USER MANUAL 10 YEAR LIFE SMOKE ALARM

Wireless Interlink Smoke Alarm + 10 Year Life

Wireless Base Remote Test and Hush

1 Introducing Eve Smoke

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

Datasheet CALYPSO II R. Interlinkable smoke alarm device

Heat Alarm. Owner s Manual. Model CFH10. Rate of Rise Temperature Sensing Selectable Fixed Temperature Sensing Proprietary Wireless Connectivity

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

169MHz Telecare Devices Carbon Monoxide Detector

NG-9B NATURAL GAS ALARM

Heat Sensor. Owner s Manual

LIFETONE HL TM. Bedside Fire Alarm & Clock. User s Manual MODEL HLAC XI. RECOMMENDED LOCATIONS FOR SMOKE ALARMS ENGLISH SPANISH

U S E R M A N U A L UBH1RF HEAT ALARM

Smoke Alarm. 120V AC Ionization. Smoke Alarm. Back-up. with 9V Battery

USER S GUIDE. Smoke Alarm. Battery-powered

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

Home Doorway Alert Kit

_V1.qxd:_ :27 AM. Ionisation Sealed Smoke Alarm with Ten Year Lithium Battery & Hush. Manual. Model Q910

Smoke Alarm User Manual

636 and 646 Keypads. User s Manual

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

Smoke Alarm User s Manual

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Smoke Alarm User Manual

Smoke Alarm User s Guide

Photoelectric Smoke Alarm User s Guide

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

SAFEGUARD YOUR HOME WITH QUELL

This Heat Alarm must only be wired to a 240Vac 50Hz sine wave current supply.

_EN_V4:_ :46 AM Page 1 USER S MANUAL 0086-CPD

WIRELESS PHOTOELECTRIC SMOKE ALARM

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

Smoke & Carbon Monoxide Alarms

LOW FREQUENCY SOUNDER

NetworX NX-8V2. LED Keypad User Manual

Wireless Smoke Alarm User s Guide

Air Purification System. CLI-AP10-W Installation & Operating Instructions

Tomorrow s technology for today s security needs.

Smoke Alarm Legislation

Smoke Alarm User Guide

PC56O. Instruction Manual

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

NETWORX TM. User manual NX-4

SMART SMOKE DETECTOR

THUNDER LOW FREQUENCY AMPLIFIER INSTALLATION MANUAL

ONLY WORKING SMOKE ALARMS SAVE LIVES

INSTRUCTION MANUAL PC255O

Protecting you and your home

1. Safety instructions Mounting location in rooms of the heat detectors... 3

INSTALLATION AND USER MANUAL

INSTRUCTION MANUAL PC255O

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Smoke Alarm User s Guide

SMOKE & CARBON MONOXIDE ALARMS

LCD and 16-Zone LED Keypads. User s Manual

Melrose Fire Department

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

COMBUSTIBLE GAS LEAK DETECTOR PEN

Smoke Alarm. Owner s Manual. Model CFS10. Combination Alarm

Installation and user guide

MODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS

SECURITY SYSTEM NOTES

GT-1D. Residential/Tenant Station OPERATION MANUAL

abode Web app Functionality

10-Zone Spectra LED Keypads

Invensys Controls Americas

Carbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings

Smoke Alarms and Carbon Monoxide Alarms

120V AC Smoke Alarm with 9V Battery Back-up

Consumer Products Catalog

Fire Command Keypad. XR5 User s Guide

Home Fire Safety. Protect what you value! Escape Plans. Smoke Alarms. Child Safety. Involve all your family. Get them all out alive

SPECTRA 1727 USER S GUIDE

OWNER'S MANUAL PLEASE READ AND SAVE!

Watchguard Fire and Theft

RMS-I-DE-01 Smoke Detector

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

INSTALLATION AND USER MANUAL

Smoke alarm Installer s Manual

NX-148 LCD CODE PAD TABLE OF CONTENTS

External Wireless Sounder

Multi Line Laser Level Model: L203

Approved Document for New Zealand Building Code Warning Systems Clause F7 Third Edition

MK9 series CarePhone. Installers Mauual

Curved Metal Panel Heater

OPERATION & MAINTENANCE INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz

MANUAL BOOK Sensor faucet

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

Smoke Alarm User s Guide

Smoke Alarm User s Guide

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

Transcription:

PLEASE READ THIS USER GUIDE CAREFULLY

Cavius DIY Heat Alarm Model 3002-TK001 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. For large text option and maintenance guide visit www.cavius.co.nz/downloads www.cavius.com.au/downloads 1.

