Control Sequence Number

Similar documents
SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

Spartan Peripheral Devices. TE 256S Thermostat Applications

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

KMC Conquest Controller

Predator Controller Hardware Family

I/O ZONE 560/583 USERS GUIDE

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

Linear Floor Heaters

Table of Contents. Unit Ventilator

Electric Coils. Blower Coils. Product Information

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

BACnet Programmable TEC (PTEC) VAV Chilled Beam with Demand Control Ventilation (CO2) and Floating or Analog Output Owner s Manual

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

BACnet Points for Single Compressor Water-to- Air Heat Pumps With Hot Gas Reheat Utilizing the FX10 Controller

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Contents. Appendix E: LonWorks Protocol Implementation Conformance Statement Document revision history... 47

Table of Contents. WSHP Open v3

TEC3000 Series Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

CONTENTS. Installation Guide. VT7200 Series

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

Johnson Controls Fan Coil Units and Direct Digital Controls

SEQUENCE OF OPERATIONS

FAN POWERED VAV TERMINALS

Room Pressure Monitor Deluxe

KMC Conquest Controller

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

Document # R00

VCM-X Controller Technical Guide

Power and Control Module. Plenum Pressurization - PP1 MANUAL INSTALLATION + SERVICE

Networkable Fan Coil Controller Specification and Installation Instructions

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

Unit Vent for AppController overview and specifications

VCM-X Modular E-BUS Controller Technical Guide

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

Water Source Heat Pump Module Technical Guide

TEC Controller Heat Pump Single Stage. Owner's Manual Building Technologies

Installation and Maintenance Manual IM

Mammoth Water Source Heat Pumps

Factory Packaged Controls. MHGRV-X Controller Field Technical Guide

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

DAP III Zone Master User s Guide

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

APOGEE Heat Pump Controller - Multi-Stage

Introduction. What is the W2W Open controller?

TB7200 Series Communicating Zone Thermostats

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

2017 products.koer.com Page 1 of 14

Application and Instructions for Field Adjustment of the Control (Model FX06) in Digital Control Option D12A, Space Control with Discharge Air Reset

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

TB7300 Series Communicating Fan Coil Thermostats 24 VAC/FOR COMMERCIAL AND LODGING HVAC APPLICATIONS

RNE Modular Controller Technical Guide

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

Fan Coil for AppController overview and specifications

Digital Precise Air Control - DPAC

TC-9102 Applications

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Introduction. What is a VVT Zone controller?

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

Reference Guide for Microprocessor Controller

VCC-X Controller Technical Guide

NCU Mounting Details

Reference Guide for Microprocessor Controller

York 25-Ton VAV Rooftop Unit

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Lynergy Comfort Control SCR Electric Heater Application Guide

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

Sigler Controls Technical Development Program

L SERIES UNITS 505,191M. 4/2006 Supersedes 504,908M

Pioneer Gold Controller Technical Guide. Pioneer Gold Controller Code: Version 1.1 Used with AAON WSHP WV Series Vertical and WH Series Horizontal

1.0 Digital Controller

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

Ramp It Up VAV Ramps and Controller Possiblities

Factory Packaged Controls. MHGRV-X Controller Field Technical Guide

PIR Ready VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications September 1, 2010

CONTROL OPTIONS SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS PEH, PXH, RDH, REH, RXH, SDH & SHH. Horizontal Split System- Models PDH,

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Models available. Features and benefits. Models available with internal humidity sensing Advanced occupancy functions

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

Accuracy by Design Products for the HVAC Professional

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

Electric Duct Heaters. IDHB & IDHC Series

Document # R01

VT8300 Series Installation Guide 24 Vac Low Voltage

CP CP

T7984 A,B,C Electronic Modulating Control Thermostats

I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

Transcription:

