EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

Similar documents
Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Power Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)

Power Factor (1) 350 ma 90 ~ 132 Vac 34~68 Vdc 24 W 85% 0.95 LLC-024S035RSP. Max. Output Power. Efficiency (1)

TROPO 15W Dimmable LED Driver

Introduction. LHP Ultra High Input Voltage Drivers. Application:

Linear Lighting Pro Dimmable Series XLAV80. Constant Voltage Dimmable LED Driver. Features. Model Selection Key 80-BCV-D

DALI Interface Dimmable Electronic Ballasts for Fluorescent Lamps / Compact Lamps. Approvals:

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Max Load. Max. Load. Red (+) Black (-) Gray Violet. Part number: CV 96 24DC. Solidrive constant voltage 0-10V dimmable LED driver


ELLA ID. High CRI, High lm/w OptoDrive LED-module

Iout ( Per Channel) (A) Channel(s) Output

Flame Simulator User Manual. Publication Rev. A

Buzzer Unit. TAN-5000 Series. Operating Manual

QTi DALI 4X14/24 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

PRODUCT DATASHEET QTi DALI 4X14/24 DIM

QTi DALI 2X21/39 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

LORAIN CIP 4890/48120 DC Power System

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

S R 8 Circular LED Engine Product Specification

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

SMT LED DRIVERS Product Guide

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

MD-MINI Dry Bath. Instruction Manual

QTi DALI 1X58 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T8 ECG dimmable DALI for FL 26 mm

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

QTi DALI 1X35/49/80 DIM

LORAIN CSP DC Power System

ESP TECHNOLOGIES LIMITED

SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS

2016 Edition V3.0 LED DRIVER PRODUCT CATALOGUE

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

QTi DALI 1X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

QTi DALI 2X28/54/ DIM

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

DHL-LP-LED Low Profile LED Linear High/Low Bay

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

P5500 LED Architectural Downlighting

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

SPECIFICATION FOR APPROVAL

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

EcoSystem H-Series Ballasts

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

LED IMPORTANT SAFETY INSTRUCTIONS

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Specific Lighting Product Data Sheet M08 CoB Product Series Data Sheet Spec No.: DS Effective Date: 12/15/2016 LITE-ON DCC RELEASE

Installation Instructions Lithonia Lighting Clean Room Troffer. Grid & Sheet Rock Installation, Maintenance

Wood pellet and biomass system ceramic igniter

MaxLite LED High Bay Fixtures

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

DHL-LP-LED Low Profile LED Linear High/Low Bay

DIMMING 0-10V Continuous

DMFPM-2R MULTIFUNCTIONAL

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

Instruction Manual (Supplementary) Open Type Inverter

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Analog Room Pressure Monitor RPC Series

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Vaux Programming. TDD-ANPNx. Vdim+ Return. Connection to LED driver Connection to Control Model Number

SAFEVIEW-MINI2 TRANSILLUMINATOR

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Datasheet: K-22 LO Sensor

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

INSTRUCTION MANUAL MNBX14

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

HEP Tech Co., Ltd. Company Profile

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

Thermo-Sealer. Manual Heat Sealer. User Manual

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

½ Monitored Pneumatic Valves On Series Ported Manifold

LED Linear Design Highlights

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

E3M-V. Mark Sensor. Applications

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

For more information, please visit 3-form.com or call

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

SHUTTLE BELL-PRESS DIMMER DATA SHEET

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Installation instructions

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

LED IMPORTANT SAFETY INSTRUCTIONS

Instructions for the fan motor control system with integrated wiring terminals SILVER C

SPECIFICATIONS Compliance & Regulatory Approvals DIMMER MODELS TRIM PLATES (SOLD SEPARATELY) SYSTEM DIAGRAM. Input. Output. Environmental Requirements

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

Transcription:

PIFE-W037D Flat 35W LED Driver 24V - 34V / 1.04A / 35W Features Dimmable Method: DALI Dimming Constant Current Control Active Power Factor Correction Protection : OVP, SCP and OTP Mechanical Outline (Metal Case) - 360 30 26mm EN 61347-1, EN 61347-2-13, DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant Electrical Specifications Output [W] Output [Vdc] Output [A] Input [Vac] Dim. Method PF Efficiency [%] Mechanical Outline [LxWxH mm] 35 24-34 1.04 120-277 DALI >0.9 Min. 80 360 30 26 Input Specifications Parameter Min Typ. Max Unit Remark Input Voltage (Nominal) 120-277 Vac Input Voltage (Safety variation) 108-305 Vac Input Current - - 0.47 A @ AC 120-277V Input Wattage - - 46 W @ AC 120-277V Input Frequency 47 50/60 63 Hz Efficiency 80 - - % Power Factor 0.9 - - - THD - - 25 % @ AC 120-277V, 70-100% Load @ AC 120-277V, 70-100% Load @ AC 120-277V, 70-100% Load Inrush Current - - 60 Apk Note : All parameters NOT specially mentioned are measured at rated load and 25 of ambient temperature. 1 / 8

