697C (60 HZ) Sizes 018 thru 060

Similar documents
563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

A 14 SEER Heat Pump with R---410A Refrigerant Series

R4H4. Product Specifications

Product Data. Efficiency. S S Reliability

R4H4. Product Specifications

Product Data. Efficiency

WCH5**4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

N4H4. Product Specifications

Product Data. Efficiency

Advance Product Data

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

Product Data. Efficiency

2 shp 13 lc 1 36 t - 1 a

N4A6. Product Specifications

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. Efficiency

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

R 410A Ducted Horizontal Air Conditioner

Product Data INDUSTRY LEADING FEATURES / BENEFITS

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL SPECIFICATIONS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Advance Product Data

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Installation Instructions

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Split System Heat Pump Product Data

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

Split System Cooling Product & Performance Data

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

TECHNICAL SPECIFICATIONS

Split System Heat Pump Product Data

Advance Product Data

Transcription:

SPLIT-SYSTEM HEAT PUMP UNITS 697C (60 HZ) s 018 thru 060 The AeroQuiet System (AQS) consists of 4 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening and wire dome top results in quieter and more efficient operation. Energy-Efficient Fan and Fan Motor provide a slower fan operation, thus reducing noise and improving efficiency. Sound Hood muffles noise from operation. Discharge Muffler minimizes low frequency sound and pressure pulsation generated by compressor discharge gas. The 697C Outdoor s of Split-System Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. These heat pump systems provide economy of operation through energy conservation with SEER up to 15.0 and HSPF up to 9.2. They recover heat for indoor comfort from outdoor air during the heating season and, by automatically reversing the refrigerant system, remove indoor heat and excess humidity during the cooling season. All models are listed with UL (U.S. and Canada), ARI, and CEC. FEATURES ELECTRICAL RANGE All units are single phase 208/230v. COMPRESSOR This unit features a scroll compressor, which is significantly more efficient than conventional compressors. Its simple design offers improved reliability. Each compressor is mounted on rubber isolators for additional sound reduction. The scroll compressor starts under most system loads, thus eliminating the need for start assistance components. For improved serviceability, all models are equipped with a compressor terminal plug. Continuous operation is approved down to 30 F ( 34.4 C) in the heating mode and down to 55 F (12.8 C) in the cooling mode. (See heating and cooling performance tables.) The scroll compressor is covered with a standard 10-year limited warranty. BUILT-IN-RELIABLE COMPONENTS All units include a suction tube accumulator that minimizes the amount of liquid refrigerant that reaches the compressor; a high-pressure switch for high-pressure protection; and a low-pressure switch for loss of charge protection. THERMOSTATIC EXPANSION VALVE (TXV) This unit must be installed with a TXV on the indoor coil. The FC4 and FK4 indoor fan coils come factory equipped with a bi-flow TXV. When installed in this application, no further change is required. If any other indoor fan coil or furnace coil is used, an accessory bi-flow TXV must be installed. See accessory list in this publication for correct part number. WEATHER-PROTECTIVE CABINET The casing steel is galvanized and coated with a layer of zinc phosphate. A modified polyester powder coating is then applied and baked-on, providing each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rust-resistant, quality appearance. COIL PROTECTION The DuraGuard coil protector, made of a 12 gage coated steel wire grid with vertical 3/8-in. spacing, is designed to help protect the coil from inclement weather, vandalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning. UNIT DESIGN All units are equipped with totally enclosed fan motors for greater reliability under rain and snow conditions. The large, wraparound coil uses copper tube and enhanced aluminum fin and is designed for optimum heat transfer during heating and cooling. The vertical air discharge carries the sound and air up and away from adjacent patio areas and foliage. Rows of composite coils can be cleaned with a common garden hose. EXTERNAL SERVICE VALVES Both service valves are brass, back seating type with sweat connections. Each valve has a service port for ease of checking operating refrigerant pressures. The suction service port provides for ease of checking operating pressure in the heating mode. LIMITED WARRANTY Standard 5-year limited warranty on all parts, with a 10-year limited warranty on compressor. Form No. PDS 697C.18.5

DIMENSIONS NOTES: 1. Allow 30 in. clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F (unless low ambient control is used) max 125 F. Maximum outdoor operating ambient in heating mode is 66 F. Series designation is the 14th position of the unit model number. Center of gravity. 3. 4. 5. 3/8 IN. DIA (9.5) TIEDOWN KNOCKOUTS (2) PLACES IN BASEPAN FIELD POWER SUPPLY CONN 7 /8 IN. DIA (22.22) HOLE WITH 1 1/8 IN. DIA (34.92) KNOCKOUT AND 1 3/8 IN. DIA KNOCKOUT C 2 1 /2" L B DISCHARGE IN 1 9 /16" DISCHARGE ACCESS PANEL FIELD CONTROL SUPPLY CONN K 7/8 IN. DIA HOLE D A H DIA SUCTION LINE CONN C L IN G F 3/8 IN. DIA LIQUID LINE CONN A94148 E M 10 1 /2" 4" DISCHARGE 8 3/16" IN 1 1 /4" 1 3 /4" N DIMENSIONS (IN.) MINIMUM MOUNTING UNIT DIMENSIONS PAD DIMENSIONS A B C D E F G H K L M Support Feet Snow Stand UNIT SIZE SERIES 018 D, E 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 5/8 16-13/16 20-1/2 11 26 x 32 31 x 35 024 D, E 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 3/4 16-13/16 20-1/2 14 26 x 32 31 x 35 030 D, E 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 3/4 16-1/2 20-3/8 16 26 x 32 31 x 35 036 E, F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 16 26 x 32 31 x 35 042 E, F 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 7/8 16-1/2 20-3/8 15 26 x 32 31 x 35 048 D, F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 15-13/16 19-7/8 16 26 x 32 31 x 35 060 E, F 39-13/16 38-5/8 42-1/16 7-1/8 12-1/8 27-15/16 34-3/8 7/8 19-7/8 26 17-1/2 32 x 42 36 x 46, F 2

RECOMMENDED TUBE DIAMETERS UNIT TUBE LENGTH LIQUID TUBE VAPOR TUBE SIZE (Ft)* DIAMETER (In.) DIAMETER (In.) 018 5/8 024, 030 3/4 0 to 50 3/8 036-048 7/8 060 1-1/8 * For tube set over 50 ft. or 20 ft. vertical differential, consult Long-Line Application Guideline. UNIT SIZE METERING DEVICE OUTDOOR PISTON INDOOR TXV* SERIES 018 D, E 42 KHATX0601HSO 024 D, E 49 KHATX0601HSO 030 D, E 52 KHATX0601HSO 036 E, F 59 KHATX0601HSO 042 E, F 63 KHATX0601HSO 048 D, F 70 KHATX0701HSO 060 E, F 73 KHATX0701HSO * TXV must be installed when indoor coil is not equipped with a TXV. TXV listed is for any approved coil combination. All TXVs are bi-flow, hard shutoff. UNITARY HEAT PUMP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. * As an ENERGY STAR SM Partner. Bryant and Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency. REGISTERED QUALITY Refer to the combination ratings in the Product Data Sheet for system combinations meeting ENERGY STAR efficiency standards. * This unit can be used as part of a Perfect Heat / Perfect Humidity System. This system can remove up to 12 gallons more moisture per day than a standard system. It can also provide superior supply air temperatures in the heating mode. To learn how to receive truly remarkable comfort, see the FK4C product data sheet. 3

SPECIFICATIONS UNIT SIZE-SERIES 018-D, E 024-D, E 030-D, E 036-E, F 042-E, F Shipping Weight (Lb) 178 198 213 216 236 ELECTRICAL Unit Volts-Hertz-Phase 208/230-60-1 Operating Voltage Range 187 253 Unit Ampacity for Wire Sizing 13.0 16.5 19.0 21.0 32.0 Min Wire (60 C/75 C Copper) (AWG)* 14/14 14/14 14/14 12/12 8/10 Maximum Length (60 C/75 C) (Ft)** 61/58 46/44 41/39 60/57 97/59 Max. Branch Circuit Fuse (Amps) 20 25 30 30 50 Compressor Rated Load Amps 10.0 12.8 15.1 16.0 24.9 Locked Rotor Amps 45.0 63.0 72.5 88.0 104.0 Fan Motor HP and RPM 1/15 and 825 1/15 and 825 1/5 and 820 1/5 and 820 1/5 and 820 Fan Motor Rated Load Amps 0.5 0.5 1.0 1.0 1.0 COMPRESSOR AND REFRIGERANT Compressor Type Scroll Refrigerant Type and Amount (Lb) R-22 and 5.12 R-22 and 5.63 R-22 and 6.63 R-22 and 7.13 R-22 and 10.88 OUTDOOR COIL AND FAN Coil Face Area (Sq Ft) 12.17 15.21 18.25 18.25 15.15 Rated Airflow (CFM) 2000 2000 2000 2600 OPTIONAL EQUIPMENT Support Feet Kit 4 In. (4) KSASF0101AAA Snow Stand 18 In. KHASS0206MPK Time-Delay Relay KAATD0101TDR Outdoor Thermostat KHAOT0301FST Secondary Outdoor Thermostat KHAOT0201SEC Cycle Protector Standard Crankcase Heater KAACH1201AAA Start Assist PTC KAACS0201PTC Start Capacitor and Relay KSAHS1501AAA Sound Hood Standard Bi-flow TXV Kits (Hard Shutoff) KHATX0601HSO Bi-flow TXV Kits (RPB) N/A Low-Ambient Pressure Switch KSALA0201R22 High-Pressure Switch Standard Evaporator Freeze Thermostat KAAFT0101AAA Isolation Relay KH0101AAA Liquid Solenoid Valve KHALS0101LLS Filter Drier Bi-flow P504-8083S (RCD) P504-8163S (RCD) MotorMaster Control*** 32LT660004 Ball Bearing Fan Motor N/A HC38GE231 (RCD) See notes on page 5. 4

