A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism

Similar documents
This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

Independent, accredited testing station Member laboratory of STL and LOVAG

CONTENTS AUTOMATIC TRANSFER SWITCHES

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Procedure for the Approval of New Fire Detection and Alarm Technologies

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

HIGH -VOLTAGE SWITCHGEAR AND

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

SECTION AUTOMATIC TRANSFER SWITCHES

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Guide Specification Model CTG Automatic Transfer Switch

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Test Report. Appliance EMF Testing

SECTION AUTOMATIC TRANSFER SWITCHES

Vibration tests on a TNAML Luminaire

Glass fibre rovings - Non-metallic materials

Robotic Mowers (battery powered and charging station connected to electric mains or low voltage supply)

Safety requirements for voltage testing instruments

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

Coatings for protection of FRP structures with heavy rain erosion loads

On Electromagnetic Compatibility

SWITCHGEAR, BUSBAR SYSTEMS and ITS BUILT-IN COMPONENTS: SOMETHING IS MISSING IN IEC and IEEE STANDARDS

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Major Fault Caused by Stator Winding Circuit Ring Failure

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Conformity assessment procedures for the Alarm Components Scheme

IEC Type Test Report Report No. EU1120-HR Type PDV 100 Polymer Arrester 10,000 A Line Discharge Class 1

SECTION AUTOMATIC TRANSFER SWITCHES

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

AUGUST 2016 CONTENTS:

Automation, Software und Informationstechnologie

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Rules for Classification and Construction Additional Rules and Guidelines

EU-Type Examination Certificate

Datasheet - MZM 100 ST2-1P2PWREM-A

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Datasheet - MZM 100 ST-SD2PREM-A

HIGH-VOLTAGE CABLE TESTING: TYPE TEST EXPERIENCES AND NEW INSIGHTS INTO PRE-QUALIFICATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Substations and high voltage installations exceeding 1 kv a.c.

Datasheet - MZM 100 B ST2-SD2PREM-A

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D

Exp, pressurized systems

OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N)

NEMA Standards Publication ICS (R 2007) Adjustable Speed Electrical Power Drive Systems

ETSI TS V1.2.1 ( )

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Alarms Manual. ver.1 rev.06/'07. Enclosures to Service Manuals of: McbNET Digital TM Magnum400 TM MiniMagnum400 TM. 6) Speeder One

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

INTERNATIONAL STANDARD

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Thermostat RT. Data sheet

Draft ES V1.1.1 ( )

INTERNATIONAL STANDARD

Moulded case circuit brakers

PQS Independent type-testing protocol

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

Proservo NMS5- / NMS7-

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

TYPE APPROVAL CERTIFICATE

INTERNATIONAL STANDARD

Shipboard incinerators with capacities up to 4000 kw

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

CNBOP-PIB Standard Fire Protection

Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD)

Chain saws (electric mains powered and battery powered)

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

PQS Independent type-testing protocol

SOUND RECEPTION SYSTEM

FALCON SERIES 12 METAL CLAD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

This document is a preview generated by EVS

AO Annunciator Module

M15051) INSTRUCTION MANUAL

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

Commandant United States Coast Guard

TYPE APPROVAL CERTIFICATE

Lawnmowers (pedestrian controlled electric mains-powered)

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

GMA Panels with double busbar

Lloyd s Register Type Approval System Test Specification Number 3

C Note! LGI16... Burner Controls. Building Technologies

ISO INTERNATIONAL STANDARD

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

This document is a preview generated by EVS

OPERATING INSTRUCTIONS COP-F (ANSI 81O/81U)

MPE TEST REPORT 2APNR-GW631Q R1805A0254-M1V1

BRL-K602. Datum Evaluation Guideline

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

GROUNDING AVOIDANCE SYSTEM (GAS)

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Transcription:

