BlueBox 1200 RORS. Operating manual PURE WATER ANYTIME ANYWHERE

Similar documents
UV Lamp and Quartz Sleeve Replacement/Maintenance

Instruction Sheet DANGER

Instruction Sheet DANGER

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

1020 Industrial Drive, Orlinda, TN fax

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

Owner s Manual. Model: Powered by. D4 Validated Models: D4-V _RevAC

Owner s Manual. Ultraviolet Water Purification System. Pro Series (Pro10, Pro20 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J)

Owner s Manual. Ultraviolet Water Purification System S80, SM80, SV50

Owner s Manual. DO NOT REMOVE FROM UNIT See back cover for vital records

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Ultraviolet Water Sterilizer Installation and Maintenance Manual

GROWMAX WATER Perfect Water for Plants and Gardens

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

SLT-Series Installation and maintenance instructions

Water Distillation System Instruction Manual Nutriteam TC-501

User Instructions. Visit us at us at RB5, RB10, RB15 Maple Sap Buckets

Ultraviolet (UV) Water Treatment System

26/06/2018 USER MANUAL HOBBY 100 GPH REVERSE OSMOSIS. All Rights reserved Les Équipements d Érablière CDL inc.

Installation & Operating Guide

ADVANCE Ultraviolet (UV) Water Treatment System

BEFORE OPERATING THE MACHINE: WARNING

26/06/2018 USER MANUAL OSMOSE HOBBY GPH. All rights reserved Les Équipements d Érablière CDL inc.

EXTREME 1 Reverse Osmosis System

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

EXTREME HP-1 Reverse Osmosis System

ALL-IN-ONE SF PF312 MAR PMAX All-In-One Instructions.indd 1 3/1/2017 9:20 AM

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

EXTREME HC-2 Reverse Osmosis System

Dehumidifier. Instruction Manual. Model DH-320/A

EXTREME 2 Reverse Osmosis System

WL380 QUICK START GUIDE

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

AQUA ONE. Reverse Osmosis System Model ARO5000. Installation and Service Guide PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

1 L Rotary Vacuum Evaporator Instruction Manual

Installation & Operating Guide

Next Generation Corona Discharge Installation & Operation Manual

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

Installation & Service Guide

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

EXTREME 4 Reverse Osmosis System

SimplyClear Pressurized Filter Product Manual

INSTALLATION & MAINTENANCE

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

User s Manual. Purity In Each Drop. Latest RO+UV technology Now at your home

UF424 and UN324. Technical Service

BACK WASH INSIDE THE SPA

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

Ultraviolet (UV) Disinfection System Model RC8

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

I N S T R U C T I O N S

Gallery Electric Fireplaces

User s Information Manual

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5068

hp Dust Collector With Vacuum Attachment

Owner s Manual. Model: Powered by. D4, E4, F4 + Models: D4+, E4+, F4+, E4-50+, F4-50+ Validated Models: D4-V, E4-V, F4-V D4-V+, E4-V+, F4-V+

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

Model CWA200 Owner s Manual

Ultraviolet Disinfection Unit Installation and Owners Manual

30-pint Dehumidifier User Guide

SERVICE REQUIREMENTS

K 3.97 M. Specifications or visit our website: In USA call: Part No

AllClear G2 Series Pressurized Filters Product Manual

Operating Instructions

Hand Dryer Installation & User Manual

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Contents. For your safety About your product Installing your appliance Using your appliance Care & cleaning...

SOLUS-500 EXTRACTOR 120V

16 OUTDOOR MISTING FAN

INSTANT HOT WATER DISPENSER

Model K 520 M Part No

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

gamma pond Ultraviolet Sterilizers

EXTREME HC-4 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT Tel:

Model K 330 M Part No

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

Owner s Manual. Models: Plus Models: PRO Models: Powered by H, K H+, K+ PRO10, PRO20, PRO30, PRO _RevAB

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

Welcome! Today s topic: Small Home Repairs. November 14, 2015

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

O p e r a t i n g I n s t r u c t i o n s

Transcription:

BlueBox 1200 RORS Operating manual PURE WATER ANYTIME ANYWHERE

BlueBox 1200 RORS Post-chlorination and UV-disinfection features 2 PURE WATER ANYTIME ANYWHERE

