Study on Fire Detection at Cultural Assets Buildings with Botanical Roofs

Similar documents
InstrumentationTools.com

LEARNING SPECIAL HAZARD DETECTION TYPES

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

Filtrex A Smoke Detector for Difficult Environments

PRELIMINARY STUDIES ON MECHANICAL SMOKE EXHAUSTS IN LARGE SPACE BUILDING FIRES

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Experimental Study on Effect of Escape Guidance in Fire Smoke by Travelling Flashing of Light Sources

EXTINGUISHING SYSTEM DETECTION AND CONTROL

Optimization of Sensitivity Characteristics of Photoelectric Smoke Detector to Various Smokes

ASSESSMENT OF TIMBER PARTITION MATERIALS WITH FIRE RETARDANTS WITH A ROOM CALORIMETER

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

PASSIVE AND ACTIVE FIRE PROTECTION OF THE AIR HEATED SOLAR HOUSES

Large-scale fire test for interior materials of the Korean high speed train

Contact person Date Reference Page Alen Rakovic P (19) Fire Research

THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION

Development of Seismic-induced Fire Risk Assessment Method for a Building

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Max Fire Box Users Guide

A GEM-based detector for detection and imaging sparks and flames G. Volpe 1 and V. Peskov 2. Abstract

Safety Engineering. Fire Protection Systems and Life Safety Systems

Photoelectric Smoke Alarm

THE EFFECT OF HIGH TEMPERATURE AIR DRYING ON EVAPORATION, RUNNABILITY AND COATED PAPER PROPERTIES. Pertti Heikkilä and Pasi Rajala

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Specifications of V-Line burners

Experimental Room Fire Studies with Perforated Suspended Ceiling

Characterising the smoke produced from modern materials and evaluating smoke detectors

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

A Comparison of Carbon Monoxide Gas Sensing to Particle Smoke Detection in Residential Fire Scenarios

Abstract. Introduction

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

DETERMINATION OF SMOKE QUANTITIES TO BE USED FOR SMOKE DETECTION PERFORMANCE GROUND AND FLIGHT TESTS

SharpEye Flame Detector Selection Guide

FIRE PROTECTION & PREVENTION

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Meeting NFPA standards for

A Study on Safety by Risk Assessment of Clean Room

UL268 7 th challenge with single infrared smoke detector

UWB Stepped-FM Sensor for Home Security

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

THE VULNERABILITY OF ROTTING MARINE STRUCTURES TO IGNITION BY DISCARDED CIGARETTES (THE 2003 SATURNA ISLAND WHARF FIRE)

An experimental study of the impact of tunnel suppression on tunnel ventilation

Itaru TAKAHASHI Ph.D 1 Akihiko KUROIWA 2

Indicative hoarding fire experiment. Prepared for: London Fire Brigade. 21 May 2014 Client report number

Chapter 17, Initiating Devices

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

SIMPLE AND RELIABLE FIRE DETECTION IN ROAD TUNNELS

Final Report FIREMAN

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

FIREYE C9707A ALL FUEL SCANNER

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

Improvement of Temperatures Stratification caused by Air-conditioner. by means of Ceiling Fan in Classroom

Indicate whether the statement is true or false.

EVALUATION ON PERFORMANCE OF PHOTOELECTRIC SMOKE DETECTORS IN THE ZONE DETECTION SYSTEM

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

VICTORIA BC V8R 1C4. # of Occupants (At time of fire): 30 # of Injured: 0 # of Deaths: 0 Total Dollar Loss Estimate:

Seed Drying. 1. Surface moisture of the seed that initially removed by the drying air.