SPECIFICATIONS Continued UNIT SIZE-SERIES 048-D, F 060-E, F Shipping Weight (Lb) 270 332 ELECTRICAL Unit Volts-Hertz-Phase Operating Voltage Range Unit Ampacity for Wire Sizing 32.8 45.0 Min Wire (60 C/75 C Copper) (AWG)* 8/10 6/8 Maximum Length (60 C/75 C) (Ft)** 94/58 116/66 Max. Branch Circuit Fuse (Amps) 50 60 Compressor Rated Load Amps 25.4 34.9 Locked Rotor Amps 137.0 169.0 Fan Motor HP and RPM 1/5 and 820 1/5 and 820 Fan Motor Rated Load Amps 1.0 1.4 COMPRESSOR AND REFRIGERANT Compressor Refrigerant Type and Amount (Lb) R-22 and 11.88 R-22 and 14.88 OUTDOOR COIL AND FAN Coil Face Area (Sq Ft) 18.25 24.89 Rated Airflow (CFM) 2800 3600 OPTIONAL EQUIPMENT Support Feet 4 In. (4) KSASF0101AAA Snow Stand 18 In. KHASS0206MPK KHASS0306MPK Time-Delay Relay KAATD0101TDR Outdoor Thermostat KHAOT0301FST Secondary Outdoor Thermostat KHAOT0201SEC Cycle Protector Standard Crankcase Heater Standard Start Assist PTC KAACS0201PTC Start Capacitor and Relay KSAHS1701AAA KSAHS1601AAA Sound Hood Standard Bi-flow TXV Kits (Hard Shutoff) KHATX0701HSO Bi-flow TXV Kits (RPB) N/A Low-Ambient Pressure Switch KSALA0201R22 High-Pressure Switch Standard Evaporator Freeze Thermostat KAAFT0101AAA Isolation Relay KH0101AAA Liquid Solenoid Valve (LSV) KHALS0101LLS Filter Drier Bi-flow P504-8163S (RCD) MotorMaster Control*** 32LT660004 Ball Bearing Fan Motor HC38GE231 HC38GE232 (RCD) * If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). If other than uncoated (non-plated), 60 or 75 C (140 or 167 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, see Long-Line Application Guideline for additional refrigerant requirements. Time-delay fuse or circuit breaker. ** Length shown is as measured 1 way along the wire path between the unit and the service panel for voltage drop not to exceed 2%. Used with low-ambient controller. *** Fan motor with ball bearings required. N/A Not Applicable 5

THERMOSTATS AND ACCESSORIES Thermostat Auto Changeover, Non-Programmable, F/ C, 2-Stage Heat, 1-Stage Cool Thermostat Auto Changeover, 7-Day Programmable, F/ C, 2-Stage Heat, 1-Stage Cool Thermostat Auto Changeover, 7-Day Programmable, F/ C, Dual Fuel, Includes Outdoor Sensor (TSTATXXSEN01) Thermidistat Control Non-Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 2-Stage Heat, 1-Stage Cool, Heat Pump Outdoor Air Temperature Sensor** Backplate for Non-Programmable Thermostat Backplate for Programmable Thermostat and Thermidistat Control Backplate for Builder s Thermostat Thermostat Conversion Kit (4 to 5 Wire) 10 Pack * Do not use in zoning heat pump applications. This plate is designed to cover surrounding wall area located behind thermostat. Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed. ** Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and builder s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat. ACCESSORY USAGE GUIDELINE * For tubing line sets between 50 and 175 ft, refer to Residential s Split System Long-Line Application Guidelines. For buried line applications, refer to local distributor. Only when low-pressure switch is used. TSTATBBNHP01-B TSTATBBPHP01-B TSTATBBPDF01-B* TSTATBBPRH01-B* TSTATBBBHP01* TSTATXXSEN01-B TSTATXXNBP01 TSTATXXPBP01 TSTATXXBBP01 TSTATXXCNV10 ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) Crankcase Heater Yes Yes Evaporator Freeze Thermostat Yes No Winter Start Control Yes No Accumulator No No Compressor Start Assist Capacitor and Relay Yes Yes MotorMaster Control Yes No Wind Baffle See Low-Ambient Instructions No Support Feet Recommended No Liquid-Line Solenoid Valve or Hard Shutoff TXV See Long-Line Application Guideline No Ball Bearing Fan Motor Yes No ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where low-ambient controller (full modulation feature) or MotorMaster Control has been added. 2. Compressor Start Assist-Capacitor/Relay Type Start capacitor and start relay gives hard boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Replacement installations with hard shutoff expansion valve on indoor coil. Units installed with low-ambient controller. Units installed with liquid solenoid valve. 3. Compressor Start Assist-PTC Type Solid-state electrical device which gives a soft boost to the compressor at each start-up. SUGGESTED USE: Installations with marginal power supply. Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 F (12.8 C) outdoor air temperature. (Use with low-ambient controller.) 5. Cycle Protector Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications. 6

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 6. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: With low-ambient controller. 7. Filter Drier Bi-flow A device for removing contaminants from refrigerant circulating in a heat pump system; 2-direction flow for heat pumps. SUGGESTED USE: Split-system heat pumps. 8. Isolation Relay An SPDT relay which switches the low-ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. SUGGESTED USE: All heat pumps where low-ambient controller has been added. 9. Liquid Solenoid Valve (LSV) An electrically operated shutoff valve to be installed at the outdoor unit and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. SUGGESTED USE: In certain long-line applications. (Refer to Long-Line Application Guideline.) 10. MotorMaster Control A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F, it maintains condensing temperature at 100 F ± 10 F. SUGGESTED USE: operation at outdoor temperatures below 55 F. All commercial installations. 11. Outdoor Thermostat An SPDT temperature actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point. SUGGESTED USE: Heat pump installations with multiple-stage supplemental heaters. 12. Secondary Outdoor Thermostat An SPDT temperature actuated switch which turns on a third stage of supplemental electric heaters when outdoor air temperature drops below the secondstage set point. SUGGESTED USE: Heat pump installations where 3-stage operation of supplemental heaters is desired. 13. Snow Stand Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base. SUGGESTED USE: Heat pump installations in heavy snowfall areas. Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 14. Sound Hood Wraparound sound reducing cover for the compressor. Reduces unit sound level by about 2 dba. SUGGESTED USE: Unit installed closer than 15 ft to quiet areas bedrooms, etc. Unit installed between 2 houses less than 10 ft apart. 15. Support Feet Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base; minimizes corrosion. SUGGESTED USE: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. 16. Thermostatic Expansion Valve (TXV) Bi-flow A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. SUGGESTED USE: Required for improved system performance. (Refer to ARI Unitary Directory.) Required for use on all zoning systems. 17. Time-Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. (Refer to ARI Unitary Directory.) UNIT SIZE SOUND LEVEL RATING SOUND POWER A WEIGHTED SOUND POWER LEVELS (dba) WITHIN OCTAVE BAND SHOWN 125 250 500 1000 2000 4000 8000 018 70 53.0 59.5 62.5 64.0 60.5 58.5 50.5 024 72 51.0 57.5 63.5 69.0 61.0 59.5 51.5 030 73 56.5 59.0 65.0 66.5 64.5 61.0 56.0 036 74 56.0 61.5 65.0 68.5 64.0 58.0 53.5 042 74 57.0 61.0 66.0 67.0 61.0 58.5 51.0 048 76 56.0 61.0 66.0 68.5 64.5 61.5 55.0 060 76 62.5 64.0 69.0 70.5 68.0 64.0 57.0 7