R Control Sequence Number DIGITAL CONTROLS 9800 24 VAC HOT MON NOTE 1: 24VAC MUST BE EARTH GROUNDED COOLING INPUT HOT AI4 AI5 AI6 24 VAC POWER ANALOG INPUTS PRICE UMCB 24VAC BINARY OUTPUTS HOT B01 B02 B03 B04 B05 B. O. SWITCHED - MON BO3 - CLOSE BO2 - OPEN TO HW VALVE HEATING INPUT NOTE 4: DO NOT USE THERMOSTAT IF INPUTS ARE USED PRB - OPTIONAL TEMPERATURE MONITORING PROBE PRICE T-STAT/ WIRELESS RECEIVER NOTE 2: T-STAT IS WIRED WITH CAT-5 CABLE WITH MODULAR RJ-45 CONNECTORS. CABLE SUPPLIED WITH T-STAT NOTE 3: SEVERAL T-STAT OPTIONS AVAILABLE (RM SENSOR, DIAL, LCD, MOTION W/ LCD, WIRELESS DIAL) BACnet MS/TP DAISY CHAIN TERMINAL CONNECTIONS 5V AI7 FLASH SENSOR CONTACT THERMISTOR CLOSURE INPUTS SIG T1 T2 AI3 AI8 T-STAT 5VDC LINKER NET A B BACNET MODULAR CABLE CONNECTIONS NET IN NET OUT ONLY DAMPER OUTPUTS OPN CLO FAULT ANALOG OUTS EXPANSION AO1 AO2 AO3 A04 INFO CENTRE STATUS 24VAC 5VDC AO1 - TO ECM SPEED CTRLR (BAS PIN) [1.5 VDC = OFF 2-9 VDC = 0-100% 9-10 VDC = 100%] STANDARD UMCB TERMINAL BOARD DESIGNATIONS HOT - 24 VAC HOT - 24 VAC MON (EARTH GROUND) AI4 - COOLING INPUT FROM BAS AI5 - HEATING INPUT FROM BAS AI6 - AUX ANALOG INPUT AI7 - AUX ANALOG INPUT T1/AI2 - THERMISTOR INPUT T2/AI8 - THERMISTOR INPUT 2 AO1 - FAN OUPUT (0-10 VDC) AO2 - ANALOG HEAT OUTPUT (0-10VDC) AO3 - ANALOG COOL OUTPUT (0-10VDC) AO4 - AUX ANALOG OUTPUT BO1 - FAN BO2 - REHEAT STAGE 1/VALVE OPEN BO3 - REHEAT STAGE 2/VALVE CLOSE BO4 - REHEAT STAGE 3/PWM BO5 - AUX/COOLING BACnet MS/TP DAISY CHAIN CABLES (OPT) LEGEND PRICE NETC35 (RJ-45) - PLENUM CABLE - FIELD WIRED FACTORY ELECTRICAL WIRING FIELD ELECTRICAL WIRING CONTROL GRAPH Sequence of Operation -- Cooling with Modulating Fan; Tristate Heat with Modulating Fan. Cooling: On an increase in space temperature the controller modulates the fan speed to increase the flow of cool air. On an increase in space temperature greater than the cooling proportional band the fan speed is maintained at its pre-selected maximum setting. HW Heat Fan Flow Max. Airflow Air Vol Heating: On a decrease in space temperature the controller modulates the heating valve to increase the heat proportionally to the room demand. The fan speed is modulated to increase the flow of warm air. On an increase in space temperature greater than the heating proportional band the fan speed is maintained at its pre-selected maximum setting. Cool Room Condition Min. Airflow Warm Calibration note: Suitable min and max heating flows must be selected in order to maintain flow through energized electric coils of at least 200 fpm and at least 70 cfm/kw throughout the entire operating range. PROJECT: R ENGINEER: CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: 249560 2009/02/25 UMCB CONTROLS Modulating Fan CLG and HTG TriState Reheat ECM Motor C Copyright E.H.PRICE LIMITED 2010 REV E