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Leakage of Mildly Flammable Refrigerants into a Room

Experiments to Validate the NRCC Smoke Movement Model for Fire Risk-Cost Assessment

Fire Patterns. Introduction. Skills Objectives. Fire Effects and Fire Patterns (2 of 2) 12/20/ Knowledge Objectives

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

FIRE PROTECTION FOR NON-STORAGE OCCUPANCIES WITH HIGH CEILING CLEARANCES

A study for a fire spread mechanism of residential buildings with numerical modeling

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

WATER MIST CONVENTION AND EXHIBITION

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Feasibility Study of Use of Elevators in Fire Evacuation in a High-rise Building

UniVario Industrial Fire Detectors Versatile in Application

Protezione antincendio di dati e business critical assets nei Data Centers

Modeling a real backdraft incident fire

CFD Analysis of Fire Characteristics on Subway Junction Station

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

Experimental Study on Response Sensitivity of Smoke Detectors in High Flow Velocity

Growing Conditions and Crop Performance in High Tunnels

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

Experimental Investigation on the Effection of Flow Regulator in a Multiple Evaporators/Condensers Loop Heat Pipe with Plastic Porous Structure

AMOUNT OF MOISTURE PRODUCED INSIDE BATHROOM AND APPURTENANT CHANGING ROOM

Design & Control of an Elevator Control System using PLC

Automated Fire Detection and Suppression in a Retrofitted Tunnel Using Fiber-Optic Linear Heat Detection

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

So, How do Fire Starts & Spreads? A question we need to understand and appreciate the dynamics of fire life cycle.

ANALYSIS OF THE FIRE FIGHTING ROBOT

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

Assessing HVAC Leak Damage with Infrared

Fire is No Accident Fire is No Accident It can be prevented.

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

Numerical Simulation of Ventilation Efficiency in Commercial Kitchen

1893 Chicago World s Fair

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Fire Prevention. Risk Management Services. October 7-13, 2012 National Fire Prevention Week National Fire Protection Association

Transcription:

Study on Fire Detection at Cultural Assets Buildings with Botanical Roofs HIROYUKI TAMURA, DAISUKE KOZEKI and KUNIHIRO YAMASHITA National Research Institute of Fire and Disaster 3-14-1, Nakahara, Mitaka, Tokyo 181, Japan MASATO AIZAWA Hochiki Corporation 246, Tsuruma, Machida, Tokyo 194, Japan ABSTRACT Burning characteristics of botanical roofs, which are often used for cultural assets buildings in Japan, have been investigated through a series of experiments. Based on the experiments, suitable fire detecting system for such kind of fires are discussed and proposed. The rate-of-rise heat detectors are installed in the attic, on the ceiling and under the eaves, for cultural assets buildings. However, in 30% of fires at cultural assets buildings, fires break out from their roofs and those detectors beneath the roofs are not proved to be suitable for the early detection of such kinds of fires. For the purpose of earlier detection of the roof-fires, a series of fire experiments, in which the roofs are ignited from outward, are conducted and the rate of the fire spread are observed. In the experiments, sensors of various kinds are installed and the response of them are also evaluated. Those experiments reveal that fires on the roof surface can be detected in early smoldering stage by smoke detectors with wind, and temperature rise is only detectable at a point just opposite to the fire point at that time. Flame sensor is proved to be effective to detect roof-fires in very early stage. KEYWORDS : fire detection, cultural assets buildings, wooden house, roof material INTRODUCTION Most of Japanese buildings which are registered as cultural assets are wooden, and 40% of them have roofs thatched with botanical materials. About half of FIRE SAFETY SCIENCE-PROCEEDINGS OF THE FIFTH INTERNATIONAL SYMPOSIUM, pp. 841-852 841 Copyright International Association for Fire Safety Science

