Character of Vortex Induced Vibration in Suspension Footbridge

Similar documents
The Effect of Pedestrian Traffic on the Dynamic Behavior of Footbridges M. Studničková

Dynamic behaviour of the steel footbridges with spatial pipe truss girders

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

CFD Analysis of Fire Characteristics on Subway Junction Station

Experimental Dynamic Behaviour and Pedestrian Excited Vibrations Mitigation at Ceramique Footbridge (Maastricht, NL)

DYNAMIC NUMERICAL ANALYSIS OF STEEL FOOTBRIDGE

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Simulation of Evacuation Process in a Supermarket with Cellular Automata

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Dynamic Performance of the Guarda Footbridge

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

DYNAMIC ANALYSIS OF FOOTBRIDGES A CASE STUDY CALATRAVA: PASSAGE CONNECTING THE ORIENT STATION AND THE

Analysis of Eccentric Wear of Sucker Rod and Design of Multi-Stage Flexibility Stabilizer

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Fuel Cell Stack CVM Chip Solder Joint Structural Analysis with ANSYS Sub-Modeling Technique

VALIDATION OF FINITE ELEMENT MODELS OF INJURY RISK IN VEHICLE-ROADSIDE BARRIER CRASHES

Analysis of the Design of an HVAC System in a Public Building

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Development of Large Size Hybrid Fan

THE CONTROL METHOD OF THE INFLOW TURBU- LENCE INTERACTION NOISE FOR ROUTER COOLING FAN

Performance Analysis of Centrifugal Fan by CFD

Simulation of Full-scale Smoke Control in Atrium

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

Numerical Analysis of Water Temperature Distribution in the Tank of. ASHPWH with a Cylindrical Condenser

Compression of Fins pipe and simple Heat pipe Using CFD

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

Induction heating with the ring effect for injection molding plates

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Design And Analysis Of Centrifugal Pump

Effect of Placement of Footing on Stability of Slope

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Research Article. ISSN (Print) , China. *Corresponding author Chen Hao

Performance-based Fire Design of Air-supported Membrane Coal Storage Shed

Effect of Foundation Embedment of PWR Structures in SSI Analysis considering Spatial Incoherence of Ground Motions

Full-Scale Measurement and Numerical Analysis of Liquefied Petroleum Gas Water Heaters with Ventilation Factors in Balcony

EVALUATING VIBRATIONS ON A SMALL-SCALE MODEL OF A TIMBER FOOTBRIDGE ABSTRACT

Related Problems in Ultrasonic Detection of Porcelain Insulator

The Low-Temperature Radiant Floor Heating System Design and Experimental Study on its Thermal Comfort

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Sprinklers Modeling for Tunnel Road Fire Fighting

1st City Issues Tongji International Symposium City & Real Estate Risk Management 2010

Construction Research Centre, Universiti Teknologi Malaysia (UTM-CRC), UTM Johor Bahru, Johor, Malaysia

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of Co-current Spray Dryer with Swirler at Air Inlet

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Study on an environmental simulation system of low/high temperature. for great space

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

ANALYSIS OF THE DYNAMIC CHARACTERISTICS AND VIBRATIONAL COMFORT OF SELECTED FOOTBRIDGES OVER THE S7 NATIONAL ROAD

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

Development of Bionic Air Cooler Used in High Temperature Coal Mine

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Design of Humidity Monitoring System Based on Virtual Instrument

Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia Pt. Raja, Batu Pahat, Johor, MALAYSIA

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Research Article Vibration Characteristics of Composite Footbridges under Various Human Running Loads

[Gupta* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

ISO/TS TECHNICAL SPECIFICATION

A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM)

Modification of Passivation Unit in Galvanizing Line

Heat Transfer in Evacuated Tubular Solar Collectors

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

DESIGN OF THE BODY FRAME OF A RAIL DETECTOR

Numerical simulation of single- and doublefaced W-beam guardrails under vehicular impacts on six-lane divided freeways

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-2, Issue-11, November- 2016]

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Hong Kong New Town Sustainability Analysis from the Perspective of Low-Carbon Eco-City Taking Tseung Kwan O New Town as an Example

