Measurement Devices. Topic 5 - Audio 56

Similar documents
Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc.

Guide for Radon Measurements in Residential Dwellings (Homes)

Policy Manual. April 21,2015. National Radon Proficiency Program 2015

CHAPTER 240. RADON CERTIFICATION

Certificate of Completion

Certificate of Completion

Comprehensive Short-Term Radon Survey Report

Radon Testing Results. City Hall

Certificate of Completion

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Radon Detection Specialists, Inc. Love the Lungs You re With

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Quality Assurance Plan for Conducting Radon Measurements

Testing for Elevated Radon in Oregon Schools

Testing for Elevated Radon in Oregon Schools Protocol and Plan

2.3 Definitions, General Provisions, and Radon Standards

their original bags during the test period determine what background reading they might accumulate. The actual

Bethel School District Radon Testing Plan

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

Consumer s Guide To Radon Reduction

RULES AND REGULATIONS FOR RADON CONTROL

Radiation Monitoring Equipment


NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

Portable Survey Instruments NISP-RP-01

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

RADON LAZERWEB SERVICES

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Testing for Elevated Radon in Oregon Schools

ALL RADON TESTS WERE SIGNIFICANLY BELOW

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

In Schools. Revised Edition. oepa. Aa Bb Cc Dd Ee Radon Measurement. Air And Radiation (6604J)

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

A new passive integrating detector for measurement of individual radon exposure at working places.

Ramon 2.2 Radon-Monitor

THE EFFECT OF VENTILATION AND FILTRATION ON RADON DECAY PRODUCT MEASUREMENTS

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN

MEDICAL GEOLOGY/GEOCHEMISTRY

ABSTRACT FOR AARST CONFERENCE OCTOBER 1990 INSTRUMENTATION FOR RADON MEASUREMENT AND DIAGNOSIS

EagleRidge High School. Radon Testing Plan

What you need to know

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Multnomah Education Service District

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Identify the following features and specifications for the ESP1

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

Quality and Technology - Made in Germany -

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP

Pennsylvania Citizen s Guide to Radon. Test your home for radon it is easy and inexpensive.

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

June 7, 2016 PINCHIN LTD 1. Managing Radon in Buildings A Canadian Perspective SEMINAR OUTLINE WHAT IS RADON?

HEALTH AND SAFETY MANUAL

AIR POLLUTION Uncertainty Exists in Radon Measurements

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

WORKING. TOGETHER to PREVENT LUNG CANCER. A Guide to help you with testing your Child Care Centre for Radon

NSAW Radon Assessment 2017 QUESTIONS AND ANSWERS

radon Keeping your home safe from radon

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874

Surface Contamination Monitor. Operation Manual

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

Woodlin Elementary School Date of Report March 14, 2018

AC, AT, LS Measurement Devices

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817

Environmental Radiation Monitoring System

Nuclear Associates

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

CARST Guideline for Conducting Radon Measurements as Part of a Real Estate Transaction of Residential Dwellings in Canada (draft)

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor

A Citizen s Guide To Radon

adsw worth Center, New York State Department of Health, Albany, NY 12201

50(394) IEC. ore content meter ore sorting equipment overvoltage (of a Geiger-Müller county tube)...

Detectors used in the intercomparison

Transcription:

Topic 5 - Audio 56 Other Classifications Passive devices: Air diffuses in No power required for sampling Active devices: Requires power Pumps air through filter Key Points - Devices What lab sees: Different devices measure different variables. All measure rate of decay-not mass or volume. Secular Equilibrium: When radon in equilibrium with decay products Takes four-hours in a closed container Rate of decay of radon decay products is limited to rate of decay of radon since it has a much longer half-life than its short-lived decay products. Knowing the rate of decay of decay products, one then also knows the rate of decay of radon. Time characteristics: Continuous: Provide concentrations over different time intervals (typically by hour) Building investigations Indication of tampering Can also provide average for deployment period Time Integrating: Provide a single average measurement for deployment period Do not provide hourly measurements. Grab samples: Snapshots in time Diagnostic or investigation applications Sampling time: minutes Should not be used for determining need for, or success of mitigation. 1

