PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Similar documents
CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

PHRT 9 / 18 PHRT 12 PHRT 16 PHRT 18. Pompe à chaleur avec équipement hydraulique - Fluide réfrigérant R 410 A

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

KPSW CONSOLE TERMINAL UNIT

High temperature air-to-water heat pumps

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

HT V2 HT Split

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Roof top SPACE RPC 450Z R407C M011

SyScroll 40 to 75 Air NEW

Water chillers water/water type SIGMA Technical information manual

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

TCHE-THHE TCEE

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Galletti Water chillers and heat pumps catalogue

TCHE-THHE TCEE

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

kw COOLING kw HEATING

Roof top SPACE RPC 315Z R407C MA00

Modular Air-cooled Chillers

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Aquaflair TRAC-TRAF-TRAH

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CSAGV 27 / 80. GROUPE FRIGORIFIQUE A CONDENSATION PAR AIR HELICOÏDE Fluide réfrigérant R 407 C

44,9 202,0 kw. technicalcatalogue

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

DYNACIAT POWER. High energy efficiency Compact and quiet

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZA High efficiency air to water heat pumps with HP compressor

Advance Split

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical data LA 60TUR+

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Be sustainable while protecting your business

HIWARM COMPACT kw

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

50A KP 70A KP 90A KP 120A KP 150A KP 210A

environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

30RH B Nominal cooling capacity kw Nominal heating capacity kw

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

kw. technicalcatalogue

HYDRONIC RESIDENTIAL

Compact and silent Scroll compressors All-season operation

M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

Transcription:

TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw * -.0 kw /.00 kw * PHRT.20 kw -.0 kw PHRT.0 kw -.0 kw * single-phase / three-phase December 200 - GB - 02

MARKING This product marked conforms to the essential requirements of the Directives: - Low voltage no. /2 EEC, modified / EEC. - Electromagnetic Compatibility no. / EEC, modified 2/ and / EEC. SUMMARY - Application - Use...................................... 2 2 - Presentation......................................... - Technical characteristics................................ - Physical characteristics................................. - Description.......................................... - Heating performances.................................. - Cooling performances.................................. - Corrections to be made when using anti-freeze.............. - Curves of available pressures............................ - Sound levels........................................ - Accessories......................................... - "ECH" electronic control................................ R A R A is a high-pressure refrigerant (+ 0% in relation to R 22 and R 0 C). The compressors approved for operation with this fluid are filled beforehand with polyalcohol oil. Contrary to mineral oil, it is very hygroscopic: it absorbs the humidity of the ambient air very quickly. This can modify its lubricant properties and lead in time to the destruction of the compressor. MAINTENANCE INSTRUCTIONS - Never add oil to the appliance; the compressor is filled with polyalcohol oil, a special oil which cannot tolerate the presence of other oils. 2 - The instruments used for: - filling, - pressure measurements, - emptying under vacuum, - recovering the fluid, must be compatible and only used for the R A fluid. Note: the pressure taps of the refrigerating circuit are / SAE (/2-20 - UNF) APPLIANCES FILLED WITH R A - In the case of a new charge: - the charge must be undertaken in liquid phase, - use a balance and a dip pipe type R A cylinder, - charge the weight of R A as per the value indicated on the unit s identification plate (for split systems, refer to the installation instructions as the charge must consider the length of the connecting lines). - In case of leakage, do not complete the charge: recover the remaining refrigerant for recycling and perform a total charge. Recovery, recycling or the destruction of the fluid must be done in compliance with the laws in force in the country concerned. - If the refrigerant circuit is opened, you must: - avoid the entry of air into the circuit as much as possible, - replace or install a drier, - perform the vacuum operation at a minimum level of 0. mbar (static). - APPLICATION - USE Chilled water or hot water generator for air conditioning or heating of rooms for terminal unit and boiler overhaul applications. NOTE : The electronic control parameterization is factory-set for terminal unit and boiler overhaul applications. 2

2 - PRESENTATION 2. - DESCRIPTION - Sound-proofed hermetic compressor. 2 - Plate water heat exchanger. - "Plate-Fin" air heat exchanger. - Fan motor. - Fan protection grille. - Electrical box. - Microprocessor control unit display keyboard. - Circulating pump. - Expansion tank. - Safety valve. PHRT - Pressure gauge. - Water inlet connector. - Water outlet connector. - Filling / drainage of the water circuit. - Air vent. - Hole for connecting cables. Materials: - Copper piping. - Painted sheet metal cabinet. - Copper/aluminium air heat exchanger. - Stainless steel water heat exchanger. - Plastic grille. 2 PHRT PHRT PHRT 2 NOTE: The units are supplied with a water filter which is to be installed on the water intake. 2.2 - ELECTRICAL EQUIPMENT "SCROLL" type compressor and its contactor. circulator and its contactor. (or 2) electric fan(s). HP pressure switch and LP pressure switch. Proportional "All-season" control. Water flow rate detection pressure differential cut-out. "ECH" microprocessor control system. Temperature control sensor, located at the water inlet. NOTE: - Electrical equipment according to standard EN 0-2-0.