MOUNTING BASE The CAVIUS Thermal Heat Alarm is designed for areas where a fire will be more flame and heat than smoke; areas such as kitchens, garages, laundries and workshops. This device is activated when it senses a rapid increase in room temperature. Tested to comply to the standard of system heat alarms EN54-5 class A1/R. TEST/ HUSH BUTTON ALARM AUDIBLE ALERT 2. 3.

The best locations in your home to install the heat alarm: Kitchen area Living room with wooden stove burner Garage area Washing and drying area. Additional heat alarms will increase the security. The NZ and Australian Fire Services recommend heat and smoke alarms in every bedroom, hallway and living area for early fire detection. Installation of heat alarm: Info: The label in the product must not be removed due to important information regarding the product. 1. The heat alarm is not in the mounting base when purchased. Use the mounting base ring to mark the screw holes on the ceiling. Use the enclosed screws and plugs for installing the mounting base. MARK UP SCREW HOLES WITH A PEN 4. 5.

USE THE ENCLOSED SCREWS AND PLUGS FOR INSTALLATION Placement: Designed for placement on the ceiling in the centre of the room it is fitted in. Never install directly above the oven/hob/stove. The heat alarm should be a minimum 50 cm from the wall. CLICK THE HEAT ALARM FIRMLY INTO THE BASE TO ACTIVATE MINIMUM 50cm FROM WALL CEILING 50cm WALL 6. 7.

2. Mount the heat alarm to the base by using the smart clip-on-ceiling mechanism. After mounting, test the heat alarm by pushing the test button on the side and get an alarm signal. Heat alarm signal: The heat alarms have a visual and acoustic signal. In the passive state, the LED will flash every 48 seconds to indicate normal function. In alarming state the LED will flash and the alarm will emit a sweeping sound pattern designed to alert occupants. 8. 9.

Hush function: In case of unintentional or false alarms, hold the side hush button for 2 seconds. This will mute the alarm for 10 minutes, after which time the alarm will automatically resume its normal function. Maintenance: Test the heat alarm once per month by pushing the side test button. The heat alarm should produce a loud alarm tone. Place the heat alarm where it is reachable in order to test the battery and complete maintenance. Disposal: For battery and product, please dispose properly at end of life. This is electronic waste that should be recycled. Other information: Do not paint the heat alarm. If the heat alarm does not work when the test button is pushed, please check our Trouble Shooting Guides at: www.cavius.co.nz and www.cavius.com.au 10. 11.

FUNCTIONAL INFORMATION Type of alarm: Cavius heat alarm detects rapidly increased temperature level and absolute heat level. Alarm signal: Heat alarm activation is indicated by a series of repeated tones. The minimum sounds level is 85 db at 3 metres. Battery: Powered by a non-replaceable 3v CR123 A DURACELL Lithium battery with 10-year life (included). Low battery indicator: A short acoustic beep will sound and the LED will flash every 48 seconds when the battery is near the end of its life. In this stage it will continue for minimum 30 days. You must change the heat alarm after 10 years usage, or if the heat alarm has suffered any damage. The heat alarm is not active unless it is inserted in the mounting base. Always test the heat alarm after inserting into the mounting base, allow 5 seconds before testing. 12. 13.

MANUFACTURED BY: Aps Julsøvej 16 - DK8600 Silkeborg www.cavius.com - info@cavius.com Manufactured in P.R.C. DISTRIBUTOR INFORMATION: CAVIUS Nano Ltd. 2G Ashley Place, Papamoa, Bay Of Plenty 3118. P.O Box 11241, Palm Beach Plaza, Papamoa, Bay Of Plenty 3151, New Zealand. www.cavius.co.nz Hotline: 0800 766533 or 07 542 2191 REP ELEC. Locked Bag 45, Plumpton, NSW 2761, Australia. www.cavius.com.au - PH: 1300 555 586 Warranty: Your CAVIUS heat alarm has a 5 year warranty from the date of purchase against defect in material and workmanship. Faulty units during this period can be returned to the place of purchase. You must provide the proof of purchase date and such defects will be repaired, or replaced at the distributors option, without charge. This Warranty only covers defects in materials or workmanship in normal residential use and does not cover damage resulting from negligent handling, misuse or lack of reasonable care. This warranty is in lieu of any other warranty either expressed or implied. EN54-5 CLASS A1/R Product Number: 3002-TK001 14. 126554 rev1 15.

Essential certified characteristics: Type of mounting Main power supply Battery duration Ceiling only Internal power source (battery included) 10 years Interconnectable device Yes No Suitable for installation in mobile home Yes No Connection to external auxiliary devices Yes No Radio link Yes No Individual alarm indicator Yes No Alarm silence facility (10min) Yes No No radioactivity infrared technology Yes No Accessibility option Yes No 16. 17.