cultural assets buildings on fires had botanical roofs and place of an outbreak of fire is roof in 30% of cultural assets buildings fires. Nowadays, for the cultural assets buildings with botanical roofs, rate-of-rise heat detectors are installed in the attic, on the ceiling and under the eaves. These installation methods are suitable for fires inside the building but they are not suitable for roof-surface fires. In order to protect cultural assets buildings from fires. the method to detect roof-surface fires at an early stage must be investigated. We investigated the combustion characteristic of botanical roofs. And considering construction and cost for the automatic alarm system, we studied the technology to detect roof-surface fires more quickly with some detectors which are easy to get. STRUCTURES OF THE BOTANICAL ROOFS THATCHED ROOF Thatched roof consists of dry cogongrasses with 3 to 8mm in diameter and 1.5 to 2m long all over the roof. The thickness of the roof is between 40 and 80cm., a window for a 2680 J a front view 30204 - a side view r 4000 a ground plan I FIGURE 1 Schematic of roof model (unit : mm)

JAPANESE CYPRESS BARK ROOF Japanese cypress bark roof is composed of bark pieces of Japanese cypress. Each piece is about 50cm in length, 20cm in width, and approximately 2mm in thickness. The pieces are piled up from the eaves of the roof with approximately 4cm of shifting. The thickness of the roof ranges for 10 to 15cm. SHINGLE-ROOFED Shingle-roofed is composed of shingle pieces. Each piece is about 40cm in length, 10 to 20cm in width, and approximately 3mm in thickness. The pieces are piled up from the eaves of the roof with approximately 3cm of shifting. The thickness of the roof ranges for 5 to 10cm. DESCRIPTIONS OF THE EXPERIMENTS FlGURE 1 shows a schematic diagram of the structure model used for the experiments. The specifications of sensors are shown in TABLE 1. The sensors were placed as illustrated in FIGURE 2 and FIGURE 3. We tested a variety of detectors in the experiments such as the infrared detector, the ultraviolet detector and photoelectric smoke detector are prepared based on the fire service law of Japan. Photoelectric smoke detector was analog type. Flame sensor was the UVtron-R2868 made by Hamamatsu photonics Co.Ltd., and was sensitive to faint ultraviolet rays from a flame. Thermocouples of type C-4 were used for the measurement of temperature. The infrared detector, the ultraviolet detector and the flame sensor are known generically as flame detectors. The experimental conditions and measured items are listed in TABLE 1. The roof TABLE 1 Experimental conditions and measured items

q- Y. hand rall a ground plan fan I I I a side view FIGURE 2 Experimental set up ( Flame sensor was installed at point 1, the ultraviolet and the infrared detectors were installed at point 2. ) for the experiment was mounted on the thick and black frame illustrated in a ground plan of FIGURE 1. The thatched roof with dimensions of 90cm wide, 200cm long. 40cm thick was made by thatched roof artisan. Japanese cypress bark roof and Shingle-roofed, whose dimensions were 90cm wide, 180cm long. Those roofs were obtained by cutting down from the real cultural assets buildings. To ignite the surface of the roof, charcoal fire was placed at the Point 6 shown in FIGURE 3. The selection of the ignition source was made based on the fact that flying sparks from a bonfire and fireworks are responsible for real roof-surface fires. The thatched roof could not be ignited by the charcoal fire without wind. Therefore fireworks were used in dead calm. The wind was created in front of the structure model using the air blower. The temperature in the attic was monitored by thermocouples. The smoke inflow into the attic was observed by a video camera and smoke detectors. The surface of the roof was observed by the flame detectors and the optical fiber thermometer. The experimental room was spacious and was not air-conditioned. EXPERIMENTAL RESULTS AND DISCUSSION DIFFERENCE IN COMBUSTION CHARACTERISTICS OF EACH ROOF MATERIALS Thatched roof The thatched roof is less ignitable than the other taro types of roof. Under the wind, the thatched roof was ignited by 1.5cm cubic charcoal fire. Without wind, thatched roof could not be ignited by charcoal fire. After the flaming, combustion spread rapidly. In the experiment without wind, the combustion area grown to 0.25m2 within 2 minutes, after flaming. Under the wind, it took several tens of seconds for combustion area to grow to 0.25m2.The flaming area of 0.25mZ is approximate minimum size at which the infrared detector can

