FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

Similar documents
FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

WATER POWERED OSCILLATING MONITOR

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

mechanical. OPERATION Rapidrop Global

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Design Criteria. Installation

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

TITAN FLOW CONTROL, INC.

The Series LFII (TY3596) Residential

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Model/Sprinkler Identification Numbers

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

TECHNICAL DATA OBSOLETE

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

INSTRUCTION MANUAL HS-229G

Inline Heater for Solvent or Gas. Installation and Operation Manual

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Technical Data. Installation

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

NATURAL GAS MODELS: SGC-36N/SGC-48N/SGC-60N/SGC-72N SGR-24N/SGR-36N BARBECUE - CARE AND USE

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

INSTALLATION AND OPERATION INSTRUCTIONS

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Incinerator Model A1600 -Oil

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

Operation, Maintenance and Installation Manual

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

UFM-T100H US ES CA Power Alarm Test TM

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

RK-02 Multi Point Detector Operator s Manual

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Karbon Kitchen Sink Tap

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

INSTALLATION, OPERATION AND MAINTENANCE

INFRARED RADIANT HEATERS

INSTALLATION AND OPERATING MANUAL

Foam Products ENGLISH

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

3 963/963E Benchtop Air Ionizer Instructions

55-Gallon Dispenser Package

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

FOR EASY, FAST INSTALLATION AND FOR RESULTS

User s Manual and Operating Instructions

Model 7656WCC Eye/face Wash

TrueClean ToteCleaner

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

TA-300, TA-300-LF, TA-350, TA-350-LF

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

RP, GP, XP Pro Series Installation Instructions

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

Foam Systems U.S. Quick Reference Guide

RK/ RK Oxygen Detector Operator s Manual

B.I.C.A Built-In Coffee Appliance

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

User s Manual and Operating Instructions

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

e Bath Fan with Light User s Guide

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Model /8320CRP Shower and Eye/Face Wash

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

AeroVent 3X Product Manual

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

RK/ RK Carbon Monoxide Detector Operator s Manual

HDS-1000W Hot Dog Steamer

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

Models: FM FM WARNING

Please Read And Save These Instructions.

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

e Bath Fan with Light User s Guide

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

Transcription:

MODEL - FCA & FCA-S TECHNICAL DATA MODELS FCA-65, FCA-80 & FCA-100 Carbon Steel Construction FCA-S 65, FCA-S 80 & FCA-S 100 Stainless Steel Construction INLET SIZE 65, 80, 100 NB WORKING Min 2.8 Kg/cm 2 (40 PSI) PRESSURE Max 7 Kg/cm 2 (100 PSI) FLANGE ANSI B16.5 Class 150# CONNECTION WEIGHT 65 NB - 34.5 Kg (Approx) 80 NB - 49.5 Kg 100 NB - 72.0 Kg VAPOUR SEAL 0.7 to 1.75 Kg/sq.cm. RUPTURE PRESSURE (10 PSI to 25 PSI) Running water/ water foam solution pressure at inlet of Foam Chamber MAXIMUM 0.07 Kg/sq.cm. (1.0 PSI) PERMISIBLE BACK PRESSURE ON VAPOUR SEAL VAPOUR SEAL Glass Deflector Solid or Split Deflector FINISH Red RAL 3000 APPROVAL UL Listed ORDERING a) Model & Size INFORMATION b) Flow & Pressure at inlet of each Foam Chamber c) Inlet, outlet flange specification d) Type of Deflector e) Foam concentrate used f) Tank number / Tag number FEATURES LISTED 4UT3 UL Listed Heavy duty welded construction with choice of Carbon Steel or Stainless Steel material Frangible Glass Vapour Seal Controlled Air Flow proportional to liquid flow for optimum foam quality and rupture of vapour seal in narrow pressure tolerances for increased reliability Field replaceable orifice plate fitted with Foam Chamber Interchangeable with HD Foam Chamber Model FC APPLICATION Foam Chamber is used in one of the most common application to protect vertical fixed roof (cone) liquid storage tanks, with or without internal floating roof with the low expansion foam system. The application of foam is on the basis that the risk comprises the total surface area of the fuel. The foam system design guidelines generally used are in accordance with NFPA-11, standard. Foam chambers are defined by NFPA-11 as Type II discharge outlets for delivering the foam to the surface of a flammable liquid. The Foam Chambers are widely used with the Inline Foam Inductor, Balance Pressure Foam Proportioning system, Bladder Tank Proportioner or Foam Tender. JUNE, 2014 PAGE 1 OF 6

