Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors

Similar documents
Respiratory Function Solutions Sensor and Sampling Line Guide. Nellcor with OxiMax Technology Product Guide A Full Line of Oximetry Sensors

Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

HUG.ai 1/24/06 9:33:34 AM HUG.ai 1/24/06 9:33:34 AM C M Y CM MY CY CMY K

N-600. Pulse Oximeter Home Use Guide

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Vitalmax 4000 CL Product Specifications

OMNI Express VS VERSATILITY IN VITAL SIGNS

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

CLEO VERSATILITY IN VITAL SIGNS

Operator s Manual. LifeSense LS1-9R. Vital Signs Monitor. Capnography/Pulse Oximeter

SureSigns VS4. Vital Signs Monitor Technical Data Sheet

N-595. Pulse Oximeter Service Manual

Nellcor Puritan Bennett Inc. is an affiliate of Tyco Healthcare. Nellcor, Oxiband, Durasensor, OxiCliq, Dura-Y, MAX-FAST, and OXIMAX are trademarks

N-600. Pulse Oximeter Operator s Manual

Model 900. Pulse Oximeter User s Manual

About this Manual. Statement. P/N: Release Date: August 2010 Copyright EDAN INSTRUMENTS, INC All rights reserved.

OMNI TOUCH SCREEN PATIENT MONITOR

1 Appendix - Product Specifications

Operator s Manual. Avant Digital Pulse Oximeter. English

740 SELECT. Multi-Parameter Monitor

SPECIFICATION FOR MULTIPARAMETER MONITOR

Operator s Manual. Avant Digital Pulse Oximeter. English

Infinity M300 Patient Worn Monitoring

qube mini Overview

Operator s Manual. Avant Digital Pulse Oximeter. English

5/ 5i/ 5c/ 7/ 7i/ 7c/ 5 elite/ 5i elite/ 5c elite/ 7 elite/ 7i elite/ 7c elite

OPERATOR S MANUAL. NELLCOR N-200 Pulse Oximeter

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd.

signal extraction pulse oximeter OPERATOR S MANUAL

Patient Monitoring System YM5500. Service Manual

Omni (K) PATIENT MONITOR

Product Specifications

SERVICE MANUAL. NPB-295 Pulse Oximeter

LifeSense Vet LS1-10R

DPM Summary of Features and Benefits

OKM 801INFANT INCUBATOR

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

Atlas Monitor Outline Train the Trainer

MRI Patient Monitoring System (Model )

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

with color display signal extraction pulse co-oximeter with Rainbow Technology OPERATOR S MANUAL

Operator s Manual. Models 8600FO and 8600FOM Pulse Oximeters. English

ARGUS VCM Vital Compact Monitor

Infinity M300+ Telemetry

Operator s Manual. Avant Avant 4000 Digital Pulse Oximetry System with Bluetooth Wireless Technology. English

SECTION L MONITORING EQUIPMENT

SOFTWARE VERSION 8.5 FAQs

Model 7500 Model 7500

TruSat Pulse Oximeter

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

PATIENT MONITORING SYSTEMS

Operating manual Reusable Pulse Oximetry Sensors

VitalCare 506N3 Series Patient Monitor Operator s Manual

Measurements to guide your patient care

Guide, Quick Start, Short, X-100 System

IQvitals Zone TM. For Models: User Guide

PULSE OXIMETER PACKAGE

SECTION L MONITORING EQUIPMENT

HANDHELD PULSE OXIMETER

MRI Monitor. All-in-one monitor for the MRI environment. Features. Parameters. Accessories

Liquid Helium Level Instruments

SERVICE MANUAL. Patient Monitor M30. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

