POINTEK CLS 300 OINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

Similar documents
POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

POINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

Quick Start Manual July pointek CLS100

Instruction Manual December 2001 ENACOCU02

CU-02 with Senaco Plus

Instruction Manual August sitrans CU 02

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Instruction Manual April sitrans AS 100

Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Fisher LCP100 Local Control Panel

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

OilSET-1000 (12 VDC)

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SET-2000 Hi Level/Oil

INTRODUCTION / TABLE OF CONTENTS

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Functional Safety Manual June pointek CLS500/LC500

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Table of Contents. Protective Relays

4 & 8-POINT ANNUNCIATORS Instruction Manual

LC2200 Level Controller Installation and Maintenance Instructions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DB5 Intrinsically Safe Sounder Type DB-5

INTRODUCTION / TABLE OF CONTENTS

Software Version 2.01 LEVEL MONITOR MODEL 220

FLT93 Installation, Operation and Troubleshooting Guide

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

multiranger 100 / 200

SET-2000 Oil/Sludge 12 VDC

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

VERSAFLOW VORTEX Supplementary instructions

1510 Side Mounted Level Switch

IR FLAME DETECTOR RIV-601/F

Snifter ATEX22 VERSION. User Manual. Distributor

Non-Contacting Point Level Detection and Pump Control Sensor. Setting a New World Standard

OPTIBAR DP 7060 Supplementary Instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

INSTRUCTION MANUAL (ATEX / IECEx)

LC3000 Level Controller Installation and Maintenance Instructions

MANUAL Overflow sensor NVF-104/34-PF

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Installation and Operating Instructions

Duct and Rough Service Carbon Monoxide Sensor

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

D3000. Installation & Setup Guide

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SET Installation and Operating Instructions. Level switch for one sensor

Continuous level measurement Ultrasonic transmitters

MODEL B2 INSTALLATION MANUAL

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

Inductive slot sensor

vibration switch

! WARNING. Before using product, read and understand instructions.

VAMP 120 & 121. Arc flash detection units. Product picture

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Product Manual SZ1145

MANUAL Oil Level Sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

OPTISENS TUR 2000 Technical Datasheet

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Certificate of Compliance

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

M5200 Industrial Pressure Transducer

Technical Data. General specifications. Rated operating distance s n 5 mm

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INTRODUCTION / TABLE OF CONTENTS

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

Instructions for the fan motor control system, SILVER C

! WARNING. Before using product, read and understand instructions.

Rosemount 752 Fieldbus Remote Indicator

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

Installation, operation & service manual. AlarmScout 961/962 loop powered

Product Manual SZ1144

Ultrasonic Point Level Switches

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Transcription:

POINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual December 2001 OINTEK CLS 300

Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc. 2000. All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 Email: techpubs@siemens-milltronics.com For the library of SMPI instruction manuals, visit: www.siemens-milltronics.com Siemens Milltronics Process Instruments Inc. 2001

Table of Contents Introduction to the Pointek CLS 300...2 Pointek CLS 300 Outputs...2 Pointek CLS 300 Features...2 Pointek CLS 300 Applications...2 Specifications... 3 Installation... 6 Location...6 Configuration and Dimensions... 7 Standard Version...8 High Temperature Version...9 Rod Version...10 Changing Probe Length...10 Cable... 12 Cable Tensile Strength...13 Cable Weights...13 Shortening the Cable...13 Mounting... 14 Multiple units...14 Wall Restriction...14 Process Cautions...15 Interconnection... 16 Trip Amplifier...16 Relay Output Connection...17 Solid State Switch...17 Diode Protection...17 Ancillary 2-Wire Output Connection...18 Power Connection (3 or 4 wire connection)...18 Operation... 19 Setup...19 Start Up...20 Alarm Output...21 Troubleshooting... 24 Maintenance...24 Appendix I: Application Notes... 25 Application Notes...25 Appendix II: CE Conformity... 26 Index... 27 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 1