SPECIFICATION Foam Chamber is an air aspirating foam discharge device, covering wide range of flow from 150 to 2400 litres per minute at 2.8 to 7 kg/sq.cm. inlet pressure. The Foam Chamber contains a vapour seal to prevent the entry of vapour into the foam chamber and the foam solution pipe. Each foam chamber is supplied with an orifice plate, designed for the required flow and inlet pressure. The orifice is field replaceable in the event of change in design parameters. The foam is produced by introducing air into the foam solution stream. The inlet of foam chamber is designed to create venturi jet which draws air into the foam solution stream. The air is drawn into the foam solution through the holes located on the foam chamber covered with stainless steel screen to exclude nesting birds and insects. The aerated foam is directed into the deflector for the gentle application of the expanded foam. The deflectors are available in different models. On removal of cover plate from the top of the chamber allows the system to be tested and to draw a sample of the expanded foam, without removing the vapour seal or disconnecting the foam chamber from the tank. Frangible glass bursting disc (vapour seal) can be replaced by easily. The vapour seal is designed to rupture within 0.7 to 1.75 Kg/sq.cm. (10 to 25 PSI) pressure at inlet flange of Foam Chamber, as required by NFPA, UL & FM standard. The vapour seal will withstand maximum back pressure of 0.07 Kg/sq.cm. Bar (1.0 PSI) or equal to 686mm of water column as specified by API for welded storage tank. If the requirement exceeds 0.07 Kg/sq.cm. Bar (1.0 PSI) as in case of nitrogen blanketing system, then this equipment may not be suitable. The vapour seal is frangible glass. The vapour seal is supplied with holder and for spares it can be with or without holder. The O ring used for seal are Nitride rubber and optional Viton for polar solvent. SYSTEM DESIGN REQUIREMENT The NFPA-11, a standard for low expansion foam, provides the essential requirement of an appropriate designed foam pouring system, which are identified and outlined as below: The Foam Deflector is used with the Foam Chamber. The aerated foam from the Foam Chamber is directed in to the deflector for the gentle application of the expanded foam. The deflector reduces the expanded foam velocity and allows the foam to slide down the tank wall. (a) Number of Foam Chamber: The number of foam chambers required is determined by the tank diameter. Where two or more foam chambers are required, they shall be spaced equally around the tank periphery and each Foam Chamber shall be sized to deliver foam at an approximately same rate. Please refer graph to select the unit that will provide the required minimum foam solution application rate at the available operating pressure of the Foam Chamber. For minimum number of Foam Chamber requirement, kindly follow the recommendations as per NFPA/OISD/TAC or as per the governmental codes or ordinances wherever applicable. (b) Minimum Foam Solution Application Rate: The minimum foam solution application rate is the rate at which the water and foam concentrate in correctly proportioned ratio should be delivered to the surface of a storage tank under protection to control and extinguish the fire. For minimum application rate requirement, follow the recommendations as per NFPA/OISD/ TAC or governmental codes or ordinances wherever applicable. JUNE, 2014 PAGE 2 OF 6

