No previous protocol.

Similar documents
PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room:

PQS Independent type-testing protocol

PQS performance specification

PQS Independent type-testing protocol

PQS performance specification

PQS performance specification

PQS performance specification

TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression Specification reference:

PQS Independent type-testing protocol

PQS performance specification

PQS Independent type-testing protocol

` PQS Independent type-testing protocol

PQS performance specification

PQS performance specification

PQS Independent type-testing protocol

Summer Works Scheme 2010

PQS performance specification

LOG BOOK & CERTIFICATES

PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 8-24 ZONE CONVENTIONAL FIRE ALARM PANEL LOG BOOK & CERTIFICATES

PQS performance specification

PART 3 REQUIREMENTS FOR SPRINKLER SYSTEMS and SPRINKLER INSTALLERS

ISO INTERNATIONAL STANDARD

PQS Independent type-testing protocol

NZQA registered unit standard version 4 Page 1 of 5

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

Memcom Emergency Telephone

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

COMPETENCE. Lead Fire Warden. Standard Title Lead Fire Warden Competence Assessment Standard Lead Fire Warden Competence Assessment Standard

E01: Cold rooms and freezer rooms

LineGuard 2300 Program User Manual (FloBoss 107)

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

SMS GSM Alarm Messenger

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

26 of 128 9/23/2014 9:25 AM

Supplier Handbook. InSinkErator st Street Racine, WI

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

INTERNATIONAL STANDARD

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

Technical standards to support the evolution of technology enabled care services

For Building Managers: outsourcing the maintenance of fire safety and security systems

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

The EN54 Part 2 & 4 Fire System

FINAL DRAFT INTERNATIONAL STANDARD

IE Code IE Competency Title Credit OAC Ref.

USER MANUAL USB Multi-Function Datalogger Model RHT35

A guide to the changes between BS 8418:2010 and BS 8418:2015

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Licensing of FPGA-based Safety Platform RadICS: Case Study

Shipboard incinerators with capacities up to 4000 kw

INDEX INDEX 2 FOREWARD 3 SECTION 1 COMPANY INFORMATION 4 SECTION 2 GRADING AND CERTIFICATION 5 SECTION 3: ADDITIONAL REQUIREMENTS 6 7

Sentient. Downloader Manual D4854

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

IMAS nd Edition Director, United Nations Mine Action Service (UNMAS), DC2 0650, United Nations, New York, NY 10017, USA

3D_ISS. Integrated Software System. User Guide Manual

REAL TIME LABORATORY MONITORING SYSTEM

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

Water Heating UK 14 th May 2016

THX-DL Data Logger USER & INSTALLATION MANUAL V

Fact File 48 Guide to BS EN 54-13:2017 Fire Detection and alarm systems:

Avigilon Control Center 5 System Integration Guide

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Low Temperature Sterilisation ISO 14937

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

SELF PRESERVATION SOCIETY By Jim Creak

Handout Notes Major changes in BS : 2016

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems

Fire detection and alarm

INTERNATIONAL STANDARD

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY

Awarding body monitoring report for: Institute of Legal Executives (ILEX) February 2008 QCA/08/3734

INTERNATIONAL STANDARD

AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL

Memcom + Emergency Telephone

MicroTech Series 200 Centrifugal Chiller

165 Supplements and Amendments to the MSR 165 User Manual

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

DTW Master Specification Section EMCS: Start Up, Verification and Commissioning

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

INTERNATIONAL STANDARD

2. Safety instructions

IN THE MATTER OF THE GRENFELL TOWER PUBLIC INQUIRY OPENING STATEMENT CS STOKES & ASSOCIATES LIMITED

EasyAlarm ELEVATOR LEITRONIC AG

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

SEMSWA s Role in the Land Development Process

GASTEC QA. Approval Requirements 31-2

Avigilon Control Center System Integration Guide

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Architectural and Engineering Specification for a Security Management System. StarNet 2

Transcription:

PQS Quality Assurance protocol WHO/PQS/E06/TR03.VP2.1 Original: English Distribution: General TITLE: Programmable electronic temperature and event logger systems with integral alarm and auto-dialler options Location of installation: < insert details> Name of Employer: <insert details> Product verification protocol: E06/TR03.VP2.1 Applies to specification ref(s): E06/TR03.1 Date of origin: 30 November 2006 Date of last revision: No previous protocol. Contents: 1. Scope:... 1 2. Normative references:... 2 3. Terms and definitions:... 2 4. Applicability:... 2 5. Specification checklist:... 3 5.1 Specification requirements:... 3 5.1.1 Central equipment:... 3 5.1.2 Freezer rooms:... 3 5.1.3 Cold rooms:... 4 5.1.4 Vaccine freezers:... 4 5.1.5 Vaccine refrigerators:... 4 5.2 Criteria for qualification:... 4 6. Quality control checklist:... 5 6.1 Quality control standards:... 5 6.2 Manufacturing quality control checklist:... 5 6.3 Site work quality control checklist:... 5 6.3.1 Pre-completion inspection checklist:... 5 6.3.2 Commissioning tests:... 5 6.3.3 Training:... 5 6.4 Handover dossier:... 6 7. Customer reference checklist:... 6 8. Pre-qualification evaluation:... 6 9. Modified products:... 6 1. Scope: This document sets out a quality assurance protocol for the installation of a programmable electronic temperature and event logger system with integral alarm and auto-dialler options. In conjunction with specification E06/TR03 and verification protocol E06/TR03-VP1 it may be used to specify the system performance requirements and commissioning activities for a vaccine store temperature monitoring installation. The document is intended to cover the stage in the procurement process commencing when an Approved Installer is invited by the Employer to submit a tender offer for the System and ending when the System has been satisfactorily installed and commissioned on site. WHO/PQS/E06/TR03.VP2.1 1 of 6 30 November 2006

Guidance note for specifiers: When preparing the tender documents the system specifier must complete all the entries in this specification enclosed in arrow brackets, e.g. <insert details>. 2. Normative references: ISO 9001: 2000: Quality Management Systems Requirements. WHO Performance Specification for vaccine cold rooms and freezer rooms WHO/PQS/E01/CRFR01.1. WHO/PQS/E06/TH03.1: WHO Performance Specification for programmable electronic temperature and event logger systems with integral alarm and autodialler options. WHO/PQS /E06/TH03.VP1.1: WHO Independent type-testing protocol for programmable electronic temperature and event logger systems with integral alarm and auto-dialler options. 3. Terms and definitions: Approved Installer: A person or organization approved by the Legal Manufacturer or Reseller as a competent installer of the system components and who has been appointed by the Employer to carry out the installation of the System. Employer: The organization that contracts with the Approved Installer to carry out the system installation and commissioning. In writing: means communication by letter, fax or email. Legal Manufacturer: The natural or legal person with responsibility for the design, manufacture, packaging and labelling of a product or device before it is placed on the market under his own name, regardless of whether these operations are carried out by that person himself or on his behalf by a third party. QA: Quality Assurance. QA Assessor: the person or organization appointed by the Employer to assess the suitability of candidate Approved Installers, to evaluate their proposals and to monitor the installation and commissioning of the system on site. Reseller: A commercial entity, licensed to act on behalf of a Legal Manufacturer, and which carries product liability and warranty responsibilities no less onerous than those carried by the Legal Manufacturer. SMS: Short Message Service. System: The programmable electronic temperature and event logger system referred to in this document. 4. Applicability: The QA assessment will be conducted, for and on behalf of the Employer, by a QA Assessor. WHO/PQS/E06/TR03.VP2.1 2 of 6 30 November 2006

5. Specification checklist: 5.1 Specification requirements: The programmable electronic temperature and event logger system is to be designed and installed by the Approved Installer using component elements already pre-qualified by WHO in accordance with PQS specification E06/TR03 and PQS verification protocol E06/TR03-VP1. The System must provide a secure and effective monitoring system for the cold chain equipment listed below, in accordance with the parameters specified in this document: Guidance note for specifiers: The following sections are to be completed by the specifier. In the case of freezer rooms and cold rooms, enter a separate section for each size of room as some system design parameters (e.g. number of sensors) will vary with room size. 5.1.1 Central equipment: PC: - To be supplied by: <Employer/Approved Installer>. - System parameters to be specified by the Approved Installer. - Location: <specify>. Application software: - To be supplied by the Approved Installer. - Software setup: <specify required format of daily/weekly/monthly reports>. Base station: - Number of channels: The base station must include sufficient channels to cover all the sensors specified below. - Expansion: <specify an allowance for expansion if required>. - Location: <specify>. Voltage sensor: - A voltage sensor connected to the incoming power supply to the vaccine store <is/is not> required. - Location: Downstream of the standby generator and voltage regulation equipment. - Alarm time lag: <specify>. Alarm: - Type: <sounder/flashing light>. - Location(s): <internal/external>. - Number required: <specify>. Auto-dialler: - Landline dialler option: <required/not required>. - SMS text message dialler option: <required/not required>. - Location: <specify>. 5.1.2 Freezer rooms: Temperature range: -15 C to -25 C. Room size: <state dimensions or internal volume>. WHO/PQS/E06/TR03.VP2.1 3 of 6 30 November 2006