R Control Sequence Number DIGITAL CONTROLS 9803 24 VAC HOT MON NOTE 1: 24VAC MUST BE EARTH GROUNDED COOLING INPUT HOT AI4 AI5 AI6 24 VAC POWER ANALOG INPUTS PRICE UMCB 24VAC BINARY OUTPUTS HOT B01 B02 B03 B04 B05 B. O. SWITCHED - MON BO3 - CLOSE BO2 - OPEN TO HW VALVE HEATING INPUT NOTE 4: DO NOT USE THERMOSTAT IF INPUTS ARE USED PRB - OPTIONAL TEMPERATURE MONITORING PROBE PRICE T-STAT/ WIRELESS RECEIVER 5V AI7 SENSOR CONTACT THERMISTOR CLOSURE INPUTS SIG T1 T2 AI3 AI8 T-STAT 5VDC ANALOG OUTS DAMPER OUTPUTS OPN CLO AO1 AO2 AO3 A04 FAULT FIELD WIRED DAISY CHAINED TO LFG/DBV/RFB (MAX 6 PER JACK, MAX 12 PER UMCB) AO1 - TO ECM SPEED CTRLR (BAS PIN) [1.5 VDC = OFF 2-9 VDC = 0-100% 9-10 VDC = 100%] NOTE 2: T-STAT IS WIRED WITH CAT-5 CABLE WITH MODULAR RJ-45 CONNECTORS. CABLE SUPPLIED WITH T-STAT NOTE 3: SEVERAL T-STAT OPTIONS AVAILABLE (RM SENSOR, DIAL, LCD, MOTION W/ LCD, WIRELESS DIAL) FLASH LINKER EXPANSION STANDARD UMCB TERMINAL BOARD DESIGNATIONS HOT - 24 VAC HOT - 24 VAC MON (EARTH GROUND) AI4 - COOLING INPUT FROM BAS AI5 - HEATING INPUT FROM BAS AI6 - AUX ANALOG INPUT AI7 - AUX ANALOG INPUT T1/AI2 - THERMISTOR INPUT T2/AI8 - THERMISTOR INPUT 2 BACnet MS/TP DAISY CHAIN TERMINAL CONNECTIONS NET A B BACNET MODULAR CABLE CONNECTIONS NET IN NET OUT ONLY INFO CENTRE STATUS 24VAC 5VDC AO1 - FAN OUPUT (0-10 VDC) AO2 - ANALOG HEAT OUTPUT (0-10VDC) AO3 - ANALOG COOL OUTPUT (0-10VDC) AO4 - AUX ANALOG OUTPUT BO1 - FAN BO2 - REHEAT STAGE 1/VALVE OPEN BO3 - REHEAT STAGE 2/VALVE CLOSE BO4 - REHEAT STAGE 3/PWM BO5 - AUX/COOLING LEGEND PRICE SUPPLIED C25 (RJ-12) - PLENUM CABLE - FIELD WIRED PRICE NETC35 (RJ-45) - PLENUM CABLE - FIELD WIRED FACTORY ELECTRICAL WIRING FIELD ELECTRICAL WIRING BACnet MS/TP DAISY CHAIN CABLES (OPT) Sequence of Operation -- Plenum Cooling; Tristate Heat with Modulating Fan. On power up the damper will calibrate open to the plenum for 2 minutes. Cooling: On an increase in space temperature, the controller regulates the VAV floor diffuser actuators to increase the flow of cool plenum air. On an increase of space temperature greater than the cooling proportional band, the floor diffusers are maintained at their pre-selected maximum setting. Fan Flow HW Heat CONTROL GRAPH Plenum Air Max. Airflow Air Vol Heating: On a decrease in space temperature, the controller regulates the VAV floor diffuser actuators closed to the plenum. The controller modulates the heating valve to increase the heat proportionally to the room demand while the fan is modulated to increase the flow of warm air. On an increase in space temperature greater than the heating proportional band, the fan speed is maintained at its pre-selected maximum setting. Cool Room Condition Warm Calibration note: Suitable min and max heating flows must be selected in order to maintain flow through energized electric coils of at least 200 fpm and at least 70 cfm/kw throughout the entire operating range. PROJECT: R ENGINEER: CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: 249563 2009/02/25 UMCB CONTROLS VAV Plenum CLG Modulating Fan on Reheat Tristate Reheat ECM Motor C Copyright E.H.PRICE LIMITED 2010 REV E