UNIT SIZE- SERIES 018-D, E 024-D, E See notes on page 16. INDOOR UNIT TC Factory- Supplied Enhancement COMBINATION RATINGS* Seasonal Efficiency SEER Standard Rating Field-Supplied Accessory TXV ARI STANDARD RATINGS* High-Temp Low-Temp TXV& TDR** EER CAP COP CAP COP Seasonal Efficiency HSPF/HSPF with LSV FC4(B,C)NF024 18,200 TDR & TXV 12.50 11.05 15,900 2.90 10,800 2.22 7.50/8.00 CC5A/CD5AA018 17,800 NONE 12.00 10.85 15,500 2.54 10,600 2.08 6.80/7.20 CC5A/CD5AA024 18,300 NONE 12.50 11.25 15,700 2.72 10,700 2.16 7.00/7.50 CC5A/CD5AW024 18,300 NONE 12.50 11.25 15,700 2.72 10,700 2.16 7.00/7.50 CE3AA024 18,400 NONE 12.50 11.25 15,700 2.74 10,700 2.18 7.00/7.50 CF5AA024 18,400 NONE 12.50 11.35 15,700 2.78 10,700 2.18 7.20/7.50 CK3BA024 17,600 NONE 12.50 11.05 15,600 2.84 10,500 2.20 7.20/8.00 CK5A/CK5BA018 17,300 NONE 12.00 10.85 15,500 2.72 10,500 2.14 7.00/7.50 CK5A/CK5BA024 18,100 NONE 12.50 11.05 15,600 2.84 10,500 2.20 7.20/8.00 CK5A/CK5BW024 18,100 NONE 12.50 11.05 15,600 2.84 10,500 2.20 7.20/8.00 F(A,B)4(A,B)N(F,C)018 17,600 TDR 12.00 10.65 15,600 2.62 10,600 2.08 6.80/7.50 F(A,B)4(A,B)N(F,C)024 18,200 TDR 12.50 11.05 15,900 2.90 10,800 2.22 7.50/8.00 FF1DNA018 17,800 TDR 12.50 11.30 15,400 2.70 10,400 2.16 7.00/7.50 FF1DNA024 18,600 TDR 13.00 11.45 15,800 2.86 10,700 2.22 7.50/8.00 FG3AAA024 18,200 NONE 12.50 11.10 15,600 2.70 10,700 2.14 7.00/7.50 FK4(C,D)NF001 19,000 TDR & TXV 15.00 13.15 14,800 2.96 9,900 2.30 7.50/8.00 FK4(C,D)NF002 19,200 TDR & TXV 15.00 13.30 14,900 3.08 9,900 2.34 8.00/8.50 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,300 TDR 13 11.55 15,000 2.62 10,100 2.16 6.8 CC5A/CD5AA024 17,900 TDR 13.5 11.95 15,200 2.84 10,200 2.24 7.5 CC5A/CD5AW024 17,900 TDR 13.5 11.95 15,200 2.84 10,200 2.24 7.5 CE3AA024 18,000 TDR 13.5 11.95 15,300 2.86 10,200 2.28 7.5 CK3BA024 18,300 TDR 14 12.2 15,500 3.06 10,300 2.34 8 CK5A/CK5BA018 17,800 TDR 13.5 11.85 15,400 2.9 10,200 2.28 7 CK5A/CK5BA024 18,300 TDR 14 12.2 15,500 3.06 10,300 2.34 8 CK5A/CK5BW024 18,300 TDR 14 12.2 15,500 3.06 10,300 2.34 8 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA024 18,600 TDR 14.00 12.50 15,200 2.86 10,200 2.26 7.50/8.00 CC5A/CD5AW024 18,600 TDR 14.00 12.50 15,200 2.86 10,200 2.26 7.50/8.00 CK3BA024 18,300 TDR 14.00 12.30 15,500 3.10 10,300 2.36 8.00/8.50 CK5A/CK5BA018 18,000 TDR 13.50 11.90 15,400 2.96 10,300 2.30 7.50/8.00 CK5A/CK5BA024 18,300 TDR 14.00 12.30 15,500 3.10 10,300 2.36 8.00/8.50 CK5A/CK5BW024 18,300 TDR 14.00 12.30 15,500 3.10 10,300 2.36 8.00/8.50 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA024 18,600 TDR 14.00 12.45 15,200 2.86 10,200 2.26 7.50/8.00 CC5A/CD5AW024 18,600 TDR 14.00 12.45 15,200 2.86 10,200 2.26 7.50/8.00 CK3BA024 18,300 TDR 14.00 12.25 15,500 3.08 10,300 2.36 8.00/8.50 CK5A/CK5BA018 18,000 TDR 13.50 11.85 15,400 2.94 10,300 2.28 7.50/8.00 CK5A/CK5BA024 18,300 TDR 14.00 12.25 15,500 3.08 10,300 2.36 8.00/8.50 CK5A/CK5BW024 18,300 TDR 14.00 12.25 15,500 3.08 10,300 2.36 8.00/8.50 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA024 18,600 TDR 14.00 12.50 15,200 2.86 10,200 2.26 7.50/8.00 CC5A/CD5AW024 18,600 TDR 14.00 12.50 15,200 2.86 10,200 2.26 7.50/8.00 CK3BA024 18,300 TDR 14.00 12.35 15,400 3.10 10,300 2.36 8.00/8.50 CK5A/CK5BA018 18,000 TDR 13.50 11.95 15,300 2.96 10,200 2.30 7.50/8.00 CK5A/CK5BA024 18,300 TDR 14.00 12.35 15,400 3.10 10,300 2.36 8.00/8.50 CK5A/CK5BW024 18,300 TDR 14.00 12.35 15,400 3.10 10,300 2.36 8.00/8.50 FC4(B,C)NF030 24,000 TDR & TXV 12.50 10.85 24,000 3.34 15,400 2.38 7.50/8.00 CC5A/CD5AA024 23,400 NONE 12.00 10.50 24,000 3.16 15,300 2.28 7.00/7.50 CC5A/CD5AA030 23,600 NONE 12.00 10.60 24,000 3.18 15,400 2.30 7.00/7.50 CC5A/CD5AA036 24,400 NONE 12.50 10.90 24,200 3.42 15,400 2.40 7.50/8.00 CC5A/CD5AW024 23,400 NONE 12.00 10.50 24,000 3.16 15,300 2.28 7.00/7.50 CC5A/CD5AW030 23,600 NONE 12.00 10.60 24,000 3.18 15,400 2.30 7.00/7.50 CC5A/CD5AW036 24,400 NONE 12.50 10.90 24,200 3.42 15,400 2.40 7.50/8.00 CE3AA030 23,800 NONE 12.00 10.70 24,200 3.32 15,400 2.36 7.50/8.00 CF5AA024 23,600 NONE 12.00 10.55 24,000 3.22 15,400 2.32 7.00/7.50 CK3BA024 23,200 NONE 12.00 10.55 23,800 3.26 15,300 2.34 7.20/7.70 CK3BA030 23,400 NONE 12.00 10.75 23,800 3.24 15,300 2.34 7.20/7.70 CK5A/CK5BA024 23,200 NONE 12.00 10.55 23,800 3.26 15,300 2.34 7.20/7.70 CK5A/CK5BW024 23,200 NONE 12.00 10.55 23,800 3.26 15,300 2.34 7.20/7.70 CK5A/CK5BA030 23,400 NONE 12.00 10.75 23,800 3.24 15,300 2.34 7.20/7.70 CK5A/CK5BW030 23,400 NONE 12.00 10.75 23,800 3.24 15,300 2.34 7.20/7.70 F(A,B)4(A,B)N(F,C)024 23,400 TDR 12.00 10.55 24,200 3.30 15,400 2.34 7.50/7.80 F(A,B)4(A,B)N(F,C)030 24,000 TDR 12.50 10.85 24,000 3.34 15,400 2.38 7.50/8.00 FC4(B,C)NF024 23,400 TDR & TXV 12.00 10.55 24,200 3.30 15,400 2.34 7.50/7.80 FF1DNA024 23,400 TDR 12.00 10.55 24,200 3.32 15,400 2.36 7.50/7.80 FF1DNA030 24,000 TDR 12.00 10.70 24,200 3.38 15,500 2.38 7.50/8.00 FG3AAA024 23,000 NONE 11.80 10.40 23,800 3.12 15,300 2.26 7.00/7.50 FK4(C,D)NF001 24,400 TDR & TXV 13.50 11.90 23,600 3.48 14,900 2.48 7.80/8.00 FK4(C,D)NF002 24,600 TDR & TXV 13.80 11.95 23,600 3.62 14,900 2.54 8.00/8.50 FK4(C,D)NF003 24,600 TDR & TXV 14.00 12.25 23,400 3.60 14,800 2.56 8.00/8.50 CE3AA024 23,400 NONE 12.00 10.50 24,000 3.14 15,400 2.28 7.50/8.00 8

