Operation, Maintenance and Installation Manual

Similar documents
TECHNICAL DATA. Wet 26a. February 22, 2009

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

SuperKlean Washdown Products

FLUSH WATER SAVER DUAL FLUSH KIT

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

AeroVent 3X Product Manual

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

1.6 GALLON ONE PIECE TOILET

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

INSTALLATION & TESTING MANUAL

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Troubleshooting the MPH 24FP Series Pedestal Hydrant

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Platen Heater Pad Replacement

Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

TITAN FLOW CONTROL, INC.

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

Installation & Service Guide

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

INSTALLATION & OPERATING INSTRUCTIONS

Lifetime Limited Warranty

Unpacking Your Fan 2.

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Model Combination Shower Eye/Face Wash

Here is what comes in your box:

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

GP22/32 SERIES Sealed Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Model /8320CRP Shower and Eye/Face Wash

Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario

ST. KITTS CEILING FAN

INSTALLATION INSTRUCTIONS

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Industrial Vacuums, Inc


INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. QuickTrap FX1 Trap Unit X1. Manufacturer

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

XT Series Thermostats

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

TOUCHDOWN 48 CEILING FAN

Types TMUB, TMUAH and. J Jockey Pumps

Lifetime Limited Warranty

Larson by Hampton Bay

Models: FM FM WARNING

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

NISSAN FRONTIER INSTALLATION INSTRUCTIONS

INSTALLATION & TESTING MANUAL

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

Bubble 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS

MG200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential and Pressure Sewer Applications.

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Decorative Low Profile Integrated Kit

TECHNICAL INSTRUCTIONS

Installation Manual. Models 99168, 99169, 99170

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

CARE AND USE GUIDE VACUUM INSULATED HYDRATION BOTTLE

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Model 7656WCC Eye/face Wash

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Elite Primer Baldor Series External Pond Pump

60, 52" or 42" CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

INSTALLATION ADJUSTMENT SERVICE

HIGH EFFICIENCY CIRCULATOR INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL

AeroVent 1 Product Manual

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

13-1. Temperature Regulator

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

OWNERS GUIDE TO INSTALLATION AND OPERATION

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

A COMPLETE GUIDE TO OPERATION, TROUBLESHOOTING AND SERVICE PROCEDURES 2005 DRY AIR SYSTEMS Group (04/05)

569, 570, 571, 572 Series

Single-Control Lavatory Faucet

52 SAN LUCAS CEILING FAN

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

MILLENIUM MEMBRANE REPLACEMENT. Tools and Materials Required. Initial Preparation

52 BERKSHIRE CEILING FAN

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

52 CEILING FAN. Owner s Manual Models #50336, 50337

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

Transcription:

Manual No. FS-OM1-5 1-16 in. FloodSafe Inflow Preventer Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 CONSTRUCTION... 2 MAINTENANCE... 3 TROUBLESHOOTING... 3 DISASSEMBLY... 3 REASSEMBLY... 3 FIELD TESTING... 4 TEST REPORT... 5 PARTS AND SERVICE... 6 WARRANTY... 6 VAL-MATIC VALVE AND MANUFACTURING CORP. 905 Riverside Dr. Elmhurst, IL 60126 Phone (630) 941-7600 Fax (630) 941-8042 www.valmatic.com

1 1-16 in. FloodSafe Inflow Preventer OPERATION, MAINTENANCE AND INSTALLATION INTRODUCTION This manual will provide you with the information to properly install, maintain and ensure a long service life for the FloodSafe inflow preventer. The FloodSafe is to be installed on the outlet of an air release or air/vacuum valve to prevent cross contamination of the potable water system due to flooding and malicious tampering as described in ASSE Standard 1063. The FloodSafe is designed with two float checks that are open during normal pipeline operation to allow full airflow in both directions. The float check(s) will rise and seal when the surrounding atmosphere is filled with water. RECEIVING AND STORAGE Inspect the FloodSafe upon receipt for damage in shipment. Unload all devices carefully to the ground without dropping. Remove all blocking material inside of the metal basket. The devices should remain boxed, clean and dry until installed to prevent weather related damage. For long term storage greater than six months, the rubber seat should be coated with a thin film of FDA approved grease. Do not expose rubber seat to sunlight or ozone for any extended period. DESCRIPTION OF OPERATION The FloodSafe inflow preventer is designed with a lower chamber and upper, redundant chamber. Both chambers contain identical float checks that are open during normal pipeline operation and allow full airflow in both directions. If flooding occurs the lower float check will rise, preventing floodwater from reaching the outlet of the air valve and subsequently the pipeline. If the lower float check fails the upper, redundant float check will close preventing floodwater from reaching the air valve. The basket screen prevents debris from interfering with the operation of the FloodSafe. Figure 1. FloodSafe Inflow Preventer Figure 2. Typical Installation

