Global Standard Quality : Healthcare is our Business

Similar documents
Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

Technical Data Sheet 5mm Infrared LED, T-1

Technical Data Sheet 1.5mm Side Face Infrared LED

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

Operating manual Reusable Pulse Oximetry Sensors

SureSigns VS4. Vital Signs Monitor Technical Data Sheet

SPECIFICATION FOR MULTIPARAMETER MONITOR

Cardiology Products H6317

Exercise 1: IR Transmission and Reception

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

Oxitest Plus7 Pulse Oximeter Tester

Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors

Technical Data Sheet. Pb Free. Specification NB104 SSC. Customer. Rev. 03 July 서식번호 : SSC- QP (Rev.0.

Respiratory Function Solutions Sensor and Sampling Line Guide. Nellcor with OxiMax Technology Product Guide A Full Line of Oximetry Sensors

About this Manual. Statement. P/N: Release Date: August 2010 Copyright EDAN INSTRUMENTS, INC All rights reserved.

N-600. Pulse Oximeter Operator s Manual

HUG.ai 1/24/06 9:33:34 AM HUG.ai 1/24/06 9:33:34 AM C M Y CM MY CY CMY K

EVERLIGHT ELECTRONICS CO.,LTD.

Technical Data Sheet 1.6mm Side Looking Phototransistor

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Professional Design Project

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

N-595. Pulse Oximeter Service Manual

EMITTER TECHNICAL DATA

Product Specifications

5/ 5i/ 5c/ 7/ 7i/ 7c/ 5 elite/ 5i elite/ 5c elite/ 7 elite/ 7i elite/ 7c elite

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

MRI Patient Monitoring System (Model )

818 Series Low-Power Detectors

TruSat Pulse Oximeter

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Operator s Manual. Models 8600FO and 8600FOM Pulse Oximeters. English

Optical Sensors. ROHM Semiconductor USA, LLC 1

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

GE Healthcare. Dash Variable-Acuity Monitoring

MODEL 3X Series User s Manual

SMT450. High Performance TOP LED

Nellcor Puritan Bennett Inc. is an affiliate of Tyco Healthcare. Nellcor, Oxiband, Durasensor, OxiCliq, Dura-Y, MAX-FAST, and OXIMAX are trademarks

N-600. Pulse Oximeter Home Use Guide

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

Technical Data Sheet 5mm Phototransistor T-1

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

WARNINGS AND CAUTIONS WARNING. Federal law restricts this device to sale by or on the order of a physician or other licensed practitioner.

Patient Monitoring System YM5500. Service Manual

PM-9000 Express Portable Patient Monitor

Infinity M300+ Telemetry

SERVICE MANUAL YM6000 Patient Monitor

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

Userʼs Manual MEDIAID INC.

TORONTEK-B400 Pulse Oximeter. User Instructions

Specification MBT801-S

Operator s Manual. Avant Digital Pulse Oximeter. English

DINAMAP ProCare Monitor. Operation Manual

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Model 900. Pulse Oximeter User s Manual

HANDY OX HAND HELD PULSE OXIMETER INSTRUCTION MANUAL. Model # 18715

PULSE OXIMETER PACKAGE

HFX Fiber Optic Component 50 Mbps, 650 nm LED

OMNI Express VS VERSATILITY IN VITAL SIGNS

Model 7500 Model 7500

1 Appendix - Product Specifications

Operator s Manual. Avant Digital Pulse Oximeter. English

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

Operator s Manual. 2500A PalmSAT. Pulse Oximeter with Alarms. English

signal extraction pulse oximeter OPERATOR S MANUAL

VitalCare 506N3 Series Patient Monitor Operator s Manual

Operator s Manual. LifeSense LS1-9R. Vital Signs Monitor. Capnography/Pulse Oximeter

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

OxiMax N-600x Pulse Oximeter with Alarm Management System

Visit us at testo 835 Infrared and contact thermometer

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Fiber Optics and Liquid Level Sensors Line Guide

Technical Data Sheet Opto Interrupter ITR

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

INFRARED HEATERS APPLICATIONS INFRARED HEATING

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

AV6416 OTDR. Product Overview: Main Features:

Technical Data Sheet 3mm Phototransistor T-1

Spectrum Detector, Inc.

CLEO VERSATILITY IN VITAL SIGNS

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Infinity M300 Patient Worn Monitoring

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

HBP Patient Monitor. Operator s Manual. EU representative OBELIS S.A Bd. Général Wahis, Brussels, Belgium.

V202 HANDHELD PULSE OXIMETER OPERATING MANUAL QAB/V

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Operator s Manual. Model 7500FO. Model 7500FO. Digital Pulse Oximeter. English

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

with color display signal extraction pulse co-oximeter with Rainbow Technology OPERATOR S MANUAL

DINAMAP PRO Series V2 Monitor. Operation Manual

Transcription:

Global Standard Quality : Healthcare is our Business OXIPRO is a Disposable PulseOximeter sensor which have various advanced biocompatibility and function, provides early information on problems in the delivery of oxygen to the tissue. Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,