wind - FIGURE 3 Schematic diagram of thermocouples and photoelectric smoke detectors ( Thermocouples were installed at point 0 to 9, smoke detectors were installed at point 0 to 3. ) detect the flame at 8m away from the model roof. The combustion tend to spread upward with flaming. The rate of upward fire spread was more than 5 times as rapid as downward spread. And the rate of sideward fire spread was approximately 1 to 1.5 times as rapid as downward speed. Compared with the other kinds of botanical roofs, thatched roof had much more significant flames which caused faster flame spread. Japanese cypress bark roof Japanese cypress bark is easy to smolder because the surface of the bark is fluffy. Japanese cypress bark roof was ignited by 1cm cubic charcoal fire. Under the wind, a flaming on the roof-surface started 3 minutes after the ignition. After the ignition, smoldering area spread with sudden flaming. Smoldering spread was slow. It took 15 to 60 minutes for smoldering area to grow to 0.35m2 after flaming under the wind. Without wind, it took more than 60 minutes for smoldering area to grow to 0.35m2. The combustion area of 0.35m2 is approximate minimum size at which the infrared detector can detect the combustion at 8m away from the roof. The smoldering tend to spread downward. The rate of upward fire spread was 0.1 to 0.5 times as rapid as downward spread and the rate of sideward fire spread was approximately 0.2 to 0.5 times as rapid as downward spread. Because the smoldering tends to spread toward the direction of larger amount of oxygen supply. the combustion spreads downward where the pieces of the bark are less overlapped. Shingle-roofed Shingle was easiest to be ignited between three kinds of the roof materials

tested. Flaming on the shingle-roofed surface started within 3 minutes under the wind of 3mis. To ignite the shingle without the wind, three pieces of 1.5cm cubic charcoal fire were placed continuously. It took 15 to 40 minutes for flaming area to grow to 0.25m2 after flaming under the wind. The flaming area of 0.25m2 is approximate minimum size at which the infrared detector can detect the flame at 8m away from the roof. Without wind, the combustion spread was slow. Because of the slow combustion spread, the infrared detector did not respond during the experiment. The smoldering tend to spread inward. Once a hole was made, the flaming was observed around the hole. Then the combustion spread upward at the both faces of shingle with the flaming. The combustion speeds of every direction were much the same before a hole had been made. After a hole had been made, the rate of upward fire spread was approximately 2 to 3 times as rapid as downward spread. And the rate of sideward fire spread was about 0.7 to 1.5 times as rapid as downward spread. TEMPERATURE AND SMOKE DENSITY PROFILES IN THE ATTIC Thatched roof FIGURE 4 shows the temperature profile at the attic during the fire test with wind. At the place just below thk igniting point, the temperature began to rise 2 minutes after the flaming on the roof-surface. Hot air intruded into the attic vertically, and the flow did not follow the direction of the cogongrasses stalk. It was not affected by the direction of the cogongrasses stalk: as if the flow was forced by the wind outside the roof. Within 2 minutes, temperatures at all observed points exceeded 100 C. The burnt roof area was 0.1m2 and it was flaming when temperature rise of 10 C was observed at just below the flaming = 34100 FIGURE 4 Output signals of thermocouples (test 2 : thatched roof)