RFLUSH WATE RFLUSH WATE RAW WATER INLET PART 1 BEFORE USING THE BLUEBOX ill. 1 1 Affix the three coupling hoses on the outside of the container. OUTLET CLEAN WATER ill. 2 2 Press red blue and black hoses onto the quick couplings. Follow the colour codes: Red sign = red hose Blue sign = blue hose Black sign = black hose Flush water outlet (Red hose) OUTLET RAW WATER INLET CLEAN WATER Raw water inlet (Black hose) Clean water outlet (Blue hose) 3 Prepare the floating device. The floating position can be adjusted with water. The more water, the deeper it will sink. ill. 3 4 Affix the float filter as shown. ill. 4 3

RFLUSH WATE RAW WATER INLET PART 2 STARTING THE BLUEBOX (electrical version) 1 Mount correct electrical plug to the supplied mains wire. Connect the unit to a 230 V power supply. OUTLET CLEAN WATER ill. 5 Pressure valve 2 Before starting the pump, the blue pressure valve must be opened by turning it all the way counter-clockwise. IMPORTANT The BlueBox must not be started with pressure on. ill. 6 3 Turn the black power switch clockwise to the ON position. Electrical cabinet START STOP Main Power Switch On ill. 7 4 Start the pump by pressing the green start button. Electrical cabinet START STOP Start Main Power Switch ill. 8 4

RFLUSH WATE 5 Let the pump run for 1-2 minutes until no more bubbles are detected from the red hose. Pressure valve 6 Turn the blue pressure valve clockwise until pressure is approximately 8 bars. ill. 9 7 Open the grey electrical cabinet and check that the UV display unit is active and that the display shows the number of days left. 365 Electrical cabinet Air filter The UV light must be changed after 365 days of operation. Please see maintenance section. ill. 10 UV display ill. 11 8 Non-potable (not suitable for drinking) water will come out of the red hose (Flush water outlet). OUTLET Drinking water can be tapped from the blue hose (Clean water). Flush water outlet (Red hose) RAW WATER INLET CLEAN WATER The flow meter shows the volume of clean water. Raw water inlet (Black hose) Clean water outlet (Blue hose) Wait 3-5 minutes WARNING! Never drink the water from the blue fresh-water tube before the BlueBox has been working for at least 3-5 minutes! 5

PART 3 AFTER USING BLUEBOX (electrical version) 1 Carefully turn the blue pressure valve counter-clockwise until the pressure reads 0 bar. 0 bars ill. 12 2 Drain the system fully by opening the drain valve, situated at the bottom of the BlueBox unit, next to the electrical cabinet. Drain valve START STOP Main Power Switch Run the BlueBox for 1 minute without pressure and without feed water intake. ill. 13 3 Stop the pump by pressing the red Stop button. Electrical cabinet Close the drain valve. START STOP Stop Main Power Switch ill. 14 4 Turn the black switch counterclockwise to turn off the BlueBox. Electrical cabinet START STOP WARNING! Never stop the BlueBox with pressure on. ill. 15 Main Power Switch Off 6

PART 4 MAINTENANCE Daily 1 Cleaning of the float-filter: Screw off the red balloon and plastic top. Remove the nylon and metal filters. Rinse them in clean water with a brush. Insert the filters and check that the crude filter is placed on top. ill. 16 2 Cleaning of the three filters cartridges: a) Unmount the three cylinders containing the filters. ill. 17 b) Remove the filter from the housing and rinse both with clean water. IMPORTANT The filters must NOT be wrought or squeezed. ill. 18 3 Reinstall the used or new filter cartridges in the housings and mount back onto the corresponding bracket. 4 The filters should be changed when plant pressure is becoming too high or when they are judged to being too dirty. Max. 6 months operating time. 5 The air filter mounted in the door of the electrical cabinet must be inspected every day ensuring the filter is not clocked. 7