Object A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism 2153-16 Type TCB 145-40-31 Serial No. 16000702, 16000703 Rated voltage 145 kv Rated normal current 3150 A Rated short-circuit current 40 ka Rated frequency 50/60 Hz Manufacturer Client Tested by Qingdao TGOOD Electric Co., Ltd., Qingdao, China *) Qingdao TGOOD Electric Co., Ltd., Qingdao, China KEMA Nederland B.V., Arnhem, The Netherlands Date of tests 30 and 31 May, 2, 7, 10, 15, 17, 20, 28 and 29 June 2016 The object, constructed in accordance with the description, drawings and photographs incorporated in this Certificate, has been subjected to the series of proving tests in accordance with IEC 62271-100 (2012) subclauses 6.6 (STC), 6.102 to 6.106 (T10, T30, T60, T100), 6.109 (SLF), 6.108 (DEF) and 6.110 (Out-of-phase). This Certificate has been issued by DNV GL following exclusively the STL Guides. The results are shown in the record of proving tests and the oscillograms attached hereto. The values obtained and the general performance are considered to comply with the above standard and to justify the ratings assigned by the manufacturer as listed on page 10. This Certificate applies only to the object tested. The responsibility for conformity of any object having the same type references as that tested rests with the Manufacturer. *) as declared by the manufacturer This Certificate consists of 655 pages in total. KEMA Nederland B.V. J.P. Fonteijne Executive Vice President KEMA Laboratories Arnhem, 12 August 2016 Copyright: Only integral reproduction of this Certificate is permitted without written permission from DNV GL. Electronic copies as PDF or scan of this Certificate may be available and have the status for information only. The sealed and bound version of the Certificate is the only valid version.

-2-2153-16 INFORMATION SHEET 1 KEMA Type Test Certificate A KEMA Type Test Certificate contains a record of a series of (type) tests carried out in accordance with a recognized standard. The object tested has fulfilled the requirements of this standard and the relevant ratings assigned by the manufacturer are endorsed by DNV GL. In addition, the object s technical drawings have been verified and the condition of the object after the tests is assessed and recorded. The Certificate contains the essential drawings and a description of the object tested. A KEMA Type Test Certificate signifies that the object meets all the requirements of the named subclauses of the standard. It can be identified by gold-embossed lettering on the cover and a gold seal on its front sheet. The Certificate is applicable to the object tested only. DNV GL is responsible for the validity and the contents of the Certificate. The responsibility for conformity of any object having the same type references as the one tested rests with the manufacturer. Detailed rules on types of certification are given in DNV GL s Certification procedure applicable to KEMA Laboratories. 2 KEMA Report of Performance A KEMA Report of Performance is issued when an object has successfully completed and passed a subset (but not all) of test programmes in accordance with a recognized standard. In addition, the object s technical drawings have been verified and the condition of the object after the tests is assessed and recorded. The report is applicable to the object tested only. A KEMA Report of Performance signifies that the object meets the requirements of the named subclauses of the standard. It can be identified by silver-embossed lettering on the cover and a silver seal on its front sheet. The sentence on the front sheet of a KEMA Report of Performance will state that the tests have been carried out in accordance with The object has complied with the relevant requirements. 3 KEMA Test Report A KEMA Test Report is issued in all other cases. Reasons for issuing a KEMA Test Report could be: Tests were performed according to the client s instructions. Tests were performed only partially according to the standard. No technical drawings were submitted for verification and/or no assessment of the condition of the object after the tests was performed. The object failed one or more of the performed tests. The KEMA Test Report can be identified by the grey-embossed lettering on the cover and grey seal on its front sheet. In case the number of tests, the test procedure and the test parameters are based on a recognized standard and related to the ratings assigned by the manufacturer, the following sentence will appear on the front sheet. The tests have been carried out in accordance with the client's instructions. Test procedure and test parameters were based on... If the object does not pass the tests such behaviour will be mentioned on the front sheet. Verification of the drawings (if submitted) and assessment of the condition after the tests is only done on client's request. When the tests, test procedure and/or test parameters are not in accordance with a recognized standard, the front sheet will state the tests have been carried out in accordance with client s instructions. 4 Official and uncontrolled test documents The official test documents of DNV GL are issued in bound form. Uncontrolled copies may be provided as a digital file for convenience of reproduction by the client. The copyright has to be respected at all times. 5 Accreditation of KEMA Laboratories The KEMA Laboratories of DNV GL are accredited in accordance with ISO/IEC 17025 by the respective national accreditation bodies. KEMA Laboratories Arnhem, the Netherlands, is accredited by RvA under nos. L020, L218, K006 and K009. KEMA Laboratories Chalfont, United States, is accredited by A2LA under no. 0553.01. KEMA Laboratories Prague, the Czech Republic, is accredited by CAI as testing laboratory no. 1035.

