ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

Similar documents
Installation, Operating and Maintenance Manual

TCM-2 Thyristor Control Module DATA SHEET

AO Annunciator Module

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

AL800ULADA. NAC Power Extender. Installation Guide

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

Installation and user manual for the BiWire / Conventional Repeater Panel

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A

Instructions for the fan motor control system with integrated wiring terminals SILVER C

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

SP-1000X. Panic Device Power Controller Installation Guide. Rev

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Quickheat 30 weather compensated boiler control

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HOME AUTOMATION GUIDE TO THE HOME AUTOMATION SYSTEM

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Application, Installation, Operation & Maintenance Manual

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Installation Guide for models:

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

M2500 Engine Controller Installation Manual

Pioneer-R16 Gas Monitor Operator s Manual

Emerald 3000 MK3 GJD010 Lighting Controller

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Remote NAC Power Supply D7038

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

Installation Manual Premier 412/816/832. Issue 10

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

STATUS ALARM HISTORY ALARM RESET

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Smoke Vent Control Panel PCB4 V4 Installation Manual

General Purpose IO Technical Manual

TECHNICAL DATA OBSOLETE

Conventional Fire Alarm System 2014 V1.2

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Ethernet General Purpose

Door Release Power Supply

Installation Guide for models:

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Interface and EOL Modules 8

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Natural Ventilation Controller with 24vDC drive NVC-1204

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Operating Instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Technical Manual. Level Alarm Unit CARLA & WIDS

Alarm Tone Generator Model AG17

4 in 1 Digital Thermostat Control

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Model 4001 Series Single Channel Controller

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

30.45 Electric Release PDRP-2001

AL600ULADA. NAC Power Extender. Installation Guide

ECO N DATE DESCRIPTION OF CHANGE CHG

ISIS SAFETY SYSTEM Installation guide

OPERATION AND INSTALLATION MANUAL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Section 1 General Description

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

ESP TECHNOLOGIES LIMITED

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Touch Screen 1 loop Addressable Fire Alarm Panel

SECTION LOW VOLTAGE LIGHTING CONTROLS

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

IGD.CO.UK

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

WIO200 Water In Oil measuring instrument

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

The EN54 Part 2 & 4 Fire System

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

Sensor Interface Module Installation/Operation Instructions

Software Version 2.01 LEVEL MONITOR MODEL 220

Constant voltage 3-phase rectifier.

Model 4880 Status Output Display Module Manual

Transcription:

ELECTROPROJECT POWER SUPPLY FOR DOOR MAGNETS Innovative and carefully thought out Always the right drive

ELECTROPROJECT AANDRIJFTECHNIEK ElectroProject has evolved over the last 75 years from a technical trade and engineering firm to an innovative partner for complex technical systems and market segment related components. Since the 60s, the magnet systems have been added to the product range. This is done in close collaboration with producer and global market leader Kendrion. Kendrion-Hahn supplies ElectroProject with a complete range of door and locking magnets for the Fire and Security market and industrial magnets for industry and the OEM market. Over 40 years ago, ElectroProject added the 24 Vdc GTV power supply. This allows us to offer a complete door retention system at a best price/performance ratio. Application of the stabilised 24 Vdc power supply General: You want to protect your property against fire, burglary and unwanted visitors. At the same time you want to make your entrances and doorways as accessible as possible to your staff. ElectroProject provides 24 Vdc power supplies up to 10 amps with and without back-up battery for supplying power to door retention and/or door locking systems. The power supplies can be controlled by a Fire Alarm Control Panel (FACP), a card reader or other signalling devices (). In emergencies, the power supply is switched off, the emergency exit doors are unlocked and the partitioning doors are closed. Smoke or heat detector Smoke or heat detector Implementation The power supply provides, with its three inputs, two independent switch outputs and 5 program choices, a very interesting solution for the controlling and switching off of almost any door retention system. Door closer The can be controlled by a floating control contact and/or a 24 Vdc control signal. The test button on the unit can be switched off using a jumper setting on the control board. The has as a standard, 2 isolated contacts that can be used, for example, for feedback on the status of the GTV 2 outputs and a Master/Slave output for the simultaneous controlling of multiple GTV's. Power supply 230 Vac Push button "close door" Door magnet Example Stand-alone smoke detectors application 2

Principle of the The supplies a stabilised and steady 24 Vdc power supply. The ripple voltage is less than 1%. The input voltage may vary between 180 to 240 Volts (50/60 Hz). The output voltage is set to 25 Vdc to compensate for the to be expected voltage loss due to the use of long cables. The can be used for the following: Door magnets, electric door closers and/or electric locks, A load which has to be split over one or two outputs (zones) which have to be closed independently of each other. Closing sequence system for two closing doors opposite each other, Door magnets with separate orientation (LED) lighting, Locking magnets with separate power supply for position indication, Stand-alone smoke detectors. Characteristics of the power supply unit: Selector switch with five fixed choice programs, Three inputs and two switched outputs, Backwards compatible with the previous GTV and GTVS models, The outputs are short-circuit proof with automatic over-current detection, Models up to 10 Amps 24 Vdc stabilised and steady (<1%), DIN-rail mounting space for optional installation of an I/O module FACP, timer switch; main switch and dimmer switch, for example, Fixed 24 Vdc auxiliary voltage for items like light signalling or controlled power supply, Large and easily accessible connection terminals, Cable entry via cable glands at the top and bottom of the unit, Control of all inputs and outputs via status LEDs on the PCB, Option to select manual or automatic start after reset of fire alarm/ contact, Master/Slave function which allows several units to be controlled. Presets The has a test program and four pre-programmed programs that, depending on the program selected, configure the two outputs of the. Setting the function switch The function switch is on the control board and is used for setting programs 0 to 8, The power turns ON automatically in function modes 1 to 4, The power turns ON manually in function modes 5 to 8, By using the push button (DK) you can turn the power back OFF and ON again. 3

