Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

Similar documents
973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

CSIRO. Oceanographic Calibration Facility. Hobart, Tasmania, Australia. Robert Kay Calibration Engineer June 2017

Simco Calibration Laboratory

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Authentic Instrument & Automation (P) Ltd. Products Presentation. By: Mr. O.P. Singh. X2 Series

PCT Workshop Before you leave the office

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

3.4 Humidity. Types of instruments

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

RENAR Accreditation Activities

Available online Journal of Scientific and Engineering Research, 2017, 4(10): Research Article

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

PQS Independent type-testing protocol

Simple, digital wireless reporting.

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

Contact person Date Reference Page Henrik Andersson F (4) Electronics

GUIDELINE FOR THE APPLICATION OF SRPS CEN/TS WHEN GRANTING ACCREDITATION TO TESTING LABORATORIES

Using the DewTrak II Dew Point/ Humidity Transmitter

CERTIFICATE of Product Conformity (QAL1)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

hvgrometers Humidity Meters humidity meters hygrometers & therma-hygrometers what is a hygrometer? applications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player

Electric radiator test

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Certificate: _01 / 20 August 2013

Temperature and Calibration Capabilities

Temperature and Calibration Capabilities

Annex to the Accreditation Certificate D-ZE according to DIN EN ISO/IEC 17065:2013

CERTIFICATE OF ACCREDITATION

Drawer fronts: 16 mm particleboard Doors: 16 mm particleboard This report covers the models Nonstop, Sprinter, Genese

Instruments. for hydroponics & horticulture 2016

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

INSTRUCTION MANUAL. Pyrheliometer MS-57

PRODUCT CONFORMITY CERTIFICATE

NTC THERMISTOR SENSOR PERFORMANCE

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

WH-1404, Rev. Feb 97

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Temperature sensors for semi conductor & solar industry

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 209/02)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

GE General Eastern Instruments

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

ISO INTERNATIONAL STANDARD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SENSOR SOLUTIONS FOR DOORS

ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 1: Electrical cone and piezocone penetration test

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Thermohygrometer with Single Type K Input and Superheat Function

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Annex of the certificate (Page 1/1) Accreditation Scope

Business Quality Assurance International Ltd

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

CERTIFICATE OF ACCREDITATION

CONFIRMATION of Product Conformity (QAL1)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Weed Instrument The Only Name You Need to Know for Temperature Measurement

HEAD QUARTER NEW JERSEY LBORATORY VIETNAM LABORATORY

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

Southern California Gas Company Customer Programs Department

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005


This document is a preview generated by EVS

2031A Quick Stick User s Guide

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Verification & Testing for Conformity Assessment / EC Verification. NB-Rail (ERTMS Group)

ISO 7491 INTERNATIONAL STANDARD. Dental materials Determination of colour stability. Produits dentaires Détermination de la stabilité de couleur

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

CALIBRATION HOW IT WORKS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

BC-HTO RELIABLE SENSING TECHNOLOGY

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

Polish Centre for Accreditation

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

PQS Independent type-testing protocol

ice 3000 Series Atomic Absorption Spectrometers

CERTIFICATE of Product Conformity (QAL1 )

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Transcription:

Supertron Sensing Pte Ltd Certificate No. : LA-2011-0485-C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore 339156 Date : 04 February 2015 Page : 1 of 5 FIELD OF TESTING : Calibration and Measurement MEASURED QUANTITIES/ INSTRUMENTS / RANGE TO BE CALIBRATED ( CMC * ) 1. Pressure Measuring Devices In-house Procedure, i. Calibrator CP-H, Rev 4 ii. Transducer/ Transmitter iii. Digital Indicator a. (10 to 50) psia 0.025 psia b. (50 to 300) psia 0.06 psia 2. Humidity Measurement In-house Procedure i. Dew/ Frost Point CP-M, Rev 4 a. -90 C to -85 C Frost Point 0.60 C b. -85 C to -75 C Frost Point 0.35 C c. -75 C to -60 C Frost Point 0.20 C d. -60 C to -30 C Frost Point 0.13 C e. -30 C to +70 C Frost/ Dew Point 0.10 C