Topic 5 - Audio 57 Activated Charcoal Device: Samples: Results: Sampling times: Activated charcoal (AC) Radon pci/l Open face: 2-3 days (short term) Diffusion barrier: 2-7 days Follow laboratory recommendations Number for real estate test 2 QA/QC: Performance test required? Lab sees: Influences: Key use tips Advantages: Disadvantages: 10% duplicates, maximum 50/month 5% blanks, maximum 25/month 3% spikes minimum 3/year, maximum 6/month No, unless you are the lab analyzing device Gamma from Lead-214 & Bismuth-214 High moisture gain causes under-response, but lab can correct for this by weighing device. Air blown across device will cause over-response Cold room temperatures cause over response Hot room temperatures causes under response Biased towards conditions in latter part of exposure Do not deploy in extremely humid environments Do not deploy where air will blow on it Do not deploy on hot surfaces or in direct sunlight Do not change weight of device Advise lab if deployed in a cold or hot location Be accurate as to dates and times Get to lab within a week Simple and inexpensive Considerable experience with device Limited to short-term testing Does not provide hourly variations 2

Topic 5 - Audio 58-63 3

Topic 5 - Audio 64 Alpha Track Detectors Device Samples: Results: Sampling times: Alpha Track Detector (ATD) Radon pci/l 91 days to year (Long-term) Number for real estate test: 1 Used commonly for post-purchase validation Used for follow-up measurements including post-mitigation testing QA/QC: Performance test required? Lab sees: Influences: Key use tips Advantages: Disadvantages: 10% duplicates, maximum 50/month 5% blanks, maximum 25/month 3% spikes minimum 3/year, maximum 6/month No, unless you are the lab analyzing device Alpha particles from radon that diffused in AND alpha from Polonium 214 and 218 produced from radon that entered device. Air blown across device can cause over-response Puncture in filter paper can cause over-response. Can pick-up radon if not stored properly Be accurate as to dates deployed Shut-Off device after test is done. Simple and inexpensive Considerable experience with device Used for long-term tests Limited to long-term testing Does not provide variations Precision can suffer if not exposed sufficient to radon (preferred minimum of 100 pci/l-days) 4

Topic 5 - Audio 65-68 5

Topic 5 - Audio 69 Electret Ion Chamber Device Samples: Results: Electret Ion Chamber (EIC) Radon pci/l (electret based ERPISU can also measure WL) Sampling times: Number for real estate test 2 QA/QC: Performance test required? Short-term (using S chambers and S-Electrets) Long-term (using L-chambers and L-Electrets) 10% duplicates, maximum 50/month 5% blanks, maximum 25/month 3% spikes minimum 3/year, maximum 6/month Reader calibrated once/year 5% set aside for voltage stability (should not exceed 1 volt/week for short-term or 1 volt /month for L electrets) Reference electret check of reader weekly Yes, unless a laboratory is reading voltages for you. Lab sees: Influences: Key use tips Advantages: Disadvantages: Radon enters device through diffusion filter. Radon and radon decay products break down. Alpha, beta & gamma causes ionization that changes charge on electret surface. External gamma can be accounted for Elevation can be accounted for Do not touch electret surface Keep electrets and chambers free of dust Keep reader in controlled environment Same reader used for several sampling devices Short-term and long-term Electrets can be reused until voltage drops to ~ 250V Does not provide variations over deployment period 6

Topic 5 - Audio 70-74 7

Topic 5 - Audio 75 Device Samples: Results: Sampling times: Number for real estate test Continuous Radon Monitors Continuous Radon Monitors (CRM) Radon pci/l Short-term 1 (provided measurements are in hourly increments) QA/QC: Annual calibration Annual background checks - scintillation style, once every 1,000 hrs 10% duplicates, with similar or like reading device Semi-annual cross-checks with recently calibrated device - Not required if check source available Routine instrument checks Air flow, (if applicable), batteries, etc. Performance test required? Lab sees: Yes No, if Blind Continuous Monitor where data sent to lab for report. Radon enters device and releases alpha which is detected and counted over time increments. Pulsed ion chamber (ion pulses) Silicon chip detector (electrical pulse) Scintillation cell (light flash) Influences: Key use tips Advantages: Disadvantages: Few, if placed per protocols Keep batteries charged Make results blind to occupant Provide hourly measurements Many also record temperature, movement, barometric pressure, etc. Can be expensive 8

