Global Standard Quality : Healthcare is our Business OXIPRO is a Disposable PulseOximeter sensor which have various advanced biocompatibility and function, provides early information on problems in the delivery of oxygen to the tissue. Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,
Features & Benefits Designed for optimal comfort and accuracy. Compatible with major leading manufactures of pulse oximetersystem. Bright, highquality LEDs to maximize signal tracking capabilities. Four different bandage styles permit monitoring of all patient populations. Provide a costeffective. Gold plated connector pin. Applied evaporation elastic cotton tape. Onepiece bandage construction with visible alignment marks for easeof use and patient comfort. Builtin shielding for both the photodiode and the cable to protect the signal during transmission. Specification Accuracy LED Wave length 100% SaO2 (±2 digits) 100% SaO2 (±3 digits) 0 % SaO2 (unspecified) Red LED IR LED Lead Wire adult, infant, pediatric neonate 660 nm nominal 0 nm nominal Connector A custom 9 pin DSub connector, Male, Length 0.95M Photodiode Active Area OXIPRO DA OXIPRO DN 3 3 mm2 120 16 mm 120 14 mm Mediplast tape Dimensions OXIPRO DP OXIPRO DI OXIPRO DAC OXIPRO DPC 86 66 mm 65 66 mm 86 66 mm 65 66 mm Maximum Power dissipation of LED Radiant intensity(po) 120mW 0.2mW(Red) / 0.3mW(IR) (IF=20mA) Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,
OXIPRO OXIPRO D Series OXIPRO DA OXIPRO DN OXIPRO DAC, DPC OXIPRO DI OXIPRO DP OXIPRO R Series OXIPRO RA OXIPRO RP Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,
OXIPRO Elite Sensor Specification PARAMETER Distrib. Symbol Min Old Typ Max Min New(Elite) Typ Max Unit Peak Emission Wavelength IR LED RED LED λp 657 8 672 0 658 5 660 910 662 Nm Spectral Bandwidth IR LED RED LED Δλ 30 30 30 10 Nm It is extremely important that the RED LEDs used in pulse oximeter probes emit a very narrow range of wavelengths centered at the desired 660nm in order to minimize error in the SpO2 reading, which is the pulse oximeter s estimation of arterial oxygen saturation. Typical LEDs have a spectral bandwidth in the range of 60nm to less than 20nm, with visible LEDs usually having smaller bandwidths of approximately 25nm and IR LEDs typically having larger bandwidths near 50nm, but a better than accuracy for neonate, we will change new Red LEDs that having bandwidths of approximately 10nm.(Previous RED LED having bandwidths of approximately 30nm) Test Result to neonate Old New(Elite) Nellcor Response time 8~10 sec after appear R curve 4~5 sec after appear R curve 4~5 sec after appear R curve Wave peak Intermittent or flat peak (no signal) Error at Low Perfusion Always 15~20% high SpO2 value to low SaO2 value Bandage Adhesions 0.3 kgf (Peel strength from skin) 0.45 kgf (Peel strength from skin) 0.2 kgf (Peel strength from skin) Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,
OXIPRO Elite Comparison SpO2 Value Simulator Value OXIPRO(General) OXIPRO(Elite) Nellcor 98% 75BPM 98 98 % 75BPM Normal % 75BPM 84% 75BPM 91 84 84 83 80% 75BPM 80 80 79 % 75BPM 68 Neonate/Shiver % 180BPM 91 95 Neonate % 180BMP 91 Hypoxic/Shiver % 95BPM 71 Hypoxic/Tap % 95BPM Hypoxic % 95BPM 71 Brad/Shiver % 45BPM Brad % 45BPM Weak/Shiver % 95BPM 93 92 Weak/Tap % 95BPM 93 92 Weak % 95BPM 92 91 Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,
COMPATIBLE MONITOR LIST Manufacture Monitor model Extension cable Philips (HP) 78352C, 78354C, 734C, M1020A, M1205A, M1205B, M1350B, M1722A/B, M1732A/B, Viridia A1, Viridia A3 M2601A, M3000A, M3500B, M4735A, M2475B, M4529A, MP20, MP30, MP40, MP60, MP, MP80, MP, M3,M4 N10, N20, N20PA, N100, N180, N1, N200, NBP40/45, NBP75, NBP1/195, NBP30, NBP4000, Monitor with Nellcor module Nellcor NBP2/295, NBP3/395, N3000, N6000,N65 N550, N595, All Nellcor OXIMAX SC6000, SC6002XL, SC00, SC8000, SC00XL Siemens & Drager Vitalert 1000, Cicero, Narkomed, Vitara, PM8014, PM8060 Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,
COMPATIBLE MONITOR LIST Manufacture Monitor model Extension cable Dinamap /9710/9720, Plus, Compact TS, MPS, Dinamap Pro 300/400 GE Medical (Marquette, Critikon, Corometrics, Datex) Eagle, Dash, Solar, Tram modular x50sl series (250SL,450SL,650SL,850SL,850A,451N) (Do not work Dash 5000, Solar 00, PDM modular series) Corometrics 1, 128, 128F, 129, 129F AS/3, CS/3, CH/S, CH/2S, CHRS, CG/2S, CardiocapI, CardiocapII, Cardiocap 5, Capnomac Ultima, Light Monitor, MEstpr, OscarII, SatliteTrans, Satlite Trans puls, ULTSVI, ULTSVO, ULTSIO, ULTS00, OSP200 NONIN 8500, 8600, 80, 00 SpaceLabs PC scout, 3506, 465, 466, 467, 468, 489, 651A08, 43XMTR, 351, 411, 617, 496 Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,