UNIT SIZE- SERIES 024-D, E 030-D, E INDOOR UNIT TC COMBINATION RATINGS* Continued Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Field-Supplied Accessory TXV 9 ARI STANDARD RATINGS* High-Temp Low-Temp TXV& TDR** EER CAP COP CAP COP Seasonal Efficiency HSPF/ HSPF with LSV COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,800 TDR 13 11.65 23,000 3.18 14,500 2.36 7 CC5A/CD5AA030 23,600 TDR 13.5 11.65 23,000 3.22 14,500 2.4 7 CC5A/CD5AW024 23,400 TDR 13.5 11.45 23,000 3.18 14,500 2.36 7 CC5A/CD5AW030 24,000 TDR 13.5 11.8 22,800 3.22 14,500 2.4 7 CE3AA024 23,600 TDR 13 11.5 23,200 3.26 14,700 2.4 7 CE3AA030 23,800 TDR 13.5 11.7 23,200 3.38 14,700 2.44 7.5 CK3BA024 23,600 TDR 13.5 11.6 23,600 3.5 14,700 2.48 7.5 CK3BA030 23,600 TDR 13.5 11.65 23,000 3.36 14,700 2.46 7.5 CK5A/CK5BA024 23,600 TDR 13.5 11.6 22,800 3.5 14,700 2.48 7.5 CK5A/CK5BA030 23,800 TDR 14 11.65 23,200 3.36 14,700 2.46 7.5 CK5A/CK5BW024 23,600 TDR 13.5 11.55 23,600 3.5 14,700 2.48 7.5 CK5A/CK5BW030 23,600 TDR 13.5 11.65 23,000 3.36 14,700 2.46 7.5 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA030 24,200 TDR 13.50 11.60 23,400 3.34 14,900 2.42 7.50/8.00 CC5A/CD5AW030 24,200 TDR 13.50 11.60 23,400 3.34 14,900 2.42 7.50/8.00 CK3BA024 23,800 TDR 13.00 11.30 23,800 3.48 15,100 2.46 7.70/8.20 CK3BA030 24,200 TDR 13.30 11.60 23,600 3.48 15,000 2.48 7.70/8.20 CK5A/CK5BA024 23,800 TDR 13.00 11.30 23,800 3.48 15,100 2.46 7.70/8.20 CK5A/CK5BW024 23,800 TDR 13.00 11.30 23,800 3.48 15,100 2.46 7.70/8.20 CK5A/CK5BA030 24,200 TDR 13.30 11.60 23,600 3.48 15,000 2.48 7.70/8.20 CK5A/CK5BW030 24,200 TDR 13.30 11.60 23,600 3.48 15,000 2.48 7.70/8.20 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA030 24,000 TDR 13.30 11.55 23,400 3.32 14,900 2.40 7.50/8.00 CC5A/CD5AW030 24,000 TDR 13.30 11.55 23,400 3.32 14,900 2.40 7.50/8.00 CK3BA024 23,800 TDR 13.00 11.30 23,800 3.48 15,100 2.46 7.70/8.20 CK3BA030 24,200 TDR 13.30 11.55 23,600 3.46 15,000 2.48 7.70/8.20 CK5A/CK5BA024 23,800 TDR 13.00 11.30 23,800 3.48 15,100 2.46 7.70/8.20 CK5A/CK5BW024 23,800 TDR 13.00 11.30 23,800 3.48 15,100 2.46 7.70/8.20 CK5A/CK5BA030 24,200 TDR 13.30 11.55 23,600 3.46 15,000 2.48 7.70/8.20 CK5A/CK5BW030 24,200 TDR 13.30 11.55 23,600 3.46 15,000 2.48 7.70/8.20 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA030 24,200 TDR 13.50 11.70 23,400 3.34 14,900 2.42 7.50/8.00 CC5A/CD5AW030 24,200 TDR 13.50 11.70 23,400 3.34 14,900 2.42 7.50/8.00 CK3BA024 23,800 TDR 13.30 11.55 23,600 3.52 15,000 2.50 7.80/8.30 CK3BA030 24,400 TDR 13.50 11.80 23,600 3.50 14,900 2.52 7.80/8.30 CK5A/CK5BA024 23,800 TDR 13.30 11.55 23,600 3.52 15,000 2.50 7.80/8.30 CK5A/CK5BW024 23,800 TDR 13.30 11.55 23,600 3.52 15,000 2.50 7.80/8.30 CK5A/CK5BA030 24,400 TDR 13.50 11.80 23,600 3.50 14,900 2.52 7.80/8.30 CK5A/CK5BW030 24,400 TDR 13.50 11.80 23,600 3.50 14,900 2.52 7.80/8.30 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA030 24,200 TDR 13.50 11.65 23,400 3.34 14,900 2.42 7.50/8.00 CC5A/CD5AW030 24,200 TDR 13.50 11.65 23,400 3.34 14,900 2.42 7.50/8.00 FC4(B,C)NF036 28,600 TDR & TXV 12.30 10.70 29,600 3.26 18,400 2.28 7.70/8.00 CC5A/CD5AA030 28,000 NONE 12.30 10.65 29,000 3.12 18,200 2.24 7.50/7.80 CC5A/CD5AW030 28,000 NONE 12.30 10.65 29,000 3.12 18,200 2.24 7.50/7.80 CC5A/CD5AA036 29,000 NONE 12.50 10.95 29,400 3.30 18,300 2.32 7.70/8.20 CD5AW036 29,000 NONE 12.50 10.95 29,400 3.30 18,300 2.32 7.70/8.20 CE3AA030 28,200 NONE 12.50 10.70 29,200 3.24 18,300 2.28 7.70/8.00 CE3AA036 28,600 NONE 12.50 10.85 29,200 3.26 18,300 2.28 7.70/8.00 CF5AA036 28,800 NONE 12.50 10.90 29,400 3.28 18,300 2.30 7.70/8.00 CK3BA030 28,000 NONE 12.50 10.75 29,000 3.20 18,100 2.28 7.50/8.00 CK3BA036 29,200 NONE 12.50 10.95 29,600 3.36 18,400 2.34 7.70/8.20 CK5A/CK5BA030 28,000 NONE 12.50 10.75 29,000 3.20 18,100 2.28 7.50/8.00 CK5A/CK5BW030 28,000 NONE 12.50 10.75 29,000 3.20 18,100 2.28 7.50/8.00 CK5A/CK5BA036 29,200 NONE 12.50 10.95 29,600 3.36 18,400 2.34 7.70/8.20 CK5A/CK5BN036 29,200 NONE 12.50 10.95 29,600 3.36 18,400 2.34 7.70/8.20 CK5A/CK5BT036 29,200 NONE 12.50 10.95 29,600 3.36 18,400 2.34 7.70/8.20 CK5A/CK5BW036 29,200 NONE 12.50 10.95 29,600 3.36 18,400 2.34 7.70/8.20 F(A,B)4(A,B)N(F,C)030 28,200 TDR 12.50 10.80 29,200 3.26 18,200 2.30 7.70/8.00 F(A,B)4(A,B)N(F,C)036 28,600 TDR 12.30 10.70 29,600 3.26 18,400 2.28 7.70/8.00 FC4(B,C)NF030 28,200 TDR & TXV 12.50 10.80 29,200 3.26 18,200 2.30 7.70/8.00 FF1DNA030 28,400 TDR 12.30 10.70 29,400 3.28 18,400 2.30 7.70/8.00 FG3AAA036 28,400 NONE 12.50 10.75 29,200 3.24 18,300 2.28 7.70/8.00 FK4(C,D)NF001 29,000 TDR & TXV 13.70 11.75 28,800 3.40 17,900 2.40 8.00/8.50 FK4(C,D)NF002 29,200 TDR & TXV 13.70 11.80 29,000 3.52 18,000 2.44 8.20/8.70 FK4(C,D)NF003 29,600 TDR & TXV 14.20 12.25 28,600 3.52 17,700 2.48 8.20/8.70 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,200 TDR 13 11.45 28,400 3.14 17,500 2.3 7.5 CC5A/CD5AA036 29,000 TDR 13.7 11.8 27,000 3.36 17,600 2.38 8 CC5A/CD5AW030 28,200 TDR 13 11.45 28,400 3.14 17,500 2.3 7.5 CE3AA030 28,600 TDR 13.3 11.55 28,800 3.34 17,600 2.36 7.7 CE3AA036 28,600 TDR 13.5 11.6 28,600 3.32 17,700 2.36 7.7 CK3BA030 29,200 TDR 13.5 11.75 28,600 3.26 17,700 2.36 7.7 See notes on page 16.