Topic 5 - Audio 76-79 9

Topic 5 - Audio 80 Device Continuous Working Level Monitor Continuous Working Level Monitors (CWLM) Samples: Results: Sampling times: Number for real estate test QA/QC: Performance test required? Lab sees: Influences: Key use tips Advantages: Disadvantages: Radon decay products WL Short-term 1 (provided measurements are in hourly increments) Annual calibration Source check before each measurement New filter before each measurement 10% Duplicates if other CWLM or like device available Yes Radon and radon decay products are passed through a filter. Radon decay products adhere to filter. Alpha released from filter impacts detector. Impacts are counted over time increments. Measurement is a function of equilibrium factor Avoid location where air will blow directly on device. Regulate air flow carefully Avoid build up of dust on filter that would impede alpha particles from hitting detector (filter loading). Good idea to simultaneously deploy continuous radon measurement device. Provides hourly measurements Measures dose causing radon decay products Good for assessing benefit of air circulation and filters, especially in commercial buildings. Can be expensive 10

Topic 5 - Audio 81-83 11

Topic 5 - Audio 84 Device Samples: Results: Sampling times: Number for real estate test QA/QC: Performance test required? Lab Sees: Influences: Key use tips Advantages: Disadvantages: Electret Radon Progeny Integrating Sampling Unit Electret-Radon Progeny Integrating Sampling Unit (ERPISU) Radon Decay Products WL Short-term 2 (some devices have built in duplicate devices) Annual calibration New filter before each measurement 10% Duplicates if other CWLM or like measuring device available (note some units have two sampling units for 100% duplicates). No, if you are deploying device on behalf of certified lab No, if certified for electrets already but not developing reports. Yes, if you are analyzing and developing reports Radon and radon decay products pass through a filter. Radon decay products adhere to filter. Alpha released from filter enters electret chamber causing ionization. Radon decay products proportional to voltage drop, and air volume sampled. Measurement is a function of equilibrium factor Avoid location where air will blow directly on device. All factors that influence electrets (see section on EICs) Regulate air flow carefully Avoid build up of dust on filter that would impede alpha particles from hitting detector (filter loading). Good to simultaneously deploy with radon measurement device. Measures dose causing radon decay products. Uses same voltage reader as other electret devices. Assess benefit of air circulation/filters, especially commercial bldgs. Does not show hourly variations 12

Topic 5 - Audio 85 Key Points Grab Samples Grab Radon Collects known volume of air Scintillation cell or pulsed ion chamber detects alpha Sniff: sample measured directly after collection Very qualitative May be influenced by presence of Thoron (also an alpha emitter) Useful in finding areas of higher relative activities. Grab: Sample collected and held for four-hours before analyzing Allows for decay products to come into equilibrium Detects alphas from radon and Po-218 & Po-214 Very precise, but still limited to reporting levels at the time the sample was taken. Grab Working Level Measures radon decay products Collects volume of air through filter Filter removed and placed next to scintillation pad Alphas strike pad and release light Light measured by Photo Multiplier Tube and counted Times between sampling and successive measurements are critical Formula for calculating radon decay products is complex (see protocols if interested-but not a requirement to know formulas unless you plan to use these devices). No matter how accurate, no method that samples for less than 48-hours should be used for determining the need for mitigation. 13

Topic 5 - Audio 86 Significant Figures: Key Points Radon: Report to no more than one decimal place Examples: 3.1 pci/l - ok 3.11 pci/l - too many decimal places Radon Decay Products: Report to no more than three decimal places Examples: 0.033 WL - ok 0.0332 WL - too many decimal places Standard Deviation: If lab reports one standard deviation: Example: 4.0 pci/l + 0.5 pci/l, means: 68% of theoretically similar measurements would be between 3.5 pci/l and 4.5 pci/l, or There is a 68% chance that the measured radon is between 3.5 and 4.5 pci/l. If lab reports two standard deviations Example: 4.0 pci/l + 0.5 pci/l, means 95% of theoretically similar measurements would be between 3.5pCi/L and 4.5 pci/l, or There is a 95% chance that the measured radon is between 3.5 and 4.5 pci/l. Report: Dates & times Locations Device ID Test conditions Concerns 14