DSPA DSPA B.V. Product Certificate K86591/07 UK. Non-Pressurized Condensed Aerosol Generators and Components K86591/06 UK

Similar documents
fixed dry aerosol fire extinguishing components FirePro Systems Ltd.

Check valves, family E, type B

Vulcanised rubber products for cold and hot drinking water applications

CPVC solvent cements for CPVC pipes and fittings

Leadax B.V. Covenant K93792/02. Leadax

Report of fire tests on Li-ion batteries based on condensed aerosol

Sanitary tapware: mechanical mixers

Number K4126/06 Replaces K4126/05. Issued Dated Valid until Indefinite Page 1 of 6

Villeroy & Boch AG. the Kiwa evaluation guideline BRL-KK621/06 Close coupled suites. EN 997: 2003 WC pans with integral trap.

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

GASTEC QA. Approval Requirements 136

GASTEC QA. Approval Requirements 31-2

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

GASTEC QA. Approval Requirements 31-1

GASTEC QA. Approval Requirements 6

Fire Protection Scover

GASTEC QA. Approval Requirements 69-1

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers

BRL-K602. Datum Evaluation Guideline

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

Demolition Permit Application (Please print and complete ENTIRE form)

Evaluation guideline. for the Kiwa product certificate for external Polyurethane Coatings on ductile iron pipes for underground installation

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

EC Type Examination Certificate

Lawnmowers, pedestrian controlled (combustion engine powered)

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

GASTEC QA. Approval Requirements 201. Amendment A1. for the GASTEC QA product certificate for Gas service lines to residences and buildings

FirePro ANNEX 1 MARINE MANUAL. Version 1,

SOUTH AFRICAN NATIONAL STANDARD

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water

CO 2 Fire Extinguishing Systems

Reflex fire detection and extinguishing system charged with Novec 1230 extinguishing agent. Installation, operation and maintenance instructions

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

Reflex fire detection and extinguishing system filled with ABC dry powder. Installation, operation and maintenance instructions

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Kiwa Regulations for Certification in accordance with the CPR

Certificate of Compliance

Evaluation Guideline

User s Information Manual

Good Ideas For Propane Safety

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

FIRE SAFETY. Department of Chemical Engineering College of Engineering

(German speaking trainers with English written slides)

VERIFICATION OF AN AEROSOL LEAK DETECTOR FOR THE ALTERNATIVE TO THE WATERBATH METHOD FOR RAUPACK LIMITED

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

FirePro CERTIFICATES, APPROVALS & TEST REPORTS. Underwriters Laboratories of USA, UL Listing Certificate No EX6960, 02/08/11.

P50 Composite Extinguisher The New Generation. Britannia Fire Proudly manufacturing in Great Britain since 2010 SECURITY.

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

NFPA 45 NFPA 211 NFPA 1600

Please read operating instructions carefully before use and keep for further reference.

Guidelines for Fire Safety Plans at Construction or Demolition Sites

Gas Fire Patio Heater Lhotse-817

WSU-TFREC Fire Safety Training

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Certificate of Compliance

Fire Detection and Alarm System (FDAS) & Fire Detection and Suppression Systems (FDSS) for Buses - Requirements

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

SFI SPECIFICATION 17.1 EFFECTIVE: FEBRUARY 26, 2014 *

Installation and Maintenance Manual Please retain this manual for future reference.

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Lawnmowers (pedestrian controlled electric mains-powered)

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/H18/9039 Rev 1

installation & operating instructions

automatic FiReFighTing SYSTeMS in PainT booths

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

Element C3.4 Fire Fighting Equipment

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

BRL-K17401 Comments before.. Replaces BRL-K17401 d.d. 16 April Evaluation guideline

Operating instructions

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

Whole Room Dryer WRD, WRD/110

IGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type

Building Services Brochure

Sip Vacuum Cleaner 1400/35 Wet & Dry

OPTIBAR DP 7060 Supplementary Instructions

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association

HYDROMIST LITE CARPET CLEANER OPERATOR MANUAL

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches

Deluxe Discharge Alarm

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

BRL-K656/ Evaluation guideline. for the Kiwa product certificate for heat exchangers intended for the indirect heating of drinking water

Finalized Draft AUTOMOTIVE INDUSTRY STANDARD

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BRL-K Evaluation Guideline

Transcription:

