THE MARKET LEADER IN CLEAN AIR SOLUTIONS OUR TRUSTED SERVICE & SUPPORT Service Solutions to cater for our clients specific needs Our Service Department provide ongoing support, calibration and certification to all of our own and other manufacturers to comply with all BS/EN Standards. We advise on product suitability for changes of application or arrange maintenance visits to ensure your investment remains in perfect working order. Our range of service solutions caters for client specific needs, from single visits to long term service contracts covering multiple sites all over the UK & Ireland. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk
THE MARKET LEADER IN CLEAN AIR SOLUTIONS SERVICE OPTIONS STANDARD SERVICE: SERVICE CONTRACTS: Single Visit* to Service, Calibrate and Certify your Clean Air Solution. Visit Check Interior & Exterior condition. Check Access Flaps and Hinges. Check all Service Provisions. Check Light source / switches. Measure airflow at aperture and calibrate if necessary. Check Carbon/HEPA Filter monitoring system. Check Carbon Filters using Gastec monitoring system, or HEPA Filters using DOP testing. Replace Carbon or HEPA Filters if necessary.** Replace Pre-Filter(s).*** Check fan operation. Check all seals. Internal & external clean down. Record results on record card. Standard Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. * Minimum requirement under COSHH regulations. ** From Customer Stock. *** From Monmouth Stock for Fume Cupboards ONLY. WE ALSO OFFER Supply: Carbon Filters of any blend. H13, H14 & U15 HEPA Filters. Pre-Filters. Replace: Replacement lights and fitments. Replacement control panels and electrical installations. Any consumables for any manufacturers. CERTIFICATION REGULATIONS Fume Cabinets/LEV: Tested in accordance with BS 7989. Laminar Flow: Tested in accordance with ISO 14644-3 (2005) and BS EN 1822. Microbiological Safety Cabinets: Tested in accordance with BS EN ISO 14644-3 (2005). KI Discus Operational Performance: Optional test and is carried out in accordance with BS EN 12469 (2000). Cleanrooms: Tested in accordance with BS EN ISO 14644. All Schools Cabinets: Tested in accordance with Building Bulletin 88 and CLEAPS.
THE MARKET LEADER IN CLEAN AIR SOLUTIONS SERVICE & SUPPORT FUME CABINETS How are your Filtration Fume Cabinets serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. electrics. Airflow velocity check. Containment test. Carbon Filter Saturation Test - using Propanol and hotplate* Particulate Filter Test - using smoke generator and photometer*. Tests marked with* are required in BS Standard but are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk
THE MARKET LEADER IN CLEAN AIR SOLUTIONS FILTRATION FUME CABINETS TESTING SCHEDULE: SERVICE CONTRACTS: Interior & Exterior condition checked. Access flaps and hinges checked. Lights & Switches checked. Fan condition checked. All seals checked. Pre-filters replaced if necessary. Carbon Filter monitoring system checked. Carbon Filter challenged by Gastec monitoring system. HEPA filters, where present challenged by DOP smoke test. Main Filters Replaced * Airflow velocities are checked. Air visualisation. Test on alarms if present. Checking all work surfaces. Issue a certificate on all test results. Service record kept on database. Standard Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safe guard your employees. Service card updated and kept on cabinet. * Where necessary, from Customer Stock. CERTIFICATION REGULATIONS Fume Cabinets: Tested in accordance with BS 7989.
SERVICE & SUPPORT THE MARKET LEADER IN CLEAN AIR SOLUTIONS CLASS II BIOSAFETY How are your Class II Biological Safety Cabinets serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. electrics. Airflow velocity check. Containment test. KI Discus Operator/Aperture Protection Performance Test*. DOP Test - using smoke generator and photometer*. Particulate Test - using Particle Counter*. Tests marked with* are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk
THE MARKET LEADER IN CLEAN AIR SOLUTIONS CLASS II BIOLOGICAL SAFETY CABINETS TESTING SCHEDULE: SERVICE CONTRACTS: Interior & Exterior condition checked. Lights & Switches checked. Standard Fan condition checked. All seals checked. KI Discus Operator/Aperture Protection Per formance Test. Carbon Filter monitoring system checked. HEPA filters, where present challenged by DOP smoke test. Main Filters Replaced * Air flow velocities are checked. Air Cleanliness Test - using Particle Counter. Test of alarms if present. Checking all work sur faces. Issue a certificate on all test results. Service record kept on database. Service card updated and kept on cabinet. Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safe guard your employees. * Where necessary, from Customer Stock. CERTIFICATION REGULATIONS Biological Safety Cabinets: Tested in accordance with BS EN ISO 14644-3 (2005). KI Discus Operational Per for mance: Optional test and is carried out in accordance with BS EN 12469: (2000). www.monmouthscientific.co.uk info@monmouthscientific.co.uk +44 (0)1278 458090
SERVICE & SUPPORT THE MARKET LEADER IN CLEAN AIR SOLUTIONS LAMINAR FLOW How are your Laminar Flow Cabinets serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. electrics. Airflow velocity check. HEPA filters challenged by DOP smoke test* and photometer*. Particle counts are taken to ascertain ISO cleanliness standard achieved*. Air Visualisation test. Tests marked with* are required in the BS/EN Standard but are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk
THE MARKET LEADER IN CLEAN AIR SOLUTIONS VERTICAL & HORIZONTAL LAMINAR FLOW TESTING SCHEDULE: SERVICE CONTRACTS: Visit Standard Interior & Exterior condition checked. Access flaps and hinges checked. Lights & Switches checked. Fan condition checked. All seals checked. Pre-filters replaced if necessary*. HEPA filter replaced if necessary*. Particle counts taken to ascertain ISO cleanliness standard. HEPA filters challenged by DOP smoke test. Air flow velocities are checked. Test on alarms if present. Checking all work sur faces. Issue a certificate on all test results. Service record kept on database. Service card updated and kept on cabinet. Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safeguard your employees. * From Customer Stock. CERTIFICATION REGULATIONS Laminar Flow: Tested in accordance with ISO 14644-3 (2005) and BS EN 1822. www.monmouthscientific.co.uk info@monmouthscientific.co.uk +44 (0)1278 458090
THE MARKET LEADER IN CLEAN AIR SOLUTIONS SERVICE & SUPPORT CLEANROOMS How is your ISO Class Cleanroom validated and serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. interior and exterior condition. Particle Counts typically taken every 6m 2* with at lest 10 per room using a caliberated 1l/min instrument. Pressure Differential between rooms checked. Written Report produced and sent to ensure compliance with ISO Standards. Tests marked with* are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in ISO Class Modular and PIR Cleanrooms, Filtration Fume Cabinets, Laminar Flow and Biological Safety Cabinetss. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk www.monmouthscientific.co.uk info@monmouthscientific.co.uk +44 (0)1278 458090
THE MARKET LEADER IN CLEAN AIR SOLUTIONS ISO CLASS CLEANROOMS TESTING & VALIDATION SCHEDULE: CERTIFICATE OF PERFORMANCE EXAMPLE: Interior & Exterior condition checked. Lights & Switches checked. Doors, Runners/Hinges checked. Room Intergity inc. seals checked. Fan and Clean Air Module (CAM) conditions checked. Pre and Main Filters Replaced * Air Room Changes per hour recorded. Pressure Differential checked & recorded. Particle counts recorded and ISO Standard achieved by Cleanroom. CAM Air flow checked. Low Air flow Alarm checked. Issue Test Result Certificate. Service card updated and kept in Cleanroom. * Where necessary, from Customer Stock. We pride ourselves on offering the most comprehensive service to safe guard your employees. CERTIFICATION REGULATIONS Cleanrooms: Tested in accordance with BS EN ISO 14644. www.monmouthscientific.co.uk info@monmouthscientific.co.uk +44 (0)1278 458090
SERVICE & SUPPORT THE MARKET LEADER IN CLEAN AIR SOLUTIONS DOWNFLOW How are your Downflow Units serviced? Tests that should be carried out and recorded as standard in accordance with COSHH regulations include: Overall inspection, inc. electrics and other services. Airflow Test across work-surface. Carbon Filters challenged with GASTEC test where fitted*. HEPA filters challenged*. Filter Saturation Alarm Test. Ventilated Sink Airflow Test. Macerator Operation Check. Tests marked with* are often omitted to save costs by some service companies. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk
THE MARKET LEADER IN CLEAN AIR SOLUTIONS DOWNFLOW WORKBENCHES & STATIONS TESTING SCHEDULE: SERVICE CONTRACTS: Checks Include: Interior & Exterior condition. Access Flaps and Hinges. Electrical Systems. Fan condition. Alarm System. All Seals. All Work Surface conditions. Carbon Filters challenged. HEPA filters challenged. Filters replaced if necessary* Airflow velocities tested and verified. Test of alarms if present. Checking all work surfaces. Issue a certificate on all test results. Service record kept on database. Service card updated and kept on cabinet. Standard Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safe guard your employees. * From Customer Stock. CERTIFICATION REGULATIONS Downflow: Tests in accordance with COSHH regulations.
THE MARKET LEADER IN CLEAN AIR SOLUTIONS SERVICE & SUPPORT DUCTED CABINETS How are your Ducted Fume Cabinets serviced? Tests that should be carried out and recorded as standard include: Overall inspection, inc. electrics. Airflow velocity check. Visual inspection of Ductwork Air Visualisation test. Monmouth completes as STANDARD on all Service visits. UK NATIONWIDE SERVICE FULL SOLUTION TESTING ISO 9001 CERTIFIED QUALIFIED ENGINEERS ABOUT US Monmouth Scientific are the UK s leading designers, manufacturers and suppliers of Clean Air Solutions. We specialise in Filtration and Ducted Fume Cabinets installations alongside Laminar Flow and Biological Safety Cabinets. For a no obligation review of your current site facilities and a detailed quotation Contact our Experienced Team; call 01278 458090 or email info@monmouthscientific.co.uk
THE MARKET LEADER IN CLEAN AIR SOLUTIONS DUCTED FUME CABINETS TESTING SCHEDULE: SERVICE CONTRACTS: Interior & Exterior condition checked. Access flaps and hinges checked. Lights & Switches checked. Fan condition checked. All seals checked. Airflow velocities are checked. Air visualisation. Test on alarms if present. Checking all work surfaces. Airflow changes per hour within cabinet recorded. Check Sash, Windows and Pulleys, where present. Visual inspection of Ductwork. Issue a certificate on all test results. Service record kept on database. Service card updated and kept on cabinet. Standard Single Annual Service Visit. Mechanical Fault Call Outs**. ** Excludes all parts. Comprehensive Single Annual Service Visit. Mechanical Fault Call Outs. Includes all parts***. *** Excludes Consumables. All services carried out by our skilled and qualified engineers. We pride ourselves on offering the most comprehensive service to safeguard your employees. CERTIFICATION REGULATIONS Fume Cabinets: Tested in accordance with BS EN 14175 (2006).