RFLUSH WATE EVERY WEEK Lubrication of the pump The pump is lubricated with grease at the indicated area. Remove the black plug on the front of the BlueBox to reach the grease point. Be generous. We recommend 3-4 squeezes with a grease tool (you cannot overgrease the pump). Some grease might run out of the pump if it is full, but this is not damaging to the pump or the purifier. OUTLET RAW WATER INLET CLEAN WATER EVERY MONTH Check that all the connections and clamps are tightened correctly. Ensure that filters cartridges, membranes and UV-light bulb are fittet correctly. Check that the drainage pipes in the container are not blocked. Check all hoses for holes, tears and other signs of damage and water leakage. Check the pump s membrane. If there is water leaking out of the small hole at the bottom of the pump, the membrane is not watertight and must be changed. ill. 19 Plug for grease lubrication EVERY YEAR We recommend that the UV glass tube is removed from the chamber and cleaned using a damp cloth infused with a solution of a mild cleaning agent. PUMP MAINTENANCE The membranes must be renewed once a year. 1 Remove the two bolts on top of the motor and replace filter. 2 Remove the four bolts either side of each cylinder and replace filter. 3 Assemble in reverse order. 1 2 ill. 20 ill. 21 IMPORTANT The BlueBox 1200RORS must be started every 3 months in order to maintain flexibility in rubber parts and to avoid build up of contaminants. 8

PART 5 CLEANING After more than 14 days of standstill and before storing, the BlueBox 1200 must undergo a complete cleaning process. Please ensure that you have approximately 200 litres of clean water available before you start the cleaning process. Cleaning procedure with Sodium Hydroxide and Nitric Acid (For example RoClean P303 and RoClean P111) 1 Remove the three filter housings and pull out the filter cartridges. Mount the filter housings back onto the mounts without the filters in. ill. 22 2 Acid Cleaning (RoClean P303) Dilute 1 kg of RoClean P303 in 50 litres of water. Insert all three hoses into the container with the cleaning fluid (Flush water outlet, Raw water inlet and Clean water). Start the BlueBox and let the system rinse without pressure (open the blue pressure valve) for 10 minutes. 3 Turn the blue pressure valve clockwise to show approximately 8 bars of operating pressure. Run the BlueBox at this setting for 30 minutes. 4 Open the pressure valve all the way and run the system with clean water for 10 minutes without pressure, and then again for 10 minutes with 8 bars of pressure. 5 Alkali cleaning (RoClean P111) Dilute 1 kg of RoClean P101 in 50 litres of water. Insert all three hoses into the container with the cleaning fluid (Flush water outlet, Raw water inlet and Clean water). 6 Start the BlueBox and let the system rinse without pressure (open the blue pressure valve) for 10 minutes. 7 Turn the blue pressure valve clockwise to show approximately 8 bars of operating pressure. Run the BlueBox at this setting for 30 minutes. 8 Open the pressure valve all the way and run the system with clean water for 15 minutes without pressure, and then again for 15 minutes with 8 bars of pressure. 9 Turn off the BlueBox, following the procedure in PART 3 After using BlueBox. If the first filter, 25 micron, is not too damaged (clogged), it can be rinsed and brushed down and reinstalled. NOTE For a thorough cleaning, please repeat step 2, 3, 6 and 7, 2-3 times and/or let the membranes soak for up to 4 hours. Preservation of membranes during storage or period of stand-still. If the unit is to be stored (not used) for longer than 14 days, the membranes must be treated with a 20 % glycol solution or RoCide preservation mixture, which will also protect it against freezing temperatures. Remember to run a cleaning process of the system before taking into use. IMPORTANT The cleaning fluid must not exceed 45 ºC The ph value of the cleaning fluid must remain within 2-11 ph 9