Features & Benefits Designed for optimal comfort and accuracy. Compatible with major leading manufactures of pulse oximetersystem. Bright, highquality LEDs to maximize signal tracking capabilities. Four different bandage styles permit monitoring of all patient populations. Provide a costeffective. Gold plated connector pin. Applied evaporation elastic cotton tape. Onepiece bandage construction with visible alignment marks for easeof use and patient comfort. Builtin shielding for both the photodiode and the cable to protect the signal during transmission. Specification Accuracy LED Wave length 100% SaO2 (±2 digits) 100% SaO2 (±3 digits) 0 % SaO2 (unspecified) Red LED IR LED Lead Wire adult, infant, pediatric neonate 660 nm nominal 0 nm nominal Connector A custom 9 pin DSub connector, Male, Length 0.95M Photodiode Active Area OXIPRO DA OXIPRO DN 3 3 mm2 120 16 mm 120 14 mm Mediplast tape Dimensions OXIPRO DP OXIPRO DI OXIPRO DAC OXIPRO DPC 86 66 mm 65 66 mm 86 66 mm 65 66 mm Maximum Power dissipation of LED Radiant intensity(po) 120mW 0.2mW(Red) / 0.3mW(IR) (IF=20mA) Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,

OXIPRO OXIPRO D Series OXIPRO DA OXIPRO DN OXIPRO DAC, DPC OXIPRO DI OXIPRO DP OXIPRO R Series OXIPRO RA OXIPRO RP Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,

OXIPRO Elite Sensor Specification PARAMETER Distrib. Symbol Min Old Typ Max Min New(Elite) Typ Max Unit Peak Emission Wavelength IR LED RED LED λp 657 8 672 0 658 5 660 910 662 Nm Spectral Bandwidth IR LED RED LED Δλ 30 30 30 10 Nm It is extremely important that the RED LEDs used in pulse oximeter probes emit a very narrow range of wavelengths centered at the desired 660nm in order to minimize error in the SpO2 reading, which is the pulse oximeter s estimation of arterial oxygen saturation. Typical LEDs have a spectral bandwidth in the range of 60nm to less than 20nm, with visible LEDs usually having smaller bandwidths of approximately 25nm and IR LEDs typically having larger bandwidths near 50nm, but a better than accuracy for neonate, we will change new Red LEDs that having bandwidths of approximately 10nm.(Previous RED LED having bandwidths of approximately 30nm) Test Result to neonate Old New(Elite) Nellcor Response time 8~10 sec after appear R curve 4~5 sec after appear R curve 4~5 sec after appear R curve Wave peak Intermittent or flat peak (no signal) Error at Low Perfusion Always 15~20% high SpO2 value to low SaO2 value Bandage Adhesions 0.3 kgf (Peel strength from skin) 0.45 kgf (Peel strength from skin) 0.2 kgf (Peel strength from skin) Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,

OXIPRO Elite Comparison SpO2 Value Simulator Value OXIPRO(General) OXIPRO(Elite) Nellcor 98% 75BPM 98 98 % 75BPM Normal % 75BPM 84% 75BPM 91 84 84 83 80% 75BPM 80 80 79 % 75BPM 68 Neonate/Shiver % 180BPM 91 95 Neonate % 180BMP 91 Hypoxic/Shiver % 95BPM 71 Hypoxic/Tap % 95BPM Hypoxic % 95BPM 71 Brad/Shiver % 45BPM Brad % 45BPM Weak/Shiver % 95BPM 93 92 Weak/Tap % 95BPM 93 92 Weak % 95BPM 92 91 Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,

COMPATIBLE MONITOR LIST Manufacture Monitor model Extension cable Philips (HP) 78352C, 78354C, 734C, M1020A, M1205A, M1205B, M1350B, M1722A/B, M1732A/B, Viridia A1, Viridia A3 M2601A, M3000A, M3500B, M4735A, M2475B, M4529A, MP20, MP30, MP40, MP60, MP, MP80, MP, M3,M4 N10, N20, N20PA, N100, N180, N1, N200, NBP40/45, NBP75, NBP1/195, NBP30, NBP4000, Monitor with Nellcor module Nellcor NBP2/295, NBP3/395, N3000, N6000,N65 N550, N595, All Nellcor OXIMAX SC6000, SC6002XL, SC00, SC8000, SC00XL Siemens & Drager Vitalert 1000, Cicero, Narkomed, Vitara, PM8014, PM8060 Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,

COMPATIBLE MONITOR LIST Manufacture Monitor model Extension cable Dinamap /9710/9720, Plus, Compact TS, MPS, Dinamap Pro 300/400 GE Medical (Marquette, Critikon, Corometrics, Datex) Eagle, Dash, Solar, Tram modular x50sl series (250SL,450SL,650SL,850SL,850A,451N) (Do not work Dash 5000, Solar 00, PDM modular series) Corometrics 1, 128, 128F, 129, 129F AS/3, CS/3, CH/S, CH/2S, CHRS, CG/2S, CardiocapI, CardiocapII, Cardiocap 5, Capnomac Ultima, Light Monitor, MEstpr, OscarII, SatliteTrans, Satlite Trans puls, ULTSVI, ULTSVO, ULTSIO, ULTS00, OSP200 NONIN 8500, 8600, 80, 00 SpaceLabs PC scout, 3506, 465, 466, 467, 468, 489, 651A08, 43XMTR, 351, 411, 617, 496 Head Office : 16547 Donghwa Medical Instrument Complex, Donghwari Munmakeup, Wonjusi, Gangwondo,