Introduction to the Pointek CLS 300 Note: Pointek CLS 300 is to be used only in the manner outlined in this instruction manual. The Pointek CLS 300 capacitance level switch provides output on high or low process material levels. When the measured material is at the desired level, the change in capacitance is sensed and a level alarm is triggered. This could be either a high level alarm (material rising to reach the desired level) or a low level alarm (material falling to reach desired level). Pointek CLS 300 Outputs One form C (SPDT) relay One isolated, non-polarized, solid-state switch Pointek CLS 300 Features NPT, BSPT, JIS (other connections on request) Corrosion resistant construction, PFA, Ceramic, and 316L stainless steel wetted parts 25m (82 ft) maximum insertion length Rugged shear and abrasion resistant probe Fully adjustable process alarm: level, time delay Field adjustable insert length ESD protection to 55 kv continuous discharge Active shield technology Pointek CLS 300 Applications Liquids, slurries, powders, granules, and solids Chemical and petrochemical High pressure and temperature Power Industry (fly-ash) Page 2 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Specifications Probe Process Connections NPT/BSPT/JIS 1 Wetted Parts Standard Version: AISI 316L/PFA/Peek 2 High Temperature Version: AISI 316L/Ceramics Probe Lengths Rod Version: min. 350mm (14") - max. 1000mm (40") Rope/Cable Version: min. 500mm (20") - max. 25000mm (985") Max. Tensile Force 1900kg (4188lbs) Pressure Range 3 Standard Version: High Pressure Version: -1 to +35 barg (-14.6 to +511 psig) -1 to +100 barg (-14.6 to +1460 psig) Temperature Range 3 Standard Version: -40 to 200 C (-40 to 392 F) High Temperature Version: -40 to 400 C (-40 to 752 F) Min. Dielectric Constant (> r ): 1.5 Enclosure Aluminium Epoxy Coated Yes NEMA/CSA/IP-Rating 4/Type4/IP65 Cable Inlet 2 X ½" NPT Certifications CENELEC/FM/CSA 1 2 3 Other process connections available on request. See Probe: Standard on page 5, or Probe: Cable on page 5. For a chemical resistance list for PFA/Peek /Ceramic, contact your local distributor. See the Pressure/Temperature Curve in Appendix I: Application Notes on p. 25. 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 3

Power Supply and Transmitter Supply Voltage 2-250 Vac/dc any polarity galvanically isolated Power consumption 2VA/2Watt Wiring connections Max. 2.5mm 2 Temperature ranges Operation (Storage): -40 to 85 C (-40 to 185 F) Signal indicators Three: Adjustment Potentiometers Two: 1. Adjustment control 2. Output status 3. Power 1. Time delay adjustment 2. Sensitivity adjustment Adjustment Switches 5PST dip switch: time delay select fail safe selection time delay test/adjust high/low sensitivity Min. Sensitivity 1% change in actual capacitance Max. Temperature Drift 0.2% of Actual Capacitance Value Measurement Frequency 600 (khz) max. ESD protection Protected to 55kV continuous discharge Output Functions Relay Contact Contact: Max. Contact Load (dc): Max. Contact Load (ac): Max. Switching Capacity: Min. Contact Load: Time Delay (ON and/or OFF): Solid State switch Output: Safety: Max. Load: Max. Switch Voltage: Max. Load Current: Voltage Drop Time Delay (On and/or Off) Form C (SPDT) (selectable NC or NO contact) 5A/30V dc 8A/250V ac (cosn=1) 150Watt/2000VA 10mA/5Vdc 1-60 sec. Galvanically isolated Non-polarity sensitive transistor 2 Watt 250Vac/300Vdc 100mA Below 1 Volt typical @ 50mA 1-60 sec. Two (2) Wire Switch With customer supplied external trip devices Page 4 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Probe - Standard Length 350mm (14") to 1000mm (40") Process Size (in inches) NPT: ¾, 1, 1¼, 1½ BSPT: ¾, 1, 1½ JIS: 1, 1½ Insulating Material Standard Version: High Temperature Version: No insulation on active probe Tensile kg load Not applicable Probe Diameter 19mm PFA Ceramic Probe - Cable Length 500mm (20") to 25000mm (985") Process Size NPT/BSPT: 1¼" minimum Insulating Material AISI 316L SS PFA insulation optional Tensile kg load 1900 kg (4188 lbs.) Electrode Dimensions Cable: Insulated: 9mm (0.35" Non insulated: 6mm (0.24" Weight: 32 x 250mm (1.26 x 9.84") Butterfly: 175 x168mm (6.89 x 6.61") Approvals CE, CSA, NRTL/C, FM, CENELEC Please verify against device nameplate. 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 5

