Product Guide. Wallmount. Air Conditioners & Heat Pumps

Similar documents
THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

WALL-MOUNT HEAT PUMPS - (60HZ)

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

Q-TEC Q24A-Q60A Air Conditioners

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

GREEN REFRIGERANT R-410A

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

Q-TEC QC-Series Chilled Water Air Conditioner

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Q-Tec TM QC-Series Chilled Water Air Conditioner

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

Wall Mounted Air Conditioners with Gas Heat Models AVGA

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Indoor Air Handlers with Compressors MVS and MVW

General Description. Operation

TECHNICAL SPECIFICATIONS

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

9-11+ EER 2-5 Ton Vertical Packaged Wall Mount Heat Pumps

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

PRODUCT SPECIFICATIONS

ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners

PAJ3. Product Specifications

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA

PAR5. Product Specifications

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

R4H4. Product Specifications

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

MAC-120HE-03 Air-Cooled Chiller

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

RSG16**S1M. Split System Air Conditioner 16 SEER

Q/Tec TM QA-Series Air Conditioners

TECHNICAL SPECIFICATIONS

GREEN REFRIGERANT R-410A

9-11+ EER 1-6 Ton Vertical Packaged Wall Mount Air Conditioners

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

R4H4. Product Specifications

Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

2 to 5 Ton Vertical Packaged Wall Mount Heat Pumps

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

General Description. Safety Listed

Submittal Summary Page

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Call us today! (800)

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

VertiCool Aurora Engineering Guide

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

General Description. Safety Listed

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

C13-Series Engineering Guide

RGE 13 A T - 1 A

Hazardous Location Certified

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Installation & Operation Manual 9-11 EER Vertical Wall-Mount Air Conditioners

HIGH EFFICIENCY AIR HANDLER

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Call us today! (800)

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Transcription:

Product Guide Wallmount Air Conditioners & Heat Pumps

Standard Features page 2 All Major Components can be Accessed from the Front 00 Hour Salt Spray rated powder coated baked paint finish AHRI certified High/ low pressure switches R4A Refrigerant Barometric damper gauge galvanized steel Expansion valves are standard on H series heat pumps, TV & TH series, SV & SH series Flow raters and pistons are standard on V series Built-in Circuit Breaker (Disconnect on volt models) air filter Mesa Tan color Scroll compressors Phase Monitors on 3 phase units Made in USA

Optional Features page 3 See Descriptions on Pages,, 2 Fresh Air Options Economizer Powered Room Ventilator (PRV) Energy Recovery Ventilator (ERV) available on S & T models only Low Ambient Package Sound Attenuation Module (SAM) Lead lag Controller Coated Coils 2 Pleated Filters Return & Supply Grilles White, Gray Cabinet Colors Digital Thermostat 3 Ton Back plate for 4 & 5 ton models Electric Heat Strips

EER V Series Air Conditioners H Series Heat Pumps Efficiency ratings from EER & 3.0 COP Available sizes:.5 to 5.0 ton Air Conditioners, 2.0 to 5.0 ton Heat Pumps 5 year limited warranty on parts and compressor Eubank Wallmount Model Key V 4 3 B A F D S - N B * N = Non Coated Coils 4 = Coated Coil Series Nominal Capacity Fresh Air D = Disposable Filter V = A/C 4=R4A =.5 Ton Electric Heat F = Barometric Damper P = 2 Pleated Filter H = Heat pump 24 = 2.0 Ton 05 = 05KW E = Economizer Cabinet Color = 2.5 Ton 0 = 0KW B = Solid Door B = Mesa Tan 3 = 3.0 Ton = KW P = PRV (Powered Room Ventilator) W = White 4 = 4.0 Ton = KW Electric Supply G = Gray 0 = 5.0 Ton 5 = 5KW = 20-2//0 = KW 3 = 20-2/3/0 C = Low ambient pkg Compressor type = Copeland Scroll 20 = 20KW 4 = /3/0 V Series Air Conditioners EER Model Cooling Capacity Volt/Phase/Hertz Weight Shipping/Net V4B**A,000 20-2//0 22/205 V424B**A 23,00 20-2//0 22/205 V4B**A 2,0 20-2//0 34/32 V4B**A3 2,0 20-2/3/0 34/32 V43B**A 35,000 20-2//0 352/324 V43B**A3 35,000 20-2/3/0 352/324 V43B**A4 35,000 /3/0 352/324 V44B**A 44,000 20-2//0 44/450 V44B**A3 44,000 20-2/3/0 44/450 V44B**A4 44,000 /3/0 44/450 VB**A 55,000 20-2//0 525/55 VB**A3 55,000 20-2/3/0 525/55 VB**A4 55,000 /3/0 525/55 See Complete Specifications on Pages to

