Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Similar documents
Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

for relative humidity and temperature with calibration certificates

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Room Temperature Sensors

Duct Temperature Sensors

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

for relative humidity and temperature

Duct Air Quality Sensors

for relative humidity and temperature

Room Air Quality Sensors

Room air quality sensors

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QPM21 Series Duct CO 2 and Air Quality Sensors

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Duct Temperature Sensors

Differential pressure sensors

Room Temperature Controller

PRELIMINARY EDITION

Room Temperature Sensors

Semi flush-mount room thermostat

Room Temperature Controller

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Room Temperature Sensor

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Room Temperature Controller with LCD

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Heating Element. Building Technologies HVAC Products

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Self-learning Room Temperature Controller

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Immersion Temperature Controller

Preliminary Release. Room Temperature

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

No. Icon Name Function

Frost Protection Thermostat

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Flame Safeguards LFE10. Building Technologies HVAC Products

Room Temperature Controllers

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

Room thermostats with LCD for wall mounting

BC3250. Blowdown Controller

Flush-mounted room thermostat

Infrared Flame Detectors

Flame Safeguards LFE10. Building Technologies HVAC Products

Room thermostat with Auto Timer, Option External Input

Use. For 2-pipe fan coils

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

LC1350 Level Controller

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

MANDÍK MEASUREMENT AND CONTROL SYSTEM

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Self-learning Room Temperature Controller

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

C Note! LGI16... Burner Controls. Building Technologies

Flame detector. The QRA4.U is for use with the following types of burner control:

Hygro/hygrothermal transducers (hygrometric)

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Room thermostat with Auto Timer, Option External Input

Room Temperature Controller

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Flush-mounted room thermostats

QAW70. Room Unit. Building Technologies. for use with heating controllers

LAE10 LFE10. Use. Series 02

UV Flame Supervision System

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

FR-A180 FR-A360. Occupancy detector. Use

Heating Controller. Building Technologies HVAC Products. Synco 700

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

Wireless room thermostat with LCD

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

RVL481. Heating Controller. including d.h.w. heating

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Wall-mounted room thermostat with LCD

QRA10... QRA53... QRA55...

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

OH720, OP720, HI720, HI722

Self-learning Room Temperature Controller

QRA10... QRA53... QRA55...

RVL479. Heating Controller. for use with a partner unit

1592P01. for liquids in piping DN

Transcription:

1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and temperature Very high measuring accuracy across the entire measuring range Capacitive humidity measurement Range of use 40 +70 C / 0 100 % r h The QFA31 is for use in ventilation and air conditioning plants where high accuracy and short response times for measuring relative humidity are required The measuring range covers the entire humidity range of 0 100 % Examples: Storage and production facilities in the paper, textile, pharmaceutical, food, chemical and electronics industry, etc Laboratories Hospitals Indoor swimming-pools Computer and EDP centers Greenhouses With the AQF3100 accessory for outdoor use CE1N1858en 06012006 Building Technologies HVAC Products

Type summary Type reference measuring range signal output measuring range signal output Operating voltage QFA3100 None None 0100 % Aktive, DC 010 V AC 24 V or DC 135 3 QFA3101 None None 0100 % Aktive, 4 20 ma DC 135 3 QFA3160 050 C / 40 +70 C / 35+ 35 C QFA3171 050 C / 40 +70 C / 35+ 35 C Aktive, DC 010 V 0100 % Aktive, DC 010 V AC 24 V or DC 135 3 Aktive, 4 20 ma 0100 % Aktive, 4 20 ma DC 135 3 Ordering When ordering, please give name and type reference, eg: Room sensor QFA3160 The AQF3100 outdoor mounting kit listed under Accessories must be ordered as a separate item Equipment combinations The QFA31 is for use with all types of systems and devices that can acquire and handle the sensor s DC 010 V or 4 20 ma output signal Technical design Relative humidity The sensor acquires relative humidity via its capacitive sensing element whose capacitance varies as a function of the relative humidity of the ambient air An electronic circuit converts the sensor s signal to a continuous DC 010 V or 4 20 ma signal, corresponding to a relative humidity of 0100 % The sensor acquires the temperature via its sensing element whose electrical resistance varies according to the temperature of the ambient air This variation is converted to an active DC 010 V or 4 20 ma output signal, corresponding to a temperature range of 050 C, 35+35 C, or 40+70 C The measuring range can be selected Burden diagram Output signal, terminai I1 / I2 900 800 1858D02en Burden [Ohm] 700 600 500 400 300 Inadmissible range! Admissible range 200 100 0 0 10 20 30 40 Operating voltage [DC V] 2/6 HVAC Products 06012006