NUMERICAL STUDIES ON SMOKE SPREAD IN THE CAVITY OF A DOUBLE-SKIN FAÇADE

RESPONSE OF ANCHOR IN TWO-PHASE MATERIAL UNDER UPLIFT

LONGITUDINAL VENTILATION FOR SMOKE CONTROL IN A TILTED TUNNEL BY SCALE MODELING

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

EFFECT OF RELICT JOINTS IN RAIN INDUCED SLOPE FAILURES IN RESIDUAL SOIL

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Slope stability assessment

Design & Analysis of Multi-part Fixture for Pin Quadrant of Quadrant sub-assembly of Cultivator

Effects of Splitter Blades on Centrifugal Pump Performance - A Review

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Available online at ScienceDirect. Procedia Engineering 102 (2015 )

Analysis of Embankments with Different Fill Materials using Plaxis-2D

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

Transcription:

Character of Vortex Induced Vibration in Suspension Footbridge *Jiawu Li 1), Yinzhi Wang 2) and Shuaiyu Chen 3) 1), 2), 3) Highway school of Chang an University, Xi an 710064, China 1) ljw@gl.chd.edu.cn ABSTRACT In this paper, the characteristics of vortex induced vibration by use of six types of sectional model in suspension footbridges are investigated. Combined with wind tunnel test results based on dynamic characteristic analysis and CFD-Fluent numerical simulation results, the influence of parameters, such as the porous ratio of handrail fence and pedestrian, on the character of vortex-induced deck vibration was probed. According to the test results, the mitigating measures were checked to improve the performance of suspension footbridge in service. 1. INTRODUCTION Suspension footbridges are very often characterized by low stiffness, narrow deck, low mass and small damping. So it is susceptible to vibrations when subjected to dynamic loads. Especially in recent decades, materials with improved mechanical characteristics are widely used in construction of footbridges so that the fundamental frequency of these structures is often close to the dynamic excitation of pedestrian and wind. As a result, vibrations are often commonly occurred in such structures. As is known, excessive vibrations have severe effects not only on comfort of pedestrians but also on duration of structures so many specifications develop provisions of vibrations to guide design of footbridges. For instance, EN 1990/A1 [1] mandates that verification of the vibration comfort criteria should be performed when the fundamental frequency of the footbridge is less than 5.0 Hz for vertical vibrations and 2.5 Hz for horizontal and torsional vibrations. Similarly, ISO 10137 [2] provided limit values of footbridge vibrations. The dynamic excitations of long-span suspension footbridges are primarily induced by 1) Professor 2), 3) Graduate Student

wind and pedestrians. Responses excited by walkers on footbridges are often lateral vibrations [5]. There are many examples of footbridges which have been temporarily closed for excessive human-induced lateral vibration. The first bridge to be closed after opening is Kiev Suspension Bridge [6] and the latest example is the Millennium Bridge [4]. With regard to human-induced vibrations, many papers have been published to analyze the mechanism or provide control measures [3-10]. Many papers have studied wind induced vibrations in recent decades but most of them are focused on the responses of footbridges without walking pedestrians [12-21]. It is impractical since congested pedestrians have a great influence on the aerodynamic configuration of the thin footbridge deck. In addition, dynamic characteristics of long-span suspension footbridge are sensitive to pedestrian properties due to the low stiffness and mass of bridge itself. Considering the factors mentioned above, influence of pedestrians should better be taken into account when wind-induced vibrations of footbridge are studied. Wind-induced vibrations of long-span suspension footbridge mainly include flutter and vortex-excited vibration. Flutter usually takes place with wind of high speed while vortex-excited vibration always imposed by wind of low speed [11]. In the cases of high wind speed, pedestrians will evacuate from bridge deck and long-span suspension footbridges are often closed. So the studies of flutter do not need to consider the influence of pedestrians on aerodynamic configuration and dynamic characteristics of footbridges. However, the studies of vortex-excited vibrations imposed by wind of low speed cannot ignore the influence of pedestrians, especially of congested pedestrians. This paper is focused on the studies of influence of pedestrians on dynamic characteristics of long-span suspension footbridges and vortex-excited vibration of long-span suspension footbridge with different distribution of pedestrians on deck. The relation of natural frequencies and pedestrian density will be found in the first part and the critical pedestrian density, used to determine whether the natural frequencies of long-span suspension footbridge are seriously affected, of pedestrians will be provided. The second part will analyze the vortex-excited vibration of long-span suspension footbridge in the case of different distributions of fixed pedestrians on bridge deck by wind tunnel test and CFD. The result of wind tunnel test will be compared with the result of CFD. 2.Dynamic characteristics footbridge suspension 2.1 General of footbridge suspension This long-span footbridge suspension span is 369 m and double 16.65 m height towers(fig.1),has rise-span ratio of 1/12, and the width of the composite girder is 3.6 meters, so the width-span ratio is up to 1:102. as Figure 2.