V Series Electric Heaters & AC Unit Combinations for EER Voltage Size Part Number *Amps * BTU Output 24 3 4 0 2//0 5 kw EGA05B-AC 20. 7,000 kw EGAB-AC 4. 34,000 5 kw EGH5B-AC 2.5 5,000 20 kw EGH20B-AC 3,000 X X 2/3/0 kw EGH0B3-AC 4.4 20,000 X X kw EGH0B3-AC 2.7 3,000 X X 5 kw EGH5B3-AC 3 5,000 kw EGHB3-AC 43.3,000 X X /3/0 kw EGH0D4-AC 7.2 20,000 kw EGH0D4-AC. 3,000 5 kw EGH5D4-AC.0 5,000 X X H Series Heat Pumps EER Model Cooling Capacity Heating Capacity Volt/Phase/Hertz Weight Shipping/Net H424B**A 23,00 23,000 20-2//0 22/205 H4B**A 2,0 2,000 20-2//0 34/32 H4B**A3 2,0 2,000 20-2/3/0 34/32 H43B**A 35,000 34,000 20-2//0 352/324 H43B**A3 35,000 34,000 20-2/3/0 352/324 H43B**A4 35,000 34,000 /3/0 352/324 H44B**A 44,000 45,000 20-2//0 44/450 H44B**A3 44,000 45,000 20-2/3/0 44/450 H44B**A4 44,000 45,000 /3/0 44/450 HB**A 55,000 54,000 20-2//0 525/55 HB**A3 55,000 54,000 20-2/3/0 525/55 HB**A4 55,000 54,000 /3/0 525/55 H Series Electric Heaters & Heat Pump Unit Combinations Voltage Size Part Number *Amps *BTU Output 24 3 4 0 2//0 5 kw EGH05B-HP 20. 7,000 X X kw EGHB-HP 4. 34,000 X X 2/3/0 kw EGH0B3-HP 4.4 20,000 X X kw EGH0B3-HP 2.7 3,000 X X /3/0 kw EGH0D4-HP 7.2 20,000 X kw EGH0D4-HP. 3,000 X * BTU output and current based on 2 volts for 20-2 volts models and volts for volts models. * BTU multiplier for 2 volts operation multiply the listed output by 0.2; for 20 volts operation multiply by 0.75; for volts operation multiply by 0.2. * Current multiplier for 2 volts operation multiply by 0.; for 20 volts operation multiply by 0.7; for volts operation multiply by 0.. Easiest to Service! Condenser Coil is in the Back! See Complete Specifications on Pages to

High Efficiency T Series TV Series Air Conditioners TH Series Heat Pumps High Efficiency ratings up to 4 IPLV, + EER & 3.0 COP Available sizes: 3.0 to 5.0 ton Air Conditioners & Heat Pumps 5 year limited warranty on parts and compressor NOM ENCL AT U R E TV 3 S - FB - 00 MODEL SERIES TV = AIR CONDITIONER + EER SERIES TH = HEAT PUMP + EER SERIES SV = AIR CONDITIONER LOW SOUND SERIES SH = HEAT PUMP LOW SOUND SERIES NOMINAL COOLING CAPACITY 3 = 3,000 BTU/H NOMINAL ELECTRICAL SERVICE S = 20-2//0 T = 20-2/3/0 D = /3/0 ELECTRIC STRIP HEATER = kw Options Codes C = Low ambient kit B= Mesa Tan cabinet color (Std) 2= Coated cond coil G= Grey cabinet color P = MERV filter W= White cabinet color S = 2 step compressor FRESH AIR F = BAROMETRIC DAMPER (Std) E = ECONOMIZER B = SOLID DOOR P = PRV - Powered Room Ventilator V = ERV - Energy Recovery Ventilator TV Series Air Conditioners EER Model IPLV w/ 2 Step Compressor Cooling Capacity Volt/Phase/Hertz Weight Shipping/Net TV3S** 4 33,000 20-2//0 370/350 TV3T** 4 33,000 20-2/3/0 370/350 TV3D** 4 33,000 /3/0 370/350 TV4S** 3. 44,000 20-2//0 55/500 TV4T** 3. 44,000 20-2/3/0 55/500 TV4D** 3. 44,000 /3/0 55/500 TV0S** 2 55,000 20-2//0 520/500 TV0T** 2 55,000 20-2/3/0 520/500 TV0D** 2 55,000 /3/0 520/500 See Complete Specifications on Pages 20 to 23

TV Series Electric Heaters & AC Unit Combinations EER Voltage Size Part Number *Amps * BTU Output 3 4 0 2//0 5 kw ETA-05 20. 7,000 kw ETA- 4. 34,000 5 kw ETA-5 2.5 5,000 20 kw ETA-20 3,000 X X 2/3/0 kw ETA3-0 4.4 20,000 kw ETA3-0 2.7 3,000 5 kw ETA3-5 3 5,000 kw ETA3-43.3,000 X X /3/0 kw ETA4-0 7.2 20,000 kw ETA4-0. 3,000 5 kw ETA4-5.0 5,000 TH Series Heat Pumps EER Model Cooling Capacity Heating Capacity Volt/Phase/Hertz Weight Shipping/Net TH3S** 33,000 24,0 20-2//0 30/ TH3T** 33,000 24,0 20-2/3/0 30/ TH3D** 33,000 24,0 /3/0 30/ TH4S** 44,000 44,000 20-2//0 525/5 TH4T** 44,000 44,000 20-2/3/0 525/5 TH4D** 44,000 44,000 /3/0 525/5 TH0S** 55,000 52,000 20-2//0 5/5 TH0T** 55,000 52,000 20-2/3/0 5/5 TH0D** 55,000 52,000 /3/0 5/5 TH Series Electric Heaters & Heat Pump Unit Combinations EER Voltage Size Part Number *Amps *BTU Output 3 4 0 2//0 5 kw ETA-05-HP 20. 7,000 kw ETA--HP 4. 34,000 2/3/0 kw ETA3-0 4.4 20,000 kw ETA3-0 2.7 3,000 /3/0 kw ETA4-0 7.2 20,000 kw ETA4-0. 3,000 * BTU output and current based on 2 volts for 20-2 volts models and volts for volts models. * BTU multiplier for 2 volts operation multiply the listed output by 0.2; for 20 volts operation multiply by 0.75; for volts operation multiply by 0.2. * Current multiplier for 2 volts operation multiply by 0.; for 20 volts operation multiply by 0.7; for volts operation multiply by 0.. ENERGY RECOVERY VENTILATOR Pre-Conditions Fresh Air Using Exhaust Air FOR + EER EUBANK UNITS See Complete Specifications on Pages 20 to 23