Installation Location Notes: Installation shall only be performed by qualified personnel and in accordance with local governing regulations. This product is susceptible to electrostatic shock. Follow proper grounding procedures. The Pointek CLS 300 as supplied in the standard probe lengths is normally mounted on the vessel top (high detection alarm) or through the tank wall at the detection level (high or low detection alarm). The cable version is designed for top mounting. The cable suspends vertically so that it reaches into the process at the desired detection level (high or low detection alarm). Angle Horizontal Vertical Page 6 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Configuration and Dimensions 191 (7.5") 146 (5.8") 136 (5.4") 181 (7.1") CABLE/ROPE insulated 9mm (0.35") non insulated 6mm (0.24") Ø32 (1.26") 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 7

Standard Version 59mm (2.3") 76mm (3") 120mm (4.7") Lid Lid Clip ½ NPT Electronics/ Enclosure 145mm (5.7") Active Shield Probe 370mm (14.6") Ø19mm (0.75") Page 8 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

High Temperature Version Ceramic Active Shield Insulator and Thermal Isolator Provides a ceramic Active Shield insulator and a Thermal Isolator for when the process temperature is greater than 200E C / 392E F and/or for when the product to be detected is very abrasive. The high temperature version is rated for applications up to 400E C / 752E F. The Thermal Isolator provides a separation distance between a high process temperature inside the vessel and the electronic housing outside the vessel. This reduces the operating temperature of the electronics to a value equal to or less than 85EC/185EF. See Temperature and Pressure Recommendations for Application on page 25. 59mm (2.3 ) Lid 76mm (3 ) 120mm (4.7 ) Lid Clip ½ NP Electronics/ Enclosure Thermal Isolator 240mm (9.4 ) Active Shield Note: dependent on probe configuration Probe 19mm (0.73 ) Warning: Do not cover the Thermal Isolator section of this Point Level Switch device with insulation material. 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 9

Rod Version The rod version of the CLS 300 is available in standard lengths from 350mm (14") up to 1000mm (40"). Other lengths using stainless steel or other metals can be attached as an electrode when required. Ensure that the thread end conforms to the exact dimensions as shown below. Rod lengths beyond 1000mm (40") are not recommended. 1.5mm by 45 (0.06") Ø19 mm (0.75" ) Ø11 mm (0.43 ) M5 3 mm (0.12 ) 12mm (0.47") Flat sides = 18mm (0.71") 9mm (0.35") 17mm (0.67") 34mm (1.3") 37mm (1.5") M10 Changing Probe Length The probe length can be shortened in the field by cutting the electrode. Warning: To prevent damage, do not apply torque directly to the main probe assembly. Option 1 If the electrode is removable: 1. Remove the electrode by releasing the set screw and turning the threaded electrode end counter-clockwise. 2. Place the upper part of the electrode in a vice as shown. 3. Use a wrench to loosen the lower portion of the electrode. Page 10 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Option 2 If electrode is NOT removable: 1. With unit mounted in place, place two wrenches as shown. 2. Hold the upper wrench steady and turn the lower one counterclockwise to loosen the lower portion of the electrode. The Wrong Way If the process connection itself is put in the vice, the probe s internal parts will rotate along with the wrench and the unit may fail. 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 11