Fig. 1 elevation Fig 2. cross-section 2.2 Dynamic properties (1) Critical pedestrian load According to the characteristics of pedestrian flow especially the crowd flow characteristics in the tourist season and emergency situations, put forward extreme pedestrian load conditions. The research does not consider the effect of dynamic properties of pedestrians moving on the bridge. Referring to "Suspension Bridge Design Specifications" and "German Pedestrian Bridge Design Standard EN03 (2007) " for the definition of the level of pedestrian traffic, take a high-density pedestrian flow, defined a maximum load of 2.5 kn/m 2 as the pedestrian load. To further research the effects of the value of the pedestrian load on the the dynamic characteristics of long-span footbridge suspension, make corresponding reduce to the maximum pedestrian load reduction crowd, and defined scale factor between pedestrian load and dead load of real bridge. = GP GB G P represents Pedestrian load, in which the maximum value is 2.5kN/m 2. GB represents the mass of real bridge is 300 Kg/m. The scale factor is shown in the tab.1.

Tab. 1scale factor Pedestrian load (kn/m 2 ) 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.5 Scale factor 0.25 0.5 0.75 1.00 1.25 1.5 2.00 2.08 The pedestrian load impacts the bridge natural frequency. Figure 3 and figure 4 show the influence of pedestrian on the first two frequencies. When the scale factor is around 0.75, the first order anti-symmetric vertical bending and torsional frequencies both have significant changes. And at this time pedestrian load is 0.9 kn/m 2, which can be defined as critical pedestrian load for the following analysis. Fig 3 bending

Fig 4 torsion (3) load conditions for extreme population The following four groups of extreme pedestrian load cases are proposed. Take the critical pedestrian load of above analysis as a reference value. We carried on the contrast analysis to the different extreme crowd load conditions. Four types of load conditions for extreme populations are classified as shown in table 2. Name Case 1 Case 2 Case 3 Case 4 Tab 2 load conditions for extreme population Description No pedestrian load. Encountered strong winds or a temporary situation, the bridge is closed and the pedestrian load is zero. Full pedestrian load. In the tourist season the bridge has high density of people and full pedestrian load. Longitudinal semi-cross pedestrian load. Such as an emergency evacuation, pedestrian are concentrated in half of bridge. Lateral semi-cross pedestrian load. For example, visitors enjoy the scenery on one side of the bridge. For first anti-symmetric vertical bending and torsional frequency, conduct comparative analysis between case 2, 3, 4 and case 1. The results are shown in figure 5 and figure 6.

Fig 5 bending frequency Fig 6 torsional frequency The above results show that after imposed on the critical pedestrian load, the first vertical bending frequency and torsional frequency of case 2, 3, 4 has significant changes compared with that of case 1. The results also show that the critical pedestrian load does have a great impact on dynamic characteristics of long-span footbridge suspension. Further analysis shows that after imposed on the critical pedestrian load, the first order anti-symmetric vertical bending frequencies of case 2, 3, 4 all have dramatically drops compared with case 1. For the first torsion frequency, after imposed on the critical pedestrian load, that of case 2, 3 have sharply drops. But that of case 4 is increased. This phenomenon indicates that lateral semi-cross pedestrian load has significant

effects on first order anti-symmetric torsion frequency of long-span footbridge suspension. 3.Sectional model test To check the section with and without pedestrian whether occurs vortex-induced vibration in these conditions, the sectional model tests were conducted. 3.1 Wind tunnel tests The sectional model test is shown in figure7. The bending frequency and the torsional frequency are 1.204Hz and 2.345Hz respectively, system damping ratio is 1% Based on the average body index of Chinese adults whose age is within 30 to 34 in 2010 National Physique Monitoring Bulletin (height 169.8cm, weight 69.8kg, bust 91.1cm, waist 84.0cm, hip 93.9cm), the pedestrian geometry outer contour was approximately simulated by three rectangular,which is shown in Figure 8. It is based on a scale of 1:14 and model of human body is 121.4 millimeters high, 30.35 millimeters wide in total and 14.0 millimeters thick. Fig 7 sectional model test system