igniting point. Because of the rapid flame spread on the roof-surface, the area through which the smoke intrude into the attic was broad and the rate of temperature rise was high. FIGURE 5 shows the change in smoke density in the attic with time. At the experiment with wind. it was revealed that the rise in smoke density was observed about 2 minutes prior to the flaming, during the smoldering stage of combustion. The smoke density exceeded the alarm level of smoke detector(5%/m) about 1 minute prior to the flaming. When the smoke detector gave smoke density of 5%/m, the combustion on the roof-surface was in the smoldering stage. These mean that the smoke intrude into the attic. At the experiment without wind, even if there was no smoldering. the smoke detector gave smoke density of 5%/m when the combustion area grew up to be 0.6mZ. The time when smoke detector gave smoke density of 5%/m was 6 minutes after the flaming on the surface of the roof. This response time was half of the response time of the other roof type. (owing to ignition with fireworks, the fire blazed up with ignition and spread rapidly.) flaming = 34:OO t 3 4 10 0 Y 0 5 " 0 5 10 15 20 25 30 35 40 (a) test 1 wind velocity = O m/s 0 5 10 15 20 25 30 35 40 (b) test 2 wind velocitj~ = 2 mis FIGURE 5 Output of photoelectric smoke detectors ( thatched roof ) Japanese cypress bark roof FIGURE 6 shows the change in tem~erature at the attic during the fire test. At a point 30cm above of thve point ju'st opposite to the fire poini (the backside point), the temperature rose about 5 C before the flaming on the surface of the roof. The burnt roof area was less than O.OlmZ and it was flaming when temperature rise of 10 C was observed at the 30cm above the backside point. After the temperature rose at the 6Ocm above the backside point, the temperature started to rise at the top in the attic. At the both side and below the backside point, there were no striking changes during 7 minutes after the flaming on the roof-surface. These mean that the area where hot air intruded into the attic was narrow. This area was about 60cm long and 40cm wide. FIGURE 7 shows the change in smoke density with time within the attic. At the experiment with wind, it was revealed that the rise in smoke density was

flaming =f:23 100 0 0 100 0 100 / 1 0 100 2 5 0 3 3,o 100-0 4-2 2 I00 4 rj 0 5 $ 6 100 2 6 0 + 100 g 0 7 2 100 0 8 100 0 0 5 10. 9 1.5 time passed after ignition (rnin) FIGURE 6 Output signals of thermocouples ( test 4 : Japanese cypress roof ) - observed about 1 minute prior to the flaming. The smoke density exceed the alarm level of smoke detector(5%/m) about 3 minutes prior to the flaming. When the smoke detector gave a smoke density of 5%/m, the combustion on the surface of the roof was in the flaming stage and the combustion area was less than 0.01m2. At that time, the thermocouple 4 located at 60cm above the 2-1 flaming = 3:23 detector 0 0 20 40 60 80 100 120 (a) test 3 wind velocity = 0 mjs 0 20 40 60 80 100 120 (b) test 4 wind velocity = 3 m/s FIGURE 7 Output of photoelectric smoke detectors ( Japanese cypress roof )

backside point gave 10 C rise in temperature. At the experiment without wind, the smoke density in the attic did not reach an alarm level of the smoke detector even 1 hour after the flaming. Shingle-roofed Temperature profiles measured with thermocouples in the windy case are illustrated in FIGURE 8. The thermocouple at the point 5 gives 10 C rise in temperature. At the time, the burning area on the surface of the roof was less than 0.01m2. The condition of fire was flaming. The thermocouples at point 4 and 6 gave rise of temperature. Then, temperature at point 8, 9 and 0 begun to rise slowly. Owing to this tendency continued till the fire penetrated through the roof, this showed that the burning area spread long elliptically lengthways. The area where heat flow entered was about 60cm long and 40cm wide till the fire penetrated through the roof. Because of the fresh air blown into the attic after the fire penetrated through the roof, temperatures of some points went down. But temperature at top point of the attic (point 0) didn't drop. Change in smoke density in the attic is shown in FIGURE 9. In the windy case, smoke detector caught 5%/m rise of smoke density in 2 minutes after flaming. And more than 1 minute later, the smoke density exceeded the upper measurement limit (25%/m). Then the state of combustion was a flaming fire and burning area was less than 0.01m2. Before the fire penetrate through the roof, a smoke detector can give an alarm. In the windless case, in over 10 minutes after flaming smoke detector caught a rise of 5%/m smoke density and smoke density soon exceeded the upper measurement limit (25%/m). flaming = 1:55 FIGURE 8 Output signals of thermocouples ( test 6 : shingle-roofed )