Cable 59mm (2.3") Lid 76mm (3") 120mm (4.7") Lid Clip ½ NPT Electronics/ Enclosure 145mm (5.7") nominal value Active Shield Flexible Extension (Customer - specified length) Cable Insulated 9mm (0.35") Non insulated 6mm (0.24") 25m (82 feet) Max Probe/ Weight 250mm (9.85") Ø32mm (1.26") 175mm (6.9") Page 12 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Cable Tensile Strength Do not exceed the tensile strength of the cable at 1900kg/4188lbs. Always confirm that the load carrying capability of the silo/tank roof is sufficient to withstand the actual force on the cable conditions, especially where the force will be, or could be, as great as 1900kg/4188 lbs. A cable (rope) probe with a PFA jacket reduces the amount of possible product build-up on the probe as well as the tensile force on the cable. Cable Weights A standard weight with optional attachable Butterfly enhancer is available for the cable version. We recommend the Butterfly weight for lower dielectric constant materials (often in solids) because it increases the change in capacitance when the material comes in contact with the cable end. This occurs when the silo is quite tall (> 15 m/45 ft) and the dielectric constant is less than (> r < 4). Shortening the Cable Methods An angle grinder (preferably with a disc suitable for stainless steel) or Wire cutters (suitable for piano cable Ø6 9mm). Procedure 1. Remove Butterfly (if present) from weight. 2. Loosen the three set screws and pull weight from the cable. 3. Grind/cut the cable to the required length, and then remove rough edges from the cable. 4. Ensure that cable strands are properly seated in the lay of the cable (i.e. no wire strands sticking outside the normal cable profile). Make sure ALL strands are properly seated before continuing the assembly. 5. Push the weight onto the cable while simultaneously rotating it counterclockwise around the cable. Make sure that no cable strands are pushed out of their position in the cable and that the cable is fully inserted. 6. Re-fasten the weight by tightening the three set screws. 7. Re-attach Butterfly (if required) to the weight. 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 13

Mounting Multiple units End View Side View 500mm (20 ) min 500mm (20 ) min 500mm (20 ) min Sensors must be 500mm (20") apart. Wall Restriction Mount diagonally if vertical space is restricted. Note: These drawings are not to scale. 50mm* (2 )min 50mm* (2 )min * standard version Page 14 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Process Cautions Caution: Keep unit out of path of falling material. Caution: Consider material surface configuration when installing unit. Caution: Protect probe from falling material. Caution: Tensile load must not exceed probe or vessel rating. 500mm (20 ) min Note: buildup of material in active shield area does not affect switch. 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 15

Interconnection Trip Amplifier Loosen the lid clip and remove the enclosure cover to access connectors and electronics. The identification label is on the underside of the enclosure cover. Relay contact 8A 250Vac 5A 30Vdc Solid state switch 100mA 250Vac 100mA 300Vdc Max: 2VA Notes: Switch and potentiometer settings are for illustration purposes only. Refer to Setup on page 19. Relay contact terminals are for use with equipment having no accessible live parts and wiring having insulation suitable for at least 250V ac Maximum working voltage between adjacent relay contacts shall be 250V ac Warning: All field wiring must have insulation suitable for at least 250V ac. Page 16 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Relay Output Connection Relay shown in de-energized state. K2 contact ratings: 8A at 250V ac 5A at 30V dc Solid State Switch Switch shown in de-energized state. K3 contact ratings: 250V ac,100ma, max, nonpolarized (max 2VA) 300V dc, 100mA max, nonpolarized (max 2VA) Solid-state switch to customer s control or instrumentation device Diode Protection When driving an external relay with either the solid stated switch and/or relay outputs using dc power, protection diodes must be connected in the correct polarity across the relay coil to prevent possible switch/relay damage resulting from inductive spikes generated by the relay coil. Switch capacity: 250V ac 100mA max 2VA/2W max 300V dc. 100mA max relay coil 2VA/2W max Customer supplied diode protection relay coil Customer supplied diode protection 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 17

Ancillary 2-Wire Output Connection Output Optically isolated switch. (Customer supplied; we suggest Phoenix DEK-OE-5DC/48DC/100 or equivalent) V dc See Power Connection below. Power Connection (3 or 4 wire connection) Nominal 24V dc 48 V dc DC volts 22-26 46-50 R (S) 120 234 12 250 V (ac/dc) Page 18 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Operation Setup Note: Setup can be done in the field with the Pointek CLS 300 mounted into process, or in the shop prior to mounting. Dip Switch 1 Set ON to change alarm relay status immediately when the sensor detects a change in frequency. Use this setting when time is critical. Set OFF to change the alarm relay status with a delay by the amount set on potentiometer #1 (P1). Use this setting when you want to slow the response to account for turbulence or false readings. Dip Switch 2 Set ON to change alarm relay status immediately when the sensor detects a change in frequency. Use this setting when time is critical. Set OFF to change the alarm relay status with a delay by the amount set on potentiometer #1 (P1). Use this setting when you want to slow the response to account for turbulence or false readings. Dip Switch 3 Set OFF to indicate Low fail-safe selection. Set ON to indicate High fail-safe selection. Dip Switch 4 Set ON to test the delay of the alarm relays as set by the potentiometer #1 (P1). Set OFF for normal operation. Dip Switch 5 Set ON for normal sensitivity on the sensor. Use this setting when you are measuring dry solids or non-conductive liquids. Delay ON Delay OFF Fail-safe Delay test Sensitivity Set OFF for low sensitivity on the sensor. Use this setting to measure conductive liquids or wet conductive solids which are likely to build up. Switches shown in OFF position 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 19