Fig 8 Pedestrian model(unit:mm) The test is carried out in the uniform wind field, the wind speed is selected by 2m/s~15m/s, and the wind attack angle is -5, -3, 0, +3 and +5. Figure 9 shows the photo of the vortex vibration test under two case. (a)case 2 (b)case 3 Fig. 9 Vortex vibration test 3.2 Test result For the case of fully closed handrail (simulation of fully frozen handrail), responses of vortex-induced vibrations at wind attack angle of ±5 ±3 and 0 were shown as Fig 10. The results indicate that the vertical vortex-induced vibrations of relatively large amplitude take place at wind attack angle of -5-3 and 0 and the locked wind speed is 5.0~10.1m/s. In addition, the vertical vortex-induced vibrations of maximum amplitude occur at the wind attack angle of -3 and the value of vertical displacement RMS is 24.2cm, from which the value of vertical displacement of practical bridge is converted to 34.2cm. It follows that the vertical vortex-induced vibrations of relatively large amplitude usually take place at low wind speed when handrails on both sides of stiff girder are fully

closed. Fig 10 VIV fully closed handrails 4. CFD simulation To analyze the vibration, the character flow around deck are investigated by use of CFD technique. Case I, case 2 and case 4, assuming the crowd load along the whole length of the bridge is a continuous distribution so that to establish a planar model in CFD to get the streamline. It is found that the vortex shedding in the above mentioned conditions is very obvious. Usually, it is generally believed that where regular vortex shedding appears, the vortex will induce vibration in a certain wind speed. For further investigation, a 3D CFD model considering the dispersion and randomness of the actual distribution of the crowd load on the deck was established. 4.1 CFD analysis Different from the wind tunnel test, CFD model uses a full-scale model, which is shown in Fig 11. The model of human body is 169.8 centimeters high, 42.5 centimeters wide in total and 19.6 centimeters thick.

Fig 11 Pedestrian model(unit:mm) Numerical modeling is based on the calculation platform Fluent in commercial software CFD, adopting the k-ω turbulence model which has better simulation result of external streaming for bluff body, calculating as steady flow. Resolution of equation adopts SIMPILEC arithmetic. The scale adopts the real one of bridge. The scale of calculation flow field is: length 120m, height 90m. Mesh division in 3D calculation zone adopts prism mesh (shown as figure 12). a) CFD model b) mesh Fig 12 CFD model and mesh The wind speed is set to 15m/s. The wind angle of attack is 0, ±3 and ±6. extreme crowd load conditions are classified as shown in tab3, and the basic section form shown as figure 13.

Name Case 1 Case 2 Case 3 Case 4 Case 5 Case 6 Tab 3 Classification of load conditions (Continued) Description No pedestrian load. Encountered strong winds or a temporary situation, the bridge is closed and the pedestrian load is zero. Full pedestrian load. In the tourist season the bridge has high density of people and full pedestrian load. Longitudinal semi-cross pedestrian load. Such as an emergency evacuation, pedestrian are concentrated in half of bridge. Lateral semi-cross pedestrian load. For example, visitors enjoy the scenery on one side of the bridge. Interval closed railing with no pedestrian load. Interval closed railing with random population distribution. (a) Case 1 (b) Case 2 (c) Case 4 Fig 13 Basic calculation section form For case I, II, IV, V, VI was carried out, without considering Case III. The length of the bridge is 360 meters, 18-meter-interception of which was established into a 3D model, as was shown in fig 14. (a)case 1 (b)case 2

(c)case 4 (d)case 5 (e)case 6 Fig 14 3D models 4.2 CFD results Figure 15 presents streamlines from three views under the five different cases. (a) Case 1 (b) Case 2 (c) Case 4 (d) Case 5