- TECHNICAL CHARACTERISTICS Model PHRT PHRT PHRT PHRT HEATING Heating capacity kw.00.0 /.0.20.0 Nominal power consumption* kw.. /..2.2 Performance factor (COP)* Water regime 0/ C 2..0 /.22.. Water regime 0/ C.. /.00.0.0 Total Max. -phase kw.00.0 power consumption -phase kw _..00.20 Total Max. -phase A.20 2.0 current consumption -phase A _.00.0.00 Nominal water flow m /h.. / 2. 2.0. - m /s.0.20 /.00.0.0 Available pressure kpa.00.00 /.00.00.00 COOLING Cooling capacity kw..0 /.00.0.0 Nominal power consumption* kw.. /... (EER)* 2.2 2. / 2. 2.2 2.2 Total Max. -phase kw.00.0 power consumption -phase kw _..00.20 Total Max. -phase A.20 2.0 current consumption -phase A _.00.0.00 Nominal water flow m /h.22. /.. 2.0 - m /s.0. /.20.0.0 Available pressure kpa.00 2.00 / 0.00.00.00 (*) Gross value (without circulator) Single-phase / three-phase NOMINAL OPERATING CONDITIONS HEATING Outside air temperature (dry) Outside air temperature (humid) COOLING Outside air temperature (dry) NOTE: Maximum water system pressure: bar. OPERATING LIMITS (pure water) (*) HEATING Max. outside air temperature (dry) Min. outside air temperature (dry) for water output temperature C (max.) Min. outside air temperature (dry) for water output temperature 0 C Min. outside air temperature (dry) for water output temperature C (nominal) Max. water output temperature for a min. outdoor air temperature (dry) (- C) Min. water outlet temperature COOLING Max. outside air temperature (dry) Min. outside air temperature (dry) Max. water outlet temperature Min. water outlet temperature + C + C + + + C PHRT PHRT PHRT PHRT + 20 C + 20 C + 20 C + 20 C + C + C + C Max. water 0 C - C - C - C + C - C - C - C 0 C + C + C + C + C + + + + + C (**) + C (**) + C (**) + C (**) + C + C + C + C + 20 C (**) + 20 C (**) + 20 C (**) + (**) + C + C + C + C (*) The limits indicated are those of the machine. (**) At C outside air temperature, the max. temperature of the water outlet is limited to C.

- PHYSICAL CHARACTERISTICS Model PHRT PHRT PHRT PHRT Dimensions L mm,0,0,0,0 H mm,2,2,2 P mm 0 0 0 0 Weight kg Dimensions L mm,20,20,20,20 packaged H mm 20,20,20,20 P mm 20 20 20 20 Weight kg 0 H Fastening L P H L P Water inlet connection (male) with air vent valve 2 Water outlet connection (male) Water circuit fill/drain Holes for electric cables PHRT PHRT PHRT PHRT 0 0 0 0 2 Rear view 2 Rear view

- DESCRIPTION Model Hermetic compressor with thermal protection Sound insulation cover PHRT PHRT PHRT PHRT Power supply 20V//0Hz 00V/N/0Hz _ Start-up current -phase A -phase A _ Start-up current with kit single-phase start-up (accessory) Direct drive propeller fan motor with thermal protection, horizontal blowing Total air flow m /h,000,000,000,00 m /s 0... 2. Propellor diameter mm 0 0 0 0 Power supply 20V//0Hz Rotation speed rpm 0 0 0,00 Current A 0... 2. Power input kw 0.0 0.20 0.20 0.20 Expansion system (*) expansion valve Water capacity liters 0..0.. Expansion system (*) expansion valve Air exchanger with louver fins and water-repellant treatment Water exchanger Plate-type stainless steel water treatment section Charged internal cooling system with HP and LP switch kg 2.. /... Current A 0... Power input kw 0. 0.2 0.2 0.2 Power supply 20V//0Hz R A refrigerant Total charge -phase / -phase Circulating pump Capacity liters 2 2 2 2 Expansion tank (charge pressure. bar) Safety valve (pressure bar) Pressure gauge (0 to bar) Air vent valve Hydraulic system Male connections inlet /" " " " outlet /" " " " Water capacity of the unit liters 2. 2..2. Water flow rate detection pressure differential cut-out Water filter supplied, uninstalled Water volume in system Minimum water volume (**) liters 0 0 0 0 Maximum water volume (***) Terminal unit or overhaul application liters 0 0 0 0 Mains power supply Power supply 20V//0Hz 00V/N/0Hz _ IP 2 IP 2 IP 2 IP 2 Equipment protection index A Scroll Scroll Scroll 2 Scroll 2 2 2 (*) The PHRT, and units are equipped with a single bi-flow regulator used for both heating and cooling operation. The PHRT is equipped with two regulators (one for heating and one for cooling) (**) If the water volume of the system is below the minimum, a buffer tank must be installed. (***) If the water volume of the system is above the maximum, an additional expansion tank is required.