PATIENT MONITORING SYSTEMS

Puritan Bennett 980 Ventilator System Planning for Training Checklist

Nardalert S3 TM Non-Ionizing Radiation Monitor

PATIENT MONITORING SYSTEMS

CASMED 740 Vital Signs Monitor

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

LC1350 Level Controller

Important user information

PM-9000 Express Portable Patient Monitor

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

Oxylog VE300 Emergency & Transport Ventilation

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

Operator s Manual. Model 7500FO. Model 7500FO. Digital Pulse Oximeter. English

DINAMAP ProCare Monitor. Operation Manual

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

About this Manual. Statement. Release Date: January, 2014

BC3250. Blowdown Controller

Multi-Parameter Patient Monitor

OxiMax N-600x Pulse Oximeter with Alarm Management System

Operator s Manual. 2500A PalmSAT. Pulse Oximeter with Alarms. English

901-M / 901-ML. Pulse Oximetry System. Technical Information and Service Manual

Oxylog VE300 Emergency & Transport Ventilation

Operator s Manual. Avant Pulse Oximeter and Noninvasive Blood Pressure (NIBP) Monitor English

Model 5340V Pulse Oximeter for Veterinary Use

MODEL 3X Series User s Manual

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

CARDELL Veterinary Vital Signs Monitor

HBP Patient Monitor. Operator s Manual. EU representative OBELIS S.A Bd. Général Wahis, Brussels, Belgium.

Operator s Manual. Model X-100. Universal Oximetry System English

Userʼs Manual MEDIAID INC.

Operating Instructions. Passport _PPV ops color.indd 1

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

Ultraview SL2400 With Wireless-LAN-Option

WARNINGS AND CAUTIONS WARNING. Federal law restricts this device to sale by or on the order of a physician or other licensed practitioner.

ConchaTherm Neptune Heated Humidifier User s Manual /07 English (EN)

User Guide. Cardell Insight Veterinary Monitor. For Models: 8014 Blood Pressure Blood Pressure, Pulse Oximetry

Installation guide for J4 Junction Box for R4 AIS Transponder System

Operator s Manual. Avant Pulse Oximeter and NIBP Monitor. English

Transcription:

Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors Specialty sensors Forehead Sensor For patients with low perfusion; suitable for long-term monitoring Forehead Sensor and Headband Adult/Pediatric >10 kg CATALOG NO. MAXFAST CASE/24 Sensors with low saturation expanded accuracy range. Specialty sensors Adult/Neonatal Sensor, Nonadhesive For patients with fragile skin; suitable for long-term monitoring Adult Neonatal Preemie Adult >40 kg Neonatal 1.5-5 kg Preterm Infant <1.5 kg CATALOG NO. SC-A SCNEO-1 SC-PR CASE/24

Single-Patient-Use Sensors Adhesive Sensors Comfortable, form-fitting sensors; suitable for long-term monitoring Adult Neonatal/Adult Infant Pediatric Adult Adult >30 kg Neonatal/Adult <3 kg or >40 kg Infant 3-20 kg Pediatric 10-50 kg Adult Nasal >50 kg CATALOG NO. MAXA/MAXAL* MAXN MAXI MAXP MAXR CASE/24 *36 cable Sensors with low saturation expanded accuracy range. Two-Piece Sensors Sensors Single-patient-use adhesive bandage, reusable cable Adult Neonatal/Adult Infant Pediatric Sensor Cable Adult >30 kg Neonatal/Adult <3 kg or >40 kg Infant 3-20 kg Pediatric 10-50 kg Sensor Cable 3 CATALOG NO. A N I P OC-3 CASE/24 SENSORS, 1/PKG CABLE Reusable Sensors Reusable Sensors Single-patient-use adhesive bandage, reusable cable Adult Neonatal/Adult with Wraps Pediatric/Infant with Wraps Adult >30 kg Adult/Neonatal <3 kg or >40 kg Pediatric/Infant 3-40 kg CATALOG NO. DS100A-1 OXI-A/N OXI-P/I CASE/24 SENSORS, 1/PKG CABLE 2 NELLCOR WITH OxiMax TECHNOLOGY Product Ordering Guide

