FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 3. CONTINUOUS VENTILATION OF THE CONTAINMENT (EVR [CCVS])

Similar documents
FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 2. COMPONENT COOLING SYSTEM FOR THE NUCLEAR ISLAND (RRI [CCWS])

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS AIR-CONDITIONING OF THE MAIN CONTROL ROOM (DCL)

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER C: DESIGN BASIS AND GENERAL LAYOUT

Speransa 2008: Round table: Nuclear and sustainable development Universitad Politecnica de Valencia \UPV - Passive safety systems -

ANNEX V. AP600 & AP1000 Westinghouse Electric, USA

AP1000 European 11. Radioactive Waste Management Design Control Document

DIVISION 23 - HVAC HVAC

FIRE PROBABILISTIC SAFETY ASSESSMENT FOR KUDANKULAM NPP IN INDIA. G.Tokmachev. Atomenergoproekt, Bakuninskaya 7, Moscow, Russia

Steam and Power Conversion System

An Instrumentation and Control for Loop Test

Development of Post-Accident Monitoring System for Severe Accidents

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Davis Besse NPP Construction

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Heat pump and energy recovery systems

Comanche Peak Nuclear Power Plant. Emergency Planning

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

CONTENTS. B. System Design and Performance Requirements

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

Halton Rex 600 Basic R6B - Active chilled beam

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

Protection against Internal Hazards in the Design of Nuclear Power Plants

Chapter 11. Design of Other BOP

ITER Fire Safety Approach

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

American Nuclear Society (ANS)

HEAT TRANSPORT SHUTDOWN COOLING

Fire Risks of Loviisa NPP During Shutdown States

Appendix B3 System/Component Cause Codes

Smoke Master SMIA Compact pressurisation and smoke exhaust system

2013 ASHRAE. Standards & Guidelines CD. Contents

ISSUED IN 2015 ON BEHALF OF THE NUCLEAR POOLS FORUM 5 th EDITION

Protection against Internal Hazards in the Design of Nuclear Power Plants

Y. ORMIERES. Fire risk analysis method for nuclear installations

Boiler. Fire tube Boiler:

This copy courtesy ARS/MPI. This document is from a CD-ROM distributed courtesy of Appendix R Solutions. and Matrix Press, Inc. You may not alter,

1.0 CONDITIONS FOR CHILLED WATER SUPPLY (PRIMARY SIDE BY DHCS SUPPLIER)

Soot Mitigation Strategies

Lata Mishra Bhabha Atomic Research Centre, INDIA

SPRAY COOLING BOF HOODS by David A. Lehr, Senior Engineer UCAR Carbon Company Inc., Parma, OH

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Instrumentation for Nuclear Applications

Numerical Standards Listing

DRAFT REGULATORY GUIDE DG-1069 FIRE PROTECTION PROGRAM FOR NUCLEAR POWER PLANTS DURING DECOMMISSIONING AND PERMANENT SHUTDOWN

Steam and Gas Power Systems Prof. Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

E-16 Main Engine Remote Control System

COOPERATIVE PATENT CLASSIFICATION

Pharmaceutical Facility Design

EP ISSUES FOR INDEPENDENT SPENT FUEL STORAGE AND DECOMMISSIONING FACILITIES. Scenario Development For Shutdown And Defueled Nuclear Power Stations

Numerical Standards Listing

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Post Accident Monitoring in PFBR Safety in Nuclear Power Plant

Cork Institute of Technology Higher Certificate in Engineering in Building Services Engineering Award

Profile SFR-24 PLATEAU FRANCE. Plateforme en eau Saint Paul Lez Durance FRANCE D. GUENADOU. CEA Cadarache

SEMICONDUCTOR FABRICATION FACILITIES

Element Z General Design Requirements Existing Facilities Information

H Series Surgical room air conditioners. with direct expansion coil: OHA series with chilled water coil: OHU series

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

Numerical Standards Listing

Radiation Control and Monitoring System on the HTTR

INTRODUCTION TO SOLAR THERMAL POWER STATIONS We shall look at some of the different methods of supplying solar energy to the power stations.

LARGE CAPACITY HEATERS

A/C-HEATER SYSTEM - MANUAL

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

BOILERS CHAPTER 4. Fireroom The fireroom is a compartment containing boilers and the operating station for firing the boilers.

Fire protection on chemical manufacturing sites

LONGONI ENGINEERING SRL

Reactor Protection Systems for the Replacement Research Reactor, ANSTO

Attention is drawn to the following places, which may be of interest for search:

Climate Control System

Appendix 13. Categories of Cooling and Heating systems

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Series 300 VTB. Installation Instructions

ENGINE GENERATORS AND ACCESSORIES

9. Cooling Water System

Adca Training. Part 2

Design Characteristics and Classification Issue of the I&C Systems for the JRTR

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

HEATING AND AIR CONDITIONING

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

RECOMMENDED GOOD PRACTICE

SEMICONDUCTOR FABRICATION FACILITIES

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

Emis. Unit Description:

HEATING THE HOME UNIVERSITY 0 F ILLINOIS BULLETIN REVISED BY DONALD E. BROTHERSON, A. I. A.

