AQUASTYLUS Chilled Water Fan Coil Convertible Type CFEA Series 50/60 Hz

Similar documents
Split System, 18,000-48,000 Btu/h Underceiling Type MCC Series 50 Hz

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

Installation Operation Maintenance

Installation Operation Maintenance

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

Installation Instructions

Installation Operation Maintenance

Installation Operation Maintenance

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Air Conditioner. user installation & manual manual. imagine the possibilities

Installation Instructions

INSTALLATION & OPERATING MANUAL CWA2 Chilled Water Air Handler with Electric Heat 18,000 60,000 BTUH

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

SM Field Installed Electric Heat Kit

ABS HOPPER LID SWITCH KIT ASSEMBLY

INSTALLATION MANUAL LIST OF SECTIONS. 1 General 1 3 Louvered Door Frame Assembly Installation 3 2 Safety 2 4 Coil Cabinet Installation 5

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Installation Instructions

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CH250 AND CH251 CHILLERS

ED200/250 KSTYLE LID KITS

G-10f/GCG-10f UPRIGHT COOLER

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Installation Operation Maintenance

INSTALLATION INSTRUCTIONS

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

Installation Instructions

WALL-MOUNTED FAN COIL UNIT. MHQWW-xx-H-1-U 208V-230V-50/60Hz. Installation & Operation Instruction Manual

42PHW / 42PHQ 42PHQ...K

Installation Owner Diagnostics

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

50BY, BL. Ÿà Õ µ µ Èß ËÕߪ Õ» å Single-Package Cooling Units 50BY, BL 50BY, BL

INSTALLATION INSTRUCTION

Installation Instructions

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation Instructions

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

CH750, CH751 & CH951 CHILLERS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

GCG-26c. Instruction Manual. G-Series Cooler

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Installation Instructions

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

IMPORTANT SAFETY INFORMATION:

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

Installation Guide. Wind Baffle for Outdoor Units VRF-SVN079A-EN. VRF Single-Phase and C-Series Systems. October 2015 SAFETY WARNING

Installation Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Vertical Concealed Fan Coil. FCVC Series MANUAL INSTALLATION, OPERATION, & MAINTENANCE

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

Installation Instructions

Installation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4

Installation Instructions

INSTALLATION INSTRUCTIONS

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

MANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved.

Owner s Information Manual

Installation Instructions. Instructions de montage. Instrucciones de instalación HC

XT Series Thermostats

CWA4-HW (4-Pipe) Rev. 1.2

51AKS I S O OWNER S MANUAL

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

Installation Instructions

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

INSTALLATION INSTRUCTIONS

Owner's Manual TABLE OF CONTENTS

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

INSTRUCTIONS! DO NOT DISCARD!

INSTALLATION INSTRUCTIONS

Ceiling Concealed Fan-Coil Unit

Installation Instructions

COOPER POWER SERIES. QD3 Quik-Drive Tap-Changer Position Indicator Drive Gear Kit Number B11. Voltage Regulators MN225056EN

HEAT PUMP INSTALLATION MANUAL

Owner s Manual TABLE OF CONTENTS

Installation Instructions

Quest 105, Dry155, and 205 Dual

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

Installation Operation Maintenance

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

INSTALLATION INSTRUCTIONS

Transcription:

Installation Manual AQUASTYLUS Chilled Water Fan Coil Convertible Type CFEA Series 50/60 Hz 50 Hz Models Cooling Only CFEA 04 C0M1 CFEA 06 C0M1 CFEA 08 C0M1 CFEA 10 C0M1 CFEA 12 C0M1 CFEA 14 C0M1 CFEA 16 C0M1 CFEA 20 C0M1 60 Hz Models Cooling Only CFEA 04 C0M2 CFEA 06 C0M2 CFEA 08 C0M2 CFEA 10 C0M2 CFEA 12 C0M2 CFEA 14 C0M2 CFEA 16 C0M2 CFEA 20 C0M2 Cooling/Heating CFEA 04 CEM1 CFEA 06 CFM1 CFEA 08 CBM1 CFEA 10 CHM1 CFEA 12 CJM1 CFEA 14 CJM1 CFEA 16 CKM1 CFEA 20 CLM1 Cooling/Heating CFEA 04 CEM2 CFEA 06 CFM2 CFEA 08 CBM2 CFEA 10 CHM2 CFEA 12 CJM2 CFEA 14 CJM2 CFEA 16 CKM2 CFEA 20 CLM2 October 2002 1