Delay On Delay Off Fail-safe Delay Test Sensitivity S1-1 S1-2 S1-3 S1 4 S1-5 On Disabled Disabled High Test Normal Off Enabled Enabled Low Normal low Start Up After the CLS is properly mounted and the switch bank set up, apply power to the unit. The green LED (L3) lights to indicate the unit is powered and operational. Indicators Three LEDs indication the following: L1 (yellow) = sensor status: When P2 is properly set, this LED indicates when the sensor is in contact with the process material (material capacitance is greater than set point, P2). L1 is off when the sensor is out of contact with the process material (material capacitance is less than set point). L2 (red) = output status: L3 (green) = power: This LED indicates the relay and solid switch contact status. Refer to Operation\Output Status below. This LED is on when the Pointek CLS is properly powered. Page 20 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Alarm Output Alarm Output Status Covered Uncovered Setpoint Adjustment As reference, and to assist adjusting the alarm setpoint for reliable and accurate detection of the process material, we have categorized the materials and applications into two cases. Follow the setup procedure associated with the case which includes your application. Case 1 General applications, characterized by the following: dry solids low viscosity liquids hygroscopic / wet solids high viscosity and high conductivity liquids Case 2 Interface detection: e.g. liquid A / liquid B, foam / liquid 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 21

Trip Amplifier Case 1 Preparation Ensure that L3 (green) is ON Turn both potentiometers, P1 and P2, fully CCW (counter-clockwise) Set S1 switches 1 to 4 to OFF and S1 switch 5 to ON (normal sensitivity) Configuration 1. With sensor uncovered and a minimum 100mm free space all around, turn P2 CW until L1 (yellow) goes ON. 2. Turn P2 CCW until L1 goes OFF. Case 2 Preparation Ensure that L3 (green) is ON Turn potentiometer P1 fully CCW (counter-clockwise) Turn P2 fully CW (clockwise) Set S1 switches 1 through 5 to OFF Configuration 1. Immerse the sensor in the material that has the lowest dielectric constant. L1 (yellow) should be ON. (If L1 does not light, set S1 switch 5 to ON [normal sensitivity].) 2. Adjust P2 CCW until L1 goes OFF. 3. Immerse the sensor in the material that has the highest dielectric constant; L1 should come ON. Page 22 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Delay The alarm actuation can be delayed for either, or both, ON alarm and OFF alarm conditions. Set S1-1 and S1-2. (Refer to Setup\ Switch Bank on p. 19.) Adjust the delay time from 1 to 60 seconds by setting potentiometer P1 Operation After completing the setup, replace the Pointek CLS lid and lid clip. The unit is now in service, providing level detection of your process. 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 23

Troubleshooting Symptom Observation Action No alarm response L3 (green LED) off Check power supply Alarm won t switch when material level moves down the electrode Alarm doesn t switch when material level moves up the electrode L1 (yellow) doesn t respond to reducing level on the electrode L1 (yellow) responds to reducing level on the electrode L1 (yellow) doesn t respond to the sensing electrode approaching or touching L1 (yellow) responds to increasing level on the electrode L1 (yellow) flashes when approaching the alarm trippoint Check sensitivity, S1-5, electrode, connections to sensor input on trip amplifier (and zener barrier continuity if used) Check that relay and L2 (red LED) changes state when S1-3 is toggled Check sensitivity S1-5, electrode, (and zener barrier continuity, if used) Check that relay and L2 (red LED) changes state when S1-3 is toggled Maintenance The Pointek CLS 300 requires no regular maintenance or cleaning. Even with significant buildup on the CLS 300 level detector electrode, the level switch will continue to operate. Build-up of material on the active shield area has little or no effect on the performance of the CLS 300. Page 24 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Appendix I: Application Notes Application Notes Temperature and Pressure Recommendations for Application Note: 1 bar = 100 Pascals 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 25