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

RULES FOR CLASSIFICATION OF MOBILE OFFSHORE UNITS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

User Guide Compact-7 series

COMPLIANCE INSPECTION CHECKLIST. Date: 5/14/2011 Time In: 12:30PM Time Out: 1:00PM

Transcription:

PAGE : 1 / 7 3. CONTINUOUS VENTILATION OF THE CONTAINMENT (EVR [CCVS]) GENERAL DESIGN OF THE REACTOR BUILDING VENTILATION SYSTEM Access into the Reactor Building is permitted during operation between seven days before and three days after a shutdown. To enable access during power operation and to reduce the risk of radiological effects on staff, the containment is divided into two separate areas (see I.4.3 FIG 1): - a service area, which is accessible during plant operation - an equipment compartment The equipment compartment of the BR [Reactor Building] is made up primarily of the following areas: - rooms containing the primary circuit - rooms containing Safety Injection System (RIS [SIS]) valves - rooms containing primary circuit Chemical and Volume Control System (RCV [CVCS]) equipment - rooms containing Steam Generator Blowdown (APG [SGBS]) equipment - the IRWST (RIS [SIS]) pool and the corium-spreading area An airtight structure around the equipment compartment encloses the primary circuit components and systems that may cause radioactive leaks. When contamination is detected during access to the plant, the RB [Reactor Building] ventilation systems maintain dynamic containment between the equipment compartment and the service area. A pressure barrier is created and uncontrolled transfer of activity from the equipment compartment to the service area is not possible (for operation of the plant without access, see Chapter I.4.4; in the case of access, see Chapter I.4.5). The containment continuous ventilation system (EVR [CCVS]) is divided into two separate systems: - a system for continuous ventilation of the service area (EVR [CCVS] service area) - a system for continuous ventilation of the equipment compartment (EVR [CCVS] equipment compartment)

PAGE : 2 / 7 3.1. ROLE OF THE SYSTEM 3.1.1. Functional role of the system The functional role of the EVR [CCVS] service area is as follows: 3.1.1.1. EVR [CCVS] Service area - maintaining ambient conditions acceptable for staff working in the RB service area - maintaining ambient conditions needed to ensure correct operation of instrumentation and equipment 3.1.1.2. EVR [CCVS] - Equipment compartment The functional role of the EVR [CCVS] equipment compartment is as follows: - to maintain the ambient conditions necessary to ensure correct operation of the equipment - to ventilate and cool the control rod mechanisms - to ventilate and cool the reactor pit - to produce environmental conditions acceptable for staff working in the BR [Reactor Building] equipment compartment during cold shutdown 3.1.2. The system safety role The general safety requirements are given in Chapter I.4.0. The only safety function of the EVR [CCVS] is the cooling of the reactor pit during an SBO [station blackout]. 3.2. DESIGN BASES 3.2.1. EVR [CCVS] service area With the plant in operation, during hot and cold shutdown, the EVR [CCVS] service area extracts the heat discharged by the RB [Reactor Building] service area equipment and the walls and airtight structures of the equipment compartment. The interior temperatures and humidity are defined in Chapter I.4.1; they allow staff to access the service area when the plant is in operation. The cooling function is fulfilled by the local air-conditioning plants; the cooling coils are fed by the DER [chilled water] system.

PAGE : 3 / 7 3.2.2. EVR [CCVS] - equipment compartment With the plant in operation or during hot shutdown, the EVR [CCVS] equipment compartment removes the heat produced by the equipment, including the control rod drive mechanisms (the four primary pump motors are not included here as they are cooled directly by the RRI [CCWS]). The interior temperatures are defined in Chapter I.4.1. The cooling function is performed as follows: - by cooling coils supplied by the RRI [CCWS] operating continuously - by cooling coils supplied by the DER [chilled water] system operating if necessary, i.e. if the RRI [CCWS] temperature is above 28 C. Staff access under the temperature conditions given in Chapter I.4.1 is permitted only during cold shutdown. 3.3. DESCRIPTION AND CHARACTERISTICS OF EQUIPMENT See I.4.3 FIG 1 to I.4.3 FIG 3 3.3.1. EVR [CCVS] Service area The EVR [CCVS] service area operates in a closed circuit mode with local air-conditioning units. Each air-conditioning unit is equipped with a cooling coil connected to the DER [chilled water] system and a fan that blows cold air into the zones to which staff access is provided for systematic activities. The system operates continuously and the air-conditioning capacity needed is divided into several units, serving the following: - operating floor - annulus - penetration area - core instrumentation (2 x 100%) Two of the operating floor local air-conditioning units are connected by a duct to the BR [Reactor Building] dome. 3.3.2. EVR [CCVS] - equipment compartment The EVR [CCVS] equipment compartment system operates in a closed circuit only for the primary circuit component rooms and the adjacent rooms where the auxiliary systems containing radioactivity are located. Atmospheric contamination resulting from leaks from these systems is contained in this ventilation system. It comprises two trains, each featuring:

PAGE : 4 / 7 - two fans (2x50%) known as main fans - two cooling coils (2x25%) fed by the RRI [CCWS] - two cooling coils (2x25%) fed by the DER [chilled water] system This system operates continuously with two main fans (one fan operating per train and the other as back-up). Each train blows fresh air into a semi-circular concrete header located above the RIS [SIS] valve room. Different branches are connected to the semi-circular header to provide the air supply in the various zones: - the four primary coolant pumps - the four steam generators - the RCV [CVCS] rooms - the RPE [NVDS] rooms - the APG [SGBS] rooms - the reactor pit; the reactor pit is ventilated by two trains each associated with an air supply branch and equipped with two fans (2 x 50%) Certain air supplies are tapped upstream of the headers and supply the air: - to the control rod drive mechanism - to the pressuriser - under the steam generator compartment ceiling 3.4. OPERATING CONDITIONS 3.4.1. Normal state of the system This state corresponds to conditions during plant operation or hot shutdown. 3.4.1.1. EVR [CCVS] Service area All local air-conditioning units operate continuously and maintain the specified environmental temperatures. In the instrumentation room, a back-up air-conditioning unit is provided in the event of failure of the unit in operation. 3.4.1.2. EVR [CCVS] - Equipment compartment On each of the two trains, a main fan and a reactor pit fan are operating. The total air flow of the EVR [CCVS] equipment compartment is 220,000 m³/hr at 30 C.

PAGE : 5 / 7 The cooling coils are fed by the RRI [CCWS] If the temperature at the inlet of the RRI [CCWS] is above 28 C, the cooling coils fed by the DER [chilled water] add to the cooling of the air. The condensates are extracted by the RPE [NVDS]. 3.4.2. Permanent system loads Staff access before/after shutdown Access to the RB [Reactor Building] is allowed when the reactor is in operation between seven days before and three days after shutdown. In the accessible area, defined as the service area, the EVR [CCVS] service area maintains environmental conditions acceptable for staff. Two days before and during man access, fresh air is brought in by the EBA [CSVS] low flow rate system, for purging purposes (see Chapter I.4.5). Shutdown During cold shutdown, the RB [Reactor Building] is ventilated by the EBA [CSVS] (high and low flow rate EBA [CSVS]). The fresh air brought in by the EBA [CSVS] is distributed through the service area of the Reactor Building then in the equipment compartment via the EBA [CSVS] 1120RA damper (see Chapter I.4.5) and the EVR [CCVS] 1101 and 1201RA dampers. The air is then distributed by the fans and ducts of the EVR [CCVS] equipment compartment to all rooms. The system operates with EVR [CCVS] cooling coils until a temperature below 33 C is reached. 3.4.3. Transient system states Partial or total loss of cooling water The RRI [CCWS] and DER [chilled water] cooling coils are no longer supplied. The fans continue to operate to prevent hot spots. Loss of Primary Coolant Accident (LOCA) During and after this type of accident, the containment continuous ventilation systems are not required. Fuel handling accident in the RB [Reactor Building] In the event of a fuel handling accident, and although this is not a safety requirement, the EVR [CCVS] can be used to remove heat released. Generalised Voltage Loss (SBO [station blackout]) In the event of a station blackout, only the fans associated with the reactor pit are backed up. This helps maintain the temperature at the top of the pit below 75 C, i.e. the maximum allowable temperature 24 hours following an SBO.

PAGE : 6 / 7 3.5. PRELIMINARY SAFETY ANALYSIS 3.5.1. Compliance with regulations To follow. 3.5.2. Compliance with functional criteria The EVR [CCVS] is designed to meet the objective of maintaining acceptable temperature conditions in the reactor pit. 3.5.3. Compliance with design requirements 3.5.3.1. Safety classifications The compliance of the equipment design and manufacture with requirements derived from the classification rules is detailed in Chapter C.2. 3.5.3.2. Single Failure Criterion (SFC) and redundancy The reactor pit ventilation system comprises two trains each equipped with two 2 x 50% fans, making a global redundancy of 4 x 50%. 3.5.3.3. Qualification The equipment is qualified in accordance with the requirements described in Chapter C.7. 3.5.3.4. Instrumentation and control The compliance of the equipment design and manufacture with requirements derived from the classification rules is detailed in Chapter C.2. External Undervoltage (LOOP) In the event of LOOP : - The reactor pit fans are backed up, 3.5.3.5. Uninterruptible power supplies - the main fans of the EVR [CCVS] equipment compartment are backed up by the diesel generators This is not a safety requirement, but it helps avoid damage to equipment Generalized Voltage Loss (SBO [station blackout]) In the event of SBO the fans associated with the reactor pit are backed up.

PAGE : 7 / 7 See I.4.3 TAB 1. 3.5.3.6. Hazards 3.6. TESTS, INSPECTIONS AND MAINTENANCE 3.6.1. Periodic tests The safety functions are subject to periodic tests. 3.6.2. Inspection and maintenance Maintenance of the EVR [CCVS] is performed during plant shutdown, when access to the entire BR [Reactor Building] is possible and the environmental conditions in the BR [Reactor Building] are ensured by the EBA [CSVS]. 3.7. MECHANICAL DIAGRAM See I.4.3 FIG 2 and I.4.3 FIG 3.