Mechanical design Room sensor QFA31 The room sensor consists of housing, printed circuit board, connection terminals and measuring rod The housing consists of 2 parts: Base and removable cover (screwed) A rubber seal is installed between housing and cover in order to satisfy the requirements of IP 65 degree of protection The measuring circuit and the setting element are accommodated on the printed circuit board inside the cover, the connection terminals in the base Housing and measuring rod are screwed together The sensing elements are located at the end of the measuring rod, protected by a screw-on filter cap The M16 cable entry gland supplied with the sensor can be screwed into the bottom of the base If the sensor is used outdoors, that opening must be closed off and the prepared hole on the opposite side of the base knocked out Setting element Range 1 2 3 Measuring range 123 Test function active U1 U2 I1 I2 10 V 20 ma 10 V 20 ma 0 V 0 V 4 ma 4 ma 1858Z03en The setting element is located inside the cover It consists of 6 pins and a shorting plug It is used for selecting the required temperature measuring range and for activating the test function The different shorting plug positions have the following meaning: For the active temperature measuring range: Shorting plug in the left position (R1) = 35+35 C, Shorting plug in the mid position (R2) = 050 C (factory setting) Shorting plug in the right position (R3) = 40+70 C For the active test function: Shorting plug in the horizontal position: The values available at the signal output are those given in the table Test function active Behavior in the event of fault Outdoor mounting kit AQF3100 If the temperature sensor is faulty, the voltage at signal output U2 (I2) is 0 V (4 ma) after 60 seconds, the humidity signal at signal output U1 (I1) increases to 10 V (20 ma) If the humidity sensor is faulty, the voltage at signal output U1 (I1) is 10 V (20 ma) after 60 seconds; the temperature signal remains active The outdoor mounting kit consists of: 1 wall mounting bracket complete with radiation shield 4 Phillips-head screws K35 x 12 1 grommet M 16 x 15 with O-ring and nut M 16 x 15 for closing off the sensor s cable entry hole if not required Accessories Name Outdoor mounting kit (incl radiation shield) Filter cap (for replacement) Measuring tip (exchangeable for replacement) Type reference AQF3100 AQF3101 AQF3150 HVAC Products 06012006 3/6

Engineering notes Use a safety extra low-voltage (SELV) transformer with separate windings designed for 100 % duty All safety regulations valid at the location of the plant must be observed when sizing and protecting the transformer When sizing the transformer, the sensor s power consumption must be taken into consideration For the electrical connection of the sensor, refer to the Data Sheets of the devices with which the sensor is used The maximum permissible cable lengths must be observed Cable routing and cable selection Note to QFA3171 For cable routing, it should always be considered that electrical interference is the greater, the longer the cables run parallel and the smaller the distance between them Use shielded cables if necessary Twisted pairs of cables are required for the secondary supply lines and the signal lines Terminals G1(+) and I1( ) for the humidity output must always be connected to power, even if only the temperature output G2(+) and I2( ) is used! Mounting notes Interior mounting Mounting location Caution! Mounting position Mounting Instructions Outdoor mounting Mounting location Mounting position Mounting Instructions Note QFA31 without AQF3100 Inside wall (not on outside wall!) of the room to be air conditioned; not in recesses, shelves, behind curtains, above or close to heat sources; not on walls behind which a chimney is located The sensor must not be exposed to direct solar radiation Install the sensor in the occupied space about 15 m above the floor and at least 50 cm from the next wall The seal between housing and cover must not be removed, or else degree of protection IP 65 will be no longer ensured The sensing elements inside the measuring rod are sensitive to shock and impact Avoid any such impact on mounting Without using the AQF3100 outdoor mounting kit, the sensor must not be mounted with the measuring rod pointing upward Mounting Instructions are printed on the sensor s packaging QFA31 with AQF3100 Exterior wall, preferably on the North or Northwestern side of the building; if possible in the middle of the wall, at least 25 above the ground Not above or below windows, above doors and ventilation shafts, below balconies or eaves The sensor with AQF3100 must be mounted in a vertical position (radiation shield at the top) Mounting Instructions are enclosed with the AQF3100 When using the AQF3100 outdoor mounting kit, the sensor s cable entry hole must be closed off with the grommet and the prepared M16 cable entry on the opposite side knocked out Commissioning notes Prior to switching on power, check wiring On the sensor, select the required temperature measuring range 4/6 HVAC Products 06012006