COMBINATION RATINGS* Continued Seasonal Efficiency SEER ARI STANDARD RATINGS* Field-Supplied High-Temp Low-Temp Seasonal Factory- Accessory Efficiency Supplied HSPF/ UNIT SIZE- INDOOR Enhancement Rating TXV TDR** EER CAP COP CAP COP with LSV Standard TXV& HSPF SERIES UNIT TC CK3BA036 29,200 TDR 13.7 11.85 28,400 3.48 17,700 2.42 8 CK5A/CK5BA030 28,600 TDR 13 11.5 28,600 3.26 17,700 2.36 7.7 CK5A/CK5BA036 29,200 TDR 13.7 11.85 28,400 3.48 17,700 2.42 8 CK5A/CK5BT036 29,200 TDR 13.7 11.85 28,400 3.48 17,700 2.42 8 CK5A/CK5BW030 29,200 TDR 13.5 11.75 28,600 3.24 17,700 2.36 7.7 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,200 TDR 13.3 11.6 28,200 3.16 17,400 2.32 7.5 CC5A/CD5AA036 29,200 TDR 14 11.95 27,000 3.4 17,600 2.4 8 CC5A/CD5AW030 28,200 TDR 13.3 11.6 28,200 3.16 17,400 2.32 7.5 CC5A/CD5AW036 29,200 TDR 14 11.95 27,200 3.4 17,600 2.4 8 CE3AA030 28,600 TDR 13.5 11.7 28,600 3.36 17,600 2.38 7.7 CE3AA036 28,800 TDR 13.7 11.85 28,400 3.34 17,500 2.38 7.7 CK3BA030 28,400 TDR 13.3 11.55 28,600 3.26 17,600 2.38 7.7 CK3BA036 29,400 TDR 14 12 28,400 3.5 17,600 2.44 8 CK5A/CK5BA030 28,400 TDR 13.3 11.55 28,400 3.28 17,600 2.38 7.7 CK5A/CK5BA036 29,400 TDR 14 12 28,200 3.5 17,600 2.44 8 CK5A/CK5BW030 29,200 TDR 13.3 11.9 28,600 3.26 17,600 2.38 7.7 CK5A/CK5BW036 29,400 TDR 14 12 28,200 3.5 17,600 2.44 8 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.50 11.65 29,200 3.44 18,200 2.42 8.00/8.50 CD5AW036 29,600 TDR 13.50 11.65 29,200 3.44 18,200 2.42 8.00/8.50 CK3BA030 28,600 TDR 13.00 11.20 29,000 3.32 18,100 2.34 7.70/8.20 CK3BA036 29,600 TDR 13.50 11.65 29,200 3.48 18,000 2.42 8.00/8.50 CK5A/CK5BA030 28,600 TDR 13.00 11.20 29,000 3.32 18,100 2.34 7.70/8.20 CK5A/CK5BW030 28,600 TDR 13.00 11.20 29,000 3.32 18,100 2.34 7.70/8.20 CK5A/CK5BA036 29,600 TDR 13.50 11.65 29,200 3.48 18,000 2.42 8.00/8.50 CK5A/CK5BN036 29,600 TDR 13.50 11.65 29,200 3.48 18,000 2.42 8.00/8.50 CK5A/CK5BT036 29,600 TDR 13.50 11.65 29,200 3.48 18,000 2.42 8.00/8.50 CK5A/CK5BW036 29,600 TDR 13.50 11.65 29,200 3.48 18,000 2.42 8.00/8.50 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.50 11.65 29,200 3.44 18,200 2.42 8.00/8.50 CD5AW036 29,600 TDR 13.50 11.65 29,200 3.44 18,200 2.42 8.00/8.50 CK3BA030 28,800 TDR 13.00 11.20 29,000 3.32 18,100 2.34 7.70/8.20 CK3BA036 29,600 TDR 13.50 11.60 29,200 3.48 18,100 2.42 8.00/8.50 CK5A/CK5BA030 28,800 TDR 13.00 11.20 29,000 3.32 18,100 2.34 7.70/8.20 030-D, E CK5A/CK5BW030 28,800 TDR 13.00 11.20 29,000 3.32 18,100 2.34 7.70/8.20 CK5A/CK5BA036 29,600 TDR 13.50 11.60 29,200 3.48 18,100 2.42 8.00/8.50 CK5A/CK5BN036 29,600 TDR 13.50 11.60 29,200 3.48 18,100 2.42 8.00/8.50 CK5A/CK5BT036 29,600 TDR 13.50 11.60 29,200 3.48 18,100 2.42 8.00/8.50 CK5A/CK5BW036 29,600 TDR 13.50 11.60 29,200 3.48 18,100 2.42 8.00/8.50 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.70 11.85 29,000 3.48 18,100 2.44 8.00/8.50 CD5AW036 29,600 TDR 13.70 11.85 29,000 3.48 18,100 2.44 8.00/8.50 CK3BA030 28,800 TDR 13.00 11.30 29,000 3.32 18,000 2.36 7.70/8.20 CK3BA036 29,600 TDR 13.00 11.70 29,200 3.50 18,000 2.44 8.00/8.50 CK5A/CK5BA030 28,800 TDR 13.00 11.30 29,000 3.32 18,000 2.36 7.70/8.20 CK5A/CK5BW030 28,800 TDR 13.00 11.30 29,000 3.32 18,000 2.36 7.70/8.20 CK5A/CK5BA036 29,600 TDR 13.00 11.70 29,200 3.50 18,000 2.44 8.00/8.50 CK5A/CK5BN036 29,600 TDR 13.00 11.70 29,200 3.50 18,000 2.44 8.00/8.50 CK5A/CK5BT036 29,600 TDR 13.00 11.70 29,200 3.50 18,000 2.44 8.00/8.50 CK5A/CK5BW036 29,600 TDR 13.00 11.70 29,200 3.50 18,000 2.44 8.00/8.50 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.70 11.85 29,000 3.48 18,100 2.44 8.00/8.50 CD5AW036 29,600 TDR 13.70 11.85 29,000 3.48 18,100 2.44 8.00/8.50 CK3BA030 29,000 TDR 13.50 11.55 28,800 3.38 17,900 2.38 7.70/8.20 CK3BA036 29,800 TDR 14.00 11.95 29,000 3.54 17,900 2.46 8.00/8.50 CK5A/CK5BA030 29,000 TDR 13.50 11.55 28,800 3.38 17,900 2.38 7.70/8.20 CK5A/CK5BW030 29,000 TDR 13.50 11.55 28,800 3.38 17,900 2.38 7.70/8.20 CK5A/CK5BA036 29,800 TDR 14.00 11.95 29,000 3.54 17,900 2.46 8.00/8.50 CK5A/CK5BN036 29,800 TDR 14.00 11.95 29,000 3.54 17,900 2.46 8.00/8.50 CK5A/CK5BT036 29,800 TDR 14.00 11.95 29,000 3.54 17,900 2.46 8.00/8.50 CK5A/CK5BW036 29,800 TDR 14.00 11.95 29,000 3.54 17,900 2.46 8.00/8.50 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK3BA030 28,800 TDR 13.00 11.50 28,800 3.36 17,900 2.38 7.70/8.20 CK3BA036 29,600 TDR 14.00 11.90 29,000 3.52 17,900 2.46 8.00/8.50 CK5A/CK5BA030 28,800 TDR 13.00 11.50 28,800 3.36 17,900 2.38 7.70/8.20 CK5A/CK5BW030 28,800 TDR 13.00 11.50 28,800 3.36 17,900 2.38 7.70/8.20 CK5A/CK5BA036 29,800 TDR 14.00 11.90 29,000 3.52 17,900 2.46 8.00/8.50 CK5A/CK5BN036 29,600 TDR 14.00 11.90 29,000 3.52 17,900 2.46 8.00/8.50 CK5A/CK5BT036 29,800 TDR 14.00 11.90 29,000 3.52 17,900 2.46 8.00/8.50 CK5A/CK5BW036 29,600 TDR 14.00 11.90 29,000 3.52 17,900 2.46 8.00/8.50 See notes on page 15. 10