-3-2153-16 TABLE OF CONTENTS 1 Identification of the object tested... 10 1.1 1.2 1.3 1.4 Ratings/characteristics of the object tested 10 Description of the object tested 10 Travel recorder 10 List of drawings 11 2 General Information... 12 2.1 2.2 2.3 The tests were witnessed by 12 The tests were carried out by 12 Accuracy of measurement 12 3 Legend... 13 4 Summary of tests... 14 Serial No. 16000702 5 No-load tests... 70 5.1 5.2 5.3 Condition before test 70 Photographs before test 71 Test results and oscillograms 73 6 Determination of pre-arcing time (50 Hz)... 80 6.1 6.2 6.3 Condition before test 80 Test circuit S01 81 Test results and oscillograms 82 7 T100s(a) (50 Hz)... 87 7.1 7.2 7.3 Condition before test 87 Test circuit S02 88 Test results and oscillograms 90 8 T100s(b) (50 Hz)... 92 8.1 8.2 8.3 Condition before test 92 Test circuit S03 93 Test results and oscillograms 95 9 No-load tests... 101 9.1 9.2 9.3 9.4 Condition before test 101 Test results and oscillograms 102 Condition / inspection after test 109 Photographs after test 110

-4-2153-16 Serial No. 16000703 10 No-load tests... 132 10.1 10.2 10.3 Condition before test 132 Photograph before test 133 Test results and oscillograms 134 11 T100a (50 Hz)... 141 11.1 11.2 11.3 Condition before test 141 Test circuit S03 142 Test results and oscillograms 144 12 No-load tests... 152 12.1 12.2 12.3 12.4 Condition before test 152 Test results and oscillograms 153 Condition / inspection after test 160 Photographs after test 161 Serial No. 16000702 13 No-load tests... 184 13.1 13.2 13.3 Condition before test 184 Photograph before test 185 Test results and oscillograms 186 14 L90 (50 Hz)... 193 14.1 14.2 14.3 14.4 Condition before test 193 Test circuit S04 194 Inherent transient voltage record of artificial line 196 Test results and oscillograms 197 15 Voltage tests as a condition check... 203 15.1 15.2 15.3 Condition before test 203 Test circuit S05 204 Test results and oscillograms 205 16 L75 (50 Hz)... 226 16.1 16.2 16.3 16.4 Condition before test 226 Test circuit S06 227 Inherent transient voltage record of artificial line 229 Test results and oscillograms 230

-5-2153-16 17 T60 (50 Hz)... 236 17.1 17.2 17.3 Condition before test 236 Test circuit S07 237 Test results and oscillograms 239 18 No-load tests... 245 18.1 18.2 18.3 18.4 Condition before test 245 Test results and oscillograms 246 Condition / inspection after test 253 Photographs after test 254 Serial No. 16000703 19 No-load tests... 276 19.1 19.2 19.3 Condition before test 276 Photograph before test 277 Test results and oscillograms 278 20 T10 (50 Hz)... 285 20.1 20.2 20.3 Condition before test 285 Test circuit S08 286 Test results and oscillograms 288 21 T30 (50 Hz)... 294 21.1 21.2 21.3 Condition before test 294 Test circuit S09 295 Test results and oscillograms 297 22 Double-earth fault test (50 Hz)... 303 22.1 22.2 22.3 Condition before test 303 Test circuit S10 304 Test results and oscillograms 306 23 No-load tests... 308 23.1 23.2 23.3 23.4 Condition before test 308 Test results and oscillograms 309 Condition / inspection after test 316 Photographs after test 317

-6-2153-16 Serial No. 16000702 24 No-load tests... 340 24.1 24.2 24.3 Condition before test 340 Photographs before test 341 Test results and oscillograms 343 25 L90 (60 Hz) (not successful)... 350 25.1 25.2 25.3 25.4 25.5 Condition before test 350 Test circuit S11 351 Inherent transient voltage record of artificial line 353 Test results and oscillograms 354 Condition / inspection after test 358 26 L90 (60 Hz) (successful)... 359 26.1 26.2 26.3 26.4 Condition before test 359 Test circuit S11 360 Inherent transient voltage record of artificial line 362 Test results and oscillograms 363 27 Voltage tests as a condition check... 370 27.1 27.2 27.3 Condition before test 370 Test circuit S12 371 Test results and oscillograms 372 28 No-load tests... 393 28.1 28.2 28.3 28.4 Condition before test 393 Test results and oscillograms 394 Condition / inspection after test 401 Photographs after test 402 29 No-load tests... 410 29.1 29.2 29.3 Condition before test 410 Photograph before test 411 Test results and oscillograms 412 30 L75 (60 Hz)... 419 30.1 30.2 30.3 30.4 Condition before test 419 Test circuit S17 420 Inherent transient voltage record of artificial line 422 Test results and oscillograms 423