Technical data Power supply Cable lengths for the measuring signal Functional data sensor" Functional data " sensor" Degree of protection Electrical connections Environmental conditions Materials and color Standards Weight Operating voltage Frequency Power consumption AC 24 V ± 20 % or DC 1353 50 / 60 Hz at AC 24 V 1 VA Max perm cable lengths refer to Data Sheet of the device handling the signal Measuring range 0100 % r h Measuring accuracy at 23 C 0100 % rh ± 2 % dependency Time constant 005 % rh/ C approx 20 s in moving air Output signal, linear (terminal U1) DC 010 V 0100 % rh max ± 1 ma Output signal, linear (terminal I1) Burden Measuring range 4 20 ma 0100 % rh refer to "Function" 050 C (R2 = factory setting), 35+ 35 C (R1), 40+70 C (R3) Sensing element Pt 1000 class B to DIN EN 60 751 Measuring accuracy at 1535 C 35+70 C ± 06 K ± 08 K Time constant approx 20 s in moving air Output signal, linear (terminal U2) DC 010 V 050/ 35+ 35/ 40+70 C max ± 1 ma Output signal, linear (terminal I2) Burden 420 ma 050/ 35+ 35/ 40+70 C refer to "Function" Housing IP 65 to IEC 529 Safety class III to EN 60 730 Screw terminals 1 25 mm 2 or 2 15 mm 2 Cable entry gland (enclosed) M 16 x 15 Operation to Climatic conditions (housing with electronics) Mechanical conditions Transport to Climatic condition Mechanical conditions Base Housing cover Scale Filter cap Mounting bracket Sensor (entirely) Packaging Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Immunity Emissions conformity to conformity to Australian EMC framework Radio Interference Emission Standard -Konformität UL 873 Incl packaging 0152 kg IEC 721-3-3 class 4K2 40+ 70 C 0100 % rh (with condensation) class 3M2 IEC 721-3-2 class 2K3 25+ 70 C < 95 % rh class 2M2 polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7035 (light-grey) polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7001 (silver-grey) PA, RAL 7035 (light-grey) silicon-free corrugated cardboard EN 61 000-6-1 EN 61 000-6-3 EMC directive 89/336/EEC Radio Communication Act 1992 AS / NZS 3548 5/6 HVAC Products 06012006

Connection terminals QFA3100 QFA3101 QFA3160 QFA3171 G G0 (rh) U1 1858G04 G1 (rh) I1 1858G05 G (R1 = 35+35 C / R2 = 050 C / (rh) R3 = 40+70 C) G0 U1 U2 1858G01 G1 (rh) I1 G2 (R1 = 35+35 C / R2 = 050 C / R3 = 40+70 C) I2 G, G0 Operating voltage AC 24 V (SELV) or DC 1353 G1, G2 Operating voltage DC 1353 U1 Signal output DC 010 V for relative humidity 0100 % U2 Signal output DC 010 V for temperature range 050 C / 40 +70 C / 35+ 35 C I1 Signal output 4 20 ma for relative humidity 0100 % I2 Signal output 4 20 ma for temperature range 050 C / 40 +70 C / 35+ 35 C 1858G03 Dimensions (all dimensions in mm) Note on connection terminals of the QFA3171: Terminals G1(+) and I1 ( ) for the humidity output must always be connected to power, even if only the temperature output G2 (+) and I2 ( ) is used! QFA31 84 60 80 39 28 M 16 x 1,5 10,5 41 AQF3150 62,8 Bohrplan 1858M01 ø 15 14,5 QFA31 with AQF3100 40 49 10,7 66 104 89 44 36 5,3 30 135 36 22 44 193 50 58 28 66 M 16 x 1,5 Drilling plan 1858M02 6/6 2006 Siemens Switzerland Ltd Subject to change HVAC Products 06012006