MGD Gas Chromatograph

Similar documents
ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Pioneer-R16 Gas Monitor Operator s Manual

Pump-Up Controller MODEL 4062

Pump-Down Controller MODEL 4052

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Sample Draw Aspirator Adapter Operator s Manual

ACT2-CS Convenience Store Controller

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

USER MANUAL MINITRACER PORTABLE SNIFFER

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

DC200 Digital Dispenser Operating Manual

ph COOLING TOWER CONTROLLER

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

CALIDUS tm the Modular micro Gas Chromatograph

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Product Manual SZ1145

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

A-09 Sample-Draw Detector

Mudlogging Equipment Comparison Chart

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

GasAlertMicroClip X3 Specifications

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Product Manual SZ1144

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Ronan Model X96S Series Density System

HPLC Column Ovens and Temperature Controllers

Ronan Model X96S Series Weighing System

Beacon 800 Gas Monitor Operator s Manual

PURGE/PRESSURIZATION SYSTEM

Oakton TEMP 9500 Advanced Multiparameter Controller

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

CAUTION & SYMBOL DEFINITIONS:

Beacon 110 Gas Monitor Operator s Manual

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

Operations Manual DS 220. Docking Station for Micro IV

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Combustible Gas Sample-Draw Detector Operator s Manual

FIXED GAS ANALYZER (FGA)

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Carbon Dioxide Sample-Draw Detector Operator s Manual

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Sierra Series 900 Single & Dual Channel System. Instruction Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

P6500W Air Dryer User s Guide

UDC100 Universal Digital Controller Specifications

RKA-03 Sample-Draw Detector Head

ANALOX 3000 Carbon Monoxide Monitor

Process Gas Chromatograph

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

ALTAIR 5X Multigas Detector Product Specification

EXAMPLES OF HOW TO ORDER

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Operation Manual. (Version 1.5.1)

EXAMPLES OF HOW TO ORDER

Analog Room Pressure Monitor RPC Series

Aquapurification.com. Ozone. Ozonation Process: SGA Series: Ozone/Oxygen Systems:

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

TV2 Room Pressure Monitor Quick Start Guide

Troubleshooting Thermo Scientific LevelPRO Gauges

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

HFID Heated Total Hydrocarbon Analyzer Module

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

Series 5000 Hydrazine Analyzer Model 60002

Intelligent 2 & 4 Loop Fire Alarm Control Panels

GAS MONITOR Model Model

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Air Resource Specialists, Inc.

RLD-H10P Refrigerant Leak Detector

RELEASE DEVICE CONTROLS

P4200PM / P5000PM Remote Air Dryer User s Guide

Intelligent Single Loop Fire Alarm Control Panel

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

RAM 50 Series Operation Manual

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Dometic Manual Refrigerators

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

P4200W2 Series Air Dryer

RKA-LEL Sample Draw Combustible Gas Detector

π H-7241 AIR CUSHION MACHINE PARTS uline.com BOX CONTENTS

Transcription:

MGD Gas Chromatograph The MGD Precision gas system is the latest in a series of gas detection systems that have been designed for the mud logging industry. This system has retained the simplicity of the past and the innovation and technology of the present to develop the easiest to use and the most reliable gas instrument of the industry. This system has been designed with field service in mind. By incorporating both the total gas detector and the gas chromatograph into the same chassis, flow plumbing problems have been eliminated. By incorporating a high and low gas filament in the design dilution has become unnecessary. All flow components are easily cleaned and all internal plumbing is ¼ inch plastic tubing. The detectors used are the ceramic bead detector for both the CC and the chromatograph, and the TC is a long life platinum wire detector. The gas detector has separate zero controls and amplifiers for the CC, TC, and chromatograph. The chromatograph is microprocessor controlled for precise timing and utilizes a low cost and easily available gas chromatograph column.