-7-2153-16 31 T60 (60 Hz)... 429 31.1 31.2 31.3 Condition before test 429 Test circuit S18 430 Test results and oscillograms 432 32 No-load tests... 438 32.1 32.2 32.3 32.4 Condition before test 438 Test results and oscillograms 439 Condition / inspection after test 446 Photographs after test 447 Serial No. 16000703 33 No-load tests... 463 33.1 33.2 33.3 Condition before test 463 Photograph before test 464 Test results and oscillograms 465 34 T100a (60 Hz)... 472 34.1 34.2 34.3 Condition before test 472 Test circuit S19 473 Test results and oscillograms 475 35 No-load tests... 480 35.1 35.2 35.3 35.4 Condition before test 480 Test results and oscillograms 481 Condition / inspection after test 488 Photographs after test 489 Serial No. 16000702 36 No-load tests... 511 36.1 36.2 36.3 Condition before test 511 Photograph before test 512 Test results and oscillograms 513 37 Determination of pre-arcing time (60 Hz)... 520 37.1 37.2 37.3 Condition before test 520 Test circuit S20 521 Test results and oscillograms 522 38 T100s(a) (60 Hz)... 528 38.1 38.2 38.3 Condition before test 528 Test circuit S21 529 Test results and oscillograms 531

-8-2153-16 39 T100s(b) (60 Hz)... 533 39.1 39.2 39.3 Condition before test 533 Test circuit S19 534 Test results and oscillograms 536 40 No-load tests... 544 40.1 40.2 40.3 40.4 Condition before test 544 Test results and oscillograms 545 Condition / inspection after test 552 Photographs after test 553 Serial No. 16000703 41 Short-time withstand current and peak withstand current test (50/60 Hz)... 575 41.1 41.2 41.3 41.4 41.5 Condition before test 575 Test circuit S23 576 Photograph before test 577 Test results and oscillograms 578 Condition / inspection after test 580 42 No-load test... 581 42.1 42.2 42.3 42.4 Condition before test 581 Test results and oscillograms 582 Condition / inspection after test 584 Photographs after test 585 Serial No. 16000702 43 No-load tests... 607 43.1 43.2 43.3 Condition before test 607 Photograph before test 608 Test results and oscillograms 609 44 OP2(a) (50 Hz)... 616 44.1 44.2 44.3 Condition before test 616 Test circuit S13 617 Test results and oscillograms 618 45 OP2(b) (50 Hz)... 620 45.1 45.2 45.3 Condition before test 620 Test circuit S24 621 Test results and oscillograms 622

-9-2153-16 46 No-load tests... 627 46.1 46.2 46.3 46.4 Condition before test 627 Test results and oscillograms 628 Condition / inspection after test 635 Photographs after test 636 47 Photographs new parts... 644 48 Explanation for failure during tests... 651 48.1 48.2 Explanation for failure during L90 (60 Hz) 652 Explanation for failure during T100s(b) (60 Hz) 654 49 Drawing... 655

1 IDENTIFICATION OF THE OBJECT TESTED -10-2153-16 1.1 Ratings/characteristics of the object tested Voltage 145 kv Normal current 3150 A Number of poles 3 Frequency 50/60 Hz X Operating sequence O-0,3 s-co-3 min-co X Short-time withstand current 40 ka X Peak withstand current 104 ka X Duration of short-circuit 3 s X Short-circuit making current 104 ka X Short-circuit breaking current 40 ka X DC time constant of rated short-circuit current 45 ms X DC component 53 % X First-pole-to-clear factor 1,5 X Out-of-phase breaking current 10 ka X Line-charging breaking current 50 A Cable-charging breaking current 160 A Pressure for interruption and insulation SF 6 at 20 C 0,75 MPa Supply voltage of closing and opening devices 125 Vd.c. Class E1 X Class C2 Breaker is only intended for use in non-effectively earthed neutral systems. X = This rating has been proved by the tests of this Certificate. 1.2 Description of the object tested A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism Minimum pressure for interruption and insulation at 20 C 0,70 MPa Mechanism: Stored energy closing (springs, charged by motor). Stored energy opening (springs, charged at closing). Supply voltage closing coil Supply voltage opening coil Supply voltage motor 125 Vd.c. 125 Vd.c. 125 Vd.c. 1.3 Travel recorder Travel recorder attached to main contact shaft. Non-linear with contact travel.