Reusable Sensors Reusable Multisite Sensors Multisite Ear Clip Pediatric Clip Replacement Sleeves Use with wraps or clip accessories Multisite >1 kg Use with sensor >30 kg Use with sensor 3-40 kg CATALOG NO. D-YS D-YSE D-YSPD PDSLV 1/PKG SENSORS/CLIPS, 1 PAIR/SLEEVES Reusable Sensors Reusable Sensor Wraps Wrap Adhesive Wraps Foam Wraps For sensors with wraps and multisite, reusable sensors For OXI-P/I, OXI-A/N, D-YS For OXI-A/N, D-YS For OXI-P/I, D-YS For OXI-A/N, D-YS For OXI-P/I, D-YS CATALOG NO. Posey ADH-A/N ADH-P/I FOAM A/N FOAM P/I CASE/24 POSEY, 100/PKG OTHERS Sensor extension cables Sensor Extension Cables For Nellcor pulse oximeters with and without OxiMax technology For pulse oximeters without OxiMax technology For Nellcor pulse oximeters with OxiMax technology only For compatibility with specific sensor/monitor models, contact your local Covidien representative or call 800-NELLCOR. 4 or 8 Sensor Extension Cable 10 Patient Interface Cable CATALOG NO. DEC-4/DEC-8 MC-10 DOC-10 1/PKG For more information call 800-NELLCOR or visit www.covidien.com. NELLCOR WITH OxiMax TECHNOLOGY Product Ordering Guide 3

Nellcor N-600x Pulse Oximeter with OxiMax TECHNOLOGY Alarm Management System Features and Specifications Performance Measurement Range : 1% to 100% Pulse rate: 20 to 250 beats per minute (bpm) Perfusion range: 0.03% to 20% Accuracy 1 Saturation (% ± 1 SD) 70% to 100% ± 2 digits 60% to 80% ± 3 digits Low perfusion: 70% to 100% ± 2 digits Pulse rate: 20 to 250 bpm ± 3 digits Low perfusion: 20 to 250 bpm ± 3 digits Electrical Instrument Power requirements: 100 to 120 VAC, 200 to 240 VAC, 50/60 Hz, 20 VA Fuse rating: 0.5 Amperes Battery Type: Sealed lead-acid internal battery Battery capacity: Typically 7 hours using new, fully charged battery Charge time: 8-12 hours Environmental Operating Temperature Instrument: 5 C to 40 C Transport/storage temperature (in shipping carton): -20 C to 70 C Operating humidity: 15% to 95% noncondensing Operating altitude: -1,280 ft to 12,000 ft Physical Characteristics Weight: 5.7 lb (2.6 kg) Size: 3.3 in H x 10.4 in W x 6.8 in D (8.4 cm x 26.4 cm x 17.3 cm) Equipment Classification IEC 60601-1 ISO 9919 CSA 601.1 EN/IEC 60601-1-2 (2nd ed.) UL 2601-1 IPX1 EN865 Emissions Compliance EN55011, Group 1, Class B Output EIA-232 and RS-422 digital output from serial port OxiNet Communications Output Protocol Nurse call capability Analog output (0-1V);, pulse rate and plethysmographic waveform Displays/Indicators High-quality LCD graphical screen Visual indicators: Pulse search, audible alarms silenced or off, interference indicator, low battery and battery charging, battery fuel gauge, sensor off, sensor disconnect, data in sensor and SatSeconds alarm management clock Alarms Audible and visual alarms for high/low saturation and pulse rate SatSeconds alarm management settings: 10, 25, 50, 100 or OFF Audible and visual warning indicators for low battery Audible sensor disconnect alarm and sensor off alarm Displayed saturation and pulse rate alarm limits Backup speaker with escalating alarm tones Optional Accessories GCX mounting options Interface cables Carrying cases CATALOG NO. N600x Refer to the Nellcor N-600x pulse oximeter operator s manual for complete descriptions, instructions, warnings, cautions and specifications. Specifications are subject to change without notice. 4 NELLCOR WITH OxiMax TECHNOLOGY Product Ordering Guide