- HEATING PERFORMANCES PHRT PHRT mono (single-phase) PHRT tri (three-phase) Heating capacity (kw) Heating capacity (kw) Heating capacity (kw) HEATING CAPACITY 0 C C - - - - -2 0 2 20 0 C C - - - - -2 0 2 20 C 0 C - - - - -2 0 2 20 INPUT POWER C. 0 C 2. - - - - -2 0 2 20.2...2 C 0 C - - - - -2 0 2 20 C. 0 C. - - - - -2 0 2 20 PHRT Heating capacity (kw) 0 C C... C 0 C - - - - -2 0 2 20. - - - - -2 0 2 20 PHRT Heating capacity (kw) 2 2 2 22 2 20 - - - - -2 0 2 20... - - - - -2 0 2 20

- COOLING PERFORMANCES COOLING CAPACITY INPUT POWER PHRT Cooling capacity (kw) C.. 2. C PHRT mono (single-phase) PHRT tri (three-phase) Cooling capacity (kw) Cooling capacity (kw) 2 20 20 ( C) ( C).. 2. 20 2 20 ( C) ( C).. 20 20 ( C) ( C) PHRT Cooling capacity (kw) C 20 ( C). C.. 20 ( C) PHRT Cooling capacity (kw) 0 2 2 2 22 20... 20 22. 2 ( C).... C. C... 20 22. 2 ( C)

- CORRECTIONS TO BE MADE WHEN USING ANTI-FREEZE (Cooling mode) IMPORTANT: Use monopropylene glycol. A minium rate of % to 20% is needed to avoid any risk of corrosion. Correction factors.0.20. Pressure drop. - PRINCIPLE OF USING THE CURVES Choose the percentage of glycol according to the minimum temperature to protect the hydraulic circuit against frost and determine the coefficients to be applied to the power, the water flow rate and the pressure drop... Water flow.2 - EXAMPLE Protection at an external temperature of - C, which gives 0% glycol ("Freezing points" curve). The "Reduction of cooling capacity" curve gives the coefficient to be applied to the refrigerating capacity (0.). The "Water flow" curve gives the coefficient to be applied to the water flow rate (.). The "Pressure drop" curve gives the coefficient to be applied to the pressure drop (.). Curves valid for temperature control on the water intake. Outdoor temperature C Reduction of cooling capacity.00 0. -2-20 Freezing points - - - 0 0 20 0 0 % in weight of Monopropylene Glycol - CURVES OF AVAILABLE PRESSURES (on unit's outlet) PHRT PHRT Available pressure (kpa) 0 0 0 0 0 0 Speed Available pressure (kpa) 0 0 0 0 0 0 0 0 0 0 0 Speed 20 Speed Speed 2 0 20 Speed Speed 2 0 0 0.. 2 0 0 0.. 2 2. Water flow rate (m /h) Water flow rate (m /h)

PHRT PHRT Available pressure (kpa) 0 0 0 0 Available pressure (kpa) 0 0 0 0 0 0 0 0 0 0 Speed 2 0 0 Speed 0 0 0 20 0 Speed 0 0.. 2 2. Water flow rate (m /h) 0 20 0 Speed Speed 2 0 0.. 2 2... Water flow rate (m /h) - SOUND LEVELS Model Power level Sound-pressure level Lw (dba) Lp (dba) PHRT PHRT PHRT PHRT Sound-pressure level: Unit installed outdoors (free field) on a reflective surface. Measurement carried out at a distance of m. db to be deducted from the sound power level 0 0 2 20 2 0 Distance in meters - ACCESSORIES PHRT PHRT PHRT PHRT Set of 2 flexible hoses length m Ø /" _ Condensate tank heating cord kit Single start-up kit (for single-phase model) Remote control RS communication interface length m Ø " _ (MODBUS protocol) Insulated tank 0 liters

- "ECH" ELECTRONIC CONTROL Microprocessor control module, including: - chilled water temperature control (water return), - control of operating parameters, - self-adapting algorithm for water volume reduction, - circulating pump control (frost protection and anti-sticking function), - anti-short cycle system, - hour counter compressor and circulating pump, - alarm management, - anti-freeze security (water exchanger), - digital display of:. water temperature,. set-point,. alarm code (HP, LP, water output, probes, anti-freeze...). - remote alarm reporting is possible via a potential-free contact, - integrated condensation pressure control, - heating cord control (accessory), - remote control with display unit (accessory), - serial communications port (RS interface, accessory) - MODBUS Protocol.

Due to our policy of continuous development, our products are liable to modification without notice. R.D. 2 Reyrieux BP 00 Trévoux CEDEX France Phone 00 2 2 - Fax 00 2 00 R.C.S. Bourg-en-Bresse B 200 2