flaming = 61:56 flaming = 15.5 detector 0 +df 6 ol I.--.I 1; &I 0 10 20 30 40 50 60 70 80 (a) test 5 wind velocity = 0 mls 0 10 20 30 40 50 60 70 80 (b) test 6 wind velocity = 3 m/s FIGURE 9 Output of photoelectric smoke detectors ( shingle-roofed ) RESPONSE OF FLAME DETECTORS We are investigating effective methods to extinguish roof-surface fires now, therefore we evaluate the detectors based on the performance of an early detection. Response times of the infrared detector, the ultraviolet detector and flame sensor set up in the outside is listed in TABLE 2. The infrared and the ultraviolet detector are adjusted not to run by detecting lower intensity of light than the threshold level, to prevent false alarms. The flame sensor caught sudden flaming and ran. As a result, the flame sensor ran faster several minutes to several tens of minutes than the infrared detector and the ultraviolet detector (TABLE 2). And the ultraviolet detector runs faster than the infrared detector. The flame sensor can detect roof surface fire early, but this sensor has a disadvantage that it responds to a noise including ultraviolet rays. This sensor can be used in limited cases. For example, the flame sensor is expected to pre-alarm fires in the system of a building's supervision that is possible to check the spot from pre-alarm. TABLE 2 Response time of flame detectors (minute : second ) test No. flame sensor UV detector IR detector 1 0:05 0:45 1:49 2 34:l 34:l 34:13 3 69:18 116:7 116:33 4 3:23 13:26 16:07 5 6 6156 156 NR 8:43 NR 17:48 NR : not response

CONCLUSIONS CHARACTERISTICS OF COMBUSTION It is difficult to fire the dry cogongrasses. But once flames occurred and blazed up, a fire spreads quickly. Japanese cypress roof keeps on smoldering. While brazing small flames, fire spreads downward the roof-surface. Shingle-roofed's fire keeps on smoldering toward a reverse side of the roof and a smoldering penetrates through the roof. After that fire spreads toward the top of the roof. FIRE DETECTION IN THE ATTIC Fire Detection with smoke detector If there is a head wind, it is possible to detect 5%/m smoke density for fires of all type of the roof mateiials with smoke detectors in an attic. When a smoke density reaches 5%/m, burning are still smoldering fire in the thatched roof and flaming fire in the others. At the detection time the burning area in all types roofs are under 0.01m2. If there is no wind, it is possible to detect 5%/m smoke density for the thatched roof. At this stage, burning area is 0.6m2. In the shingle-roofed, till fire penetrated through the roof, the detector does not run. In the Japanese cypress, it is difficult for the smoke detectors to detect a fire. Fire Detection with temperature in the windy case The thermocouples pick up heat air current from a point just opposite to the fire point to thk 40cm upper point. After that, temperatuie at the top of the attic rise. When some one of the thermocouples in the attic caught 10 C rise in temperature, burning area of the roof-surface is 0.1m2 in thatched roof and 0.01m2 in the other roofs respectively. Because the temperature rose after fire turned from smoldering to flaming in all cases, it is difficult for thermal sensors to detect a smoldering fire. DETECTION FROM THE OUTSIDE OF THE BUILDING Flame sensor activated by the ultraviolet ray from a flame can detect small fires. However, due to lacking of the steps taken for a false alarm, this sensor can be used in limited case. It is that the flame sensor is expected to be used for pre-alarm sensor under the system of building's supervision which is possible to check the spot from pre-alarm. REFERENCES 1. Tamura, H., Takahashi, S., Yamashita, K., Aizawa, M.,I1Study on the Fire Protection Method of Cultural Properties Buildings which are thatched with the Cogongrasses and others (part-2 Fire Detection)", Proceeding of Annual Meeting of the Japan Association for Fire Science and Engineering, pp.8-11,