SYSTEM REQUIREMENTS: Voltage: 120 VAC 60 Hz Dry Compressed Air: 20 TO 40 PSI SPECIFICATIONS: DIMENSIONS: WEIGHT: 19 inches wide 7 inches high 12 inches deep 20 lbs DETECTORS: CC Ceramic Bead TC Platinum wire RANGE: 1% Methane standard CC detector 0-1000 units TC detector 0-10000 units FEATURES: Separate zero controls and amplifiers for each detector Adjustable audible alarm set point Simultaneous outputs for CC, TC and chromatograph as well as one manually switch able output for TC and CC 0-5 vdc output full scale for each detector (unranged) Recorder output 0 100 mvdc (.1vdc) ranged (adjustable) CC/TC status dry contact output Sample and elute status LEDs

1.Pressure gauge 2.Pressure regulator 3.Chromatograph zero controls 4.Chromatograph range switch 5.Sample indicator LED 6.Elution status LED 7.Chromatograph cycle control 8.Integrator start pulse switch 9.Flowrater 10.Alarm set point control 11.Total gas range switch 12.Alarm status switch 13.CC/TC selector switch 14.TC zero control FRONT PANEL:

15.CC zero control 16.1 amp fuse socket 17.Power switch 18.Speaker with volume control 19.Total gas gauge 20.Chromatograph gauge BACK: Sample in: Connected to gas flow line Sample out: Exhaust, flows out of the trailer Chrom exhaust: Exhaust, flows out of the trailer Air: Connected to air compressor Mainlog Output: CC+ to Acromag 13 In0+ CC- to Acromag 14 In0- TC+ to Acromag 25 In3+ TC- to Acromag 26 In3- Remote+ to Acromag 41 OUT0 Remote- to Acromag 43 Rtn

CH+ to Acromag 15 In1+ CH- to Acromag 16 In1- INITIAL SET UP: 1.Turn the power switch (17) to on and allow the MGD precision gas detector to warm up for no less than 90 minutes. 2.Connect the sample pump to sample in on the gas detector and pump only fresh air and no well bore gas into machine 3.Set the flow rater (9) to 2.5 SCFH. 4.Adjust the pressure regulator (2) till the pressure gauge (1) reads the correct pressure as designated by the label on the back of the pressure gauge or calibration sheet. 5.Zero the chromatograph by adjusting the zero knob (3) until the chromatograph gauge (20) reads 0 units 6.Select TC mode by switching the selector switch (13) to TC. Zero the TC Sensor with the TC Zero control (14) until the total gas gauge (19) reads 0. 7.Select CC mode by switching the selector switch (13) to CC. Zero the CC Sensor with the CC Zero control (15) until the total gas gauge (19) reads 0. The gas detector is now warmed up, zeroed, set to calibrated flows, pressures, and is now ready for operation. NORMAL OPERATION: 1.Connect the gas flow line into the gas detector line labeled sample in. 2.Reset the flow rater (9) to 2.5 SCFH.

3.Set the alarm to the desired setting by holding the alarm status switch (12) down to alarm set while dialing the set point knob (10). The setting will display on the total gas gauge (19) and the alarm can be toggled on or off with the status switch (12). 4.Set the chromatograph cycle control (7) to auto for machine control, to manual for mainlog control or external control, or hold the switch down to start a cycle. The elute LED flashes indicating the column is purged the sample LED and elute LED s remain lit during a cycle. 5.As the outdoor temperature changes so will the density of the air and gas flowing through the gas detector, it might be necessary to re-zero the gas detector by following steps 2-7 in the initial set up. TROUBLESHOOTING: 1. Back up or save the log on the logging software 2. Verify machine has warmed up by feeling the bottom or left side of the gas detector and making sure this is warm to touch 3. Re-zero the gas detector by following steps 2-7 of the initial set up. 4. Close all other software programs besides logging software. 5. Verify column pressure on pressure gauge (1) 6. Verify that the chromatograph needle on gauge (20) moves during elution. 7. Check connections from machine to A/D DAQ to PC computer. 8. Verify correct settings in logging software (elution times, spans, cycle times, max readings, auto TC, test gas values, ect). 9. Reboot PC, DAQ, and cycle gas detector off and on and verify problem still exists. 10. Call tech support

Ben Baggs MGD Systems 3603 National Parks Highway 575-887-1483