(e) Case 6 Fig 15 streamlines Figure 16 lists the streamlines and pressure contours of Case 1 under different wind attack angles. It is not difficult to find that vortex appears at the end of the section of the bluff body flow zone of negative pressure and negative pressure area is bigger while the negative pressure value is larger, so is the size of the vortex. The bridge deck structure turns into Leeward with positive attack angles, which are in the negative pressure zone and the formation of vortex size on which is large. The bottom of bridge deck structure turns into Leeward with negative attack angles. However, the vortex is dispersed into a lot of small eddies, but due to influence of the deck rails, beams and oblique bracing structures. In fact, vortex vibration generally does not occur in the truss structure. (a) 0

(b) 3 (c) -6 Fig 16 streamlines and pressure of Case 1 Figure 17 shows the streamlines of Case 2 and Case 4 in the zero angle of attack. Compared with Case 1 in Fig 16 (a), size of pedestrian cannot be neglected. Karman vortex street with alternating vortex shedding appears on the Leeward of pedestrian in Case 2, which can cause the torsional vibration of the bridge the vortex frequency of the vortex shedding and the natural frequency of the bridge are close at a certain speed of wind. The cross section of Case 4 is near to the square and the size of the lower deck rails, beams and oblique bracing structures is much smaller with respect to the section with large population so that it can be neglected. Such cross section is easy to form vortex shedding at the bottom of the deck or at the top of the crowd at different wind angles of attack with the same size of the bridge width, which causes the vertical bending vibration of the bridge. At the same time, two vortexes with the same size appear up and down beside the leeward side of the pedestrian which is not easy to cause the vortex induced vibration at zero angle of attack but may cause torsional vortex induced vibration on the bridge under certain wind attack angle.

Fig 17 flow trace of case II and case IV at wind attack angle of 0 Although regular vortex shedding apparently occurs in flow trace figures of case II and case IV, vortex induced vibrations did not be observed in wind tunnel tests of corresponding cases. Thus it can be seen, the bridge structure of such aerodynamic configurations cannot be analyzed with planar CFD models. Next, streamline of planar and 3D CFD models are compared as is shown in Fig 18. flow passes around pedestrians because of the longitudinal and lateral gap between pedestrians, which indicates the reason for which the vortexes of wake zone are broken up. (a) case 1 (b) case 2 (c) Case 4

d) case 1 e) case 4 Fig 18 streamline For the case 5, CFD results shown in Fig 19, streamlines discharged for handrail converge at the leeside of handrail and form vortex. It is concluded that vortex will occur at the leeside of girder when the upper or lower side of handrail are fully closed. However, when the handrail is alternately closed along longitudinal direction, streamlines around handrail plate laterally and break up vortexes formed in wake zone of girder. Thus similar to pedestrians, alternately closed handrail along longitudinal direction can mitigate response of vortex-induced vibration. Therefore, upper closure or lower closure of handrail forms should be avoided. Compared with the wind tunnel tests of all closure of handrail, vortex-induced vibration is find very sensitive to the forms of handrail closure. Long-span suspension footbridge should better adopt handrail with higher porous rate. (a) (b)

(c) Fig 19 streamlines of case V (d) When pedestrians are randomly distributed as is shown in Fig 14(e), the space of pedestrians and handrail are not uniformed on different sections. The wind flowing through the gaps can break up the vortex formed in the wake zone. Vortex-induced vibration is caused by alternately shedding vortexes. If there aren t regular vortexes, vortex-induced vibration cannot take place. The streamlines are shown in Figure 20. (a) (b) (c) Fig 20 Streamlines of case VI (d)

This illustrates that scattered action on vortex of passing flow around the body in longitudinal section. So the pedestrian distribution can mitigate the vibration of deck. However, when high density pedestrian is distributed on the deck and it has little spacing among people, the pedestrian would completely block the wind flow around the plane. In this case, the vortex shedding will not be broken and when the shedding frequency is close to the base frequency structure, the vortex-induced vibration appears. 4. Conclusion (1) Pedestrian load and its distribution have enormous influence on the dynamic characteristic of long-span suspension footbridge. The critical pedestrian density, which influences the dynamic property that long-span suspension footbridge. (2) The longitudinal correlation for long-span suspension foot bridge, not meet the strip assumption, that is, the vortexes get balanced one another in the longitudinal direction, and then vortex-induced vibration never occurs. (3) For long-span suspension footbridge, pedestrian changes the shape of cross-section a lot, and forms the main part of bridge cross-section. (4) Handrail with high porous ratio makes the thin structure with high ventilation ratio (such as long-span suspension footbridge) avoid the occurrence of vortex-induced vibration. (5) Vortex-induced vibration is sensitive to the type of handrail. For the truss beam of long-span suspension footbridge, handrail of grid type is preferred, but fully-closed handrail is proscribed.