High Efficiency Low Sound S Series SV Series Air Conditioners SH Series Heat Pumps High Efficiency ratings up to 4 IPLV, + EER & 3.0 COP Available sizes: 3.0, 4.0 & 5.0 ton Air Conditioners & Heat Pumps 5 year limited warranty on parts and compressor NOM ENCL AT U R E SV 3 S - FB - 00 MODEL SERIES TV = AIR CONDITIONER + EER SERIES TH = HEAT PUMP + EER SERIES SV = AIR CONDITIONER LOW SOUND SERIES SH = HEAT PUMP LOW SOUND SERIES NOMINAL COOLING CAPACITY 3 = 3,000 BTU/H NOMINAL ELECTRICAL SERVICE S = 20-2//0 T = 20-2/3/0 D = /3/0 ELECTRIC STRIP HEATER = kw Options Codes C = Low ambient kit 2= Coated cond coil B= Mesa Tan cabinet color (Std) P = MERV filter G= Grey cabinet color W= White cabinet color FRESH AIR F = BAROMETRIC DAMPER (Std) E = ECONOMIZER B = SOLID DOOR P = PRV - Powered Room Ventilator V = ERV Energy Recovery Ventilator SV Series Air Conditioners EER Model IPLV Cooling Capacity Volt/Phase/Hertz Weight Shipping/Net SV3S** 4 33,000 20-2//0 535/55 SV3T** 4 33,000 20-2/3/0 535/55 SV3D** 4 33,000 /3/0 535/55 SV4S** 3. 44,000 20-2//0 7/5 SV4T** 3. 44,000 20-2/3/0 7/5 SV4D** 3. 44,000 /3/0 7/5 SV0S** 2 55,000 20-2//0 75/700 SV0T** 2 55,000 20-2/3/0 75/700 SV0D** 2 55,000 /3/0 75/700 See Complete Specifications on Pages 24 to 27

SV Series Electric Heaters & AC Unit Combinations EER Voltage Size Part Number *Amps * BTU Output 3 4 0 2//0 5 kw ETA-05 20. 7,000 kw ETA- 4. 34,000 5 kw ETA-5 2.5 5,000 20 kw ETA-20 3,000 X X 2/3/0 kw ETA3-0 4.4 20,000 kw ETA3-0 2.7 3,000 5 kw ETA3-5 3 5,000 kw ETA3-43.3,000 X X /3/0 kw ETA4-0 7.2 20,000 kw ETA4-0. 3,000 5 kw ETA4-5.0 5,000 SH Series Heat Pumps EER Model Cooling Capacity Heating Capacity Volt/Phase/Hertz Weight Shipping/Net SH3S** 33,000 2,500 20-2//0 545/525 SH3T** 33,000 2,500 20-2/3/0 545/525 SH3D** 33,000 2,500 /3/0 545/525 SH4S** 43,500,000 20-2//0 720/705 SH4T** 43,500,000 20-2/3/0 720/705 SH4D** 43,500,000 /3/0 720/705 SH0S** 55,000 52,000 20-2//0 725/7 SH0T** 55,000 52,000 20-2/3/0 725/7 SH0D** 55,000 52,000 /3/0 725/7 SH Series Electric Heaters & Heat Pump Unit Combinations EER Voltage Size Part Number *Amps *BTU Output 3 4 0 2//0 5 kw ETA-05-HP 20. 7,000 kw ETA--HP 4. 34,000 2/3/0 kw ETA3-0 4.4 20,000 kw ETA3-0 2.7 3,000 /3/0 kw ETA4-0 7.2 20,000 kw ETA4-0. 3,000 * BTU output and current based on 2 volts for 20-2 volts models and volts for volts models. * BTU multiplier for 2 volts operation multiply the listed output by 0.2; for 20 volts operation multiply by 0.75; for volts operation multiply by 0.2. * Current multiplier for 2 volts operation multiply by 0.; for 20 volts operation multiply by 0.7; for volts operation multiply by 0.. World s Quietest Compact Wallmount by Eubank Reduces Inside Sound by % or More* Uses Same Wall Openings Does Not take Indoor Space SH SERIES * percentage reduction varies with site conditions See Complete Specifications on Pages 24 to 27

Optional Features page Low Ambient Kit Controls the head pressure in low outdoor temperature conditions. Head pressure is is maintained to keep the low pressure high enough to avoid a freeze up on the evaporator coil. Kit includes pressure Switch, crankcase heater and a control board with alarm contacts Coated Coils Coils can be coated for protection against corrosive attack. For use in areas where chemicals are present or near salt water. Electric Heaters Heat strips are available factory installed or as a kit to install in the field Models for AC & Heat Pump from 5KW. See heater and unit combinations tables for specific model 2 Pleated Filters Increase air filtration with a 2 pleated MERV filter. Fits into the same space as the standard disposable filter. Supply Grilles & Return Filter Grilles Exact fit inside grilles for Eubank AC & heat pump units. Available in white color only.

Optional Features page Fresh Air Options Powered Room Ventilator (PRV) The PRV is designed to operate any time the indoor fan motor is energized. Circulates up to 0% fresh air into the indoor while exhausting air out. Economizer Automatically regulated economizer is designed to cool the indoor space with outdoor air without running compressor when outdoor conditions permit. Control is based on outside temperature & humidity. Capable of delivering 0% fresh air. Energy Recovery Ventilator (ERV) for EER models only Pre-conditions incoming fresh air with exhaust air to transfer heat and moisture to save energy. Fits inside Eubank EER AC & Heat Pump models. Lead-Lag Controllers Available for AC units only, lead-lag controllers are designed to balance the operating run time between two AC units. To avoid down time on critical installations, two units each capable of providing 0% of the cooling are installed. The lead-lag controller operates one unit at a time sequencing their on & off times to prolong unit life. Non-Programmable Digital Thermostat Simple to use digital non-programmable thermostat from Eubank can be configured for either auto changeover or manual operation. Lockout features protect the settings from Being changed without a password. Thermostat is 24 VAC with an LCD display and a blue/green backlight. Dimensions are W x 4 H x.5 D in white. Order 45432 for heat/cool or 45432 for heat pump.