Nellcor OxiMax N-560 Pulse Oximeter with OxiMax TECHNOLOGY Features and Specifications Performance Measurement Range : 1% to 100% Pulse rate: 20 to 250 beats per minute (bpm) Perfusion range: 0.03% to 20% Accuracy 1 Saturation (% ± 1 SD) 70% to 100% ± 2 digits 60% to 80% ± 3 digits Low perfusion: 70% to 100% ± 2 digits Pulse rate: 20 to 250 bpm ± 3 digits Low perfusion: 20 to 250 bpm ± 3 digits Electrical Instrument Power requirements: 100 to 240 VAC, 25 to 39 VA Fuse rating: Qty 2, 2A, 250 volts, slow-blow IEC (5x20 mm) BATTERY Type: NiMH Battery capacity: Minimum of 8 hours using new, fully charged battery with no alarms, no serial data Environmental OPERATING TEMPERATURE Instrument: 10 C to 45 C Transport/storage temperature (in shipping carton): -20 C to 70 C Operating humidity: 15% to 95% noncondensing Operating altitude: -1,280 ft to 18,288 ft Physical Characteristics Weight: 3.07 lb (1.39 kg) Size: 2.95 H x 9.06 W x 5.04 D (inches) (7.5 cm x 23.0 cm x 12.8 cm) EQUIPMENT classification IEC 60601-1 IS0 9919:2005 CSA 601.1 EN/IEC 60601-1-2 (2nd ed.) UL 2601-1 IPX1 EMISSIONS COMPLIANCE EN55011, Group 1, Class B OUTPUT EIA-232 digital output from serial port OxiNet Communications Output Protocol Nurse call capability Displays/INDICATORS High-quality LED display changes from green to red during alarm conditions Pulse amplitude indicator (10-segment LED) Visual indicators: Pulse search, audible alarms silenced or off, interference indicator, battery charging, data in sensor and SatSeconds alarm management clock ALARMS Audible and visual alarms for high/low saturation and pulse rate SatSeconds Alarm Management settings: 10, 25, 50, 100 or OFF Audible and visual warning indicators for low battery and sensor off Audible sensor disconnect alarm OPTIONAL ACCESSORIES GCX mounting adapter Pole mount clamp Interface cables Visual alarm indicator antenna CATALOG NO. N560 Refer to the Nellcor N-560 pulse oximeter operator s manual for complete descriptions, instructions, warnings, cautions and specifications. Specifications are subject to change without notice. NELLCOR WITH OxiMax TECHNOLOGY Product Ordering Guide 5

Nellcor N-65 Hand-held Pulse Oximeter with OxiMax TECHNOLOGY Features and Specifications Performance Display Range : 0% to 100% Pulse rate: 20 to 250 beats per minute (bpm) Accuracy 1 Saturation (% ± 1 SD) 70% to 100% ± 2 digits 60% to 80% ± 3 digits Low perfusion: 70% to 100% ± 2 digits Pulse rate: 20 to 250 bpm ± 3 digits Low perfusion: 20 to 250 bpm ± 3 digits Power Requirements 6 V supplied by four AA-size batteries Battery Life Alkaline: 19 hours (typical) Lithium: 40 hours (typical) Environmental Storage/shipping temperature: -4 F to 158 F (-20 C to 70 C) Operating temperature: 41 F to 104 F (5 C to 40 C # del) Operating altitude: -1,254 ft to 9,882 ft (-382 m to 3,012 m) Relative humidity: 15% to 95% noncondensing Physical characteristics Weight (with batteries): 0.65 lb (0.29 kg) Size: 2.8 x 6.2 x 1.4 (inches) (7.3 cm x 15.8 cm x 3.5 cm) Standards EN60601-1-2: 2001 (CISPR 11, Class B) EN60601-1: 1990 (A1+A2) UL 60601-1, CAN/CSA C22.2 No. 601.1 (Class: Internally Powered, Type BF) EN60601-1-8 EN865 Displays Oxygen saturation, pulse rate, vertical bar graph Indicators Pulse amplitude, pulse search, low battery, alarm silence, interference, data in sensor, sensor disconnect, print Optional Accessories Protective boot (3 color options) Moisture-resistant jacket Carrying case Citizen portable infrared printer CATALOG NO. N65 Refer to the Nellcor N-65 pulse oximeter operator s manual for complete descriptions, instructions, warnings, cautions and specifications. Specifications are subject to change without notice. 6 NELLCOR WITH OxiMax TECHNOLOGY Product Ordering Guide

