OUR TRUSTED SERVICE & SUPPORT

Similar documents
CIRCULAIRE LAMINAR AIR FLOW

Quick Reference Guide to Cabinet types

Laboratory Automation & Robotic System Enclosures

CIRCULAIRE FORMALIN CONTAINMENT SYSTEMS.

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Class II ECO Generation 8 Microbiological Safety Cabinet

Gelaire BH-EN and UltraSafe cabinets

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Laminar Flow Cabinets eco air V

Aero Biotechniques.

Pharmacy Solution Set


LABORATORY CABINETS 103

Theatre Classification and Air Particle Count Is that Surveillance?

OPERATION AND MAINTENANCE MANUAL

HORIZONTAL LAMINAR FLOW CABINET

Howorth Air Technology. Pharmaceutical Containment Solutions

Clarification Proposal Annex 1, PDA: A Global. Cleanroom and. Association. Clean Air Devices. Hasim Solmaz Lighthouse Worldwide Solutions

The overview of standard of equipments used in asbestos removal Naroo Lee, Ph.D./Department of work environment

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Innovation in air purification unmatched air quality

Aseptic Barrier Systems

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

L a b o r a t o r y E q u i p m e n t C a t a l o g

CLEAN AIR SYSTEM.

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Commercial. Tel:

Microbiological Safety Cabinets

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Biological Safety Cabinets or Fume Hoods Which one to use?

Precision Containment for All Applications

PRODUCT LINE ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR PRODUCTS LAMINAR AIR FLOW WORK STATION: (Vertical and Horizontal) Construction made

Howorth Air Technology. Pharmaceutical Containment Solutions

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Control of Biological Hazards

ADVANCED 247 Link Walk, Eastfield, Scarborough, YO11 3LR. 24 Hour Line:

TOPAIR CLEAN AIR SOLUTIONS CATALOG

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

Maximum protection for your health and well-being

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

James Scott & Sons. Price List Excludes Delivery & VAT. (Kitchen Equipment) LTD. Valid 2015 Issued March

Electrical Safety Policy and Management System

ENVAIR lab CO2 Tri-Gas Incubator

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

Advanced Fire Rated Ductwork Solutions

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

LAMINAR FLOW FOR ALL YOUR NEEDS

Clean Room Solutions 2013

Safely Using a Centrifuge Near a Biological Safety Cabinet in Your Cell Culture Laboratory

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Advanced Radiation Measurement Solutions

Fume Hood Safety TYPES OF FUME HOODS

L234 test report compliance to EN 12469

ENVAIR lab CO2 Incubator

Down flow clean air cabinet Star of the Universe. Fortuna

Microbiological Safety Cabinets

Pre Audit Checklist Be prepared and confident that you are 100% compliant!

Contamination Control for Electronic and Semiconductor Applications

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Your specialist partner for total electrical compliance. Electrical Testing

Environmental Health and Safety Biological Safety Program Guidance Document

Stainless Steel Sanitary Ware

Electrostatic Precipitator

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

BioSafety Cabinet- Class 100

Safe Operating Procedure (Revised 2/10)

BioMAT 2 Safety Cabinet

Industrial Air Purification Guide

Biological Safety Cabinets. Biological Safety Cabinets

Equipment guide for local exhaust ventilation (LEV)

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

GROUNDS SERVICES COVERING EVERY ASPECT OF GROUNDS MAINTENANCE, LANDSCAPING AND DESIGN.

Downstream Equipment. Intelligent Air Technology

Cleanroom Technology. Complete solutions for pharmacies.

DOWNDRAFT BENCH SERIES

GROUNDS SERVICES COVERING EVERY ASPECT OF GROUNDS MAINTENANCE, LANDSCAPING AND DESIGN.

Secuflow laboratory fume cupboards

LAMINAR FLOW AND VENTILATED SOLUTIONS FOR ALL YOUR NEEDS

Aspirating Smoke Detection for Duct Monitoring

Contamination Control for Life Science Applications

DUST AND FUME COLLECTOR FOR THERMAL CUTTING AND WELDING APPLICATIONS

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

The best technical solution for high powder concentrations High level filtering surface and compact design Heavy duty construction for long life in

Secuflow laboratory fume cupboards

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

technical specification smoke venting systems

Appendix A.4.1. Safe Fume Hood User Guide

ESPAIR E AIRTM ESPA ESPAIRTM. Kitchen Exhaust Air Treatment System KET Series.