Appendix II: CE Conformity WRITTEN We, DECLARATION OF CONFORMITY Siemens Milltronics Process Instruments B.V. Nikkelstraat 10-4823 AB BREDA - The Netherlands Declare, solely under own responsibility, that the product Point Level Switch, Pointek CLS 300 Mentioned in this declaration, complies with the following standards and/or normative documents: Requirements Remarks Certificate No. Environment Commercial, light Industrial, and industrial 2008949-KRQ/EMC 01-4230 EN 61326: 1998 Product group standard for Electrical equipment for measurement, control and laboratory use, from which: EN 50011: 1998 Emission Class B EN 61000-4-2: 1995 EN 61000-4-3: 1996 EN 61000-4-4: 1995 EN 61000-4-5: 1995 EN 61000-4-6: 1996 Electrostatic Discharge (ESD) Immunity Radiated Electro-Magnetic Field Immunity Electrostatic Fast Transient (EFT) Immunity Surge Transient Immunity Conducted Radio-Frequency Disturbances Immunity ATEX Directive 94/9/EC Audit Report No. 2003068 II 1/ 2 GD EEx d [ia] IIC T6 T1 0344 KEMA 00ATEXQ3047 KEMA 00ATEX2040X EN 50014: 1992 EN 50018: 1994 EN 50020: 1994 EN 50284: 1999 EN 50281-1-1: 1998 T 100 C IP 66 General Requirements Flameproof Enclosures d" Intrinsic Safety i" Special Requirements for Category 1G Equipment Dust Ignition Proof The notified body : N.V. KEMA Utrechtseweg 310 6812 AR Arnhem The Netherlands 97/23EC Pressure Equipment Directive Lloyd s Register, DAD No.: 8033472, 8033473, 8033628 The notified body: Stoomwezen B.V. Weena Zuid 168 3012 NC Rotterdam The Netherlands Location: Breda Date: Aug 31, 2001 Named Representative: C.S. van Gils Position: Managing Director Note: For specific safety specifications, please consult the instrument label. Page 26 Pointek CLS 300 INSTRUCTION MANUAL 7ML19985CK03

Index 2-Wire Connection...18 3 or 4 wire connection...18 About Pointek CLS 300...2 Adjusting Probe Length...10 Alarm Output...21 Setpoint Adjustment...21 Status...21 Ancillary 2-Wire Output Connection...18 Appendix...25 Appendix II...26 Application Notes...25 Applications...2 Approvals...5 Cable...12 Shortening it...13 Tensile Strength...13 Weights...13 Ceramic Active Shield Insulator...9 Configuration...7 DECLARATION OF CONFORMITY...26 Dimensions...7 High Temperature Version...9 Standard Version...8 Diode Protection...17 Dip Switches...19 Electrode Shortening the Probe...10 Enclosure cover removing...16 Features...2 High Temperature Version...9 Dimensions...9 High Temperatures Recommendations...9 Indicators...20 Installation...6 Location...6 Interconnection...16 Ancillary 2-Wire Output Connection...18 Diode Protection...17 Power Connection...18 Relay Output Connection...17 Solid State Switch...17 Trip Amplifier...16 LEDs...20 Location...6 Angle...6 Horizontal...6 Vertical...6 Maintenance...24 Mounting...14 Multiple Units...14 Process Concerns...15 Wall Restriction...14 Operation...19 Alarm Output...21 Set Up...19 Start Up...20 Output status...20 Outputs...2 Pointek CLS 300...2 Applications...2 Configuration...7 Dimensions...8 Features...2 Outputs...2 Power...20 Power Connection...18 3 or 4 wire connection...18 Power Supply...4 Protection diodes...17 Relay Output Connection...17 Rod Version...10 Sensor status...20 Set Up...19 Dip Switches...19 Setpoint Adjustment...21 Shield Insulator...9 Shortening Probe...10 Solid State Switch...17 Solid stated switch...17 Specifications...3 Standard Version...8 Dimensions...8 Start Up...20 Transmitter...4 Trip Amplifier...16 Troubleshooting...24 7ML19985CK03 Pointek CLS 300 INSTRUCTION MANUAL Page 27

Notes

c *7ML19985CK03*