UNIT SIZE- SERIES INDOOR UNIT TC COMBINATION RATINGS* Continued Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Field-Supplied Accessory TXV ARI STANDARD RATINGS* High-Temp Low-Temp TXV& TDR** EER CAP COP CAP COP Seasonal Efficiency HSPF/ HSPF with LSV FC4(B,C)N(F,B)042 34,200 TDR & TXV 12.00 10.20 36,000 3.34 22,800 2.42 7.80/8.20 CC5A/CD5AA036 34,000 None 12.00 10.25 36,000 3.32 22,600 2.42 7.70/8.20 CD5AW036 34,000 None 12.00 10.25 36,000 3.32 22,600 2.42 7.70/8.20 CC5A/CD5AA042 34,000 None 12.00 10.25 36,000 3.32 22,600 2.42 7.70/8.20 CC5A/CD5AW042 33,800 None 12.00 10.20 36,000 3.28 22,600 2.40 7.70/8.20 CE3AA036 33,600 None 11.70 10.15 36,000 3.26 22,600 2.38 7.60/8.20 CE3AA042 34,400 None 12.00 10.30 36,000 3.36 22,600 2.44 7.70/8.20 CF5AA036 34,000 None 12.00 10.25 36,000 3.30 22,600 2.40 7.70/8.20 CK3BA036 33,600 None 12.00 10.35 36,000 3.36 22,800 2.44 7.80 CK3BA042 34,200 None 12.00 10.25 36,000 3.36 22,800 2.44 7.80 CK5A/CK5BA036 33,600 None 12.00 10.35 36,000 3.32 22,400 2.42 7.70 CK5A/CK5BA042 34,200 None 12.00 10.25 36,000 3.36 22,800 2.44 7.80 CK5A/CK5BN042 33,600 None 12.00 10.25 36,000 3.32 22,400 2.42 7.70 CK5A/CK5BW036 34,200 None 12.00 10.35 36,000 3.32 22,400 2.42 7.70 F(A,B)4(A,B)NF036 33,600 TDR 11.50 9.95 36,000 3.24 22,800 2.36 7.60/8.00 F(A,B)4(A,B)N(F,B)042 34,200 TDR 12.00 10.20 36,000 3.34 22,800 2.42 7.80/8.20 FC4(B,C)NF036 33,600 TDR & TXV 11.50 9.95 36,000 3.24 22,800 2.36 7.60/8.00 FC4(B,C)NF033 34,200 TDR & TXV 11.70 10.15 36,000 3.34 22,800 2.42 7.80/8.20 FG3AAA036 33,400 None 11.50 10.10 36,000 3.24 22,600 2.38 7.60/8.00 FK4(C,D)NF001 33,600 TDR & TXV 12.50 10.70 35,400 3.32 22,000 2.46 7.80/8.20 FK4(C,D)NF002 33,600 TDR & TXV 12.50 10.70 35,800 3.44 22,200 2.50 8.00/8.50 FK4(C,D)NF003 34,400 TDR & TXV 13.00 11.25 35,200 3.46 21,800 2.54 8.00/8.50 FK4(C,D)NF004 34,600 TDR & TXV 12.50 10.85 36,000 3.64 22,400 2.58 8.20/9.00 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,000 TDR 12.5 10.95 35,200 3.32 21,800 2.46 7.8 CE3AA036 32,600 TDR 13 10.55 35,000 3.26 21,800 2.44 7.5 CE3AA042 34,600 TDR 13 11.15 35,400 3.38 21,800 2.48 7.5 CK3BA036 34,000 TDR 12.5 10.95 35,400 3.4 22,000 2.5 7.5 CK5A/CK5BA036 34,800 TDR 13 11.2 35,400 3.4 22,000 2.5 7.5 CK5A/CK5BE042 34,000 TDR 13 11.05 35,400 3.46 22,000 2.52 8 CK5A/CK5BT036 34,000 TDR 12.5 10.95 35,400 3.4 22,000 2.5 7.5 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA036 33,600 TDR 13.5 10.9 35,000 3.36 21,800 2.48 7.5 CC5A/CD5AA042 34,000 TDR 12.5 10.85 35,000 3.38 21,600 2.5 7.5 CC5A/CD5AW036 34,000 TDR 13 11.15 35,000 3.36 21,800 2.48 7.5 CE3AA036 33,000 TDR 13 10.75 35,000 3.3 21,800 2.46 7.5 036-E, F CE3AA042 34,600 TDR 13 11.35 35,200 3.42 21,800 2.52 8 CK3BA036 35,000 TDR 13 11.4 35,200 3.44 21,800 2.52 8 CK3BA042 35,000 TDR 13 11.5 35,200 3.44 21,800 2.54 8 CK5A/CK5BA036 35,000 TDR 13 11.4 35,200 3.44 21,800 2.52 8 CK5A/CK5BA042 35,000 TDR 13 11.5 35,200 3.44 21,800 2.54 8 CK5A/CK5BE042 35,200 TDR 13 11.55 35,400 3.5 21,800 2.56 8 CK5A/CK5BT036 35,000 TDR 13 11.4 35,200 3.44 21,800 2.52 8 CK5A/CK5BT042 35,000 TDR 13 11.5 35,200 3.44 21,800 2.54 8 CK5A/CK5BW036 35,000 TDR 13 11.4 35,200 3.44 21,800 2.52 8 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,000 TDR 13 11.2 35,000 3.36 21,800 2.5 7.5 CC5A/CD5AA042 33,600 TDR 13 11.1 35,000 3.4 21,600 2.52 7.5 CC5A/CD5AW036 34,000 TDR 13 11.2 35,000 3.36 21,800 2.5 7.5 CC5A/CD5AW042 34,000 TDR 13 11.25 34,800 3.38 21,600 2.5 7.5 CE3AA036 33,200 TDR 13 10.85 35,000 3.3 21,600 2.48 7.5 CE3AA042 34,600 TDR 13 11.45 35,200 3.44 21,600 2.52 8 CK3BA036 35,000 TDR 13 11.5 35,200 3.44 21,800 2.54 8 CK3BA042 34,200 TDR 13 11.3 35,200 3.46 21,800 2.54 8 CK5A/CK5BA036 35,000 TDR 13 11.5 35,200 3.44 21,800 2.54 8 CK5A/CK5BA042 34,200 TDR 13 11.3 35,200 3.46 21,800 2.54 8 CK5A/CK5BT036 35,000 TDR 13 11.5 35,200 3.44 21,800 2.54 8 CK5A/CK5BT042 34,200 TDR 13 11.3 35,200 3.46 21,800 2.54 8 CK5A/CK5BW036 35,000 TDR 13 11.5 35,200 3.44 21,800 2.54 8 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13 11.4 35,000 3.38 21,600 2.5 7.5 CC5A/CD5AW036 34,000 TDR 13 11.1 35,000 3.36 21,800 2.48 7.5 CC5A/CD5AW042 34,000 TDR 13 11.2 34,800 3.36 21,600 2.48 7.5 CE3AA036 33,800 TDR 13 11 35,000 3.3 21,800 2.48 7.5 CE3AA042 34,600 TDR 13 11.4 35,200 3.44 21,800 2.52 8 CK3BA042 34,000 TDR 13 11.25 35,200 3.44 21,800 2.54 8 CK5A/CK5BA042 34,000 TDR 13 11.25 35,200 3.44 21,800 2.54 8 CK5A/CK5BT042 34,000 TDR 13 11.25 35,200 3.44 21,800 2.54 8 CK5A/CK5BW036 34,000 TDR 13 11.15 35,200 3.44 21,800 2.54 8 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,200 TDR 13 11.4 34,800 3.4 21,600 2.52 7.5 CC5A/CD5AW036 33,600 TDR 13 10.95 35,000 3.36 21,600 2.5 7.5 CC5A/CD5AW042 34,000 TDR 13 11.3 34,800 3.38 21,600 2.5 7.5 See notes on page 16. 11

UNIT SIZE- SERIES 036-E, F 042-E, F INDOOR UNIT TC COMBINATION RATINGS* Continued Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Field-Supplied Accessory TXV ARI STANDARD RATINGS* High-Temp Low-Temp TXV& TDR** EER CAP COP CAP COP Seasonal Efficiency HSPF/ HSPF with LSV CE3AA036 33,200 TDR 13 10.85 35,000 3.3 21,600 2.48 7.5 CE3AA042 34,600 TDR 13 11.45 35,000 3.44 21,600 2.54 8 CK3BA042 34,200 TDR 13 11.3 35,200 3.46 21,600 2.54 8 CK5A/CK5BA042 34,200 TDR 13 11.3 35,200 3.46 21,800 2.56 8 CK5A/CK5BT042 34,200 TDR 13 11.3 35,200 3.46 21,800 2.56 8 CK5A/CK5BW036 34,000 TDR 13 11.2 35,200 3.44 21,800 2.54 8 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.50 10.65 36,000 3.40 22,400 2.46 7.80/ CK5AA036 34,400 TDR 12.00 10.50 36,000 3.40 22,600 2.46 7.80 CK5AN042 34,400 TDR 12.50 10.65 36,000 3.44 22,400 2.48 8.00 CK3BA036 34,400 TDR 12.00 10.50 36,000 3.40 22,600 2.46 7.80 CK3BA042 34,400 TDR 12.50 10.65 36,000 3.44 22,400 2.48 8.00 CK5A/CK5BA042 34,400 TDR 12.50 10.65 36,000 3.44 22,400 2.48 8.00 CK5A/CK5BW036 34,400 TDR 12.00 10.50 36,000 3.40 22,600 2.46 7.80 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.50 10.65 36,000 3.40 22,400 2.46 7.80/ CK3BA036 34,400 TDR 12.00 10.55 36,000 3.40 22,400 2.46 7.80 CK3BA042 34,400 TDR 12.50 10.65 36,000 3.44 22,400 2.48 8.00 CK5A/CK5BA036 34,400 TDR 12.00 10.55 36,000 3.40 22,400 2.46 7.80 CK5A/CK5BN042 34,400 TDR 12.50 10.65 36,000 3.44 22,400 2.48 8.00 CK5AA042 34,400 TDR 12.50 10.65 36,000 3.44 22,400 2.48 8.00 CK5AW036 34,400 TDR 12.00 10.55 36,000 3.40 22,400 2.46 7.80 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.70 10.85 35,800 3.44 22,200 2.50 7.80/ CK3BA036 34,400 TDR 12.50 10.60 36,000 3.42 22,400 2.48 8.00 CK3BA042 34,600 TDR 12.50 10.80 36,000 3.46 22,200 2.50 8.00 CK5AA036 34,400 TDR 12.50 10.60 36,000 3.42 22,400 2.48 8.00 CK5AN042 34,600 TDR 12.50 10.80 36,000 3.46 22,200 2.50 8.00 CK5A/CK5BA042 34,600 TDR 12.50 10.80 36,000 3.46 22,200 2.50 8.00 CK5A/CK5BW036 34,400 TDR 12.50 10.60 36,000 3.42 22,400 2.48 8.00 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.70 10.90 35,800 3.44 22,200 2.50 7.80/ CK3BA036 34,600 TDR 12.50 10.85 36,000 3.48 22,200 2.50 8.00 CK3BA042 34,600 TDR 12.80 11.00 35,800 3.50 22,200 2.54 8.00 CK5AA036 34,600 TDR 12.50 10.85 36,000 3.48 22,200 2.50 8.00 CK5AN042 34,600 TDR 12.80 11.00 35,800 3.50 22,200 2.54 8.00 CK5A/CK5BA042 34,600 TDR 12.80 11.00 35,800 3.50 22,200 2.54 8.00 CK5A/CK5BW036 34,600 TDR 12.50 10.85 36,000 3.48 22,200 2.50 8.00 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK3BA036 34,600 TDR 12.50 10.85 35,800 3.48 22,200 2.52 8.00 CK3BA042 34,600 TDR 12.80 11.00 35,800 3.50 22,200 2.54 8.00 CK5AA036 34,600 TDR 12.50 10.85 35,800 3.48 22,200 2.52 8.00 CK5AN042 34,600 TDR 12.80 11.00 35,800 3.50 22,200 2.54 8.00 CK5A/CK5BA042 34,600 TDR 12.80 11.00 35,800 3.50 22,200 2.54 8.00 CK5A/CK5BW036 34,600 TDR 12.50 10.85 35,800 3.48 22,200 2.52 8.00 FK4(C,D)NF005 41,000 TDR & TXV 14.00 12.10 41,000 3.72 24,800 2.66 8.20/8.40 CC5A/CD5AA042 39,000 None 12.00 10.75 41,000 3.32 25,400 2.40 7.50/7.70 CC5A/CD5AW042 38,500 None 12.00 10.70 41,000 3.28 25,400 2.38 7.40/7.60 CD5AA048 39,000 None 12.50 10.80 41,000 3.36 25,400 2.42 7.50/7.70 CC5A/CD5AC048 38,500 None 12.50 10.70 41,000 3.22 25,400 2.38 7.30/7.50 CC5A/CD5AW048 39,000 None 12.50 10.80 41,000 3.36 25,400 2.42 7.50/7.70 CE3AA042 39,500 None 12.00 10.85 41,000 3.36 25,400 2.42 7.50/7.70 CE3AA048 39,500 None 12.50 10.85 41,000 3.40 25,400 2.44 7.50/7.70 CF5AA048 39,500 None 12.50 10.85 41,000 3.34 25,400 2.42 7.50/7.50 CK3BA042 40,000 None 12.00 10.75 41,000 3.34 25,600 2.42 7.50 CK3BA048 40,000 None 12.00 10.80 41,000 3.40 25,600 2.44 7.50 CK5A/CK5BA042 40,000 None 12.00 10.75 41,000 3.34 25,600 2.42 7.50 CK5A/CK5BA048 40,000 None 12.00 10.80 41,000 3.40 25,600 2.44 7.50 CK5A/CK5BN042 40,000 None 12.00 10.75 41,000 3.34 25,600 2.42 7.50 CK5A/CK5BW048 40,000 None 12.00 10.80 41,000 3.40 25,600 2.44 7.50 F(A,B)4(A,B)N(F,B)042 39,000 TDR 12.00 10.65 41,000 3.32 25,600 2.40 7.50/7.70 F(A,B)4(A,B)N(F,B)048 39,500 TDR 12.50 10.80 41,000 3.46 25,600 2.46 7.70/7.90 FC4(B,C)NF038 40,500 TDR & TXV 12.50 11.00 41,000 3.56 25,800 2.50 7.80/8.00 FC4(B,C)N(F,B)042 39,000 TDR & TXV 12.00 10.65 41,000 3.32 25,600 2.40 7.50/7.70 FC4(B,C)N(F,B)048 39,500 TDR & TXV 12.50 10.80 41,000 3.46 25,600 2.46 7.70/7.90 FG3AAA048 39,000 None 12.00 10.80 41,000 3.38 25,400 2.44 7.50/7.70 FK4(C,D)NF003 39,500 TDR & TXV 13.50 11.60 40,000 3.42 24,800 2.52 7.80/8.00 FK4(C,D)NB005 41,500 TDR & TXV 13.50 11.65 41,000 3.74 25,400 2.62 8.20/8.40 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,500 TDR 13 11.05 41,000 3.42 25,400 2.48 7.5 CC5A/CD5AC048 39,000 TDR 13 11.05 41,000 3.32 25,200 2.44 7.5 CD5AA048 39,500 TDR 13 11.2 41,000 3.46 25,200 2.5 7.5 CE3AA042 39,500 TDR 13.5 11.1 41,500 3.48 25,400 2.5 7.5 See notes on page 16. 12