Optional Features page 2 Sound Attenuation Module - (SAM) Fits between wallmount units and the wall. Exclusive internal engineering design manages air direction attenuating and reducing the sound level from the unit to the inside space. Actual sound reduction ratios vary with application. Optional for all Eubank V, H and T series wallmounts and fits many competitors wallmounts that are EER or less. SAM-A-0 for 3 ton or less, SAM-B-0 for 3.5 to 5 ton 3 Ton Back Plate for 4 & 5 Ton Models Allows replacement of a 3 ton unit with a 4 or 5 ton unit without modifying existing wall openings. Back plate aligns the existing return and supply vents in the installation with a 4 or 5 ton unit. Optional Unit Colors External unit color is available in optional white or gray color. Standard color is Mesa Tan.

Questions for Replacing a Wallmount without a Model Number _page 3. Air conditioner or heat pump? 2. Which model? V&H series EER T series + EER S series + EER with sound attenuation module & 2 step compressor 3. What is the capacity? V series -.5, 2, 2.5, 3, 4 5 H series - 2, 2.5, 3, 4, 5 T series - 3, 4, 5 S series - 3, 4, 5 4. What voltage and phase are needed? 2//0 2/3/0 /3/0 5. Do they need electric heat strip and if so, what size?. What feature do they want for fresh air? V&H series - Barometric (std), Economizer, Power Room Ventilator, T series - Barometric (std), Economizer, Power Room Ventilator, ERV S series - Barometric (std), Economizer, Power Room Ventilator, ERV 7. Standard inch filter or 2 inch pleated MERV?. Coated coils for corrosive conditions?. Standard Mesa Tan color, Gray or White cabinet?. Do they need protection for low ambient temperature conditions?. Compare answers to Eubank Model Number Key on following page to determine Eubank model number

Wallmount Model Keys page 4 Bard Wallmount Model Key WA 3 A - A X X A Series Revision Electric Supply Fresh Air Cabinet Colors Control Modules WA = Right side A = 2/20-0- X = Barometric X = Beige Control panel A = A/C B = 2/20-0-3 Damper = white Coil & compressor H = Heat pump C = /0/3 B = Blank off 2 = Mesa tan X = standard WL = Left side plate 4 = gray = phenolic coated evap Control panel M = Motorized 5 = desert brown 2 = phenolic coated cond & compressor Electric Heat damper = dark bronze 3 = phenolic coated evap & S = blow through 04 = 4KW V = spring return A = aluminum condenser W = draw through Capacity 05 = 5 KW E = economizer S = stainless 7 =.5 Ton 42 = 3.5 Ton = KW D = economizer =.5 Ton 43 = 3.5 Ton 0 = KW R = ERV Outlet 24 = 2 Ton 4 = 4 Ton 0 = KW X = front 2 = 2 Ton 4 = 4 Ton = KW N = no filter T = top = 2.5 Ton 0 = 5 Ton 5 = 5KW X = disposable 3 = 2.5 ton = 5 Ton 20 = 20KW W = washable 3 = 3 Ton P = 2 pleated 3 = 3 Ton H = 2 pleated Marvair Wallmount Model Key AVP S A 3 AC A 0 X N X Compressor type A = R4A Capacity AC = A/C Electric heat Brand name Special options 24 = 2 Ton HP = heat pump 000 = none Air Source = 2.5 Ton 0 = 4KW Fresh Air Vertical Package 3 = 3 Ton Voltage 050 = 5KW N = manual damper (wallmount) 42 = 3.5 Ton A = 20/2/ 00 = KW Y = adjustable damper 4 = 4 Ton C = 20/2/3 00 = KW Z = adjustable damper 4 = 4 Ton D = /3 00 = KW B = motorized damper 0 = 5 Ton 0 = KW C = Economizer 20 = 2KW H = ERV 50 = 5KW Eubank Wallmount Model Key V 4 3 B A F D S - N B A N = non coated coil 4 = coated coil Series Capacity Fresh Air D = Disposable Filter V = A/C 4=R4A =.5 Ton Electric Heat F = Barometric Damper P = 2 Pleated Filter H = Heat pump 24 = 2.0 Ton 05 = 05KW E = Economizer Cabinet Color = 2.5 Ton 0 = 0KW B = Solid Door B = Mesa Tan 3 = 3.0 Ton = KW P = PRV (Powered Room Ventilator) W = White 4 = 4.0 Ton = KW Electric Supply 0 = 5.0 Ton 5 = 5KW = 20-2//0 A = Hi & Low pressure switch = KW 2 = 20-2/3/0 C = Low ambient pkg Compressor type = Copeland Scroll 20 = 20KW 4 = /3/0 2 = All of the above

Unit Dimensions for V, H and T series Eubank (Current)) Tonnage A B C D E F G H I J K L /24 3 34 2 2 20.5 2 20 2 7 /3 3 2 4 2 2 7 42/4/0 43 4 24 27 2 3 7 Tonnage A B C D E F G H I J K L Bard WA Series /24 35 34.3 7.25 2. 20.7 7. N/A. N/A N/A 70.53 /3 3.3 7.25 2 3. 7.3 7. N/A 27. N/A N/A 70.53 42/4/0 43. 43 20.432 25. 5.. N/A 2. N/A N/A 4.75 Marvair AVP Series Tonnage A B C D E F G H I J K L /24 3 7 2 2 20.5 2 20 2 7 /3 45 43 7 2 4 2 2 2 7 42/4/0 45 43 23 27 2 32

Dimensions, S series page

Specifications Section Schools Offices Leasing Companies Modular Bldgs. Trailers Storage Cell Towers Equipment Hubs Oilfield