General Information General Information This Installation Manual is given as a guide to good practice in the installation by the installer of CFEA chilled water fancoil system. Installation procedures should be performed in the sequence that they appear in this manual. For installing the unit to operate properly and reliably, it must be installed in accordance with these instructions. Also, the services of a qualified service technician should be employed, through the maintenance contract with a reputable service company. Read this Installation Manual completely before installing the air conditioning system. About this Manual Cautions appear at appropriate places in this Installation Manual. Your personal safety and the proper operation of this machine require that you follow them carefully. The Trane Company assumes no liability for installations or servicing performed by unqualified personnel. All phases of the installation of this air conditioning system must conform to all national, provincial, state and local codes. American Standard Inc.2001 About the Unit These CFEA units are assembled, pressure tested, dehydrated and run tested before shipment. The information contained in this manual applies to CFEA units are designed to operate in cooling mode only and in cooling or heating modes. Trane CFEA series of chilled water fancoil systems offer three styles of installation: floor, low wall and under ceiling with both LCD wireless remote control or wired control. Trane CFEA series provide flexibility and savings. Note: For model CFEA 14, CFEA 16 and CFEA 20, there are only two styles of installation: under ceiling and low wall. Reception On arrival, inspect the unit before signing the delivery note. Specify any damage of the unit on the delivery note, and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery. Notify the dealer at the same time. The unit should be totally inspected within 7 days of delivery. If any concealed damage is discovered, send a registered letter of protest to the carrier within 7 days of delivery and notify the dealer. Warning Warnings are provided at appropriate places in this manual to indicate to installers, operators and service personnel of potentially hazardous situations which, if not avoided, COULD result in death or serious injury. Caution Cautions are provided at appropriate places in this manual to indicate to installers, operators, and service personnel of potentially hazardous situations which, if not avoided, MAY result in minor or moderate injury or malfunction of the unit. Your personal safety and the proper operation of this unit require that you follow them carefully. The Trane Company assumes no liability for installations or servicing performed by unqualified personnel. Warranty Warranty is based on the general terms and conditions by country. The warranty is void if the equipment is modified or repaired without the written approval of The Trane Company, if the perating limits are exceeded or if the control system or the electrical wiring is modified. Damage due to inappropriate installation, lack of knowledge or failure to comply with the manufacturer s instructions, is not covered by the warranty obligation. If the installation does not conform to the rules described in Installation Manual, it may entail cancellation of warranty and liabilities by The Trane Company. Important This document is customer property and is to remain with unit. Please place in service information pack upon completion of work. These instructions do not cover all variations in systems, nor do they provide for every possible contingency to be met in connection with installation. Should further information be desired or should particular problems arise which are not covered sufficiently in this manual, the matter should be referred to your Trane Sales representative. 2

Contents General Information 2 Location and Preparation of Units 4 Unit Installation 5 Connection of Water Piping 6 Condensate Drain Piping 7 Electrical Installation 7 Remote Control Installation 8 Electronic Room Thermostat 9 Installation Typical Wiring Diagram 10 Dimensional Data 13 Notes 15 3 3

Location and Preparation of Units 1. Select an appropriate position that allows every corner of the room to be uniformly air conditioned and where it is easy to route the water piping. 2. Ensure that the floor or ceiling construction is sufficient to fully support the weight of the indoor unit. 3. Consideration must be given to ensure an unobstructed flow of supply and return air. 4. Length of the condensate drain hose should be kept as short as possible. (Figure 1) 5. Recommended service clearance as shown in figure 2, 3 and 4. 20 cm. 20 cm. Maintenance area (Ceiling mounted) 30 cm. Min. 120 cm. Min. 20 cm. Min. 30 cm. Maintenance area (Low wall mounted) Figture 2 20 cm. Figture 4 Indoor unit Figure 1 Drain hose 20 cm. 30 cm. Maintenance area (Floor mounted) 6. Do not install unit in direct sunlight or near other heat sources as this may affect performance. Do not allow outside air to directly enter unit or condensate may form at the unit s discharge. Note: For CFEA14 - CFEA 20 the unit should be installed over the floor at least 20 cm. Figure 3 4 4

Unit Installation Indoor Unit 1. Select a location to route piping, wiring and drain pipe. 2. Make a hole in the wall using a key hole saw or hole-cutting drill attachment. The hole should be made at a slight downward slant to the outdoor side (Figure 5). Indoor side Outdoor side 6. Remove the return grille, squeeze the center of plastic linkage, then unscrew the two end linkages to free them from the retainers (Figure 7). Push Push Figure 7 Push Push Note: = A 0.49" x 1.575" - 4 SLOT (Mounting hole) (12.5 mm 40.0 mm) Unit Size B CFEA 04-06 36.2" (920) CFEA 08 46.1" (1,170) CFEA 10-12 55.9" (1,420) CFEA 14 65.7" (1,670) CFEA 16-20 75.6" (1,920) 8. Place or hang the unit at the selected position. Figure 5 Before cutting, check that no pipes or studs are directly behind the place to be cut. Avoid areas where electrical wiring or conduits are located. 3. Place the unit on a solid and level foundation. 4. Piping, wiring through and drain pipe of low wall and floor mounted units can be routed, to rear or left and right side of unit when facing front. Ceiling mounted can be routed straight downward. 5. To gain access to the electrical terminals, the drain and the water piping, pull the return grille forward (Figure 6). 7. Unscrew at the grille bottom hinges, and pull out the screw. Then, push down on the panel and pull out (Figure 8). Figure 8 Pull out Pull out A 8.5"(215) 0.83"(21) Pull 0.83"(21) B Pull Figure 6 Figure 9 5 5