Product Certificate Issued 2018-07-11 Valid until 2019-07-10 Replaces Page 1 of 6 K86591/06 UK DSPA Non-Pressurized Condensed Aerosol Generators and Components STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Product Certification, Kiwa declares that legitimate confidence exists that the products supplied by DSPA B.V. complying with the technical specifications as laid down in this product certificate and marked with the Kiwa -mark in the manner as indicated in this product certificate, on delivery, may be relied upon to comply with Kiwa evaluation guideline BRL-K23001/04 the product certificate for fixed dry aerosol fire extinguishing components. Luc Leroy Kiwa Publication of the certificate is allowed. This certificate consists of 6 pages Note: Publication of only this front page or parts of the certificate is considered as not valid. Advice: consult www.kiwa.nl in order to ensure that this certificate is still valid Kiwa Nederland B.V. Certification Fire Safety & Security Dwarsweg 10 5301 KT Zaltbommel The Netherlands Tel. +31 88 9985100 Company DSPA B.V. Hulzenseweg 10-20 6534 AN NIJMEGEN P.O. Box 6572 6503 GB NIJMEGEN The Netherlands Tel. +31 24 352 25 73 Fax +31 24 37 87 583 www.dspa.nl Certification process consists of initial and regular assessment of: quality system product

Page 2 of 6 Certificate This product certificate by Kiwa is based on the guideline BRL-K23001/04. Generator specifications The products mentioned below belong to this product declaration. Housing Red coated steel Activation DSPA 8-1 Cylindrical, axial Electrical DSPA 8-1 60 Cylindrical, axial Electrical DSPA 11-1 Disk, radial, double shaped plate Electrical DSPA 11-2 Disk, radial, double shaped plate Electrical DSPA 11-3 Disk, radial, double shaped plate Electrical DSPA 11-4 Disk, radial, double shaped plate Electrical DSPA 11-5 Disk, radial, double shaped plate Electrical DSPA 11-6 Disk, radial, double shaped plate Electrical DSPA 11-7 Disk, axial, double shaped plate Electrical DSPA 12-1 Disk, radial, single shaped plate Electrical or Thermal cord DSPA 12-2 Disk, radial, single shaped plate Electrical or Thermal cord DSPA 12-3 Disk, radial, single shaped plate Electrical or Thermal cord DSPA 12-4 Disk, radial, single shaped plate Electrical or Thermal cord DSPA 12-5 Disk, radial, single shaped plate Thermal cord Non-pressurized generator. Application and use Total flooding fire-extinguishing systems are used primarily for protection against hazards that are in enclosures or equipment that, in itself, includes an enclosure to contain the extinguishant. Condensed aerosol generators can be used as a part of fire fighting systems in buildings, plants or other structures. It covers total flooding systems primarily related to buildings, plant and other specific applications, utilizing electrically non-conducting condensed aerosol fire extinguishants. The following are typical of such hazards, but the list is not exhaustive: a) Electrical and electronic hazards; b) Telecommunications facilities; c) Flammable and combustible liquids and gases; Where aerosol generators are used in a potentially explosive application, the suitability of the generator to the atmosphere for the determined life shall be assessed. The fire extinguishing components shall be suitable for extinguishing fires of the following classes: Class A according EN2 Class B according EN2 Conditions for application The numbers and types of the extinguishing components have to be determined in conformity with the guidelines and calculation methods of the supplier. Distribution is to be done by supplier or companies authorised by the supplier. Before usage an instruction is to be given by a trainer or instructor for this product authorized by the supplier /manufacturer. The installation and maintenance of the fire extinguishing components have to take place according to the specifications of the supplier/manufacturer, ISO15779, CEN/TR 15276-2 and/or evaluation guideline BRL-K23003. For specific details regarding the owner s manual, CEN/TR 15276-1.

Page 3 of 6 Point of interest during use The condensed aerosol extinguishing components should not be used on fires involving the following unless relevant testing by accredited testing laboratories has been carried out to the satisfaction of the Authority: Temperatures for use of aerosol extinguishing agents shall be within the supplier s listed limits. Local applications 1) of condensed aerosol extinguishing systems are not covered by this product declaration. o Local applications require a pre-engineered and pre-designed system which has been tested and approved for a specific application by an authority such as Kiwa or by an accredited testing laboratory. 1) a local application is used for the extinguishment of surface fires in flammable liquids, gasses, and shallow solids, where the enclosure does not conform to the requirements for total flooding. The above list may not be exhaustive. Manual At delivery the product should be accompanied by an operation manual in the English language, known and authorized by Kiwa. Following minimum items shall be described: of aerosol generators; Design application density; Description of occupancies and hazards to be protected against; Specification of aerosol generators; Equipment schedule or list of materials for each piece of equipment or device, showing device name; supplier, model or part number and description; System calculation; Enclosure pressurization and venting calculations; Description of fire detection, actuation and control systems. Requirements for inspection, maintenance and testing of an aerosol fire-extinguishing system and for the training of inspection and maintenance personnel. For specific details regarding the owner s manual, see CEN/TR 15276-1. Marking The products should be marked with the Kiwa -mark. Place of the mark: On the generator Required specifications: Name of the product and supplier Supplier s type designation Production date and serial number Mass of aerosol-forming compound Temperature range Storage humidity range Service life Distances as specified in table 5 Reference to the application instructions Certification mark Class A according EN2 Class B according EN2 Method of marking Non-erasable and non-detachable; Non-flammable; Permanent an legible

Page 4 of 6 Recommendations for customers Check at the time of delivery whether: The supplier has delivered in accordance with the agreement; The mark and the marking method are correct; The products show no visible defects as a result of transport etc. If you should reject a product on the basis of the above, please contact: DSPA B.V. and, if necessary, Kiwa Nederland B.V. Consult the supplier's processing guidelines for the proper storage and transport methods.