V Series AC Specifications page AC Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) V4**A,000 20-2//0.0 /5 75.5 20"/2000 / 75.5 700/0. V424**A 23,00 20-2//0 2. /5 75.5 20"/2000 / 75.5 00/0. V4**A 2,0 20-2//0 /5 75.5 20"/2000 /3 75 2.5 250/0.5 V4**A3 2,0 20-2/3/0 /5 75.5 20"/2000 /3 75 2.5 250/0.5 V43**A 35,000 20-2//0 7. /5 75.5 20"/2000 /3 75 2.5 250/0.5 V43**A3 35,000 20-2/3/0 3.2 /5 75.5 20"/2000 /3 75 2.5 250/0.5 V43**A4 35,000 /3/0 /5 75 0.7 20"/2000 /3 75.2 250/0.5 V44**A 44,000 20-2//0 2.4 /2 0.5 22"/00 /2 0 3.5 00/0.20 V44**A3 44,000 20-2/3/0 4.5 /2 0.5 22"/00 /2 0 3.5 00/0.20 V44**A4 44,000 /3/0 7. /2 0.5 22"/00 /2 0 2 00/0.20 V**A 55,000 20-2//0. /2 0 2.5 22"/00 /2 0 3.7 20/0.20 V**A3 55,000 20-2/3/0 20.5 /2 0 2.5 22"/00 /2 0 3.7 20/0.20 V**A4 55,000 /3/0. /2 0.5 22"/00 /2 0. 20/0.20 (J) Rated in accordance with ANSI/ARI Standard 30-2003 (K) Includes factory-installed filters and wet coils Standard Ventilation Package AC Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper V4 70/25% V424 200/25% V4 0/25% V43 0/25% V44 450/25% V 525/25% 25"X"X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models V Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit AC Model 5 0 Total Sensible Total Sensible V4,000 2,000,000 3,000 V424 23,00 7,000 25,200 7,000 V4 2,0 2,0 3,0 22,000 V43 35,000 2,000 37,0 25,000 V44 44,000 34,200 50,000 34,000 V 55,000,000 5,0,500

V Series AC Electrical Data page SINGLE-FIELD CIRCUIT DUAL-FIELD CIRCUIT MODEL NO. & ELEC- TRIC HEATER kw [] VOLT/ PHAS E 0 Hz NO. OF FIELD POW- ER CKTS. MINIMUM CIRCUIT AMPACI- TY MAX FUSE OR HVACR BREAKER SIZE 2 FIELD POW- ER WIRE SIZE [3], [4], [5] GROUN D WIRE SIZE MIN. WIRE AMPACI- TY MAX FUSE OR HVACR BREAKER FIELD POWER WIRE SIZE [3], [4], [5] GROUN D WIRE SIZE CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 V4B00A 5 20-2/ 4 2 55 20 0 4 4 V424B00A 5 20-2/ 2 55 0 4 V424B00A 3 20-2/3 3 20 2 20 25 4 2 2 V4B00A 5 20-2/ 24 5 0 2 V4B00A 20-2/3 7 22 25 25 4 2 V43B00A 5 5 20-2/ 2 2 5 0 2 52 0 V43B00A 5 20/2/3 20 22 4 50 2 2 V43B00A 4 5 /3 5 5 20 4 4 4 4 4 2 V44B00A 5 5 20-2/ 2 33 33 5 50 50 0 27 52 0 V44B00A 5 20-2/3 24 24 33 50 0 0 70 2 2 V44B00A 5 /3 3 7 5 5 20 4 4 4 4 4 2 VB00B 5 5 20-2/ 2 3 3 5 0 0 0 33 52 0 VB00B 5 20-2/3 2 2 33 50 0 0 70 VB00B 5 /3 3 3 7 2 20 20 20 4 4 4 2 2 2 () Heater Data were based on 2 or V AC respectively (2) Maximum power recommended size for Time Delay fuse or HACR breaker (5) For single power conductor, sized per NEC Table 3 () Power supply wire minimum 75C rated COPPER CONDUCTOR ONLY (3) Power supply wire size and ground wires were based on AWG 75C rise, NEC Article 3

H Series Heat Pump Specifications page 20 HP Model EER 3.0 COP Cooling Heating Capacity (J) Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) H424**A 23,00 23,000 20-2//0 2. /5 75.5 20"/2000 / 75.5 00/0. H424**A3 23,00 23,000 20-2//0.4 /5 75.5 20 /2000 / 75.5 00/0. H4**A 2,0 2,000 20-2//0 /5 75.5 20"/2000 /3 75 2.5 250/0.5 H4**A3 2,0 2,000 20-2/3/0 /5 75.5 20"/2000 /3 75 2.5 250/0.5 H43**A 35,000 34,000 20-2//0 7. /5 75.5 20"/2000 /3 75 2.5 250/0.5 H43**A3 35,000 34,000 20-2/3/0 3.2 /5 75.5 20"/2000 /3 75 2.5 250/0.5 H43**A4 35,000 34,000 /3/0.0 /5 75 0.7 20"/2000 /3 75.2 250/0.5 H44**A 44,000 45,000 20-2//0 2.4 /2 0.5 22"/00 /2 0 3.5 00/0.20 H44**A3 44,000 45,000 20-2/3/0 4.5 /2 0.5 22"/00 /2 0 3.5 00/0.20 H44**A4 44,000 45,000 /3/0 7. /2 0.5 22"/00 /2 0 2.0 00/0.20 H**A 55,000 54,000 20-2//0 2.3 /2 0 2.5 22"/00 /2 0 4.0 20/0.20 H**A3 55,000 54,000 20-2/3/0 5. /2 0 2.5 22"/00 /2 0 4.0 20/0.20 H**A4 55,000 54,000 /3/0.7 /2 0.5 22"/00 /2 0 2.2 20/0.20 (J) Rated in accordance with ANSI/ARI Standard 30-2003 Standard Ventilation Package (K) Includes factory-installed filters and wet coils Heat Pump Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper H424 5/25% H4 2/25% H43 353/25% H44 425/25% H 45/25% 25"X"X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models H Series Heat Pump Cooling Performance Ambient Temperature Fahrenheit Heat Pump 5 Degrees 0 Degrees Model Total Sensible Total Sensible H424 23,00 7,000 25,200 7,000 H4 2,0 2,0 3,0 22,000 H43 35,000 2,000 37,0 25,000 H44 44,000 34,200 50,000 34,000 H 55,000 3,000 57,0 3,500 H Series Heat Pump Heating Performance Heat Pump Model Ambient Temperature Fahrenheit 47 Degrees 7 Degrees H424 23,00 5,000 H4 2,000,0 H43 34,000 2,000 H44 44,000 27,000 H 55,000 32,000