INSTALLATION Remove the packing from the top and bottom of the FloodSafe that is used to protect the floats during shipping. Install the basket per step 6 in the REASSEMBLY section on page 3. The installation of the FloodSafe is important for its proper operation. The FloodSafe should be installed plumb in the vertical position with the basket facing downward. Thread or bolt the FloodSafe to the outlet of an air valve using standard connection practices. The bolting for 6" and larger devices conforms to ANSI B16.1 for class 125# flanges. An optional mounting bracket (80) may be used to mount the device to wall supports. FLOODSAFE CONSTRUCTION The standard FloodSafe is constructed of ductile iron. Stainless steel type 316 float checks are the only moving elements and seal against a low hardness resilient seat. The general details of construction are illustrated in Figure 3 and identified in Table 2. Flanged connections should only be mated with flatfaced pipe flanges equipped with full-face or ring type resilient gaskets. The bolts should be tightened in gradual steps using the crossover method. Recommended torque values are given in Table 1. CAUTION: The use of excessive bolt torque may damage the device. Table 1. Flange Bolt Torques Mounting Flange Bolts (ANSI B16.1 Class 125) Device Size Bolt Size Recommended Torque (ft-lbs) Maximum Torque (ft-lbs) 6 3/4" 30 150 8 3/4" 40 150 12 7/8 45 200 16 1 90 300 Figure 3. FloodSafe Components Table 2. FloodSafe Parts List Item Description Material 1A,1B Chamber Ductile Iron 2 Cover Ductile Iron 4A,4B Seat Resilient 5A,5B Float Check T316 Stainless Steel 7A,7B Bolts, Nuts T316 Stainless Steel 8 Basket Retainer T316 Stainless Steel 12 Basket T304 Stainless Steel 14 Pipe Plug Carbon Steel 80* Mounting Bracket Carbon Steel 80A* Mounting Bolt T316 Stainless Steel 2

MAINTENANCE The FloodSafe requires no scheduled lubrication or maintenance. INSPECTION: The FloodSafe may be checked for debris by following the disassembly and reassembly instructions. The seat may be checked for cracks or tears. The float check may be inspected for indentations or deep scratches on the top sealing portion. TROUBLESHOOTING Several problems and solutions are presented below to assist you in troubleshooting the FloodSafe in an efficient manner. Air valve water discharge: It is normal for air valves to discharge some water before closing. Continuous leakage requires maintenance of the adjacent air valve. Leaks during field test: Clean and inspect the resilient seats and the float checks. DISASSEMBLY WARNING Close the isolation valve underneath the adjacent air valve. Failure to close the isolation valve may allow discharge of air into the FloodSafe and cause bodily injury. Note: If the FloodSafe is connected to the optional mounting bracket (80), the FloodSafe will need to be removed from the bracket. 1. Remove the basket (12). a) On sizes with side taps, use an allen wrench to loosen the screws holding the basket to the lower chamber (1B). Rotate the basket counterclockwise and pull the basket down and away from the chamber. b) On sizes without the side taps, use an openend wrench to remove the bolts holding the basket to the lower chamber flange. 3. Remove the seat (4) by pulling it upward and out of the chamber. Tilt the chamber to remove the float check (5). 4. The upper chamber is removed in the same manner as the lower chamber. Remove the bolts joining the chamber and cover using care to support the chamber. The seat and float check can be removed in the same manner as before. REASSEMBLY All parts must be clean. Worn or damaged parts should be replaced during reassembly. 1. Install the float check (5A) into the chamber (1A). 2. Insert the seat (4A) with the raised circular surface facing down into the chamber (1A). 3. Connect the upper chamber (1A) to the cover (2) with the bolts (7A) and nuts (7B) using the cross over method. One washer is installed under the head of the bolt and one underneath the nut. 4. Install the float check and seat into the lower chamber per steps 1 and 2. 5. Connect the lower chamber (1B) to the upper chamber (1A) by using the bolts (7A) and (7B). One washer is installed under the head of the bolt and one underneath the nut. 6. Install the basket (12) to the lower chamber (1B). a) On sizes with the side taps, start the socket head cap screws into the lower chamber flange. Install the basket by pushing upward and turning clockwise. Tighten the socket head cap screws to secure the basket. b) On sizes without the side bolts, install the bolts through the bottom flange and into the tapped holes on the basket screen. One washer is used underneath the head of the bolt. 2. Remove the lower chamber (1B) by removing the bolts (7A) and nuts (7B) joining the two chamber halves. CAUTION The FloodSafe chambers may be heavy. Support the chambers when removing the bolts in order to prevent bodily injury. 3