COMBINATION RATINGS* Continued Seasonal Efficiency SEER Field-Supplied Accessory ARI STANDARD RATINGS* High-Temp Low-Temp Seasonal Efficiency HSPF/ HSPF with LSV Factory- Supplied UNIT SIZE- INDOOR Enhancement Rating TXV TDR** EER Standard TXV& SERIES UNIT TC CAP COP CAP COP CE3AA048 40,000 TDR 13 11.2 41,500 3.52 25,400 2.52 7.7 CK3BA042 39,500 TDR 13 11.05 41,500 3.5 25,400 2.52 7.7 CK3BA048 41,000 TDR 13 11.55 41,500 3.56 25,400 2.54 8 CK5A/CK5BA042 39,500 TDR 13 11.05 42,000 3.52 25,400 2.52 7.7 CK5A/CK5BA048 39,500 TDR 13 11.15 41,500 3.56 25,400 2.54 8 CK5A/CK5BE042 40,500 TDR 13 11.4 41,500 3.56 25,400 2.52 7.7 CK5A/CK5BT042 40,500 TDR 13 11.4 41,500 3.5 25,400 2.52 7.7 CK5A/CK5BT048 41,000 TDR 13.5 11.5 41,500 3.56 25,400 2.54 8 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,500 TDR 13 11.2 41,000 3.44 25,200 2.48 7.5 CC5A/CD5AC048 39,500 TDR 13 11.2 40,500 3.34 25,000 2.46 7.5 CC5A/CD5AW042 40,000 TDR 13 11.35 41,000 3.38 25,200 2.46 7.5 CC5A/CD5AW048 39,500 TDR 13 11.3 41,000 3.5 25,200 2.52 7.7 CD5AA048 39,500 TDR 13 11.3 41,000 3.5 25,200 2.52 7.7 CE3AA042 41,000 TDR 13.5 11.55 41,000 3.5 25,200 2.52 7.7 CE3AA048 41,000 TDR 13.5 11.6 41,500 3.54 25,400 2.54 7.7 CK3BA042 39,500 TDR 13 11.15 41,500 3.54 25,400 2.54 7.7 CK3BA048 39,500 TDR 13 11.3 41,500 3.6 25,400 2.56 8 CK5A/CK5BA042 39,500 TDR 13.5 11.15 41,500 3.54 25,400 2.54 7.7 CK5A/CK5BA048 39,500 TDR 13 11.3 41,500 3.6 25,400 2.56 8 CK5A/CK5BT042 39,500 TDR 13 11.15 41,500 3.54 25,400 2.54 7.7 CK5A/CK5BT048 41,000 TDR 13.5 11.65 41,500 3.6 25,400 2.56 8 CK5A/CK5BW048 40,000 TDR 13 11.35 41,500 3.6 25,400 2.56 8 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,500 TDR 13 11.2 41,000 3.44 25,200 2.48 7.5 CC5A/CD5AC048 39,500 TDR 13 11.25 40,500 3.34 25,000 2.46 7.5 CC5A/CD5AW042 39,500 TDR 13 11.1 41,000 3.38 25,200 2.46 7.5 CC5A/CD5AW048 40,500 TDR 13 11.6 41,000 3.5 25,000 2.52 7.7 CD5AA048 39,500 TDR 13 11.35 41,000 3.5 25,200 2.52 7.7 CE3AA042 41,000 TDR 13.5 11.55 41,000 3.5 25,200 2.52 7.7 CE3AA048 41,000 TDR 13.5 11.6 41,500 3.54 25,400 2.54 7.7 CK3BA042 39,500 TDR 13.5 11.2 41,500 3.54 25,400 2.54 7.7 CK3BA048 40,000 TDR 13.5 11.45 41,500 3.6 25,200 2.56 8 CK5A/CK5BA042 40,500 TDR 13.5 11.5 41,500 3.54 25,400 2.54 7.7 042-E, F CK5A/CK5BA048 41,000 TDR 13.5 11.65 41,500 3.6 25,200 2.56 8 CK5A/CK5BT042 39,500 TDR 13.5 11.25 41,500 3.54 25,400 2.54 7.7 CK5A/CK5BT048 39,500 TDR 13 11.35 41,500 3.6 25,200 2.56 8 CK5A/CK5BW048 39,500 TDR 13.5 11.3 41,500 3.6 25,200 2.56 8 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,500 TDR 13.5 11.25 41,000 3.44 25,200 2.5 7.5 CC5A/CD5AC048 39,500 TDR 13.5 11.35 40,500 3.34 25,000 2.48 7.5 CC5A/CD5AW042 39,500 TDR 13 11.15 41,000 3.38 25,200 2.46 7.5 CC5A/CD5AW048 39,500 TDR 13 11.35 41,000 3.5 25,000 2.52 7.7 CD5AA048 40,500 TDR 13.5 11.65 41,000 3.5 25,000 2.52 7.7 CE3AA042 41,000 TDR 13.5 11.6 41,000 3.52 25,200 2.52 7.7 CE3AA048 41,000 TDR 13.5 11.65 41,500 3.54 25,200 2.54 7.7 CK3BA042 40,500 TDR 13 11.5 41,500 3.54 25,200 2.54 7.7 CK3BA048 40,000 TDR 13 11.4 41,500 3.6 25,200 2.56 8 CK5A/CK5BA042 41,000 TDR 13.5 11.55 41,500 3.54 25,200 2.54 7.7 CK5A/CK5BA048 40,000 TDR 13.5 11.4 41,500 3.6 25,200 2.56 8 CK5A/CK5BT042 41,000 TDR 13.5 11.6 41,500 3.54 25,200 2.54 7.7 CK5A/CK5BT048 40,000 TDR 13.5 11.4 41,500 3.6 25,200 2.56 8 CK5A/CK5BW048 41,000 TDR 13.5 11.7 41,500 3.6 25,200 2.56 8 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CD5AA048 39,000 TDR 12.50 10.75 41,000 3.26 25,400 2.38 7.30/ CK3BA048 40,000 TDR 12.50 10.75 42,000 3.44 26,000 2.44 7.50 CK5AA048 40,000 TDR 12.50 10.75 42,000 3.44 26,000 2.44 7.50 CK5A/CK5BW048 40,000 TDR 12.50 10.75 42,000 3.44 26,000 2.44 7.50 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CD5AA048 39,000 TDR 12.50 10.80 41,000 3.26 25,400 2.40 7.30/ CK3BA048 40,000 TDR 12.50 10.85 42,000 3.46 25,800 2.46 7.50 CK5AA048 40,000 TDR 12.50 10.85 42,000 3.46 25,800 2.46 7.50 CK5AW048 40,000 TDR 12.50 10.85 42,000 3.46 25,800 2.46 7.50 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CD5AA048 39,000 TDR 13.00 11.05 41,000 3.32 25,200 2.42 7.50/ CK5AW048 40,500 TDR 12.50 11.00 42,500 3.50 25,800 2.48 7.50 CK5A/CK5BA048 40,500 TDR 12.50 11.00 42,000 3.50 25,800 2.48 7.50 CK3BA048 40,500 TDR 12.50 11.00 42,000 3.50 25,800 2.48 7.50 See notes on page 16. 13