H Series Heat Pump Electrical Data page 2 SINGLE-FIELD CIRCUIT DUAL-FIELD CIRCUIT Model No. & Electric Heater Kw [] VOLT/ PHASE 0 Hz NO. OF FIELD POWER CKTS. MINIMUM CIRCUIT AMPACITY MAX FUSE OR HVACR BREAKER SIZE [2] FIELD POWER WIRE SIZE [3], [4], [5] GROUND WIRE SIZE MINIMUM WIRE AMPACITY MAX FUSE OR HVACR BREAKER [2] FIELD POWER WIRE SIZE [3], [4], [5] GROUND WIRE SIZE CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 H424B00A 5 20-2/ OR 2 45 70 50 0 4 4 52 0 4 H424B00A3 20-2/3 37 4 0 4 H4B00A 5 20-2/ OR 2 24 50 7 0 0 2 4 24 52 0 2 H4B00A3 20-2/3 24 42 50 50 0 4 4 H43B00A 5 20-2/ OR 2 2 52 7 0 0 2 0 2 0 H43B00A3 20-2/3 20 3 4 50 2 H43B00A4 /3 23 5 25 4 4 2 4 2 H44B00A 5 20-2/ OR 2 33 5 5 0 0 0 3 33 33 2 52 50 50 0 H44B00A3 20-2/3 24 42 50 50 0 2 H44B00A4 /3 20 25 5 25 4 2 4 HB00B 5 20-2/ OR 2 OR 2 3 5 0 0 0 0 4 3 3 3 2 52 0 0 0 HB00B3 20-2/3 2 44 53 50 0 HB00B4 /3 3 22 27 20 25 4 2 2 () Heater Data were based on 2 or V AC respectively (2) Maximum power recommended size for Time Delay fuse or HACR breaker (3) Power supply wire size and ground wires were based on AWG 75C rise, NEC Article 3 and Table 3- (4) For single power conductor, sized per NEC Table 3 (5) Power supply wire minimum 75C rated COPPER CONDUCTOR ONLY () Max kw heat with heat pump operation. Full electric heat available in heat mode

TV Series AC Specifications page 22 AC Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) TV3S** 33,000 20-2//0.7 / 25.2 22"/2000 /3 Variable. 250/0.5 TV3T** 33,000 20-2/3/0.4 / 25.2 22"/2000 /3 Variable. 250/0.5 TV3D** 33,000 /3/0 5.7 / 25 0.7 22"/2000 /3 Variable.3 250/0.5 TV4S** 44,000 20-2//0 2. /2 00 2. 22"/00 /2 Variable 2.7 00/0.20 TV4T** 44,000 20-2/3/0 3.7 /2 00 2. 22"/00 /2 Variable 2.7 00/0.20 TV4D** 44,000 /3/0.2 /2 00.4 22"/00 /2 Variable. 00/0.20 TV0S** 55,000 20-2//0 2.3 /2 00 2. 22"/00 /2 Variable 2.7 20/0.20 TV0T** 55,000 20-2/3/0 5. /2 00 2. 22"/00 /2 Variable 2.7 20/0.20 TV0D** 55,000 /3/0 7.7 /2 00.4 22"/00 /2 Variable. 20/0.20 (J) Rated in accordance with ANSI/ARI Standard 30-2003 (K) Includes factory-installed filters and wet coils Standard Ventilation Package AC Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper TV3 3/25% TV4 425/25% TV0 500/25% 4 or X "X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models TV Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit AC Model 5 0 Total Sensible Total Sensible TV43 33,000 24,0 35,0 2,0 TV44 44,000 34,000 4,000 37,000 TV 55,000,000 0,000 44,000

TV Series AC Electrical Data page 23 SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT Model No. & Electric Heater Kw [] Volt / Phase No. of Field Power Ckts MINI- MUM CIRCUIT AM- PACICY MAX OVER CUR- RENT PROTEC- TION [2] FIELD POWER WIRE SIZE [3], [4],[5] GROUND WIRE SIZE MIM WIRE AMPAC- ITY MAX OVER CUR- RENT PROTECTION [2] FIELD POWER WIRE SIZE [3],[4], [5] GROUND WIRE SIZE TV3S** 23 2 CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 5 20-2/ 5 0 5 2 2 52 0 TV3T** 4 20-2/3 22 2 5 4 50 TV3D* * 5 4 4 /3 5 4 4 5 20 4 2 5 25 TV4S** 33 50 5 33 50 20-2/ 5 0 5 2 27 52 0 TV4T** 24 2 24 2 20-2/3 33 5 50 0 OR 2 0 70 TV4D* 2 5 4 4 3 5 4 4 /3 7 20 4 2 5 2 TV0S** 0 24 54 0 2 5 0 20-2/ 5 0 5 2 34 52 0 TV0T** 27 27 20-2/3 33 5 50 0 OR 2 0 0 TV0D* 2 5 4 4 27 54 0 /3 2 5 4 4 7 20 4 2 5 2 [] Heater data were based on 2V or V AC respectively. [2] Maximum recommended size for "Time Delay" fuse or HACR circuit breaker. [3] Power supply wire size and ground wire sizez were based on AWG 75C rise, NEC Article 3 and Table 3.5(B)(). [4] For single power conductor, sized per NEC Table 3.5(B)(7). [5] Power supply wire 75C rated COPPER CONDUCTOR ONLY.