Number of temperature sensors: <specify>. Number of rooms of this size: <specify>. 5.1.3 Cold rooms: Temperature range: +2 C to +8 C. Room size: <state dimensions or internal volume>. Number of temperature sensors: <specify>. Number of rooms of this size: <specify>. 5.1.4 Vaccine freezers: Temperature range: -15 C to -25 C. Number of temperature sensors per freezer: <specify>. Number of freezers: <specify>. 5.1.5 Vaccine refrigerators: Temperature range: +2 C to +8 C. Number of temperature sensors per freezer: <specify>. Number of refrigerators: <specify>. 5.2 Criteria for qualification: A system offered by an Approved Installer will be considered for acceptance by the Employer provided: All the specification requirements listed in Section 5.1 are included in the offer. The Approved Installer is ISO 9001 certified. The Approved Installer provides documentary evidence with his tender offer showing that he has been approved by the Legal Manufacturer or Reseller as a competent installer of the system components. The Approved Installer provides a minimum of three recent customer references as specified in clause 7.1. WHO/PQS/E06/TR03.VP2.1 4 of 6 30 November 2006

6. Quality control checklist: 6.1 Quality control standards: ISO 9001: 2000. Documentary evidence of certification is to be supplied by the Approved Installer. 6.2 Manufacturing quality control checklist: On-site inspection of the production facility is not required. 6.3 Site work quality control checklist: The QA Assessor will carry out an inspection of the completed installation and will witness the commissioning tests specified below. The Employer will only accept the System after the QA Assessor has confirmed that the installation is satisfactory. 6.3.1 Pre-completion inspection checklist: Check all system components are in place. Check all temperature sensors are correctly located. Check all system components have been positioned so that they can be routinely and safely maintained. Check that no system components are exposed to the weather or to other environmental conditions for which they are not designed 1. Check all system wiring is satisfactory and properly protected against damage. Check all system components are functioning. Check all temperature sensor alarm settings and time lags are correct. Check all door-open sensor alarm time lags are correct. Check that voltage sensor alarm time lag is correct. Check that software reporting formats are correct. Acceptance criteria: All checks 100% satisfactory. 6.3.2 Commissioning tests: Run test: Run the system for 24 hours. Print off a full set of reports and check that these are satisfactory. High alarm test: Trigger a high alarm in 50% of the temperature sensors. Check that both the alarm and the auto-dialler are correctly activated in every instance. Low alarm test: Trigger a low alarm in 50% of the temperature sensors. Check that both the alarm and the auto-dialler are correctly activated in every instance. Door-open sensor test: Trigger an alarm in 50% of the door-open sensors. Check that both the alarm and the auto-dialler are correctly activated in every instance. Voltage sensor test: Trigger a power failure. Check that both the alarm and the auto-dialler are correctly activated in every instance. Auto-dialler test: Fully test the auto-dialler to ensure that all programmed numbers are dialled and that messages are received. Acceptance criteria: Zero failure rate on all tests. 6.3.3 Training: The Approved Installer must prepare and administer a training course for the users of the system. The training course material must be 1 For example an internally rated alarm sounder mounted externally. WHO/PQS/E06/TR03.VP2.1 5 of 6 30 November 2006

presented in Microsoft PowerPoint in a language understood by all those attending the course. The syllabus must cover the following topics: Introduction to the system and its component parts. Periodic maintenance requirements: including cleaning, battery changing, etc. With hands-on demonstrations. Hardware operation: including system activation, cancelling alarms, etc. With hands-on demonstrations. Report generation and printing. With hands-on demonstrations. System administrator software operations: including maintaining system security and setting passwords, setting logging intervals, setting alarm thresholds, setting alarm delays, changing phone numbers on the autodialler, etc. 6.4 Handover dossier: A handover dossier must be issued after all inspections, testing and training have satisfactorily been completed. The dossier must be presented in a lever arch folder with clearly marked subject dividers and must contain the following: Completed pre-completion checklist together with QA Assessor s observations. Results of commissioning tests together with QA Assessor s observations. Print-out of training course materials. CD of the training course materials. One set of as-installed drawings prepared by the Approved Installer. The drawings must include a detailed wiring diagram which clearly identifies the connections to and the location of all system components. One complete set of user documentation and maintenance instructions, prepared by the Approved Installer. 7. Customer reference checklist: Not applicable. 8. Pre-qualification evaluation: Refer to WHO/PQS /E06/TH03.VP1.1. 9. Modified products: Not applicable. Revision history: Date Change summary Reason for change Approved 21 Sep 06 6.3.1: and safely added. 6.4: additional text. Square brackets removed. Final corrections. UK (30 November 2006 - PQS secretariat) WHO/PQS/E06/TR03.VP2.1 6 of 6 30 November 2006