Date : 04 February 2015 Page : 2 of 5 MEASURED QUANTITIES/ INSTRUMENTS / RANGE TO BE CALIBRATED ii. Relative Humidity (Chilled mirror hygrometer with air Temperature probe) In-house Procedure (CMC * ) Corresponding to above dew-point and temperature uncertainties a. At -10 C (10 to 30) % relative humidity (0.2 to 0.5) % relative humidity (30 to 50) % relative humidity (0.5 to 0.8) % relative humidity (50 to 70) % relative humidity (0.8 to 1.1) % relative humidity b. At 0 C (10 to 30) % relative humidity (0.2 to 0.4) % relative humidity (30 to 50) % relative humidity (0.4 to 0.6) % relative humidity (50 to 70) % relative humidity (0.6 to 0.8) % relative humidity (70 to 95) % relative humidity (0.8 to 1.0) % relative humidity c. At 23 C (30 to 50) % relative humidity (0.3 to 0.5) % relative humidity (50 to 70) % relative humidity (0.5 to 0.7) % relative humidity (70 to 95) % relative humidity (0.7 to 0.8) % relative humidity d. At 50 C (30 to 50) % relative humidity (0.3 to 0.4) % relative humidity (50 to 70) % relative humidity (0.4 to 0.5) % relative humidity (70 to 95) % relative humidity (0.5 to 0.7) % relative humidity e. At 70 C (30 to 50) % relative humidity (0.3 to 0.4) % relative humidity (50 to 70) % relative humidity (0.4 to 0.5) % relative humidity (70 to 95) % relative humidity (0.5 to 0.6) % relative humidity

Date : 04 February 2015 Page : 3 of 5 MEASURED QUANTITIES/ INSTRUMENTS / RANGE TO BE CALIBRATED ( CMC * ) iii. Relative Humidity Sensor/ Instrument In-house Procedure iv. Thermo-hygrometer a. At -10 C (10 to 30) % relative humidity (0.3 to 0.9) % relative humidity (30 to 50) % relative humidity (0.9 to 1.1) % relative humidity (50 to 70) % relative humidity (1.1 to 1.2) % relative humidity (70 to 95) % relative humidity (1.2 to 1.3) % relative humidity b. At 0 C (10 to 30) % relative humidity (0.3 to 0.9) % relative humidity (30 to 50) % relative humidity (0.9 to 1.0) % relative humidity (50 to 70) % relative humidity (1.0 to 1.2) % relative humidity (70 to 95) % relative humidity (1.2 to 1.3) % relative humidity c. At 23 C (10 to 30) % relative humidity (0.3 to 0.8) % relative humidity (30 to 50) % relative humidity (0.8 to 1.0) % relative humidity (50 to 70) % relative humidity (1.0 to 1.1) % relative humidity d. At 50 C (10 to 30) % relative humidity (0.3 to 0.7) % relative humidity (30 to 50) % relative humidity (0.7 to 1.0) % relative humidity (50 to 70) % relative humidity (1.0 to 1.1) % relative humidity e. At 70 C (10 to 30) % relative humidity (0.3 to 0.6) % relative humidity (30 to 50) % relative humidity (0.6 to 0.9) % relative humidity (50 to 70) % relative humidity (0.9 to 1.0) % relative humidity (70 to 95) % relative humidity (1.0 to 1.1) % relative humidity

Date : 04 February 2015 Page : 4 of 5 MEASURED QUANTITIES/ INSTRUMENTS / RANGE TO BE CALIBRATED MEASUREMENT CAPABILITY ( CMC * ) 3. Temperature A. Liquid bath method i. Temperature indicator and Recorders, with temperature sensor(s) ii. Industrial Platinum Resistance Thermometer iii. Thermistor In-house procedure CP-C, Rev 2 a. -196 C 50 mk b. (-80 to +5) C 30 mk c. (+5 to +90) C 30 mk d. (+100 to +250) C 30 mk e. Ice Point, 0 C 10 mk f. (0 to +30) C } Either by Fixed Point or by 10 mk g. Water Triple Point } comparison with SPRT In 10 mk h. Gallium Fixed Point } liquid bath 10 mk B. Air chamber method i. Temperature sensors incorporated in humidity instruments ii. Thermistor In-house procedure a. (-10 to 70) C 0.13 C * CMC is expressed as an expanded uncertainty estimated at a level of confidence of approximately 95%. Approved signatories : Mr Tee Yee Chee @ Mr Zheng Yiqi Ms Eva Marie Barrera

Date : 04 February 2015 Page : 5 of 5 Note : This laboratory is accredited in accordance with the recognised International Standard ISO/IEC 17025:2005. A laboratory's fulfilment of the requirements of ISO/IEC 17025:2005 means the laboratory meets both the technical competence requirements and management system requirements that are necessary for it to consistently deliver technically valid calibration results. The management system requirements in ISO/IEC 17025:2005 (Section 4) are written in language relevant to laboratory operations and meet the principles of ISO 9001:2008 Quality Management Systems Requirements and are aligned with its pertinent requirements.