TESTING & MAINTENANCE Qualified and trained person must commission the system. After few initial successful tests, an authorized person must be trained to perform inspection and testing of the system. It is recommended to carry out physical inspection of the system regularly. The system must be fully tested at least once in a year or in accordance with applicable NFPA/OISD/TAC standards or in accordance with standards of the organization having local jurisdiction. Do not turn off the system or any valve to make repair or test the system, without placing a roving Fire Patrol in the area covered by the system. The Patrol should continue until the system is put back in service. Also inform the local security guard and control alarm station, so as to avoid false alarm. Each system is to be flushed properly. The vapour seal must be replaced if the system has been operated. Normal testing of the chamber can be carried out by removing the cover plate from the top of the chamber. This allows the system to draw a sample of the expanded foam without removing the vapour seal or disconnecting the Foam Chamber from the tank. The air screen is to be inspected periodically for the obstruction of air inlet holes. If any obstruction is noticed, remove the same and flush if necessary. It is recommended to have regular maintenance programme to inspect the Vapour Seal Chamber discharge area and deflector for possible deposit or obstruction. CAUTION Do not install Foam chambers on pressured storage tanks (Inert gas blanketed tanks) and storage tanks containing product which attack the foam chamber standard construction material. Maximum permissible back pressure on vapour seal is 0.07 Kg/sq.cm.2 (1.0 PSI) 1. A PROVISION IS TO BE MADE FOR PRESSURE GAUGE MOUNTING AT INLET OF, WHICH MAY BE PLUGGED AFTER SUCCESSFUL COMMISSIONING OF THE SYSTEM. THIS WILL HELP TO ANALYSE THE SYSTEM WHILE COMMISSIONING. 2. REFER TO THE INDIVIDUAL FOAM LISTING FOR OPERATING LIMITATION WITH EACH FOAM CONCENTRATE AND FOAM CHAMBER. Selection of HD Foam Chamber: SIZE K - FACTOR 65 NB 89.6 TO 207.8 80 NB 179.2 TO 385.9 100 NB 358.5 TO 907.2 To select the size of the Foam Chamber use the following formula: Q = K P Q = Total solution flow in litres per minute. K = Constant for Foam Chamber P = Inlet pressure in kg/sq.cm. JUNE, 2014 PAGE 3 OF 6

C 6 5 9 F2 8 7 B A 4 3 2 1 F1 DIMENSIONS OF in millimeter (Approximate) PART LIST INLET OUTLET SIZE SIZE A B C F1 F2 65NB 100NB 756 600 175 80NB 150NB 1093 908 225 100NB 200NB 1221 996 275 ITEM MATERIAL SPECIFICATON DESCRIPTION NO. FCA FCA-S 1 ORIFICE ASSEMBLY STAINLESS STEEL STAINLESS STEEL 2 INLET FLANGE STEEL STAINLESS STEEL 3 STRAINER ASSEMBLY STAINLESS STEEL STAINLESS STEEL 4 FOAM MAKING CHAMBER STEEL PIPE SS PIPE 5 STEEL STAINLESS STEEL 6 INSPECTION COVER STEEL STAINLESS STEEL 7 DISCHARGE PIPE STEEL PIPE SS PIPE 8 OUTLET FLANGE STEEL STAINLESS STEEL 9 VAPOUR SEAL ASSEMBLY GLASS GLASS 1. Pipes used are ERW (Seamless Pipe are optional) 2. Foam chambers are open to atmosphere & do not have internal shutoff device,hence no hydrotest is offered during inspection. JUNE, 2014 PAGE 4 OF 6