Connection of Water Piping The unit water piping connections are provided with a make straight fitting. The water piping connection is located on the right hand side of the unit (Figure 11). To complete piping connections, connect the female connections to the male adapter of the water piping connections at the inlet and outlet of the coil. Then, screw in and fasten the connections with an adjustable wrench or torque wrench. Unit Model CFEA 04-06 CFEA 08-20 Pipe Connection (in) Male 1/2 NPT Male 3/4 NPT Figure 11 Position of Piping Hole 63.0 FRONT VIEW 59.0 Ø3" KNOCK-OUT @ 2 PLACES 59.0 BOTTOM VIEW 43.0 6 6

Condensate Drain Piping - The drain hose should run straight down the wall to a level where the runoff will not stain the wall. - There should be no traps. - Avoid putting the end of the hose in water. - When the drain hose is placed in the room, insulate the hose with foam polyethylene to avoid damage to the ceiling or furniture. - To conveniently drain the system, the drain hose must slant downward, with a slope of at least 1 : 50 to prevent leakage. Figure 12 shows the unit in the floor mounted position. Indoor unit Slant Drain hose Figure 12 Electrical Installation All wiring and grounding must comply with local electrical codes. 1. Wiring Important Safeguards: - Check the unit nameplate for electrical rating. Be sure wiring is done according to local codes and wiring diagram. - Connect electrical ground to all units. - Wiring should not touch motors or moving parts. -The manufacturer will accept no responsibility for problems caused by unauthorized changes in the internal wiring. - Pass the system wiring through the PVC pipe conduit or metal conduit, referred to Unit Installation section. (both power and control lines). - Make sure all connections are tight. 2. Electrical Connections See Section: Wiring System Diagram. Note: - All wiring must comply with local codes. - After completing the connections, re-confirm them to be in accordance with the unit and system wiring diagrams. 7 7

ON OFF Remote Control Installtion Locate and attach the wireless remote control and wired control as follows: 1. Do not place the control and the remote control near heat sources or expose to the direct rays of the sun. 2. Do not expose the control to the indoor unit s supply air stream. 3. Do not place in a confined space. 4. Install the remote control holder as shown in Figure 13, 14. Dimension Screw tap pan 3.5 X 13 mm. Wireless Remote Control Figure 13 Wired Remote Control Figure 14 Mounting Bracket 8 8

22 POWER ON OFF 16 o C 27 COMP COOL 30 WARM FAN 22 POWER ON OFF 16 o C 27 COMP COOL 30 WARM FAN Electronic Room Thermostat Installation Precaution - This room thermostat is an electronic control device, which requires special precaution for installation. - Follow the wiring diagram attached on page 9 for reference. - Room thermostat should not be located at or near the water drop or water mist. - Be careful not to leave any copper wire or piece of metal inside the control set. For better temperature control, please see the attached picture for the suitable room thermostat s location. Floor Type Ciling Type X X X 150 cm. 150 cm. Location of room thermostat - Do not place the control set and room thermostat near heat sources or expose to the direct sunlight. - Do not expose the room thermostat to the indoor unit s supply air stream. - Do not place the room thermostat in a confined space. X X X X 9 9

Typical Wiring Diagram POWER SUPPLY 220-240VAC 1PH/50Hz WIRING DIAGRAM CAPACITOR WH BR N L HIGH MED LOW BLOWER MOTOR VALVE HIGH MED N LOW P2 P3 P4 P6 BLK BL RD WH VALVE C CHILLED WATER CONTROL VALVE NOT AVAILABLE FOR WITHOUT VALVE MODEL DESCRIPTION MS COLOR CODE BLK BLACK BL BLUE WH WHITE RD RED BR BROWN FIELD WIRING FACTORY WIRING COIL JUNCTION TERMINAL BOARD BY FACTORY COMPRESSOR MOTOR CONTACTOR GROUND TERMINITOR 10 10

Typical Wiring Diagram CFEA, CHILLED WATER FANCOIL UNIT WITH WIRED CONTROL COOLING ONLY AND COOLING/HEATING MODEL 11 11

CFEA, CHILLED WATER FANCOIL UNIT WITH WIRED CONTROL COOLING ONLY AND COOLING/HEATING MODEL 12 12

Dimensional Data CFEA04-12(50/60Hz) 151.5 215.0 161.5 13 13

CFEA14-20(50Hz) CFEA14-20(60Hz) 151.5 215.0 161.5 14 14

Notes 15 15

Trane Thailand 7th Floor, Ploenchit Center Building 2 Sukhumvit Road, Klongtoey Bangkok 10110 http://www.trane.com An American Standard Company Literature Order Number 0701 Supersedes 0999 Stocking Location Bangkok, Thailand Õ Õ å 35 À Ÿà 8.ªŸÉ â ßæ µ. ß µâ Õ.æ ª ß. ÿ ª 10130 Since The Trane Company has a policy of continuous product improvement, it reserves the right to change design and specifications without notice. 16 29/10/02, 2:48 PM