PART 6 UV-LAMP Potential Hazard Safety Measures UV Exposure Electrical Shock Impalement Hot chamber Cut or ingestion Scald from water Fire Hg Exposure Water leak Never illuminate UV Lamp outside of the UV Chamber. Never look directly at illuminated UV Lamp, even when using protective gear. Always use protective gear, including gloves and UV safety glasses. If accidental exposure occurs, immediately cool affected area and consult physician. Disconnect power to system before performing any maintenance or repair. There may be more than one source of power. Never perform any physical inspection, repair or maintenance on UV Chamber unless UV chamber has been isolated and depressurized. Never service UV Lamps, Sleeves or associated hardware until depressurization of UV chamber has been confirmed. Allow UV Lamps, UV Chamber to cool for a minimum of 10 minutes before handling. Ensure the quartz sleeve or lamp is not broken, cracked or damaged in any way when handling equipment. When there is no water flow, the water in the chamber will become hot. To prevent scalding, allow the system to cool before draining the system. Do not store any combustible or flammable material close to the system. The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for the removal and disposal of mercury waste. Use proper plumbing materials to avoid potential material degradation from UV exposure. Symptom Possible cause Possible solution No power GFCI or breaker repeatedly trips GFCI and/or breaker tripped. Transient voltage surge suppressor (TVSS) damaged Power supply damaged Connection between lamp and lamp plug is wet Short-circuit in the electrical assembly Reset GFCI and/or breaker Replace TVSS Replace power supply and use a TVSS Clean and dry lamp pins and lamp plug, check unit for leaks or condensation Replace power supply Leak at inlet or outlet Threaded pipe fittings are leaking Clean threads, reseal with Teflon tape and retighten Leak detected from area of UV chamber Leak detected at sensor (if so equipped) Condensation of moist air on cold chamber (slow accumulation) O-ring damaged, deteriorated or incorrectly installed Lamp/sleeve assembly not properly installed (too tight or not tight enough) UV sensor o-rings are damaged, deteriorated, or incorrectly installed Control humidity or relocate unit Inspect and replace if deteriorated Tighten assembly hand-tight Alarm See Display section See Display section System is operating but water tests reveal bacterial contamination Lamp timer does not read anything Equipment downstream of UV system is acting as a breeding ground for pathogens Pathogens are residing in the distribution lines post-uv Recontamination from pipe dead-ends Unit is unplugged No power at AC power outlet Power cord is damaged Power surge caused damage to electrical assembly Inspect and replace o-rings if deteriorated Ensure UV is the last piece of treatment equipment Ensure all distribution lines have been disinfected with chlorine Remove any pipe dead-ends and flush with chlorine Plug unit into AC power outlet Replace fuse or reset breaker Replace power cord Replace power supply and use a surge protector 10

Display Lamp timer display Counts down from 365 days to show time for annual lamp replacement. Lamp timer reset After installing a new lamp, press and hold for five seconds to reset Lamp timer to 365. Alarm Press to silence audible alarm. When the alarm is due to the lamp s age, the mute button will silence the audible alarm for 7 days; this may be repeated up to a maximum of 4 times. After that, the button will silence for only 24 hours. When the alarm is due to any other issue, the mute button will silence the audible alarm for 24 hours. SLEEVE CLEANING & LAMP REPLACEMENT Lamp replacement Unplug the BlueBox from the electrical socket. Let the unit cool for 10 minutes. Remove the UV-lamp from the container. Sleeve cleaning Minerals in the water slowly form a coating on the sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing purification performance. Equipment required Clean cotton Latex or plastic gloves are preferred Scale remover Vinegar or a citrus-based product Cloth Must be soft, lint-free, and chemical-free. No clean-wipes must be used Cotton swab Lamp life The amount of UV light created by the lamp decreases over time, requiring a replacement of the lamp every 12 months. The controller displays the total lamp life remaining in days. At 0 (zero) days, the controller will display A3 and supply an intermittent audible chirp (1 second on, 5 seconds off), indicating the need to change the lamp. NOTE The UV system is designed to operate continuously and should not be shut off for short periods of time, such as over a period of less than three weeks. RESETTING LAMP LIFE 1 Disconnect the lamp from the controller. 2 Hold the RESET button down while reapplying power to the Controller until you see rset on the display, then release. 3 A 5 second delay will occur until your hear an audible tone and the display will once again read 365. 11

SPARE PARTS Please contact info@muchmorewater.com for spare parts Filter cartridges E-XA004823309 Prefilter, 25 micron/19.5 (no.1) BB1200 RORS E-XA004823291 Prefilter, 05 micron/19.5. Melt blown (no.2) BB1200 RORS E-70020146323 Activated Carbon. 7.75 cartridge filter (no.3) 2 pcs per housing = 19.5 RS1200 RORS Filter housing E-70020254895 SS filter housing 20. Fitting Ø 3/4 ACLOW34021 LOW3 4021 RO-Membrane for BB1200RORS VE4021304BSP-BO Stainless Steel vessel 4 for RO-membrane VECEC4BSPCLAMP-BOW Complete endcap for 4 vessel. BSP 1/2 x 1/2 Modul_RO1200 Complete RO-membrane setup on frame UV-disinfection system 14201-9105 UV-light bulb 14201-9205 UV quartz tube Pump parts 750153 Hardi pump 603/7 membrane kit 210022 Bearings type 6205 60207 Bearings type 6007 Membrane rehabilitation detergents 7509846 RoClean P303, High PH cleaning granulate. 7509014 RoClean P111, Low PH cleaning granulate. ROCSC RoCide, preservation granulate mixture. Miscellaneous parts 0001014 Pressure gauge. 16 BAR. Glycol filled 703032 Suction wind chamber 334553 Membrane for suction wind chamber UV quartz tube 14201-9205 Filter cartridge 8944502541 (25µ) 80105410000 (5µ) 871005906 (AC) Float filter 841481 Filter Housing E-70020254895 100 micron filters 165767 UV-light bulb 14201-9105 12