Nellcor N-85 Hand-held Capnograph/Pulse Oximeter with OxiMax technology Features and Specifications Performance Capnograph Display range: 0 to 99 mm Hg (0-13.2 kpa and 0-13.0 vol% at sea level) Sampling rate: 50 ± 7.5 ml/min Warm-up time: 30 seconds typical, reaches steady-state accuracy 20 minutes after power up Accuracy: 0 to 38 mm Hg ±2 mm Hg 39 to 99 mm Hg ±5% of reading Respiration rate: 0 to 150 breaths/minute Pulse Oximeter Display range: : 0% to 100% Pulse rate: 20 to 250 beats/minute Accuracy 1 Saturation (% ± 1 SD) 70% to 100% ± 2 digits 60% to 80% ± 3 digits Low perfusion: 70% to 100% ± 2 digits Pulse rate: 20 to 250 bpm ± 3 digits Low perfusion: 20 to 250 bpm ± 3 digits Communication Interface RS-232 interface @ 9600 baud; full duplex serial interface via RJ-45 connector Electrical Instrument Power requirements: AC input of 100 to 230 VAC @ 60/50 Hz Battery Type: Rechargeable NiMH Battery capacity: Supplies power for 4 to 7 hours (depending on power management) Fully recharges in approximately 4.5 hours Environmental Operating temperature: 32 F to 113 F (0 C to 45 C) Storage temperature: -31 F to 158 F (-35 C to 70 C) Operating and storage: Pressure: 430 mm Hg to 795 mm Hg Altitude: -1,250 ft to 15,000 ft (-381 m to 4,572 m) Humidity: 10% to 95% noncondensing Shock test IEC 68-2-27 Sinusoidal vibration test IEC 68-2-6 Random vibration wide band test IEC 68-2-34 Drop test MIL-STD-810E, method 516.4-II Standards IEC 60601-1/EN 60601-1 EN60601-1-2 second edition EN 864 EN 865 UL 2601-1 EN 475 EN 55011-Class B-Group 1 CSA C22.2 No.601.1-M90 Physical Characteristics Weight: 1.87 lb (850 g) Size: 8.11 in H x 3.46 in W x 2.06 in D (206 mm x 88 mm x 53 mm) Displayed Parameters CO 2 and plethysmographic waveforms, etco 2,, pulse rate, respiration rate, trend data Display Graphic LCD display (128 x 64 dots) with LED backlight (contrast and backlight control); two numeric fields, three digits each, using 7-segment LED; two-color LED alarm bar Alarms Adjustable alarm limits for all parameters; audio level as defined in ISO 9703-2 standard CO 2 Accessories Nonintubated applications: Smart CapnoLine * and Smart CapnoLine * O 2 oral/nasal circuits CapnoLine * H and CapnoLine * H O 2 nasal circuits NIV Line nasal circuit Intubated applications: FilterLine * Set and FilterLine * H Set, combination etco 2 circuit and airway adapter H indicates for humidified applications; up to 72-hour duration Other Accessories Carrying case Protective boot Pole mount clamp Digital to analog converter Communication adapter kits Calibration gas kit External battery charger Extra rechargeable battery pack Battery pack carrying pouch Nurse call and remote monitoring interface kits CATALOG NO. N85 Refer to the Nellcor N-85 pulse oximeter operator s manual for complete descriptions, instructions, warnings, cautions and specifications. Specifications are subject to change without notice. NELLCOR WITH OxiMax TECHNOLOGY Product Ordering Guide 7

Nellcor OxiMax Nell-1 OEM Pulse Oximetry Module Nellcor OxiNet III remote respiratory monitoring system For your OEM or Nellcor technology solutions, please contact your local Covidien sales representative at 800-NELLCOR. 1. Adult and neonate specifications are shown for the Nellcor MAX-A and MAX-N sensors with OxiMax technology. Saturation accuracy will vary by sensor type. Refer to Nellcor Sensor Accuracy Grid Card for details. COVIDIEN, COVIDIEN with logo, Covidien logo and positive results for life are U.S. and internationally registered trademarks of Covidien AG. Other brands are trademarks of a Covidien company. * are trademarks of their respective owners. 2011 Covidien. All rights reserved. 11-PM-0449 SN09709 6135 Gunbarrel Avenue Boulder, CO 80301 800-635-5267 www.covidien.com 8 NELLCOR WITH OxiMax TECHNOLOGY Product Ordering Guide