TH Series Heat Pump Specifications page 24 HP Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) TH3S** 33,000 20-2//0 5.3 / 25.2 22"/2000 /3 Variable. 250/0.5 TH3T** 33,000 20-2/3/0. / 25.2 22"/2000 /3 Variable 250/0.5 TH3D** 33,000 /3/0 5.7 / 25 0.7 22"/2000 /3 Variable.3 250/0.5 TH4S** 44,000 20-2//0 2.2 /2 00 2. 22"/00 /2 Variable 2.7 700/0.20 TH4T** 44,000 20-2/3/0 4 /2 00 2. 22"/00 /2 Variable 2.7 700/0.20 TH4D** 44,000 /3/0.4 /2 00.4 22"/00 /2 Variable. 700/0.20 TH0S** 55,000 20-2//0 27. /2 00 2. 22"/00 /2 Variable 2.7 2200/0.20 TH0T** 55,000 20-2/3/0.5 /2 00 2. 22"/00 /2 Variable 2.7 2200/0.20 TH0D** 55,000 /3/0 7.2 /2 00.4 22"/00 /2 Variable. 2200/0.20 (J) Rated in accordance with ANSI/ARI Standard 30-2003 (K) Includes factory-installed filters and wet coils Standard Ventilation Package HP Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper TH3 3/25% TH4 425/25% TH0 500/25% 4 or X "X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models TH Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit HP Model 5 0 Total Sensible Total Sensible TH3 33,000 24,0 35,0 2,0 TH4 44,000 32,700 47,000 35,000 TH0 55,000,000 0,000 44,000 TH Series Heat Pump Heating Performance Heat Pump Model Ambient Temperature Fahrenheit 47 Degrees 7 Degrees TH43 32,000,00 TH44 43,500 27,000 TH 52,000 3,000

TH Series Heat Pump Electrical Data page 25 SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT Model No. & Electric Heater Kw [] Volt / Phase No. of Field Power Ckts MINI- MUM CIRCUIT AM- PACICY MAX OVER CUR- RENT PROTEC- TION [2] FIELD POWER WIRE SIZE [3], [4],[5] GROUND WIRE SIZE MIM WIRE AMPAC- ITY MAX OVER CUR- RENT PROTECTION [2] FIELD POWER WIRE SIZE [3],[4], [5] GROUND WIRE SIZE TH3S** 23 2 CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 5 20-2/ 4 50 OR 2 75 0 4 23 52 5 0 2 4 TH3T** 4 20-2/3 37 4 50 TH3D** 5 4 4 20 4 2 /3 23 25 2 TH4S** 33 50 5 OR 2 5 70 33 2 50 20-2/ OR 2 5 0 3 33 52 50 0 TH4T** 24 2 42 50 20-2/3 50 0 TH4D** 2 5 4 4 20 25 2 /3 25 TH0S** 0 5 OR 2 0 4 2 0 20-2/ OR 2 2 0 3 52 0 0 TH0T** 27 45 50 20-2/3 54 0 TH0D** 2 5 4 4 /3 20 25 2 2 [] Heater data were based on 2V or V AC respectively. [2] Maximum recommended size for "Time Delay" fuse or HACR circuit breaker. [3] Power supply wire size and ground wire sizez were based on AWG 75C rise, NEC Article 3 and Table 3.5(B)(). [4] For single power conductor, sized per NEC Table 3.5(B)(7). [5] Power supply wire 75C rated COPPER CONDUCTOR ONLY.

SV Series AC Specifications page 2 AC Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) SV3S** 33,000 20-2//0 5.3 / 75.2 22"/2000 /3 50. 250/0.5 SV3T** 33,000 20-2/3/0. / 75.2 22"/2000 /3 50. 250/0.5 SV3D** 33,000 /3/0 5.7 / 75 0.7 22"/2000 /3 50.3 250/0.5 SV4S** 43,500 20-2//0 2.2 /2 0 2. 22"/00 /2 50 2.7 700/0.20 SV4T** 43,500 20-2/3/0 4 /2 0 2. 22"/00 /2 50 2.7 700/0.20 SV4D** 43,500 /3/0.4 /2 0.4 22"/00 /2 50. 700/0.20 SV0S** 55,000 20-2//0 27. /2 0 2. 22"/00 3/4 50 4.5 2200/0.20 SV0T** 55,000 20-2/3/0.5 /2 0 2. 22"/00 3/4 50 4.5 2200/0.20 SV0D** 55,000 /3/0 7.2 /2 0.4 22"/00 3/4 50 3.7 2200/0.20 (J) Rated in accordance with ANSI/ARI Standard 30-2003 (K) Includes factory-installed filters and wet coils Standard Ventilation Package AC Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper SV3 3/25% SV4 425/25% SV0 500/25% 4 or X "X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models SV Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit AC Model 5 0 Total Sensible Total Sensible SV3 33,000 24,0 35,500 25,000 SV4 43,500 34,500 50,000 37,000 SV0 55,000,000 0,000 44,000

SV Series AC Electrical Data page 27 SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT Model No. & Electric Heater Kw [] Volt / Phase No. of Field Power Ckts MINIMUM CIRCUIT AM- PACICY MAX OVER CURRENT PROTEC- TION [2] FIELD POWER WIRE SIZE [3], [4],[5] GROUND WIRE SIZE MIN WIRE AMPACITY MAX OVER CURRENT PROTECTION [2] FIELD POWER WIRE SIZE [3],[4],[5] GROUND WIRE SIZE CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 SV3S** 23 2 5 20-2/ 5 0 5 2 2 52 0 SV3T** 4 20-22 2 2/3 5 4 50 SV3D** 5 4 4 5 4 4 /3 5 20 4 2 5 25 SV4S** 33 50 5 33 50 20-2/ 5 0 5 2 27 52 0 SV4T** 24 2 24 2 20-2/3 33 5 50 0 OR 2 0 70 24 54 0 2 SV4D** 2 5 4 4 3 5 4 4 /3 7 20 4 2 5 2 SV0S** 0 5 0 20-2/ 5 0 5 2 34 52 0 SV0T** 27 27 20-2/3 33 5 50 0 OR 2 0 0 27 54 0 SV0D** 2 5 4 4 2 5 4 4 /3 7 20 4 2 5 2 [] Heater data were based on 2V or V AC respectively. [2] Maximum recommended size for "Time Delay" fuse or HACR circuit breaker. [3] Power supply wire size and ground wire sizez were based on AWG 75C rise, NEC Article 3 and Table 3.5(B)(). [4] For single power conductor, sized per NEC Table 3.5 (B)(7). [5] Power supply wire 75C rated COPPER CONDUCTOR ONLY.