RFLUSH WATE OUTLET RAW WATER INLET CLEAN WATER Flush water outlet (Red hose) DH10008 Raw water inlet (Black hose) DH10009 Clean water outlet (Blue hose) DH10007 Electrical cabinet Suction chamber 703032 START STOP Main Power Switch Membrane (kit of four filters) 750153 365 Bearings 6205 210022 6007 60207 Ballast (UV display) 550910300 Air filter 5712014732 13

If any faults should occur SYMPTOM Pump cannot produce any pressure REASON Float-filter is clogged. Absorption tube is not filled with water. SOLUTION Dismantle red float and clean net-filters with brush (see ill. on page 7) Dismantle black absorption hose and fill with water. Contra vent in absorption tube is stuck. Take apart contra vent and clean inside. Membranes in pump are defective. Vent valves in pump Are defective or clogged. Pump is dismantled by loosing the bolts membranes are loosened and changed. (see Motor maintenance on page 8). Pump is dismantled by loosening bolts and vents are cleaned or changed. Clean water capacity fails UV-light bulb gives no light The pump is letting in air. Check reasons in pump section. The system must undergo a cleaning process. The system is not working at normal work pressure. The lifting height (max. 6 meters) has been exceeded. Clean water tube is blocked or clogged. Plug for light is not connected. UV-light bulb is not connected. Defective bulb. Tubes are tightened on absorption side of pump. Check solutions in pump section. Follow the cleaning guide. (see Part 5, Every month ) Adjust work pressure to 8 bars (see ill.) and check that the manometer on main-block shows 8 bar. The lifting height must be reduced to under 6 meters. Make sure that there is free passage in the blue clean water hose and that the flow meter are not clogged by obstacles. Insert plug. Dismantle UV-housing and tighten bulb in its socket. Change bulb and check if the light housing is tight (avoid looking directly at UV-light for more than a couple of seconds). Beeping noise There is water coming out from the bottom of the pump Transformer is defective. Defective membrane -or membranes. Change transformer, please contact Much More Water A/S or your local distributor for further assistance. Change membrane- or membranes. 14

IMPORTANT NOTE Please be aware of the following: Make sure that the electricity supply is stable. The Reverse Osmosis membranes (RO filters) in the BlueBox system normally have to be changed every 2 years depending on the working hours and quality of feed water. Please do not place the system in directly sunlight. Heat may affect the electronics in the switch board box. As the UV-light contains glass, the system must not be affected by hard shock. The system must be free of dust and dirt. The system must not be exposed for frost. Temperatures below 0 ºC (zero degrees Celsius) can ruin the RO membranes. E.g. during a long-haul flight, the BlueBox should be started with low pressure for a while in order to defrost the membranes without damaging them. For long term storage in freezing temperatures, please contact Much More Water at info@muchmorewater.com. As an industrial standard for Reverse Osmosis, the output of the membranes decreases in proportion with the temperature of the raw water: 3 % reduction per 1 ºC measured from 25 ºC. Beware of silt, humus and high levels of iron in the raw water. These compounds will eventually spoil the membranes, since very small plates from these compounds will fill up the membranes over time. The only way to deal with this is to install an improved pre-filtration system. Beware of high content of iron/manganese. Especially coming from boreholes, high levels of iron and manganese will clog the membranes and render them useless. It may be advisable to install an improved pre-filtration system, using anti-scalants. 15

PURE WATER ANYTIME ANYWHERE Much More Water A/S Staerkendevej 43 DK-4000 Roskilde phone: +45 8020 8020 info@muchmorewater.com www.muchmorewater.com July 2017