Page 5 of 6 Product specifications Table 1 Fire Class Listing According Pre burn time Soak period Test room Density EN2 Material / fuel CEN/TR 15276-1 in seconds in seconds in m 3 in grams / A Wood crib A.6.1 120 600 101.3 116 A Class A compatible wood crib test - 120 600 101.3 79 A Polymethylmethacrylate A.6.3 210 600 112.12 97 A Polypropylene A.6.3 210 600 112.12 58 A ABS A.6.3 210 600 112.12 87 A Reformed wood (chops) A.6.4 360 600 112.12 29 A MDF A.6.4 360 600 112.12 59 A Multilayers plywood A.6.4 360 600 112.12 87 B Heptane A.6.2 30 30 112.12 34 C Propane (30 Kilowatt) - 30 600 106.16 31 m 3 Table 2 Efficiency in % Efficiency in % DSPA 11-1 100 DSPA 8-1 100 DSPA 11-2 88-100 DSPA 8-1 60 100 DSPA 11-3 90-100 DSPA 12-1 100 DSPA 11-4 100 DSPA 12-2 100 DSPA 11-5 94-100 DSPA 12-3 96-100 DSPA 11-6 100 DSPA 12-4 100 DSPA 11-7 100 DSPA 12-5 90-100 Table 3 Housing and Agent distribution according CEN/TR 15276-1 Discharge method Minimum height Maximum area coverage in m Maximum height in m Maximum area coverage in m in m DSPA 8-1 Cylinder, axial 2.44 9.76 x 3.66 4.88 4.88 x 3.66 DSPA 8-1 60 Cylinder, axial 2.44 9.76 x 3.66 4.88 4.88 x 3.66 DSPA 11-1 Disk, radial 0.50 3.66 x 1.22 1.83 1.22 x 1.22 DSPA 11-2 Disk, radial 0.50 3.66 x 2.44 2.44 1.22 x 1.22 DSPA 11-3 Disk, radial 0.50 3.66 x 2.44 2.44 1.22 x 1.22 DSPA 11-4 Disk, radial 1.22 3.66 x 3.66 3.05 1.83 x 1.83 DSPA 11-5 Disk, radial 1.22 4.88 x 3.66 3.66 2.44 x 2.44 DSPA 11-6 Disk, radial 1.22 7.32 x 3.66 3.66 2.44 x 2.44 DSPA 11-7 Disk, axial 1.22 7.32 x 1.22 3.05 1.83 x 1.83 DSPA 12-1 Disk, radial, 0.50 0.81 x 0.73 DSPA 12-2 Disk, radial, 0.50 0.81 x 1.60 0.80 0.81 x 0.74 DSPA 12-3 Disk, radial, 0.80 0.81 x 1.49 1.99 0.81 x 0.86 DSPA 12-4 Disk, radial, 1.60 0.81 x 1.99 1.99 0.81 x 1.60 DSPA 12-5 Disk, radial, 0.53 0.25 x 0.59

Page 6 of 6 Table 4 Discharge time In Sec Discharge time In Sec DSPA 11-1 6-10 DSPA 8-1 67-89 DSPA 11-2 9-15 DSPA 8-1 60 48-58 DSPA 11-3 14-26 DSPA 12-1 9-11 DSPA 11-4 19-31 DSPA 12-2 13-15 DSPA 11-5 40-60 DSPA 12-3 9-11 DSPA 11-6 30-50 DSPA 12-4 11-14 DSPA 11-7 30-50 DSPA 12-5 5-7 Table 5 Distance in m 75 C 200 C 400 C DSPA 8-1 1.5 0.75 0.15 DSPA 8-1 60 3.0 1.0 0.10 DSPA 11-1 0.5 0.15 0.05 DSPA 11-2 0.5 0.15 0.05 DSPA 11-3 0.5 0.15 0.05 DSPA 11-4 1.0 0.25 0.15 DSPA 11-5 1.0 0.25 0.15 DSPA 11-6 1.5 0.35 0.15 DSPA 11-7 1.5 0.50 0.10 DSPA 12-1 0.08 0.03 0.01 DSPA 12-2 0.15 0.08 0.02 DSPA 12-3 0.25 0.10 0.03 DSPA 12-4 0.30 0.15 0.05 DSPA 12-5 0.08 0.03 0.01