Laboratory Fume Cupboards

INCREASE YOUR LAB EFFICIENCY

Temporary Bridging. Issue 2

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

and Maintenance Services Daily Contract Cleaning

Transcription:

THE MARKET LEADER IN CLEAN AIR SOLUTIONS OUR TRUSTED SERVICE & SUPPORT Service Solutions to cater for our clients specific needs Our Service Department provide ongoing support, calibration and certification to all of our own and other manufacturers to comply with all BS/EN Standards. We advise on product suitability for changes of application or arrange maintenance visits to ensure your investment remains in perfect working order. Our range of service solutions caters for client specific needs, from single visits to long term service contracts covering multiple sites all over the UK & Ireland. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk

THE MARKET LEADER IN CLEAN AIR SOLUTIONS SERVICE OPTIONS STANDARD SERVICE: SERVICE CONTRACTS: Single Visit* to Service, Calibrate and Certify your Clean Air Solution. Visit Check Interior & Exterior condition. Check Access Flaps and Hinges. Check all Service Provisions. Check Light source / switches. Measure airflow at aperture and calibrate if necessary. Check Carbon/HEPA Filter monitoring system. Check Carbon Filters using Gastec monitoring system, or HEPA Filters using DOP testing. Replace Carbon or HEPA Filters if necessary.** Replace Pre-Filter(s).*** Check fan operation. Check all seals. Internal & external clean down. Record results on record card. Standard Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. * Minimum requirement under COSHH regulations. ** From Customer Stock. *** From Monmouth Stock for Fume Cupboards ONLY. WE ALSO OFFER Supply: Carbon Filters of any blend. H13, H14 & U15 HEPA Filters. Pre-Filters. Replace: Replacement lights and fitments. Replacement control panels and electrical installations. Any consumables for any manufacturers. CERTIFICATION REGULATIONS Fume Cabinets/LEV: Tested in accordance with BS 7989. Laminar Flow: Tested in accordance with ISO 14644-3 (2005) and BS EN 1822. Microbiological Safety Cabinets: Tested in accordance with BS EN ISO 14644-3 (2005). KI Discus Operational Performance: Optional test and is carried out in accordance with BS EN 12469 (2000). Cleanrooms: Tested in accordance with BS EN ISO 14644. All Schools Cabinets: Tested in accordance with Building Bulletin 88 and CLEAPS.

THE MARKET LEADER IN CLEAN AIR SOLUTIONS SERVICE & SUPPORT FUME CABINETS How are your Filtration Fume Cabinets serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. electrics. Airflow velocity check. Containment test. Carbon Filter Saturation Test - using Propanol and hotplate* Particulate Filter Test - using smoke generator and photometer*. Tests marked with* are required in BS Standard but are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk

THE MARKET LEADER IN CLEAN AIR SOLUTIONS FILTRATION FUME CABINETS TESTING SCHEDULE: SERVICE CONTRACTS: Interior & Exterior condition checked. Access flaps and hinges checked. Lights & Switches checked. Fan condition checked. All seals checked. Pre-filters replaced if necessary. Carbon Filter monitoring system checked. Carbon Filter challenged by Gastec monitoring system. HEPA filters, where present challenged by DOP smoke test. Main Filters Replaced * Airflow velocities are checked. Air visualisation. Test on alarms if present. Checking all work surfaces. Issue a certificate on all test results. Service record kept on database. Standard Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safe guard your employees. Service card updated and kept on cabinet. * Where necessary, from Customer Stock. CERTIFICATION REGULATIONS Fume Cabinets: Tested in accordance with BS 7989.

SERVICE & SUPPORT THE MARKET LEADER IN CLEAN AIR SOLUTIONS CLASS II BIOSAFETY How are your Class II Biological Safety Cabinets serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. electrics. Airflow velocity check. Containment test. KI Discus Operator/Aperture Protection Performance Test*. DOP Test - using smoke generator and photometer*. Particulate Test - using Particle Counter*. Tests marked with* are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk

THE MARKET LEADER IN CLEAN AIR SOLUTIONS CLASS II BIOLOGICAL SAFETY CABINETS TESTING SCHEDULE: SERVICE CONTRACTS: Interior & Exterior condition checked. Lights & Switches checked. Standard Fan condition checked. All seals checked. KI Discus Operator/Aperture Protection Per formance Test. Carbon Filter monitoring system checked. HEPA filters, where present challenged by DOP smoke test. Main Filters Replaced * Air flow velocities are checked. Air Cleanliness Test - using Particle Counter. Test of alarms if present. Checking all work sur faces. Issue a certificate on all test results. Service record kept on database. Service card updated and kept on cabinet. Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safe guard your employees. * Where necessary, from Customer Stock. CERTIFICATION REGULATIONS Biological Safety Cabinets: Tested in accordance with BS EN ISO 14644-3 (2005). KI Discus Operational Per for mance: Optional test and is carried out in accordance with BS EN 12469: (2000). www.monmouthscientific.co.uk info@monmouthscientific.co.uk +44 (0)1278 458090

SERVICE & SUPPORT THE MARKET LEADER IN CLEAN AIR SOLUTIONS LAMINAR FLOW How are your Laminar Flow Cabinets serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. electrics. Airflow velocity check. HEPA filters challenged by DOP smoke test* and photometer*. Particle counts are taken to ascertain ISO cleanliness standard achieved*. Air Visualisation test. Tests marked with* are required in the BS/EN Standard but are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk

THE MARKET LEADER IN CLEAN AIR SOLUTIONS VERTICAL & HORIZONTAL LAMINAR FLOW TESTING SCHEDULE: SERVICE CONTRACTS: Visit Standard Interior & Exterior condition checked. Access flaps and hinges checked. Lights & Switches checked. Fan condition checked. All seals checked. Pre-filters replaced if necessary*. HEPA filter replaced if necessary*. Particle counts taken to ascertain ISO cleanliness standard. HEPA filters challenged by DOP smoke test. Air flow velocities are checked. Test on alarms if present. Checking all work sur faces. Issue a certificate on all test results. Service record kept on database. Service card updated and kept on cabinet. Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safeguard your employees. * From Customer Stock. CERTIFICATION REGULATIONS Laminar Flow: Tested in accordance with ISO 14644-3 (2005) and BS EN 1822. www.monmouthscientific.co.uk info@monmouthscientific.co.uk +44 (0)1278 458090

THE MARKET LEADER IN CLEAN AIR SOLUTIONS SERVICE & SUPPORT CLEANROOMS How is your ISO Class Cleanroom validated and serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. interior and exterior condition. Particle Counts typically taken every 6m 2* with at lest 10 per room using a caliberated 1l/min instrument. Pressure Differential between rooms checked. Written Report produced and sent to ensure compliance with ISO Standards. Tests marked with* are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in ISO Class Modular and PIR Cleanrooms, Filtration Fume Cabinets, Laminar Flow and Biological Safety Cabinetss. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk www.monmouthscientific.co.uk info@monmouthscientific.co.uk +44 (0)1278 458090

THE MARKET LEADER IN CLEAN AIR SOLUTIONS ISO CLASS CLEANROOMS TESTING & VALIDATION SCHEDULE: CERTIFICATE OF PERFORMANCE EXAMPLE: Interior & Exterior condition checked. Lights & Switches checked. Doors, Runners/Hinges checked. Room Intergity inc. seals checked. Fan and Clean Air Module (CAM) conditions checked. Pre and Main Filters Replaced * Air Room Changes per hour recorded. Pressure Differential checked & recorded. Particle counts recorded and ISO Standard achieved by Cleanroom. CAM Air flow checked. Low Air flow Alarm checked. Issue Test Result Certificate. Service card updated and kept in Cleanroom. * Where necessary, from Customer Stock. We pride ourselves on offering the most comprehensive service to safe guard your employees. CERTIFICATION REGULATIONS Cleanrooms: Tested in accordance with BS EN ISO 14644. www.monmouthscientific.co.uk info@monmouthscientific.co.uk +44 (0)1278 458090

SERVICE & SUPPORT THE MARKET LEADER IN CLEAN AIR SOLUTIONS DOWNFLOW How are your Downflow Units serviced? Tests that should be carried out and recorded as standard in accordance with COSHH regulations include: Overall inspection, inc. electrics and other services. Airflow Test across work-surface. Carbon Filters challenged with GASTEC test where fitted*. HEPA filters challenged*. Filter Saturation Alarm Test. Ventilated Sink Airflow Test. Macerator Operation Check. Tests marked with* are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk

THE MARKET LEADER IN CLEAN AIR SOLUTIONS DOWNFLOW WORKBENCHES & STATIONS TESTING SCHEDULE: SERVICE CONTRACTS: Checks Include: Interior & Exterior condition. Access Flaps and Hinges. Electrical Systems. Fan condition. Alarm System. All Seals. All Work Surface conditions. Carbon Filters challenged. HEPA filters challenged. Filters replaced if necessary* Airflow velocities tested and verified. Test of alarms if present. Checking all work surfaces. Issue a certificate on all test results. Service record kept on database. Service card updated and kept on cabinet. Standard Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safe guard your employees. * From Customer Stock. CERTIFICATION REGULATIONS Downflow: Tests in accordance with COSHH regulations.

THE MARKET LEADER IN CLEAN AIR SOLUTIONS SERVICE & SUPPORT DUCTED CABINETS How are your Ducted Fume Cabinets serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. electrics. Airflow velocity check. Visual inspection of Ductwork Air Visualisation test. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk

THE MARKET LEADER IN CLEAN AIR SOLUTIONS DUCTED FUME CABINETS TESTING SCHEDULE: SERVICE CONTRACTS: Interior & Exterior condition checked. Access flaps and hinges checked. Lights & Switches checked. Fan condition checked. All seals checked. Airflow velocities are checked. Air visualisation. Test on alarms if present. Checking all work surfaces. Airflow changes per hour within cabinet recorded. Check Sash, Windows and Pulleys, where present. Visual inspection of Ductwork. Issue a certificate on all test results. Service record kept on database. Service card updated and kept on cabinet. Standard Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safeguard your employees. CERTIFICATION REGULATIONS Fume Cabinets: Tested in accordance with BS EN 14175 (2006).