SH Series Heat Pump Specifications page 2 HP Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) SH3S** 33,000 20-2//0 5.3 /.2 22"/2000 /3 50. 250/0.5 SH3T** 33,000 20-2/3/0. /.2 22"/2000 /3 50. 250/0.5 SH3D** 33,000 /3/0 5.7 / 0.7 22"/2000 /3 50.3 250/0.5 SH4S** 43,500 20-2//0 2.2 /2 0 2. 22"/00 /2 50 3.2 700/0.20 SH4T** 43,500 20-2/3/0 4 /2 0 2. 22"/00 /2 50 3.2 700/0.20 SH4D** 43,500 /3/0.4 /2 0.4 22"/00 /2 50 2. 700/0.20 SH0S** 55,000 20-2//0 27. /2 0 2. 22"/00 3/4 50 4.5 2200/0.20 SH0T** 55,000 20-2/3/0.5 /2 0 2. 22"/00 3/4 50 4.5 2200/0.20 SH0D** 55,000 /3/0 7.2 /2 0.4 22"/00 3/4 50 3.7 2200/0.20 (J) Rated in accordance with ANSI/ARI Standard 30-2003 (K) Includes factory-installed filters and wet coils Standard Ventilation Package HP Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper SH3 3/25% SH4 425/25% SH0 500/25% 4 or X "X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models SH Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit HP Model 5 0 Total Sensible Total Sensible SH3 33,000 24,0 35,500 25,000 SH4 43,500 34,500 50,000 37,000 SH0 55,000,000 0,000 44,000 SH Series Heat Pump Heating Performance Heat Pump Model Ambient Temperature Fahrenheit 47 Degrees 7 Degrees SH43 2,500 7,500 SH44,000 25,000 SH 52,000 3,000

SH Series Heat Pump Electrical Data page 2 SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT Model No. & Electric Heater Kw [] Volt / Phase No. of Field Power Ckts MINIMUM CIRCUIT AMPACICY MAX OVER CURRENT PROTEC- TION [2] FIELD POWER WIRE SIZE [3], [4],[5] GROUND WIRE SIZE MIM WIRE AMPACITY MAX OVER CUR- RENT PROTECTION [2] FIELD POWER WIRE SIZE [3],[4],[5] GROUND WIRE SIZE CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 SH3S** 23 2 5 4 50 20-2/ OR 2 75 0 4 23 52 5 0 2 4 SH3T** 4 37 20-2/3 4 50 SH3D** 5 4 4 20 4 2 /3 23 25 2 SH4S** 33 50 5 OR 2 5 70 33 2 50 20-2/ OR 2 5 0 3 33 52 50 0 SH4T** 24 2 42 50 20-2/3 50 0 SH4D** 2 5 4 4 20 25 2 /3 25 SH0S** 0 5 OR 2 0 4 2 0 20-2/ OR 2 2 0 3 52 0 0 SH0T** 27 45 50 20-2/3 54 0 SH0D** 2 5 4 4 20 25 2 /3 2 () Heater Data were based on 2 or V AC respectively (2) Maximum power recommended size for Time Delay fuse or HACR breaker (3) Power supply wire size and ground wires were based on AWG 75C rise, NEC Article 3 and Table 3- (4) For single power conductor, sized per NEC Table 3 (5) Power supply wire minimum 75C rated COPPER CONDUCTOR ONLY () Max kw heat with heat pump operation. Full electric heat available in heat mode

Looking for Quiet? Look to... S series The Eubank S series Reduces Indoor Sound Documented to as low as.3 decibels (dba)* Quiet and High Efficiency! *Actual sound levels may vary depending on conditions. INNOVATION Same Cabinet Dimensions Same Supply & Return Dimensions Increased Efficiency + EER T Series EER V&H Series

Will it Fit? YES! Supply Air Openings - the SAME! Supply Air Opening Return Air Openings - the SAME! Distance between openings - the SAME! Return Air Opening All Eubank units will replace most existing EER or less units of the same tonnage on the market Exact dimensions on pages 5 & of Product Guide Easy to Service? Eubank! Access compressor from the front Access condenser motor and blade from the front Access electrical components from the front Access slide out blowers from the front Coil surface is protected from accidental damage Coil surface is out of direct sunlight to help reduce load

Product Guide V & H series V for A/C & H for Heat Pump Standard Efficiency Quick Reference: pages 4, 5 Dimensions: 5 Specifications: pages through 2 T series High Efficiency TV for A/C & TH for Heat Pump Single Step Compressor, ECM Blower Motor Quick Reference: pages, 7 Dimensions: 5 Specifications: pages 22 through 25 S series High Efficiency Low Sound SV for A/C & SH for Heat Pump Two Step Compressor, ECM Blower Motor ECM Condenser Motor, Sound Attenuation Module (SAM) Enhancements to the Cabinet to Minimize Sound Vibrations Quick Reference: pages, Dimensions: Specifications: pages 2 through 2 Product Guide June 207 Eubank is a registered trademark of Airxcel, Inc. Due to manufacturer s policy of continuous product improvement, the manufacturer reserves the right to make changes without notice. All product specifications reflect available information at the printing of this brochure. All rights reserved. Eubank 5 Seedling Drive Cordele, GA 35 22.273.33 Fax 22.273.554