REFERENCES [1] EN 1990:2002/A1:2005: Eurocode Basis of structural design. Application for bridges. [2] ISO 10137: Bases for Design of Structures. Serviceability of buildings and walkways against vibrations. Geneva: International Organization for Standarization, 2007. [3] Nakamura SI. Model for Lateral Excitation of Footbridges by Synchronous Walking. J Struct Eng 2004;130(1):32-37. [4] Dallard P, Fitzpatrick AJ, Flint A, Le Bourva S, Low A, Ridsdill RM, Willford M. The London Millennium Footbridge. Struct Eng 2001;79(22):17 33. [5] S.S. Law, Z.M. Wu, S.L. Chan a. Vibration control study of a suspension footbridge using hybrid slotted bolted connection elements. Engineering Structures 2003;26 (2004):107 116. [6] Blekherman AN. Swaying of Pedestrian Bridges. J Bridge Eng 2005;10(2):142-150. [7] Fujino Y, Pacheco BM, Nakamura S. Synchronization of human walking observed during lateral vibration of a congested pedestrian bridge. Earthquake Engng Struct 1993;22(9):741 58. [8] Zivanovic S, Pavic A, Reynolds P. Vibration serviceability of footbridges under human-induced excitation: a literature review. J Sound Vib 2005; 279(1-2): 1-74. [9] Ebrahimpour A, Hamam A, Sack RL, Patten WN. Measuring and modeling dynamic loads imposed by moving crowds. J Struct Engng ASCE 1996;122(12):1468 74. [10] Fitzpatrick T. Fitzpatrick: the Millennium Bridge. London: Royal Academy of Engineering, 2001. [11] CHEN Zheng-qing. Bridge Wind Engineering[M]. Beijing: China Communications Press, 2005. [12] Li Jia-Wu, Che Xin, Gao Fei. Effects of wind-resistant control measures against flutter instability of a narrow suspension bridge[j]. Journal of vibration and shock,2012,31(23):77-86 [13] Ma Lin-lin. Study of narrow truss suspension bridge flutter stability[d]. Chang an university,2011 [14] HE Han-xin, LIU Jian-xin. Study on Wind-resistant Measures and Their Optimization for Long-span and Slender Suspension Bridge[J]. Journal of Highway and Transportation Research and Development, 2010, 27(3), 93-97. [15] 白桦, 李德峰, 李宇等. 人行悬索桥抗风性能改善措施研究 [J]. 公路,2012:1-6 Bai Hua, Li De-feng, Li Yu. A study on Improving measures for Wind-Resistance Stability of Pedestrian Suspension Bridge[J]. Highway, 12:1-6 [16] CUI Xin, LI Jia-wu, LIU Jian-xin. Research on Aerodynamic Stability of Narrow Suspension Bridge Based on Wind Tuunel Test [J]. Journal of Highway and Transportation Research and Development, 2011, 28(1), 91-95.

[17] Xiong Yao-qing, He Yun-ming, Wu Xiao-bin. Research on dynamic characteristics and wind vibration response of a pedestrian large-span and slender suspension bridge[j]. Journal of building structures,9(40):148-153 [18] Miros P, Aerodynamic Characteristics of a Stressed Ribbon Pedestrian Bridge Span 252m Journal of Wind Engineering and industrial Aerodynamics, 1994, 53, 301-314. [19] Brown, Sean L. Montgomery, C. James and Rozendaal, Mike(2012), Fort Edmonton Footbridge - Erection engineering for a pedestrian suspension bridge, WN All fields, 1969-2014 [20] Nakamura, Shun-Ichi (), Field measurements of lateral vibration on a pedestrian suspension bridge, Institution of Structural Engineers, 2003, 81, 22-26 [21] Juozapaitis, A., Vainiunas, P. and Kaklauskas, G, A new steel structural system of a pedestrian suspension bridge, Elsevier Ltd, 2006, 12, 1257-1263