UNIT SIZE- SERIES 042-E, F 048-D, F INDOOR UNIT TC COMBINATION RATINGS* Continued Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Field-Supplied Accessory TXV 14 ARI STANDARD RATINGS* High-Temp Low-Temp TXV& TDR** EER CAP COP CAP COP Seasonal Efficiency HSPF/ HSPF with LSV COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3AA042 40,000 TDR 12.50 10.75 42,000 3.40 25,800 2.44 7.50 CK5AA042 40,000 TDR 12.50 10.75 42,000 3.40 25,800 2.44 7.50 CK5AN042 40,000 TDR 12.50 10.75 42,000 3.40 25,800 2.44 7.50 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CD5AA048 39,500 TDR 13.00 11.15 41,000 3.34 25,000 2.44 7.50/ CK3BA042 40,000 TDR 12.50 11.00 41,000 3.46 25,600 2.46 7.50 CK3BA048 40,500 TDR 13.00 11.20 41,000 3.54 25,600 2.52 7.70 CK5AN042 40,000 TDR 12.50 11.00 41,000 3.46 25,600 2.46 7.50 CK5AW048 40,500 TDR 13.00 11.20 41,000 3.54 25,600 2.52 7.70 CK5A/CK5BA042 40,000 TDR 12.50 11.00 41,000 3.46 25,600 2.46 7.50 CK5A/CK5BA048 40,500 TDR 13.00 11.20 41,000 3.54 25,600 2.52 7.70 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK3BA042 40,000 TDR 13.00 11.10 41,000 3.46 25,600 2.48 7.50 CK3BA048 40,500 TDR 13.00 11.25 41,000 3.54 25,600 2.52 7.70 CK5AN042 40,000 TDR 13.00 11.10 41,000 3.46 25,600 2.48 7.50 CK5A/CK5BA042 40,000 TDR 13.00 11.10 41,000 3.46 25,600 2.48 7.50 CK5A/CK5BW048 40,500 TDR 13.00 11.25 41,000 3.54 25,600 2.52 7.70 FK4(C,D)NF005 47,500 TDR & TXV 12.50 10.75 49,500 3.52 31,400 2.68 8.60/8.80 CC5A/CD5AC048 44,500 NONE 11.10 9.75 49,500 3.18 31,800 2.46 8.00/8.20 CC5A/CD5AW048 44,500 NONE 11.10 9.75 49,500 3.18 31,800 2.46 8.00/8.20 CC5A/CD5AA060 45,000 NONE 11.20 9.80 49,500 3.14 31,600 2.44 7.70/7.09 CC5A/CD5AW060 46,000 NONE 11.50 10.00 50,000 3.34 31,800 2.54 8.20/8.40 CE3AA048 45,000 NONE 11.20 9.85 49,500 3.22 31,800 2.48 8.00/8.20 CE3AA060 46,000 NONE 11.50 10.10 50,000 3.34 31,800 2.54 8.20/8.40 CF5AA048 45,000 NONE 11.20 9.85 49,500 3.16 31,600 2.44 7.80/8.00 CK5A/CK5BA048 45,500 NONE 11.30 10.05 49,500 3.28 31,800 2.52 8.00/8.20 CK5A/CK5BN048 45,500 NONE 11.30 10.05 49,500 3.28 31,800 2.52 8.00/8.20 CK5A/CK5BT048 45,500 NONE 11.30 10.05 49,500 3.28 31,800 2.52 8.00/8.20 CK5A/CK5BW048 45,500 NONE 11.30 10.05 49,500 3.28 31,800 2.52 8.00/8.20 CK5A/CK5BA060 46,500 NONE 11.50 10.20 49,500 3.32 32,000 2.54 8.00/8.20 CK5A/CK5BN060 46,500 NONE 11.50 10.20 49,500 3.32 32,000 2.54 8.00/8.20 CK5A/CK5BT060 46,500 NONE 11.50 10.20 49,500 3.32 32,000 2.54 8.00/8.20 CK5A/CK5BX060 47,000 NONE 11.50 10.35 50,000 3.44 32,000 2.60 8.50/8.70 F(A,B)4(A,B)N(F,B,C)048 45,500 TDR 1.10 9.75 50,000 3.30 32,000 2.50 8.10/8.30 F(A,B)4(A,B)N(F,B,C)060 46,500 TDR 11.20 9.80 50,500 3.40 32,400 2.54 8.30/8.50 FB4(A,B)NB070 47,500 TDR 11.50 10.15 51,000 3.56 32,200 2.76 8.70/8.90 FC4(B,C)N(F,B)048 45,500 TDR & TXV 11.10 9.75 50,000 3.30 32,000 2.50 8.10/8.30 FC4(B,C)N(F,B)060 46,500 TDR & TXV 11.20 9.80 50,500 3.40 32,400 2.54 8.30/8.50 FC4(B,C)NB054 47,500 TDR & TXV 12.00 10.35 50,500 3.62 32,000 2.70 8.70/8.90 FC4(B,C)NB070 47,500 TDR & TXV 11.50 10.15 51,000 3.56 32,200 2.76 8.70/8.90 FG3AAA048 44,500 NONE 11.10 9.75 49,500 3.22 31,800 2.48 8.00/8.20 FG3AAA060 45,500 NONE 11.50 10.00 49,500 3.26 31,800 2.50 8.00/8.20 FK4(C,D)NB006 48,000 TDR & TXV 13.00 11.05 49,500 3.70 31,400 2.76 9.00/9.20 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AC048 44,000 TDR 11.5 10.05 48,500 3.12 31,200 2.46 8 CD5AA048 44,500 TDR 11.7 10.15 49,000 3.3 31,400 2.52 8 CE3AA048 45,000 TDR 11.7 10.15 49,500 3.34 31,600 2.54 8.5 CE3AA060 46,500 TDR 12 10.5 49,500 3.42 31,600 2.62 8.5 CK3BA048 45,000 TDR 11.7 10.15 49,500 3.4 31,600 2.58 8.5 CK5A/CK5BA048 46,500 TDR 11.7 10.45 49,500 3.4 31,600 2.58 8.5 CK5A/CK5BT048 45,000 TDR 11.7 10.15 49,500 3.4 31,600 2.58 8.5 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,000 TDR 12 10.4 48,500 3.26 31,000 2.54 8.2 CC5A/CD5AC048 44,500 TDR 12 10.25 48,500 3.14 31,000 2.5 8 CC5A/CD5AW048 45,000 TDR 12 10.35 49,000 3.32 31,000 2.54 8.2 CD5AA048 45,000 TDR 12 10.35 49,000 3.32 31,200 2.56 8.2 CE3AA048 45,500 TDR 12 10.35 49,500 3.38 31,200 2.58 8.5 CE3AA060 46,500 TDR 12.5 10.7 49,500 3.46 31,400 2.64 8.5 CK3BA048 45,000 TDR 12 10.35 49,500 3.42 31,400 2.6 8.5 CK3BA060 46,500 TDR 12.5 10.65 50,000 3.62 31,400 2.68 8.7 CK5A/CK5BA048 45,000 TDR 12 10.35 49,500 3.42 31,400 2.6 8.5 CK5A/CK5BA060 46,500 TDR 12.5 10.65 50,000 3.62 31,400 2.68 8.7 CK5A/CK5BT048 45,000 TDR 12 10.35 49,500 3.42 31,400 2.6 8.5 CK5A/CK5BT060 46,500 TDR 12.5 10.65 50,000 3.62 31,400 2.68 8.7 CK5A/CK5BW048 45,000 TDR 12 10.35 49,500 3.42 31,400 2.6 8.5 CK5A/CK5BX060 47,500 TDR 12.5 10.95 49,500 3.62 31,400 2.7 8.7 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,000 TDR 12 10.35 48,500 3.24 31,200 2.54 8 CC5A/CD5AC048 44,500 TDR 12 10.25 48,500 3.14 31,000 2.48 8 CC5A/CD5AW048 45,000 TDR 12 10.3 49,000 3.32 31,200 2.54 8.2 CC5A/CD5AW060 47,000 TDR 12.5 10.75 49,500 3.46 31,400 2.62 8.5 CD5AA048 45,000 TDR 12 10.3 49,000 3.32 31,200 2.56 8.2 CE3AA048 45,500 TDR 12 10.3 49,500 3.38 31,400 2.56 8.5 See notes on page 16.