Calibrated against a standard gas prior to and after each use (PID/FID only). Y N c. Inspected for leaks and obvious signs of wear on a weekly basis? Y N d. Kept in a clean and secure area when not in use. Y N e. Verified for accuracy by use of duplicate samples (calorimetric only)? Y N 3. Has the facility maintained a leak log? Y N 4. The following area should be checked for leaks by the operator: Y N Hose connections, fitting couplings, and valves Y N Muck cookers Y N Door gaskets and seating Y N Stills Y N Filter gaskets and seating Y N Exhaust dampers Y N Pumps Y N Diverter valves Y N Solvent tanks and containers Y N Cartridge Filter housing Y N Water separators Y N Shea Jackson Inspector s Name (Please Print) Inspector s Signature Date of Inspection Within one year of this inspection Date of Next Inspection Page 3

System Inspection and Leak Detection Are the following dry cleaning system components inspected weekly for perceptible leaks (sight, smell or touch) while the system is in operation ( 63.322(k))? (Inspection with a halogenated hydrocarbon detector or PCE gas analyzer also fulfills the requirement for inspection of perceptible leaks.) Are the following dry cleaning system components inspected monthly for vapor leaks using a halogenated hydrocarbon detector or PCE gas analyzer while the system is in operation? (Any inspection conducted according to this paragraph shall satisfy the requirements to conduct an inspection for perceptible leaks under 63.322(k) or (l). (1) Hose and pipe connections, fittings, couplings, and valves; (2) Door gaskets and seatings; (3) Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings Is the halogenated hydrocarbon detector or PCE gas analyzer operated according to the manufacturer's instructions? Is the vapor leak inspection conducted by placing the probe inlet at the surface of each component interface where leakage could occur and moving it slowly along the interface periphery? Is the PCE gas analyzer a flame ionization detector, photo ionization detector, or infrared analyzer capable of detecting vapor concentrations of PCE of 25 parts per million by volume Is the halogenated hydrocarbon detector capable of detecting vapor concentrations of PCE of 25 parts per million by volume and indicating a concentration of 25 parts per million by volume or greater by emitting an audible or visual signal that varies as the concentration changes? Page 4

ADDITIONAL SITE INFORMATION Facility Name: Hi Tech Cleaners & Laundry, Inc. ARMS #: 103 0459 Inspection Comments: During the inspection I met with the authorized representative Eunji Ma. I reviewed the 2010 and 2011 record calendars for the Dry Cleaning Machine. The records were up to date. The last check was performed 6/7/2010. (See photos) The temperature averages around 23-25 F weekly. This is acceptable temperature for the cool down cycle. The purchase invoices were dated 3/4/11 15 gals. The most recent hazardous was disposal was 6/29/2010 with 70 gallons perc and filters. Ms. Ma stated they only run equipment 2 3 cycles a week I inspected the machine. There were no leaks or spills observed on the machine or on floor. The covers were on all containers. The evaporator top had a new lid. I asked to check her Halogen Detector. She still has the TIF 5050A. I asked her to demonstrate how she used it for checking the equipment. The machine was not in operation at this time. Ms. Ma turned on detector and demonstrated its use. (See photos) There were no alarms; it did not detect any Perc leaks during the use around the equipment. There were no perchloroethylenes odors present during the observation of the equipment. I gave the copy of the inspection summary and the P2 dry cleaning pamphlet. Ms. Ma signed the annual certification. The facility was in compliance at this time. Page 5

Facility Name: Hi Tech Cleaners & Laundry, Inc. ARMS #: 103 0459 ADDITIONAL SITE INFORMATION Machine #1: Manufacturer Multi Matic Capacity lbs Model# L 40 Serial# 40SL-R1-0807- Mfg yr 2007 7572 Machine #2: Manufacturer Capacity lbs Model# Serial# Mfg yr Notification (unpermitted sources only): 1. Was the facility assisted in filling out the notification by the inspector? Y N 2. Did the facility insist on filling out its own notification, and will send it to FDEP? Y N Record keeping : 1. Does facility have statement/specs as to the design accuracy of the temperature sensor? Y N (Temperature of 45 F w/accuracy 2 F, or 7.2 C w/accuracy of 1.1 C) Hazardous Waste: 1. Is all perc. contaminated wastewater either treated or disposed of properly? Y N 2. If wastewater is evaporated, is it an approved system, and using carbon filtration? Y N 3. Does the facility have secondary containment for the dry-dry machine? Y N 4. Does the facility have secondary containment for any perc. waste containers? Y N Boiler: Manufacturer Fulton Hp 15 Model # FB025A Serial # RM7895A Mfg yr 2005 Fuel Type: Natural gas? Propane? Fuel oil? Comments: Exempt from permitting Page 6

Hi Tech Cleaners & Laundry, Inc. 5523 Roosevelt Blvd., Clearwater Project Id: 75790 Permit No: 1030459-003-AG Arms Number: 0459 Inspector: Shea Jackson Inspection Date / Time: 6/14/2011 / Source (EU): New Large, Multi Matic L40, Serial No. 40SL-Ri-0807-7572 Dry-to-dry machine (2007). A TIF 5050A halogenated detector is used for leak checks. Description: [Purchase order for perc ] Page 7

Hi Tech Cleaners & Laundry, Inc. 5523 Roosevelt Blvd., Clearwater Project Id: 75790 Permit No: 1030459-003-AG Arms Number: 0459 Inspector: Shea Jackson Inspection Date / Time: 6/14/2011 / Source (EU): New Large, Multi Matic L40, Serial No. 40SL-Ri-0807-7572 Dry-to-dry machine (2007). A TIF 5050A halogenated detector is used for leak checks. Description: [The facility 12 month Perc usage for May 2011 was 56 gallons] Page 8

Hi Tech Cleaners & Laundry, Inc. 5523 Roosevelt Blvd., Clearwater Project Id: 75790 Permit No: 1030459-003-AG Arms Number: 0459 Inspector: Shea Jackson Inspection Date / Time: 6/14/2011 / Source (EU): New Large, Multi Matic L40, Serial No. 40SL-Ri-0807-7572 Dry-to-dry machine (2007). A TIF 5050A halogenated detector is used for leak checks. Description: [The facility contact using halogen detector to check for Perc leaks] Page 1

C:\GPCI\Application\files_to_convert\6653\311472\1030459 75790.docPage 1 of 1