ExAMPLE of applications The has four pre-programmed drivers and a test program which can be selected by setting the function switch on the control board of the. This allows you to apply it to numerous systems. A number of application examples have been listed below. A comprehensive description of the programs can be found in the instruction manual of the Control Power Load 0 1 zone, all door magnets controlled by push button 1 1 zone, all door magnets controlled by FACP 2 1 zone, door magnets with closing sequence control Part load slows down gradually (6 seconds) 3 2 zones, zone 1: door magnets left corridor 2 zones, zone 2: door magnets right corridor 4 2 zones, zone 1: all door magnets 2 zones, zone 2: all emergency door locking magnets Special safety shut off for zone 2 * Control via FACP (Fire Alarm Control Panel) or system (Building Management System)

models 25 Operating voltage 230V/50Hz Secondary voltage 24 Vdc Secondary current 1 A Secondary capacity 25 W Ripple DC < 1% Weight 4.5 KG Dimensions (HxWxD) 250x250x120 mm Protection rating IP 44 50 Operating voltage 230V/50Hz. Secondary voltage 24 Vdc Secondary current 2 A Secondary capacity 50 W Ripple DC < 1% Weight 5 KG Dimensions (HxWxD) 250x300x120 mm Protection rating IP 44 100 Operating voltage 230V/50Hz Secondary voltage 24 Vdc Secondary current 4 A. Secondary capacity 100 W Ripple DC < 1% Weight 5.5 KG Dimensions (HxWxD) 250x300x120 mm Protection rating IP 44 250 Operating voltage 230V/50Hz Secondary voltage 24 Vdc Secondary current 10 A Secondary capacity 250 W Ripple DC < 1% Weight 7 KG Dimensions (HxWxD) 250x400x150 mm Protection rating IP 21 5

options LED push button Illuminated (LED) recessed push button. To replace the existing push button on the power supply. Equipped with cable connector. Function LED voltage Implementation Pulse function (model) 24 Vdc Complete 200 mm cable connector Universal control board Universal control board No. E12010 for replacement purposes Suitable for all models. Service DISPLAY double line service display for reading and checking of: The output voltage. The output current per output, The total current for both outputs. The correct operation of the function switch and jumpers for current limiting, The logical state of the test push button on the door, Error message current limit. Dimensions Weight 100x60x20mm 60 gram Timer switch Digital 1-channel timer switch for DIN rail mounting with day and week program, and 600 hours reserve power. Analogue 1-channel timer switch for DIN rail mounting with day program and 70 hours reserve power. Manufacturer Finder. 6

wiring DIAGRAM Emergency Contacts 1 2 3 4 Output I Output II POWER ON Function LED A LED B LED C +24V Input A +24V Input B +24V Input C F1 SW2 GND SW1 Reset +24V Master Out +24V Max. 400mA LED I LED II Fuse F1: F500mA/250V/5x20mm + - + - 1 2 3 4 5 6 7 8 9 10 1 2 3 4 GND LED I/II 24Vdc Output Group I Jumper Group I/II Output On Overload Tripped 24Vdc Output Group II CN8 The inputs A, B and C are used to connect external control signals. Via the Emergency Contacts the controlling device can get a status message returned. The Master output (terminals 7 and 8) is used to control other power supplies. (see wiring diagram in the instruction manual) Input A Input B Input C * Jumper wire if input is not used + - 24Vdc Load Group I + - 24Vdc Load Group II Loads needing 24V continuously can be connected to terminal 9 (+24V) and terminal 10 (GND). The current in this output must never exceed 400 ma. Technical specifications Type description power supply unit Manufacturer: ElectroProject Aandrijftechniek Primary voltage: 180-240 Vac (47/63Hz 1 phase) Nominal output voltage: Nominal 24 Vdc, 25 Vdc terminal voltage Ripple voltage and noise: < 1% Nominal output current: Depending on type, maximum 1,2, 4, 10 Amp max. Output power rating: Depending on type, maximum 25, 50, 100 or 250 Watt Short-circuit proof: Yes Protected against overload: Yes Efficiency: > 86% (at full load) Power failure override time: Depending on type 28-60 ms 7

För mer info kontakta: Inkom, Industrikomponenter AB Österögatan 2, SE-164 40 Kista Tel: +46 (0)8-514 84 400 Fax: +46 (0)8-514 84 401 E-post: info@inkom.se Org.nr: 556111-8505 Always the right drive