Output Specifications Parameter Min Typ. Max Unit Remark Output Voltage 24 29 34 V Output Current Range - 1.04 - A Fixed Current Output Dimming Current Range 10-100 % DALI Output Current Tolerance -5 - +5 % @ 100% Dimming Output Ripple Current - - 30 % Output Power - - 35 W = Peak to Peak / rms @ 100% Dimming Start-up Time - - 1,500 ms @ 100% Dimming Protection Functions Parameter Min Typ. Max Unit Remark Output Over Voltage Protection - - 42.4 V Auto Recovery Output Short Circuit Protection - - 2.2 A Auto Recovery Output Over Temp. Protection 90-100 (Tc) 1. 90 Tc 100 : LED Current 60% 2. 100 < Tc: Shut Down Environmental Specifications Parameter Min Typ Max Unit Remarks Temperature Operation -20-55 @ Ta - - 80 @ Tc Storage -35-85 @ Ta Humidity Operation 10-90 % - Storage - - 95 % - Lifetime 50 - - khrs @ Tc=80 Note : All parameters NOT specially mentioned are measured at rated load and 25 of ambient temperature. 2 / 8

Standards Parameter Condition Remark Safety Standards EMI / RFI Standards Design to meet the requirements as follows ; - EN 61347-1, EN 61347-2-13 - SELV Output - DALI 102/207 - KS: KS C 7655 Design to meet the requirements as follows ; - EN 55015:2006+A1+A2 - EN 61547:2009 - EN 61000-3-2:2006 - EN 61000-3-3:2008 - KS: KS C CISPR 15, KS C IEC 61547 Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment. 3 / 8

Power Factor Characteristics Efficiency Characteristics 4 / 8

LED current LED current Flat Dimming Control (DALI) PWM Condition Article Min Typ Max Remark Dimming Frequency - 300 - Hz No Flicker & Shimmer Dimming 10 100 % LGIT recommend range DALI have two kinds of basic dimming mode. 1) Log scale dimming mode (basic condition) 2) Linear scale dimming mode 1) Log scale dimming mode s table 2) Linear scale dimming mode s table Dec value Dec value User s DALI POWER_ON Prohibition using Level (it protect to be under 10% Dimming case) 1) Log scale dimming mode : 1~169 2) Linear scale dimming mode : 1~24 5 / 8

Mechanical Outline 1. Case Dimension WIRE SPECIFICATION PE WIRE : UL3386 #18 AWG, Stranded Wire OUTPUT WIRE(VLED) : UL1007 #22 AWG, Stranded Wire OUTPUT WIRE(DALI) : UL1007 #22 AWG, Stranded Wire with Tube 2. Connector Wiring Diagram 6 / 8

Caution Storage 1) Suitable for indoor use or outdoor use without direct sunlight exposure 2) This product should not be exposed to sulfur. Transportation 1) Be careful to give mechanical vibration and shock as less as possible and not to drop this product. 2) Static electricity or surge voltage may damage the components inside this product, as such please observe proper anti-electrostatic working process. - People handing the Driver should be well grounded and wear anti-static working clothes and gloves. - All related devices and instruments in the production line should be well grounded. Installation 1) Be careful not to warp or bend this product at assembly. 2) Be careful not to apply stress to the parts such as connectors at assembly. 3) Please note these guidelines and precautions. It is required to be assembled by experienced workers. - Check the power cord is disconnected from the power outlet when this power supply is being installed. - Do not use a damaged input and output lines. If it is damaged, change the power supply through the supplier. - Check the input and output lines are connected correctly. 4) Observe the correct polarity of output terminal. 5) Do not modify this product. It causes a fire and the electric shock. 6) Turn off the power before exchanging LED lamps. 7) The Protective Earth(PE) must be securely connected to Frame Ground(FG) in case the driver is certified with class I (i.e. inclusive of a PE contact) Use Conditions 1) This product must be used within the specification. Any defects or damages resulting from abnormal conditions will not be covered by warranty - In case of the product with latch off function can be shut down under abnormal situations. Under this situation please restart the power supply, after resolving abnormality. 2) This product is for general electronics equipment such as Audio-Visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for medical equipment, space equipment, nuclear equipment or disaster prevention equipment, please contact LG INNOTEK in advance. 3) This product is designed and intended to operate LED loads only. Non-LED loading may be outside the specified design limits of our LED driver, and therefore cannot be covered by the warranty. If you desire to use our product to operate non-led loads please contact us to discuss compatibility. 4) This product is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must re-qualify EMC Directive on the complete installation again. 7 / 8

Datasheet Revision History Change Date Rev. No. Description of Change Remark 2014/09/22 1.0 - Initial Release 2015/11/09 2.0 Added and revised below information, - Caution - Certification for KS 8 / 8