TYPICAL INSTALLATION WITH DEFLECTOR TYPICAL INSTALLATION OF WITH STUD FLANGED SPLIT DEFLECTOR OUTLET FLANGE GASKETS MODEL FCA TANK SHELL SPLIT DEFLECTOR MODEL SD MOUNTING PAD ASSEMBLY SPLIT DEFLECTOR INLET FLANGE STUD MOUNTING PAD STORAGE TANK Stud Mounting Pad with gasket & split deflector are optional items. To be ordered separately. TANK CUTOUT FOR MOUNTING OF SPLIT DEFLECTOR PCD FLANGE OUTLINE RØ TYPE SIZE INLET FLANGE SIZE OUTLET FLANGE SIZE RØ PCD CUTOUT SIZE HOLE Ø d NO OF HOLES FCA 65 65 100 114 191 19 4 FCA 80 80 150 168 241 22 4 Ø'd' FCA 100 100 200 219 298 22 8 BY INSTALLER TYPICAL INSTALLATION OF WITH STUD FLANGED TANK NOZZLE AND SOLID DEFLECTOR MODEL FCA 200 TANK NOZZLE (BY OTHERS) SOLID DEFLECTOR MODEL FD 150 150 STORAGE TANK GLASS VAPOUR SEAL WITH HOLDER (STANDARD SUPPLY) 1. Above dimensions are general guidelines only. The system designer can adopt the dimensions as per NFPA/TAC/OISD or as per the governing rules & ordinance having local jurdiction. 2. Tank Nozzle nutbolts & gasket are optional to be ordered separately. 3. Split deflector Model SD and solid deflector Model FD is standard supply in carbon steel material and optional in stainless steel. BY INSTALLER JUNE, 2014 PAGE 5 OF 6

PRESSURE VS FLOW PERFORMANCE CHARACTERISTIC 600 1000 FOAM SOLUTION FLOW FLOW IN LPM 500 400 300 200 FOAM SOLUTION FLOW FLOW IN LPM 800 600 400 100 2 3 4 5 6 INLET PRESSURE (KG/SQ.CM) FCA & FCA-S 65 NB 7 200 2 3 4 5 6 7 INLET PRESSURE (KG/SQ.CM) FCA & FCA-S 80 NB 2600 2400 2200 2000 1800 FOAM SOLUTION FLOW FLOW IN LPM 1600 1400 1200 1000 800 600 2 3 4 5 6 7 INLET PRESSURE (KG/SQ.CM) FCA & FCA-S 100 NB LIMITED WARRANTY HD FIRE PROTECT PVT. LTD. hereby referred to as HD FIRE warrants to the original purchaser of the fire protection products manufactured by HD FIRE and to any other person to whom such equipment is transferred, that such products will be free from defect in material and workmanship under normal use and care, for two (2) years from the date of shipment by HD FIRE. Products or Components supplied or used by HD FIRE, but manufactured by others, are warranted only to the extent of the manufacturer s warranty. No warranty is given for product or components which have been subject to misuse, improper installation, corrosion, unauthorized repair, alteration or un-maintained. HD FIRE shall not be responsible for system design errors or improper installation or inaccurate or incomplete information supplied by buyer or buyer s representatives. HD FIRE will repair or replace defective material free of charge, which is returned to our factory, transportation charge prepaid, provided after our inspection the material is found to have been defective at the time of initial shipment from our works. HD FIRE shall not be liable for any incidental or consequential loss, damage or expense arising directly or indirectly from the use of the product including damages for injury to person, damages to property and penalties resulting from any products and components manufactured by HD FIRE. HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product. HD FIRE shall not be liable for any damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fire s product liability exceed an amount equal to the sale price. The foregoing warranty is exclusive and in lieu of all other warranties and representation whether expressed, implied, oral or written, including but not limited to, any implied warranties or merchantability or fitness for a particular purpose. All such other warranties and representations are hereby cancelled. NOTICE : The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the provision of government codes or ordinances wherever applicable. The information provided by us are to the best of our knowledge and belief, and are general guidelines only. Site handling and installation control is beyond our reach. Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or damages due to our product. Product development is a continuous programme of HD FIRE PROTECT PVT. LTD. and hence the right to modify any specification without prior notice is reserved with the company. HD FIRE PROTECT PVT. LTD. Protecting What Matters Most to You C-3/6, THE NANDANVAN IND. ESTATE, L.B.S. MARG, THANE 400 604., INDIA. PHONES : + (91) 22 2583 5434 2582 6958 2582 6793 FAX : +(91) 22 2581 2524 6796 9049 EMAIL : info@hdfire.com WEBSITE : www.hdfire.com JUNE, 2014 PAGE 6 OF 6