-11-2153-16 1.4 List of drawings The manufacturer has guaranteed that the object submitted for tests has been manufactured in accordance with the following drawings and/or documents. KEMA Laboratories has verified that these drawings and/or documents adequately represent the object tested. The manufacturer is responsible for the correctness of these drawings and/or documents and the technical data presented. The following drawings and/or documents have been included in this Certificate: Drawing no./document no. Revision 2TG.029.001 1 The following drawings and/or documents are only listed for reference and are kept in KEMA Laboratories files: Drawing no./document no. Revision Drawing no./document no. Revision 5TG.569.001 1 8TG.750.002 1 5TG.569.002 1 5TG.743.004 1 5TG.551.001 1 5TG.232.004 1 5TG.743.005 1 8TG.200.007 1 5TG.569.003 1 5TG.722.004 1 5TG.550.007 1 2TG.046.006 1 5TG.780.007 1 8TG.282.273 1 5TG.780.008 1 8TG.282.310 1 8TG.040.010 1 8TG.510.024 1 8TG.040.005 1 8TG.510.025 1 8TG.040.009 1 8TG.170.008 1 8TG.423.001 1 8TG.177.016 1 8TG.104.002 1 8TG.232.014 1 8TG.550.004 1 8TG.232.015 1 8TG.550.006 1 8TG.232.016 1 8TG.550.008 1 8TG.450.001 1 8TG.550.009 1 8TG.550.013 1 8TG.599.001 1 8TG.550.106 1 8TG.599.002 1 8TG.569.106 1 8TG.750.001 1

-12-2153-16 2 GENERAL INFORMATION 2.1 The tests were witnessed by Name Luo, X. Yang, L. Dong, G. Xu, S. Company Qingdao TGOOD Electric Co., Ltd., Qingdao, China 2.2 The tests were carried out by Name Dekker, M. (15 June 2016) Hofstee, A.B. (10, 29 June 2016) Minkhorst, D. (2, 20 June 2016) Nijman, R.M. (2, 20 June 2016) Wiggers, R. (30, 31 May, 2, 17, 28 June 2016) Aditya, J. (7, 10 June 2016) Company KEMA Nederland B.V., Arnhem, The Netherlands 2.3 Accuracy of measurement The guaranteed uncertainty for the measured voltages and currents taking into account the total measuring system, is less than 5%, unless mentioned otherwise.

-13-2153-16 3 LEGEND Phase indications If more than one phase is recorded on oscillogram, the phases are indicated by the digits 1, 2 and 3. These phases 1, 2 and 3 correspond to the phase values in the columns of the accompanying table, respectively from left to right. Explanation of the letter symbols and abbreviations on the oscillograms pu Per unit (the reference length of one unit is represented by the black bar on the oscillogram) CS Timing signal contact separation CS1 Timing signal contact separation CS2 Timing signal contact separation CS3 Timing signal contact separation I1cs Current of current circuit, synthetic tests I1TO Current through test object I2cs Current of current circuit, synthetic tests I2TO Current through test object I2TOa Current through test object, amplified I3cs Current of current circuit, synthetic tests I3TO Current through test object I3TOa Current through test object, amplified IABcl Current closing coil auxiliary breaker IABop Current opening coil auxiliary breaker Ics Current of current circuit, synthetic tests Ireig Current reignition circuit, synthetic tests Isyn Current synthetic circuit Isyn1 Current synthetic circuit Isyn2 Current synthetic circuit Itank Tank current test object ITO Current through test object ITO/A Current through test object, amplified ITOcl Current closing coil test object ITOop Current opening coil test object TR Travel recorder U1cs Voltage current circuit U1S Supply voltage U1TO Voltage across test object U2cs Voltage current circuit U2S Supply voltage U2TO Voltage across test object U3cs Voltage current circuit U3TO Voltage across test object Ucs Voltage current circuit UTO Voltage across test object UTO/A Voltage across test object, amplified