FIELD TESTING THE FLOODSAFE The FloodSafe inflow preventer should be tested after installation, and periodically thereafter as recommended by the local authority having jurisdiction, but at least annually. For field testing, a testing kit available from the manufacturer is required consisting of test cocks and a test pipe that can be used for multiple installations. ISOLATE DEVICE 1. Close the isolation valve under the adjacent air valve with which the FloodSafe is connected. 2. Remove the three pipe plugs on the side of the FloodSafe and install the test cocks provided with the test kit. Open the three test cocks A, B, and C. 3. Remove the basket screen by loosening the screws and twisting the screen. Clean the basket if needed. 4. Install test plate to close off the bottom outlet. TEST LOWER CHAMBER 5. Connect the test pipe to test cock A in the lower chamber as shown in Figure 4. A quickdisconnect coupling is provided to facilitate the assembly. 6. Fill the clear test pipe and lower chamber with clean water by pouring water into the test pipe and maintain the water level above the Minimum Test Level for 5 minutes while observing test cock B for leakage. The water level in the tube may drop due to leakage in the fittings, bottom plug, or as air escapes between the float and the seat (acceptable). The device shall be rejected and repaired if water is observed from test cock B during the 5 minute test period. TEST UPPER CHAMBER 7. Close test cock A. Move the test pipe up to the upper chamber test cock B. A quick-disconnect fitting under the clear pipe will aid in its removal. 8. Fill the clear test pipe and upper chamber with clean water by pouring water into the test tube and maintain the water level above the Minimum Test Level for 5 minutes while observing test cock C for leakage. The device shall be rejected and repaired if water is observed from test cock C during the 5 minute test period. 9. If one of the initial tests fail and repairs are made, a Final Test shall be conducted and recorded. Repairs typically consist of removing the chamber bolts and cleaning the float and cleaning or replacing the rubber seat. RETURN TO SERVICE 10. When the tests are complete, open test cock A and drain the water and remove the test piping and bottom test plate. The test cocks may be left in the device, but all three must to be closed. 11. Re-assemble the basket screen to the lower chamber. Tighten the screen bolts. 12. IMPORTANT: Open the isolation valve underneath the air valve that was closed in step 1. Figure 4: Field Test Piping 4

FloodSafe Inflow Preventer TEST AND MAINTENANCE REPORT OWNER: ADDRESS: LOCATION OF ASSEMBLY: MANUFACTURER: MODEL NO: YEAR OF MANUFACTURE: SIZE: PROCEDURE: See FIELD TESTING THE FLOODSAFE in the Instruction Manual. 1. Isolation Valve Under Air Valve 2. Inflow Preventer Test Lower Chamber 3. Inflow Preventer Test Upper Chamber leaked or closed off tight test cocks OK or test cocks replaced test cock OK or test cock replaced Record any maintenance performed: Inflow Preventer Basket removed and cleaned Bottom Plug installed Initial Tests: Repairs: open test cocks Connect test pipe assembly to test cock A. Fill lower chamber and test pipe with clean water. Maintain water level above Minimum Test Level Observe test cock B for leakage for 5 minutes. Any sign of leakage from test cock is cause for rejection. Record maintenance performed: Connect test pipe assembly to test cock B. Fill upper chamber and test pipe with clean water. Maintain water level above Minimum Test Level Observe test cock C for leakage for 5 minutes. Any sign of leakage from test cock is cause for rejection. Record maintenance performed: Final Tests (when needed): If initial test failed, repeat 5 minute test. Any sign of leakage from test cock B is cause for rejection. If initial test failed, repeat 5 minute test. Any sign of leakage from test cock C is cause for rejection. IMPORTANT: After testing, reopen the isolation valve under the air valve. NOTE: All repairs and final tests should be completed within five (5) working days. COMMENTS: I hereby certify that this data is accurate and reflects the proper maintenance of the assembly. TESTER: CERT No. DATE: THIS ASSEMBLY: Passed Failed TIME: 5

PARTS AND SERVICE Parts and service are available from your local representative or the factory. Make note of the Valve Size and Model Number located on the valve nameplate and contact: Val-Matic Valve and Manufacturing Corp. 905 Riverside Drive Elmhurst, IL 60126 Phone: (630) 941-7600 Fax: (630) 941-8042 www.valmatic.com A sales representative will quote prices for parts or arrange for service as needed. LIMITED WARRANTY All products are warranted to be free of defects in material and workmanship for a period of one year from the date of shipment, subject to the limitations below. If the purchaser believes a product is defective, the purchaser shall: (a) Notify the manufacturer, state the alleged defect and request permission to return the product; (b) if permission is given, return the product with transportation prepaid. If the product is accepted for return and found to be defective, the manufacturer will, at his discretion, either repair or replace the product, f.o.b. factory, within 60 days of receipt, or refund the purchase price. Other than to repair, replace or refund as described above, purchaser agrees that manufacturer shall not be liable for any loss, costs, expenses or damages of any kind arising out of the product, its use, installation or replacement, labeling, instructions, information or technical data of any kind, description of product use, sample or model, warnings or lack of any of the foregoing. NO OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, ARE MADE OR AUTHORIZED. NO AFFIRMATION OF FACT, PROMISE, DESCRIPTION OF PRODUCT OF USE OR SAMPLE OR MODEL SHALL CREATE ANY WARRANTY FROM MANUFACTURER, UNLESS SIGNED BY THE PRESIDENT OF THE MANUFACTURER. These products are not manufactured, sold or intended for personal, family or household purposes. VAL-MATIC VALVE AND MANUFACTURING CORP. 905 Riverside Dr. Elmhurst, IL 60126 Phone (630) 941-7600 Fax (630) 941-8042 www.valmatic.com 6